Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Tracking System for Infrared Spectrometer

Visible laser tracking system for infrared laser spectometer keeps probe infrared laser beam aimed at moving reflector, thereby keeping reflector image and return laser beam within spectrometer field of view. System includes tracking mirror tilted by stepping motors under microprocessor control to deflect beams toward continually changing reflector position.

Johnson, R. A.↗

Design of a Far-Infrared Spectrometer for Atmospheric Thermal Emission Measurements

Global measurements of far infrared emission from the upper troposphere are required to test models of cloud radiative forcing, water vapor continuum emission, and cooling rates. Spectra with adequate resolution can also be used for retrieving atmospheric temperature and humidity profiles, and yet there are few spectrally resolved measurements of outgoing longwave flux at wavelengths longer than 16 m. It has been difficult to make measurements in the far infrared due to the need for liquid-helium cooled detectors and large optics to achieve adequate sensitivity and bandwidth. We review design considerations for infrared Fourier transform spectrometers, including the dependence of system performance on basic system parameters, and discuss the prospects for achieving useful sensitivity from a satellite platform with a lightweight spectrometer using uncooled detectors.

Johnson, David G.↗

Comparison of column abundances from three infrared spectrometers during AASE 2

Three Fourier transform infrared (FTIR) spectromenters were based on board the NASA DC-8 during the second Airborne Arctic Stratospheric Expedition (AASE II) in 1992. Two FTIRs used solar absorption and one used thermal emission. We compare over 2000 measurements from these 3 FTIRs, on 12 DC-8 flights, for closely coincident air masses and times, both inside and outside the polar vortex. In the majority of cases the offset biases are quite small, in the range 1-4%, and comparable to the absolute precisions expected. In most cases the rms scatter is in the range 4-11%; this scatter is unlikely to be geophysical, but rather is probably instrumental or analytical in origin.

Traub, W. A.↗

Compact Infrared Spectrometers

Concentric spectrometer forms are advantageous for constructing a variety of systems spanning the entire visible to infrared range. Spectrometer examples are given, including broadband or high resolution forms. Some issues associated with the Dyson catadioptric type are also discussed.

imaging spectroscopy↗

Grid polarizers for infrared Fourier spectrometers

Infrared grid polarizers consisting of copper lines with a 3.6-micron grid constant on a 4-micron-thick Mylar polyester substrate have been prepared by the techniques of photolithography and sputter-etching. Their polarization properties have been measured and found to be suitable for use at infrared frequencies below 700/cm. The polarizers have been used to extend the useful frequency range of a Martin-Puplett polarizing interferometer designed for Fourier transform spectroscopy. The efficiency of the interferometer has been measured over a frequency range from 50 to 700/cm and compared to that of a conventional Michelson interferometer. The results are shown to be consistent with the measured properties of the polarizers. Methods are suggested for improving the efficiency of a Martin-Puplett interferometer which employs these polarizers.

Challener, W. A.↗

A close-up look at Io from Galileo's near-infrared mapping spectrometer

Infrared spectral images of Jupiter's volcanic moon Io, acquired during the October and November 1999 and February 2000 flybys of the Galileo spacecraft, were used to study the thermal structure and sulfur dioxide distribution of active volcanoes. Loki Patera, the solar system's most powerful known volcano, exhibits large expanses of dark, cooling lava on its caldera floor. Prometheus, the site of long-lived plume activity, has two major areas of thermal emission, which support ideas of plume migration. Sulfur dioxide deposits were mapped at local scales and show a more complex relationship to surface colors than previously thought, indicating the presence of other sulfur compounds.

long duration↗

An airborne far-infrared spectrometer for astronomical observations

A Fabry-Perot spectrometer for airborne observations of astronomical spectral lines has been designed for use in the 50 to 200 micron region of the far-infrared. The spectrometer uses a fixed wavelength Fabry-Perot filter cooled to 4.2 K in conjunction with a high order scanning Fabry-Perot at room temperature. This arrangement provides high spectral resolution and also minimizes the thermal background radiation on the detector. The instrument has been successfully used to study all the presently detected fine structure lines between 50 and 120 microns.

Storey, J. W. V.↗

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the µ-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the 555 – 714 µm range with a resolution of R = λ/∆λ = 512 at the 638 µm band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM µ-Spec design is an advancement upon a successful R = 64 µ-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single M=2 grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ∼8 × 10−19 W/√( Hz). We summarize the design, fabrication, and ongoing development of these µ-Spec spectrometers for EXCLAIM.

