Sub-Sampled Imaging for STEM: Maximising Image Speed, Resolution and Precision Through Reconstruction Parameter Refinement

Sub-sampling during image acquisition in scanning transmission electron microscopy (STEM) has been shown to provide a means to increase the overall speed of acquisition while at the same time providing an efficient means to control the dose, dose rate and dose overlap delivered to the sample. In this paper, we discuss specifically the parameters used to reconstruct sub-sampled images and highlight their effect on inpainting using the beta-process factor analysis (BPFA) methodology. The selection of the main control parameters can have a significant effect on the resolution, precision and sensitivity of the final inpainted images, and here we demonstrate a method by which these parameters can be optimised for any image in STEM. As part of this paper, we also provide a link to open source code and a tutorial on its use, whereby these parameters can be tested for any datasets. When coupled with the hardware necessary to rapidly sub-sample images in STEM, this approach can have significant implications for imaging beam sensitive materials and dynamic processes.

47 OTHER INSTRUMENTATION↗

Mechanochemical synthesis and intercalation of Ca(II)Fe(III)-layered double hydroxides

A mechanochemical method (grinding the components without added water – dry grinding, followed by further grinding in the presence of minute amount of water or NaOH solution – wet grinding) was used in this work for the preparation and intercalation of CaFe-layered double hydroxides (LDHs). Both the pristine LDHs and the amino acid anion (cystinate and tyrosinate) intercalated varieties were prepared by the two-step grinding procedure in a mixer mill. By systematically changing the conditions of the preparation method, a set of parameters could be determined, which led to the formation of close to phase-pure LDH. The optimisation procedure was also applied for the intercalation processes of the amino acid anions. The resulting materials were structurally characterised by a range of methods (X-ray diffractometry, scanning electron microscopy, energy dispersive analysis, thermogravimetry, X-ray absorption and infra-red spectroscopies). It was proven that this simple mechanochemical procedure was able to produce complex organic–inorganic nanocomposites: LDHs intercalated with amino acid anions. - Graphical abstract: Amino acid anion-Ca(II)Fe(III)-LDHs were successfully prepared by a two-step milling procedure. - Highlights: • Synthesis of pristine and amino acid intercalated CaFe-LDHs by two-step milling. • Identifying the optimum synthesis and intercalation parameters. • Characterisation of the samples with a range of instrumental methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and characterization of a multiple-coincidence ion-momentum imaging spectrometer

The design and performance of a high-resolution momentum-imaging spectrometer for ions which is optimized for experiments using synchrotron radiation is presented. High collection efficiency is achieved by a focusing electrostatic lens; a long drift tube improves mass resolution and a position-sensitive detector enables measurement of the transverse momentum of ions. The optimisation of the lens for particle momentum measurement at the highest resolution is described. We discuss the overall performance of the spectrometer and present examples demonstrating the momentum resolution for both kinetics and for angular measurements in molecular fragmentation for carbon monoxide and fullerenes. Examples are presented that confirm that complete space-time focussing is possible for a two-field three-dimensional imaging spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimisation of frequency-modulated characteristics of output radiation in a lidar with Raman amplification

The reported study is aimed at increasing the power in the transmission path of a lidar with Raman amplification for longpath sensing of methane by optimising the frequency-modulated characteristics of the output radiation. The pump current of the used distributed-feedback master laser was modulated by a linearfrequency signal with simultaneous application of a non-synchronous high-frequency signal. For such a modulation regime, the Raman amplifier provided the mean output power of 2.5 W at a wavelength of 1650 nm. The spectral broadening did not significantly decrease the lidar sensitivity at long paths. (lidars)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing collisions of magnetized, high energy density plasma flows using a combination of collective Thomson scattering, Faraday rotation, and interferometry (invited)

A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7–14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medical Radiation Dosimetry: Concepts and Needs

