Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrating sphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗

Calibration source for remote sensors

The source described was developed as a calibration target for the multispectral scanner (MSS) which was flown on the Earth Resources Technology Satellite A (LANDSAT 1). The wavelength region of interest covered the four (4) MSS bands extending from 0.5 to 1.1 micrometers, although the target was calibrated from 0.32 to 2.5 micrometers. The following characteristics for the target were required: (1) large aperture, sufficient to accommodate an instrument with a 9 inch (23 centimeters(cm)) aperture and 2 1/2 deg field of view (fov), (2) highly diffuse energy from target, (3) high spatial uniformity across aperture area of source, (4) spectrally calibrated in absolute units, (5) stable output over long periods of time (1-2 yrs), and (6) rugged, yet portable enough to be easily transported long distances without detrimental effects on the operational capabilities of the target. Two approaches were considered: a thirty (30) inch (76 cm) diameter integrating sphere with a twelve inch (30.5 cm) exit port, or the use of one hemisphere of a 76 cm sphere in conjunction with a Kodak ektolite screen. The screen has the property of reflecting back uniformly into a well defined area the majority of the light received. After some preliminary trials it seemed that the 76 cm sphere would give the most satisfactory results.

Mclean, J. T.↗

High temperature reflectance of hyperpure slip cast silica

An experimental program to optically characterize hyperpure slip cast silica at elevated temperatures is described. This sintered ceramic material is being used in the development of a reflective heat shield for the Outer Planet Entry Probe. A unique high temperature integrating sphere reflectometer is described and reflectance data in the spectral range 0.23-2.3 micron are presented at temperatures up to 1427 C in air and helium environments. Kubelka-Munk (K-M) scattering and absorptance coefficients (K and S), using the Reichman extension of the K-M theory, are presented as is a unique method of obtaining K and S from the Reichman equations using only reflectance data. The hyperpure slip cast silica material was found to retain its high diffuse reflectance at temperatures up to 1204 C, with slight degradation occurring at higher temperatures.

Dillow, C. F.↗

Optical properties of ion beam textured metals

Copper, silicon, aluminum, titanium and 316 stainless steel were textured by 1000 eV xenon ions from an 8 cm diameter electron bombardment ion source. Simultaneously sputter-deposited tantalum was used to facilitate the development of the surface microstructure. Scanning electron microscopy of the ion textured surfaces revealed two types of microstructure. Copper, silicon, and aluminum developed a cone structure with an average peak-to-peak distance ranging from 1 micron for silicon to 6 microns for aluminum. Titanium and 316 stainless steel developed a serpentine ridge structure. The average peak-to-peak distance for both of these materials was 0.5 micron. Spectral reflectance was measured using an integrating sphere and a holraum reflectometer. Total reflectance for air mass 0 and 2, solar absorptance and total emittance normalized for a 425 K black body were calculated from the reflectance measurements.

Hudson, W. R.↗

Optical and electrical properties of ion beam textured Kapton and Teflon

An electron bombardment argon ion source was used to ion etch polyimide (Kapton) and fluorinated ethylene, FEP (Teflon). Samples of polyimide and FEP were exposed to (0.5-1.0) keV Ar ions at ion current densities of (1.0-1/8) mA/sq cm for various exposure times. Changes in the optical and electrical properties of the samples were used to characterize the exposure. Spectral reflectance and transmittance measurements were made between 0.33 and 2.16 micron m using an integrating sphere after each exposure. From these measurements, values of solar absorptance were obtained. Total emittance measurements were also recorded for some samples. Surface resistivity was used to determine changes in the electrical conductivity of the etched samples. A scanning electron microscope recorded surface structure after exposure. Spectral optical data, resistivity measurements, calculated absorptance and emittance measurements are presented along with photomicrographs of the surface structure for the various exposures to Ar ions.

Mirtich, M. J.↗

An active thermal control surfaces experiment

An active flight experiment is described that has the objectives to determine the effects of the low earth natural environment and the Shuttle induced environment on selected thermal control and optical surfaces. The optical and thermal properties of test samples will be measured in-situ using an integrating sphere reflectrometer and using calorimetric methods. This experiment has been selected for the Long Duration Exposure Facility (LDEF) flight which will be carried to orbit by the NASA Space Shuttle. The LDEF will remain in orbit to be picked up by a later Shuttle mission and returned for postflight evaluation.

