Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumental resolution function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Stronger field-emission science via coupling novel nanoscale imaging techniques

We implemented a vacuum field emission electron microscope (FEM) using the electron optics of a low-energy /photoemission electron microscope (LEEM/PEEM). Historically, there have been other FEM hardware platforms, and the distinctive feature of our method is that it integrates with the LEEM/PEEM and associated techniques, enabling a powerful multi-capability toolset for studying fundamental materials properties underpinning field emission (FE) and vacuum arc initiation. Typically, LEEM is used to image surface structure, which influences both work function and electric field distribution near a surface, while PEEM is used to map photoelectric work function across a surface. Our FEM adds the capability for spatially-correlated coincident-site measurements of FE currents to go-along with structure and work function. LEEM, PEEM, and our FEM implementation achieve nanoscale spatial resolution relevant for materials studies in nanoscience/engineering. Our approach requires a straightforward calibration of the electron optics to enable focused FEM imaging under intentional electric field variation. We demonstrate the FEM approach by imaging field emitter arrays relevant for vacuum nanoelectronics. We demonstrate submicron spatial resolution and dynamic measurement of FE versus applied electric field. We anticipate this capability will enable fundamental structure-function studies of FE and arc initiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote sensing from unoccupied aerial systems: Opportunities to enhance Arctic plant ecology in a changing climate

The Arctic is warming at a faster rate than any other biome on Earth, resulting in widespread changes in vegetation composition, structure, and function that have important feedbacks to the global climate system. The heterogeneous nature of arctic landscapes creates challenges for monitoring and improving understanding of these ecosystems, as current efforts typically rely on ground, airborne, or satellite-based observations that are limited in space, time, or pixel resolution. The use of remote sensing instruments on small Unoccupied Aerial Systems (UASs) has emerged as an important tool to bridge the gap between detailed, but spatially limited ground-level measurements, and lower resolution, but spatially extensive high-altitude airborne and satellite observations. UASs allow researchers to view, describe and quantify vegetation dynamics at fine spatial scales (1-10 cm) over areas much larger than typical field plots. UASs can be deployed with a high degree of temporal flexibility, enabling observation across diurnal, seasonal, and annual timescales. In this work, we review how established and emerging UAS remote sensing technologies can enhance arctic plant ecological research by quantifying fine-scale vegetation patterns and processes, and by enhancing the ability to link ground-based measurements with broader-scale information obtained from airborne and satellite platforms. Synthesis: Improved ecological understanding and model representation of arctic vegetation is needed to forecast the fate of the Arctic in a rapidly changing climate. Observations from UASs provide an approach to address this need, however, the use of this technology in the Arctic currently remains limited. Here we share recommendations to better enable and encourage the use of UASs to improve the description, scaling, and model representation of arctic vegetation.

54 ENVIRONMENTAL SCIENCES↗

Satellite solar-induced chlorophyll fluorescence and near-infrared reflectance capture complementary aspects of dryland vegetation productivity dynamics

Mounting evidence indicates dryland ecosystems play an important role in driving the interannual variability and trend of the terrestrial carbon sink. Nevertheless, our understanding of the seasonal dynamics of dryland ecosystem carbon uptake through photosynthesis [gross primary productivity (GPP)] remains relatively limited due in part to the limited availability of long-term data and unique challenges associated with satellite remote sensing across dryland ecosystems. Here, we comprehensively evaluated longstanding and emerging satellite vegetation proxies in their ability to capture seasonal dryland GPP dynamics. Specifically, we evaluated: 1) reflectance-based proxies normalized difference vegetation index (NDVI), soil adjusted vegetation index (SAVI), near infrared reflectance index (NIR v ), and kernel NDVI (kNDVI) from the MODerate resolution Imaging Spectroradiometer (MODIS); and 2) newly available physiologically-based proxy solar-induced chlorophyll fluorescence (SIF) from the TROPOspheric Monitoring Instrument (TROPOMI). As a performance benchmark, we used GPP estimates from a robust network of 21 western United States eddy covariance tower sites that span representative gradients in dryland ecosystem climate and functional composition. We found that NIR v and SIF were the best performing GPP proxies and captured complementary aspects of seasonal GPP dynamics across dryland ecosystem types. NIR v offered better performance than the other proxies across relatively low-productivity, sparsely non-evergreen vegetated sites (R 2 = 0.59 ± 0.13); whereas SIF best captured seasonal dynamics across relatively high-productivity sites, including evergreen-dominated sites (R 2 = 0.74 ± 0.07). Notably, across grass-dominated sites, all reflectance-based proxies (NDVI, SAVI, NIRv and kNDVI) showed significant seasonal bias (hysteresis) that strengthened with the total fraction of woody vegetation cover, likely due to seasonal patterns in woody vegetation reflectance that are unrelated to or decoupled from GPP. In conclusion, future efforts to fully integrate the complementary strengths of NIR v and SIF could significantly improve our understanding and representation of dryland GPP dynamics in satellite-based models.