Radiation is used widely used in medicine for diagnostic and therapeutic applications. Both the desired effects and the potential detrimental side effects depend on the radiation dose delivered. As such it is essential to determining the radiation dose received by patients as accurately as needed to optimise the radiation procedure. Solid state dosimeters are increasingly used in medicine because of their small physical size, high sensitivity and usually low cost. Combining multiple detectors allows the detection of radiation dose distributions, an application where the distinction between radiation dosimeter and image detector starts to blur. Given the rapid development of detector technology it can be expected that the utilisation of solid-state dosimeters in medicine will continue to increase.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimisation of an acoustically antiguiding structure for raising the stimulated Brillouin scattering threshold in optical fibres

Optical fibres having a radially nonuniform acoustically antiguiding structure produced by codoping their core with alumina and germania have been fabricated and investigated. The influence of the shape of the antiguiding acoustic refractive index profile and fibre core diameter on the stimulated Brillouin scattering (SBS) threshold and spectrum in the fibres has been assessed. An increase in SBS threshold by 4.4 dB with respect to a germanosilicate fibre having the same mode field diameter has been demonstrated. (optical fibres)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimisation of wide-band parametric amplification stages of a femtosecond laser system with coherent combining of fields

For the first time the pulses with the energy of ∼150 mJ and the spectrum corresponding to the transform-limited duration of ∼20 fs amplified in three-stage parametric amplifiers have been coherently combined in a dual-channel femtosecond laser system. The efficiency of coherent combining of above 90% has been obtained at the residual relative time jitter of amplified pulses of 110 as. For the first time the modulation of spectrum was experimentally observed under the parametric amplification of a wideband femtosecond radiation in crystals placed in series. The model of parametric luminescence evolution was developed which allows one to calculate the whole range of the frequency-angular spectrum that, in addition to simulations of the contrast of amplified pulses, gives the possibility of optimising the amplifier efficiency. The results of experiments on measuring the contrast are presented and compared with the calculated data. Methods for enhancing the contrast in the created laser system are analysed. Possible schemes of multibeam pumping of the output cascade are considered for obtaining a petawatt power in the laser system based on cascades of a parametric amplifier in LBO crystals which is being developed at the Institute of Laser Physics of SB RAS. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of Rapid Assay Systems for Real-time Sorting of Excavation Spoil on Contaminated Land - 19258

To optimise segregation at source, and hence minimise waste production, NUVIA have developed and utilised the Gamma Excavation Monitor (GEM) system. The GEM was designed for land remediation projects, to provide a rapid screening tool for excavator buckets of material. Following successful deployment in the UK, including the Olympic Park site in London, and two major Magnox land remediation projects, the first GEM unit was deployed to Canadian Nuclear Laboratories' (CNL) Chalk River Laboratory (CRL) in 2016. The GEM unit was fitted with a plastic scintillator detector; recent developments have included the utilisation of a sodium iodide. The system is initiated by the presence of an excavator bucket above the detector which triggers proximity switches that automatically start the counting routine. At the end of a short count time, typically 10 seconds, the materials category is indicated by means of a traffic light system, based on either the gross gamma activity or a photo-peak. Using this instrument, material determined not to be radioactive can be re-used on-site. In addition to the traffic light system, results are also transmitted wirelessly to a tablet device. These combined features allow operation of the system without the need to have operatives near the mechanical excavator bucket; therefore, eliminating a significant industrial hazard. Deployments of the GEM on the CRL site have included Storm Water Management project, within the CRL controlled area, and the Foundation Road Landfill Project. The use of the GEM in these projects enabled in-situ decisions to be made regarding the segregation and sentencing of soil rather than having to wait for the analysis of samples; saving time and cost to the project. The Building 492 project involved the excavation of soil within a supervised area to prepare for the installation of modular trailer units. For this specific job, the GEM was calibrated to ensure soil met clearance criteria as stipulated in the Nuclear Substances and Radiation Devices Regulations (Canadian Nuclear Safety Commission; SOR/2000-207). A total of 326 loads of soil were monitored during this project and re-assurance sampling conducted by CNL corroborated the results produced by the GEM system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The development of the NNBAR experiment

The NNBAR experiment for the European Spallation Source will search for free neutrons converting to antineutrons with a sensitivity improvement of three orders of magnitude compared to the last such search. This paper describes progress towards a conceptual design report for NNBAR. The design of a moderator, neutron reflector, beamline, shielding and annihilation detector is reported. The simulations used form part of a model which will be used for optimisation of the experiment design and quantification of its sensitivity.