Wilkes, D. R.↗

Compact solar radiation simulator for the 400 to 1800 nm spectral region

A solar radiation simulator operating over the extended spectral range from 400 to 1800 nm is described. A source of Lambertian radiation over an extended spectral range similar to the extraterrestrial solar spectrum was required to test and calibrate the solar flux radiometer flown on the Pioneer-Venus mission. Available units did not feature the Lambertian target nor the extended spectral range. A source was designed and built using a tungsten-halogen lamp and a xenon arc, along with interference and absorption filters, and a BaSO4-coated integrating sphere. Readily available parts were used wherever possible. The spectral radiance of the test area and the calibration method are presented. The source can also be used with a quasi-collimated output beam of moderate uniformity.

Palmer, J. M.↗

Target reflectance measurements for calibration of lidar atmospheric backscatter data

Wavelength and angular dependence of reflectances and depolarization in the 9-11 micron region are reported for four standard targets: flowers of sulfur, flame-sprayed aluminum, 20-grit sandblasted aluminum, and 400-grit silicon carbon sandpaper. Measurements are presented and compared using a CW CO2 grating-tunable laser in a laboratory backscatter apparatus, an integrating sphere, and a coherent pulsed TEA-CO2 lidar system operating in the 9-11 micron region. Reflectance theory related to the use of hard targets to calibrate lidar atmospheric backscatter data is discussed.

Kavaya, M. J.↗

Atomic-oxygen stimulated outgassing (A0034)

The objective of this experiment is to determine if the impingement of atomic oxygen in near-Earth orbit is a major factor in producing optically damaging outgassed products. The expected results will be to obtain samples which have been exposed to atomic oxygen for long durations. Analysis of these samples will determine if the impingement of atomic oxygen on the thermal control surfaces stimulates a significant amount of outgassed products. This experiment will give a clearer picture of the contamination problem and will assist in assuring that future Shuttle payloads, such as the Space Telescope and High-Energy Astronomy Observatory, will not experience Skylab contamination levels. Selected thermal control surfaces will be exposed to the atomic oxygen in near-Earth orbit. Passive collecting samples will collect any induced outgassing resulting from oxygen impingement. The optical condition of the passive samples will be measured using a ground-based integrating sphere reflectometer and a directional reflectometer.

Scott, R. L., Jr.↗

Pre-launch Absolute Radiometric Calibration of LANDSAT-4 Protoflight Thematic Mapper

From both scientific and applications perspectives, the usefulness of TM digital imagery is significantly determined by its radiometric characteristics. This includes both the accuracy to which the dynamic range is known and its radiometric reproducibility or precision. Results from several pre-launch tests with a 122-cm Integrating Sphere (IS) used as part of the absolute radiometric calibration experiments for the protoflight TM sensor carried on the LANDSAT-4 satellite are summarized and analyzed. Topics covered include TM radiometric calibration and sensitivity; the TM internal calibrator; and the dynamic range after calibration.

Barker, J. L.↗

Prelaunch absolute radiometric calibration of the reflective bands on the LANDSAT-4 protoflight Thematic Mapper

The results of the absolute radiometric calibration of the LANDSAT 4 thematic mapper, as determined during pre-launch tests with a 122 cm integrating sphere, are presented. Detailed results for the best calibration of the protoflight TM are given, as well as summaries of other tests performed on the sensor. The dynamic range of the TM is within a few per cent of that required in all bands, except bands 1 and 3. Three detectors failed to pass the minimum SNR specified for their respective bands: band 5, channel 3 (dead), band 2, and channels 2 and 4 (noisy or slow response). Estimates of the absolute calibration accuracy for the TM show that the detectors are typically calibrated to 5% absolute error for the reflective bands; 10% full-scale accuracy was specified. Ten tests performed to transfer the detector absolute calibration to the internal calibrator show a 5% range at full scale in the transfer calibration; however, in two cases band 5 showed a 10% and a 7% difference.