54 ENVIRONMENTAL SCIENCES↗

Bistatic Synthetic Aperture Radar - Issues Analysis and Design

The physical separation of the transmitter from the receiver into perhaps separate flight vehicles (with separate flight paths) in a bistatic Synthetic Aperture radar system adds considerable complexity to an already complex system. Synchronization of waveform parameters and timing attributes become problematic, and notions of even the synthetic aperture itself take on a new level of abstractness. Consequently, a high-performance, fine-resolution, and reliable bistatic SAR system really needs to be engineered from the ground up, with tighter specifications on a number of parameters, and entirely new functionality in other areas. Nevertheless, such a bistatic SAR system appears viable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Particle_hygroscopicity_growth_factor_HFIMS_TRACER_2022_HOUSTON_IOP

This dataset contains high-temporal-resolution measurements of hygroscopic growth factors (GF), and instrument diagnostic/environmental parameters collected during the TRACER campaign using a coupled Differential Mobility Analyzer (DMA) and Fast Integrated Mobility Spectrometer (FIMS) system (HFIMS). The dataset consists of 49,645 time steps and covers 20 discrete growth factor bins (FIMS_GFbinc). The primary data product is the Probability Density Function (FIMS_cPDF), which characterizes aerosol hygroscopic growth behavior under controlled relative humidity conditions. Instrument operational parameters, including flow temperatures, relative humidities, pressures, and counts for both DMA and FIMS, are provided for quality assurance.

DMA_Dp_mean↗

Two-Dimensional Thomson Scattering in Laser-Produced Plasmas

We present two-dimensional (2D) optical Thomson scattering measurements of electron density and temperature in laser-produced plasmas. The novel instrument directly measures ne(x,y) and Te(x,y) in two dimensions over large spatial regions (cm2) with sub-mm spatial resolution, by automatically translating the scattering volume while the plasma is produced repeatedly by irradiating a solid target with a high-repetition-rate laser beam (10 J, ∼1012 W/cm2, 1 Hz). In this paper, we describe the design and motorized auto-alignment of the instrument and the computerized algorithm that autonomously fits the spectral distribution function to the tens-of-thousands of measured scattering spectra, and captures the transition from the collective to the non-collective regime with distance from the target. As an example, we present the first 2D scattering measurements in laser-driven shock waves in ambient nitrogen gas at a pressure of 0.13 mbar.

Zhang, Haiping (ORCID:0009000228133852)↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Measuring the Conditional Luminosity and Stellar Mass Functions of Galaxies by Combining the Dark Energy Spectroscopic Instrument Legacy Imaging Surveys Data Release 9, Survey Validation 3, and Year 1 Data

In this investigation, we leverage the combination of the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys Data Release 9, Survey Validation 3, and Year 1 data sets to estimate the conditional luminosity functions and conditional stellar mass functions (CLFs and CSMFs) of galaxies across various halo mass bins and redshift ranges. To support our analysis, we utilize a realistic DESI mock galaxy redshift survey (MGRS) generated from a high-resolution Jiutian simulation. An extended halo-based group finder is applied to both MGRS catalogs and DESI observation. By comparing the r- and z-band luminosity functions (LFs) and stellar mass functions (SMFs) derived using both photometric and spectroscopic data, we quantified the impact of photometric redshift (photo-z) errors on the galaxy LFs and SMFs, especially in the low-redshift bin at the low-luminosity/mass end. By conducting prior evaluations of the group finder using MGRS, we successfully obtain a set of CLF and CSMF measurements from observational data. We find that at low redshift, the faint-end slopes of CLFs and CSMFs below ~10 9 h –2 L ⊙ (or h –2 M ⊙ ) evince a compelling concordance with the subhalo mass functions. After correcting the cosmic variance effect of our local Universe following Chen et al., the faint-end slopes of the LFs/SMFs turn out to also be in good agreement with the slope of the halo mass function.

79 ASTRONOMY AND ASTROPHYSICS↗

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

Experimental and Computational Evaluation of Lipidomic In-Source Fragmentation as a Result of Postionization with Matrix-Assisted Laser Desorption/Ionization