Carolyn G. Volpert↗

The SOFIA/SAFIRE Far-Infrared Spectrometer: Highlighting Submillimeter Astrophysics and Technology

The Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory is an imaging spectrometer for wavelengths between 28 microns and 440 microns. Our design is a dual-band long-slit grating spectrometer, which provides broadband (approx. 4000 km/s) observations in two lines simultaneously over a field of view roughly 10" wide by 320" long. The low backgrounds in spectroscopy require very sensitive detectors with noise equivalent powers of order 10(exp -18) W/square root of Hz. We are developing a kilopixel, filled detector array for SAFIRE in a 32 x 40 format. The detector consists of a transition edge sensor (TES) bolometer array, a per-pixel broadband absorbing backshort array, and a NIST SQUID multiplexer readout array. This general type of array has been used successfully in the GISMO instrument, so we extrapolate to the sensitivity needed for airborne spectroscopy. Much of the cryogenic, electronics, and software infrastructure for SAFIRE have been developed. I provide here an overview of the progress on SAFIRE.

Benford, Dominic J.↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Measurement of HO2 and other trace gases in the stratosphere using a high resolution far-infrared spectrometer at 28 KM

The major events and results to date of the ongoing program of measuring stratospheric composition by the technique of far-infrared Fourier-transform spectroscopy from a balloon-borne platform are reviewed. The highlights of this period were the two balloon flight campaigns which were performed at Palestine, Texas, both of which produced large amounts of scientifically useful data.

Traub, Wesley A.↗

Design and Performance of Micro-Spec, an Ultra Compact High-Sensitivity Far-Infrared Spectrometer for SPICA

Micro-Spec (u-Spec) is a high-performance spectrometer working in the 250-700-micrometer wavelength range, whose modules use low-loss superconducting microstrip transmission lines on a single 4-inch-diameter silicon wafer. Creating the required phase delays in transmission lines rather than free space allows such an instrument to have, in principle, the performance of a meter-scale grating spectrometer. Such a dramatic size reduction enables classes of instruments for space that would be impossible with conventional technologies. This technology can dramatically enhance the long-wavelength capability of the space infrared telescope for cosmology and astrophysics SPICA. u-Spec is analogous to a grating spectrometer. The phase retardation generated by the reflection from the grating grooves is instead produced by propagation through a transmission line. The power received by a broadband antenna is progressively divided by binary microstrip power dividers, and the required phase delays are generated by different lengths of microstrip transmission lines. by arranging these outputs along a circular focal surface, the analog of a Rowland spectrometer can he created. The procedure to optimize the Micro-Spec design is based on the stigmatization and minimization of the light path function in a two-dimensional hounded region, which results in an optimized geometry arrangement with three stigmatic points. In addition, in order to optimize the overall efficiency of the instrument, the emitters are directed to the center of the focal surface. The electric field amplitude and phase as well as the power transmitted and absorbed throughout the region are analyzed. Measurements are planned in late summer to validate the designs.

Cataldo, Giuseppe↗

Waveguide Modulator for Interference Tolerant Functional Near Infrared Spectrometer (fNIRS)

Many crew-related errors in aviation and astronautics are caused by hazardous cognitive states including overstress, disengagement, high fatigue and ineffective crew coordination. Safety can be improved by monitoring and predicting these cognitive states in a non-intrusive manner and designing mitigation strategies. Measuring hemoglobin concentration changes in the brain with functional Near Infrared Spectroscopy is a promising technique for monitoring cognitive state and optimizing human performance during both space and aviation operations. A compact, wearable fNIRS system would provide an innovative early warning system during long duration missions to detect and prevent vigilance decrements in pilots and astronauts. This effort focused on developing a waveguide modulator for use in a fNIRS system.

spectroscopy↗

OSIRIS-REx Visible And Infrared Spectrometer - OVIRS

Goddard Space Flight Center: Overall Instrument Responsibility; Instrument Scientist and Deputy Instrument Scientist; Management Systems Engineering; Mechanical Hardware; Harness Assemblies; SIDECAR Assembly Code; OVIRS Integration and Environmental Qualification; OVIRS Performance Testing, Calibration and Characterization.

OSIRIS-REx↗

Exploring the Saturn System in the Thermal Infrared: The Composite Infrared Spectrometer

The Composite Inbred Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wave number, from 10 to 1400 cm (1 mm to 7pm), with a spectral resolution that can be set from 0.5 to 20 cm. The far in portion of the spectrum (10 - 600 cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600 - 1100cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. CIRS observations will provide three-dimensional maps of temperature, gas composition, and aerosols/condensates of the atmospheres of Titan and Saturn with good vertical and horizontal resolution, from deep in their tropospheres to high in their mesospheres. CIRS ability to observe atmospheres in the limb viewing mode (in addition to nadir) offers the opportunity to provide accurate and highly resolved vertical profiles of these atmospheric variables. The ability to observe with high-spectral resolution should facilitate the identification of new constituents. CIRS will also map the thermal and compositional properties of the surfaces of Saturn's icy satellites. It will similarly map Saturn's rings, characterizing their formation and evolution. The combination of broad spectral range, programmable spectral resolution, the small detector fields of view, and an orbiting spacecraft platform will allow CIRS to observe the Saturnian system in the thermal infrared at a level of detail not previously achieved.

Flasar, F. M.↗