Search NASA⌕ Search

SEARCH · Search NASA

Results for “insert magnet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assembly of the MOLLER Toroidal Magnets at Jefferson Lab

The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. Here, this paper presents the assembly process for these five toroidal magnets, detailing critical steps including epoxy application, pin insertion, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.

Lamont, Joseph [Thomas Jefferson National Accelera↗

Magnetic and Mechanical Analysis of a Large Aperture 15 T Cable Test Facility Dipole Magnet

The US Department of Energy (DOE) Office of Science (SC), is funding a large bore “Cable Test Facility Magnet” for testing advanced cables and inserts in high transverse field. This is a joint effort between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). The background field magnet for this facility is being developed at Lawrence Berkeley National Laboratory (LBNL) while the cryostat and test facility will be located and operated by Fermi National Accelerator Laboratory (FNAL). The Nb 3 Sn dipole magnet, which will provide the transverse background field, is designed to generate a field of 15 T in a 100 × 150 mm bore at 1.9 K. The conceptual design of a block-type dipole with flared ends and a structure based on key-and-bladder technology will be introduced. The results of the magnetic and mechanical analysis will be presented.

43 PARTICLE ACCELERATORS↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Possibilities of Predicting Geomagnetic Secular Variation with Geodynamo Modeling

We use our MoSST core dynamics model and geomagnetic field at the core-mantle boundary (CMB) continued downward from surface observations to investigate possibilities of geomagnetic data assimilation, so that model results and current geomagnetic observations can be used to predict geomagnetic secular variation in future. As the first attempt, we apply data insertion technique to examine evolution of the model solution that is modified by geomagnetic input. Our study demonstrate that, with a single data insertion, large-scale poloidal magnetic field obtained from subsequent numerical simulation evolves similarly to the observed geomagnetic variation, regardless of the initial choice of the model solution (so long it is a well developed numerical solution). The model solution diverges on the time scales on the order of 60 years, similar to the time scales of the torsional oscillations in the Earth's core. Our numerical test shows that geomagnetic data assimilation is promising with our MoSST model.

Kuang, Wei-Jia↗

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

High Speed Hybrid Reluctance Motor Utilizing Anisotropic Materials

With high cost and volatility driving continued efforts to decrease reliance on the critical heavy rare earth materials used in traction drive applications, General Motors developed three variants of heavy rare earth-free (HRE-free) electric motors. The variants focused on taking advantage of advanced magnet technologies and new rotor topologies to improve mechanical strength and achieve power targets. The three variants were a HRE-free permanent magnet reluctance motor, a synchronous reluctance motor utilizing small HRE-free permanent magnets, and an induction motor with inserted copper bars and cast aluminum end-rings. Motors were designed with the intent of primary or secondary traction applications, depending on the topology. Variant 1 achieved performance comparable to HRE-containing permanent magnet motors through optimized topology and validation of HRE-free magnets, focusing on achieving energy products and demagnetization resistance comparable to those of HRE-containing magnets. Demagnetization testing demonstrated the motor robustness to currents and temperatures exceeding expected vehicle conditions, a key challenge to the use of HRE-free magnets. The Variant 1 motor also showed the best capability of meeting the US Drive technology 2020 targets, due to the high power-density of the permanent magnet motor and the potential cost reductions enabled by the removal of heavy rare earth materials. Variant 2 exhibited high efficiency in high speed regions due to the low high-speed losses, an important consideration for secondary traction applications, and significantly thrifted on magnet mass to reduce cost. Variant 3 contained copper bars within the induction rotor to reduce losses compared to cast aluminum, while using cast aluminum end-rings to reduce the cost and mass of the rotor. Optimization of the Cu-Al interface were focused on, as the interface is prone to forming brittle intermetallic compounds during the casting process. Prototypes of each motor variant were built and tested for performance, mechanical strength, and demagnetization resistance (Variants 1 and 2 only), with torque and power resulting close to the predicted values.

33 ADVANCED PROPULSION SYSTEMS↗

Three-pole wigglers at NSLS-II

The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. Here, this paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.

36 MATERIALS SCIENCE↗

New Approach and Test Facility for High Field Accelerator Magnets R&D

This paper presents a new approach for developing and demonstrating high field magnet technology based on a magnet and test facility developed specifically for it. The traditional approach for carrying out high field magnet R&D has been building a new magnet to demonstrate a new design, new material or new technology. However, building a high field magnet is time consuming and expensive. To overcome this limitation, Brookhaven National Laboratory (BNL) built and successfully tested a 10 T Nb 3 Sn dipole DCC017 with large enough open or clear space (31 mm wide and 338 mm high) so that a pair of racetrack coils could be inserted into this opening without disassembling the magnet. The motivation be-hind this design was to facilitate a magnet R&D program where the new coils (with a large range in width and height accommodated) would reside in a high field region in direct contact with the existing coils (just as other magnet coils) and thus become an integral part of the magnet. We summarize the approach, the magnet, the test facility, past experiences, current and future test plans and planned up-grade. Here, the magnet facility is now available to service the needs of the wider community for testing cable and insert coils in a back-ground field of up to 10 T.