47 OTHER INSTRUMENTATION↗

Study of laser megajoule calorimeter's thermal behaviour for energy measurement uncertainty optimisation

For laser megajoule (LMJ) facility, an accurate procedure for laser pulse energy measurement is a crucial requirement. In this study, the influence of measurement procedure on LMJ calorimeter uncertainty is experimentally and numerically investigated. To this end, a 3D thermal model is developed and two experimental techniques are implemented. The metrological characteristics of both techniques are presented. As a first step, the model is validated by comparing numerical and experimental results. Then, the influence of a large number of parameters considered as likely uncertainty sources on calorimeter response is investigated: wavelength, pulse duration, ambient temperature, laser beam diameter Horizontal-Ellipsis . The post processing technique procedure is also examined. The paper provides some of the parameters required to allow a robust and efficient calibration procedure to be produced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kubernetes for the Deep Underground Neutrino Experiment Data Acquisition

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino experiment based in the USA which is expected to start taking data in 2029. DUNE aims to precisely measure neutrino oscillation parameters by detecting neutrinos from the LBNF beamline (Fermilab) at the Far Detector, 1,300 kilometres away, in South Dakota at the Sanford Underground Research Facility. The Far Detector will consist of four cryogenic Liquid Argon Time Projection Chamber detectors of 17 kT, each producing more than 1 TB/sec of data. The main requirements for the data acquisition system are the ability to run continuously for extended periods of time, with a 99% up-time requirement, and the functionality to record both beam neutrinos and low energy neutrinos from the explosion of a neighbouring supernova, should one occur during the lifetime of the experiment. The key challenges are the high data rates that the detectors generate and the deep underground environment, which places constraints on power and space. To overcome these challenges, DUNE plans to use a highly optimised C++ software suite and a server farm of about 110 nodes continuously running about two hundred multicore processes located close to the detector, 1.5 kilometres underground. Thirty nodes will be at the surface and will run around two hundred processes simultaneously. DUNE is studying the use of the Kubernetes framework to manage containerised workloads and take advantage of its resource definitions and high up-time services to run the DAQ system. Progress in deploying these systems at the CERN neutrino platform on the prototype DUNE experiments is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large volume high-pressure cell for inelastic neutron scattering

Inelastic neutron scattering measurements typically require two orders of magnitude longer data collection times and larger sample sizes than neutron diffraction studies. Inelastic neutron scattering measurements on pressurised samples are particularly challenging since standard high-pressure apparatus restricts sample volume, attenuates the incident and scattered beams, and contributes background scattering. Here, we present the design of a large volume two-layered piston-cylinder pressure cell with optimised transmission for inelastic neutron scattering experiments. The design and the materials selected for the construction of the cell enable its safe use to a pressure of 1.8 GPa with a sample volume in excess of 400 mm{sup 3}. The design of the piston seal eliminates the need for a sample container, thus providing a larger sample volume and reduced absorption. The integrated electrical plug with a manganin pressure gauge offers an accurate measurement of pressure over the whole range of operational temperatures. The performance of the cell is demonstrated by an inelastic neutron scattering study of UGe{sub 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Requirements on the gain calibration for LiteBIRD polarisation data with blind component separation