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) can provide spatially resolved molecular information about a sample. Recently, a postionization approach (MALDI-2) has been commercially integrated with MALDI-MSI, allowing for bettered sensitivity and consequent improved spatial resolution. While advantages of MALDI-2 have previously been established, we demonstrate here statistically increased in-source fragmentation (ISF) results from postionization with a commercial instrument. Via lipid standard analyses, known MALDI ISF pathways (e.g., loss of trimethylamine) were statistically increased in MALDI-2 compared to MALDI-1 (65–172% increase in fragmentation). Gas phase molecular modeling with density functional theory estimated that the most-weighted virtual orbitals to excite within lipids involve ester and phosphate bonds. Protonated lipid excitation energies are furthermore red-shifted compared to those of other adduct types [e.g., 254 nm for protonated PC(16:0/18:1)] and approach the MALDI-2 laser energy (266 nm). Analysis of rat brain homogenate detected statistically more positive-ion mode peaks with MALDI-2 (1090) than that with MALDI-1 (719), where Kernel density estimations showed that the majority of this enhancement occurs with low m/z ions (i.e., m/z 75–500). Taken together with the lipid standard data, these observations may indicate ISF due to postionization. Finally, while artifact contributions from matrix blanks were also noted, both experimental and computational data sets suggest that the overall extent of ISF is statistically increased in MALDI-2 compared to MALDI-1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

LensingETC: A Tool to Optimize Multifilter Imaging Campaigns of Galaxy-scale Strong Lensing Systems

Imaging data is the principal observable required to use galaxy-scale strong lensing in a multitude of applications in extragalactic astrophysics and cosmology. In this paper, we develop Lensing Exposure Time Calculator (LensingETC; to optimize the efficiency of telescope-time usage when planning multifilter imaging campaigns for galaxy-scale strong lenses. This tool simulates realistic data tailored to specified instrument characteristics and then automatically models them to assess the power of the data in constraining lens model parameters. We demonstrate a use case of this tool by optimizing a two-filter observing strategy (in the IR and ultraviolet-visual (UVIS)) within the limited exposure time per system allowed by a Hubble Space Telescope (HST) Snapshot program. We find that higher resolution is more advantageous to gain constraining power on the lensing observables, when there is a trade-off between signal-to-noise ratio and resolution; for example, between the UVIS and IR filters of the HST. We also find that, whereas a point-spread function (PSF) with sub-Nyquist sampling allows the sample mean for a model parameter to be robustly recovered for both galaxy–galaxy and point-source lensing systems, a sub-Nyquist-sampled PSF introduces a larger scatter than a Nyquist-sampled one in the deviation from the ground truth for point-source lens systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Desmearing Bonse–Hart USANS data using Bayesian Gaussian process regression

Ultra-small-angle neutron scattering (USANS) enables access to micrometer-scale structures but is intrinsically affected by strong, anisotropic resolution smearing arising from slit-geometry optics. As a result, recovery of the intrinsic scattering intensity constitutes an ill-posed inverse problem, and commonly used iterative desmearing methods lack rigorous uncertainty quantification. We present a Bayesian desmearing framework for slit-geometry USANS based on Gaussian process regression. In this approach, the scattering intensity is modeled as a smooth random function, and the instrumental point spread function is incorporated explicitly as a forward operator. The resulting formulation yields a closed-form maximum a posteriori solution with well-defined credibility intervals. Computational benchmarks and experimental validation using combined USANS and small-angle neutron scattering (SANS) measurements demonstrate that the framework enables stable desmearing, suppresses experimental noise, and preserves physically meaningful structural features under realistic conditions.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Agilent CRADA (Abstract)

The CRADA between Agilent Technologies Inc. and Battelle will focus on five software components as listed below: Prototype 4D Feature Finding functionality with a particular focus on recovering low level features and extending the bottom end dynamic range of IM-MS technology. Compare and contrast developments to current 4D Feature Finding capabilities. Highlight important algorithmic aspects employed. Implement the PNNL saturation correction algorithm. Agilent will give PNNL the needed data file access API and assistance in understanding it implementation and any needed instrumental aspects. Supported high resolution products to include Agilent’s TOF, QTOF and IM-QTOF mass spectrometers. PNNL will then work with Agilent to benchmark performance. Implementation of the PNNL Hadamard de-multiplexing algorithm. Agilent will give provide PNNL the needed date file access API access and as needed assistance in understanding the current Agilent multiplexed IM offering. PNNL will then work with Agilent on benchmark performance. Add ion mobility collision cross sections to existing and new metabolomic libraries for data analysis with Agilent’s informatics program MPP/ID Browser. PNNL will work with Agilent to create a software pipeline that takes data from chemical and metabolic standards and properly formats it for inclusion in MPP accessible libraries, using the collision cross section as a new separation dimension. Improvements of MPP multidimensional matching to identify metabolomic features using multiple characteristics beyond retention time and accurate mass. Most significantly matching will include analyte collision cross section with proposed support for sample fraction or RapidFire cartridge and fragmentation spectra. PNNL will work with Agilent to modify and improve the current MPP analysis pipeline to allow for creating, aligning, and identifying MS features defined by accurate mass, collision cross section and chromatographic retention time. As additional criteria such as fraction or RapidFire cartridge type are supported in the identification process, then they also will become part of the automation workflow. This includes the automation of said system to work with command line program (i.e. not a GUI) sufficient for programmatic execution in a pipeline.

97 MATHEMATICS AND COMPUTING↗