43 PARTICLE ACCELERATORS↗

Emergent ferromagnetism and unusual irreversible magnetoresistance in an intercalated van der Waals antiferromagnet

Orthorhombic air-stable two-dimensional (2D) antiferromagnet (AFM) CrSBr has attracted much research interest lately thanks to its rich magnetic behaviors together with its remarkable electronic, excitonic, and polaritonic properties. Here, we report a reliable electrochemical intercalation method by inserting large tetrabutylammonium (TBA + ) ions into CrSBr layers. Magnetically, such intercalation efficiently suppresses the interlayer AFM and induces a ferromagnetic (FM) order with a much-enhanced transition temperature up to 200 K, nearly 70 K higher than the AFM onset of 132 K in pristine CrSBr. Electronically, the TBA + intercalation not only increases the electric conductivity of CrSBr, which is further enhanced by magnetic fields, but also introduces a giant negative irreversible magnetoresistance. This work demonstrates the tunable magnetic and electronic properties of CrSBr as well as their interplay, paving the way for advanced spintronic and magnetic memory devices.

36 MATERIALS SCIENCE↗

Scattering by a groove in an impedance plane

An analysis of two-dimensional scattering from a narrow groove in an impedance plane is presented. The groove is represented by a impedance surface and the problem reduces to that of scattering from an impedance strip in an otherwise uniform impedance plane. On the basis of this model, appropriate integral equations are constructed using a form of the impedance plane Green's functions involving rapidly convergent integrals. The integral equations are solved by introducing a single basis representation of the equivalent current on the narrow impedance insert. Both transverse electric (TE) and transverse magnetic (TM) polarizations are treated. The resulting solution is validated by comparison with results from the standard boundary integral method (BIM) and a high frequency solution. It is found that the presented solution for narrow impedance inserts can be used in conjunction with the high frequency solution for the characterization of impedance inserts of any given width.

Bindiganavale, Sunil↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Concurrence of quantum anomalous Hall and topological Hall effects in magnetic topological insulator sandwich heterostructures

The quantum anomalous Hall (QAH) effect is a consequence of non-zero Berry curvature in momentum space. The QAH insulator harbours dissipation-free chiral edge states in the absence of an external magnetic field. Yet, the topological Hall (TH) effect, a hallmark of chiral spin textures, is a consequence of real-space Berry curvature. Herein, by inserting a topological insulator (TI) layer between two magnetic TI layers, we realized the concurrence of the TH effect and the QAH effect through electric-field gating. The TH effect is probed by bulk carriers, whereas the QAH effect is characterized by chiral edge states. The appearance of the TH effect in the QAH insulating regime is a consequence of chiral magnetic domain walls that result from the gate-induced Dzyaloshinskii–Moriya interaction and occurs during the magnetization reversal process in the magnetic TI sandwich samples. The coexistence of chiral edge states and chiral spin textures provides a platform for proof-of-concept dis- sipationless spin-textured spintronic applications.

36 MATERIALS SCIENCE↗

Improving Longitudinal Impedance of Inductive Inserts

In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.

43 PARTICLE ACCELERATORS↗

Design of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade Project

Here as part of the U.S. contribution to the HL-LHC Accelerator Upgrade Project (AUP), Fermilab is designing and building cold masses suitable for use in the LHC interaction regions. The cold mass provides a vacuum-tight helium enclosure for the magnets. Two magnets are aligned both axially and in cross section at Fermilab based on survey and warm magnetic measurements. Bus work and instrumentation is added. A welded stainless steel vacuum-tight shell surrounds the two magnets, and the structure is prepared for insertion into the cryostat. This paper summarizes the design of the cold mass including alignment, bus work, weld details, and instrumentation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D Mechanical Analysis of a Compact Nb 3 Sn IR Quadrupole for EIC

Abstract-The Electron Ion Collider (EIC) will require large aperture quadrupole magnets for the Hadron beam in the insertion region. Key requirements include high field, compact size, and tight control of the fringe fields. A 120 mm aperture, 308.4 mm outer diameter actively shielded Nb 3 Sn quadrupole model is under development to support these goals. This work is being carried out by a collaboration of BNL, JLAB and LBNL. A compact shell-based structure preloaded with a bladder and key system was developed for this project. In this paper, the effect of the compact structure on the mechanical behavior was investigated. In particular, the impact of the assembly tolerances and coil size variations on the actual coil stresses and bladder pressures was computed and compared with results from larger bladder and key structures developed for the LHC IR. The longitudinal preload is provided by stainless steel rods. Differently from other bladder and key magnets, the rods are first preloaded axially before coil axial load is applied. This new design aims to increase the overall stiffness of the system and reduce the longitudinal coil displacement during powering. Based on the results of a 3D mechanical analysis, the preliminary preload targets for the EIC quadrupole assembly will be reviewed and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Viking magnetic properties experiment - Extended mission results

The backhoe magnets on Viking Lander (VL) 2 were successfully cleaned, followed by a test involving successive insertions of the cleaned backhoe into the surface. Rapid saturation of the magnets confirmed evidence from primary mission results that the magnetic mineral in the Martian surface is widely distributed, most probably in the form of composite particles of magnetic and nonmagnetic minerals. An image of the VL 2 backhoe taken via the X4 magnifying mirror demonstrates the fine-grained nature of the attracted magnetic material. The presence of maghemite and its occurrence as a pigment in, or a thin coating on, all mineral particles or as discrete, finely divided and widely distributed crystallites, are consistent with data from the inorganic analysis experiments and with laboratory simulations of results of the biology experiments on Mars.

Hargraves, R. B.↗

Hinged, Magnetic Holder For Radiographic Film

Hinged holder equipped with magnets enables positive, accurate, and repeatable placement and orientation of radiographic film at hidden and otherwise inaccessible location. Made from simple, readily available parts. Film and holder inserted in end of duct and pulled along by magnets on outside. Holder removed by reversing sequence of motions.

Pierce, Darryl E.↗