The detection of primordial B modes of the cosmic microwave background (CMB) could provide information about the early stages of the Universe's evolution. The faintness of this signal requires exquisite calibration accuracy and control of instrumental systematic effects which otherwise could bias the measurements. In this work, we study the impact of an imperfect relative polarisation gain calibration on the recovered value of the tensor-to-scalar ratio r for the LiteBIRD experiment, through the application of the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. We derive requirements on the relative calibration accuracy of the overall polarisation gain (Δg ν ) for each LiteBIRD frequency channel. Our results show that minimum variance techniques, as NILC, are less sensitive to systematic gain calibration uncertainties compared to a parametric approach, if the latter is not equipped with a proper modelling of these instrumental effects. In this study, the most stringent requirements are found in the channels where the CMB signal is relatively brighter, with the tightest constraints at 166 GHz (Δg ν ≈ 0.16%). This differs from the outcome of an analogous analysis performed with a parametric method, where the tightest requirements are obtained for the foreground-dominated channels. Gain calibration uncertainties, corresponding to the derived requirements, are then simultaneously propagated into all frequency channels. By doing so, we find that the overall impact on estimated r is lower than the total gain systematic budget for LiteBIRD approximately by a factor 5, due to the correlations of the impacts of gain calibration uncertainties in different frequency channels. In order to decouple the systematic effect from the specific choice of the model, we derive the requirements assuming constant spectral parameters for the foreground emission. To assess the robustness of the obtained results against more realistic scenarios, we repeat the analysis assuming sky models of intermediate and high complexity. In these further cases, we adopt an optimised NILC pipeline, called the Multi-Clustering NILC (MC-NILC). We find that the impact of gain calibration uncertainties on r is lower than the LiteBIRD gain systematics budget for the intermediate-complexity sky model. For the high-complexity case, instead, it would be necessary to tighten the requirements by a factor 1.8.

79 ASTRONOMY AND ASTROPHYSICS↗

Interstellar laser communication: implementability criterion and optimisation conditions for the addressed signal search and sending

Using new opportunities offered by the construction of large optical telescopes, a laser radiation receiver with an iodine active quantum filter, high-energy iodine lasers with a diffraction-limited beam divergence and the discovery of exoplanets of the Earth type, including those located relatively not far from the Sun, we analyse the implementability of interstellar laser communication under the conditions, when the central spot of the diffraction pattern at the place of the laser signal reception by means of large optical telescopes can be made smaller than the orbit of the planet, and the signals come to the specified point of the orbit not synchronously with the planet motion because of the error in the determination of the distance between the Sun and the star, around which the planet chosen for communication rotates. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The International Linear Collider. A Global Project

A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal to and complements the LHC physics program. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. Polarised electron and positron beams add unique opportunities to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The key accelerator technology, superconducting radio-frequency cavities, has matured. Optimised collider and detector designs, and associated physics analyses, were presented in the ILC Technical Design Report, signed by 2400 scientists. There is a strong interest in Japan to host this international effort. A detailed review of the many aspects of the project is nearing a conclusion in Japan. Now the Japanese government is preparing for a decision on the next phase of international negotiations, that could lead to a project start within a few years. The potential timeline of the ILC project includes an initial phase of about 4 years to obtain international agreements, complete engineering design and prepare construction, and form the requisite international collaboration, followed by a construction phase of 9 years.

43 PARTICLE ACCELERATORS↗

The Low Energy Neutrino Factory

We show that a low energy neutrino factory with a baseline of 1300 km and muon energy of 4.5 GeV has an excellent physics reach. The results of our optimisation studies demonstrate that such a setup can have remarkable sensitivity to theta{sub 13} and delta for sin{sup 2}(2theta{sub 13})>10{sup -4}, and to the mass hierarchy for sin{sup 2}(2theta{sub 13})>10{sup -3}. We also illustrate the power of the unique combination of golden and platinum channels accessible to the low energy neutrino factory. We have considered both a 20 kton totally active scintillating detector and a 100 kton liquid argon detector as possible detector technologies, finding that a liquid argon detector with very good background rejection can produce sensitivity to theta{sub 13} and delta with that of the International Design Study neutrino factory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