Barker, J. L.↗

Prelaunch absolute radiometric calibration of LANDSAT-4 protoflight Thematic Mapper

Results are summarized and analyzed from several prelaunch tests with a 122 cm integrating sphere used as part of the absolute radiometric calibration experiments for the protoflight TM sensor carried on the LANDSAT-4 satellite. The calibration procedure is presented and the radiometric sensitivity of the TM is assessed. The internal calibrator and dynamic range after calibration are considered. Tables show dynamic range after ground processing, spectral radiance to digital number and digital number to spectral radiance values for TM bands 1, 2, 3, 4, 5, 7 and for channel 4 of band 6.

Barker, J. L.↗

Changes in spectral properties of detached leaves

If leaf senescence can be delayed for several days without significant changes in spectral properties, then samples of leaves at remote test sites could be prepared and shipped to laboratories to measure spectral properties. The changes in spectral properties of detached leaves were determined. Leaves from red birch and red pine were immersed in water or 0.001 M benzylaminopurine (BAP) and stored in plastic bags in the dark at either 5 or 25 C. Total directional-hemispherical reflectance and transmittance of the adaxial surface of birch leaves were measured over the 400 to 1100 nm wavelength region with a spectroradiometer and integrating sphere. Pine needles were taped together and reflectance of the mat of needles was measured. Spectral properties changed less than 5% of initial values during the first week when leaves were stored at 5 C. Storage at 25 C promoted rapid senescence and large changes in spectral properties. BAP delayed, but did not stop, senescence at 25 C.

Daughtry, C. S. T.↗

Spectroradiometric calibration of the Thematic Mapper and Multispectral Scanner system

The results of analyses of Thematic Mapper (TM) images acquired on July 8 and October 28, 1984, and of a check of the calibration of the 1.22-m integrating sphere at Santa Barbara Research Center (SBRC) are described. The results obtained from the in-flight calibration attempts disagree with the pre-flight calibrations for bands 2 and 4. Considerable effort was expended in an attempt to explain the disagreement. The difficult point to explain is that the difference between the radiances predicted by the radiative transfer code (the code radiances) and the radiances predicted by the preflight calibration (the pre-flight radiances) fluctuate with spectral band. Because the spectral quantities measured at White Sands show little change with spectral band, these fluctuations are not anticipated. Analyses of other targets at White Sands such as clouds, cloud shadows, and water surfaces tend to support the pre-flight and internal calibrator calibrations. The source of the disagreement has not been identified. It could be due to: (1) a computational error in the data reduction; (2) an incorrect assumption in the input to the radiative transfer code; or (3) incorrect operation of the field equipment.

Slater, P. N.↗

Changes in spectral properties of detached birch leaves

A study conducted in order to determine the rate of changes in spectral properties of detached leaves and to evaluate the effectiveness of low temperature and cytokinins for delaying the changes, is examined. For five minutes, leaves from red birch are immersed in water or 0.001 M BAP, and then stored in plastic bags in the dark at either 5 or 25 C. Using a spectroradiometer and an integrating sphere, total directional-hemispherical reflectance and transmittance of the adaxial surface of the leaves are measured over the 400-1100 nm wavelength region. The results indicate that for leaves stored at 5 C for one week, the changes in the spectral properties are less than 5 percent of the initial values, whereas storage at 25 C promotes rapid senescence and large changes in the spectral properties. It is shown that low temperature is more effective than BAP in delaying senescence.

Daughtry, C. S. T.↗

The internal reference source (IRS) for diffuse infrared background experiment (DIRBE)

A means is described for providing internal calibration for the detectors for DIRBE, which is the Diffuse Infrared Background Experiment (a part of the Cosmic Background Explorer). The internal reference source (IRS) that is used consists of four thermal graybody sources coupled to an integrating sphere. The relative insensitivity of the DIRBE bolometers and the linear temperature dependence of the Rayleigh-Jeans law made bolometer stimulation over five orders of magnitude difficult, so four different sources were used with emitting areas varying by a factor of 10 to the 8th. A low heat capacity design with the necessary stability appears to be thin nichrome films on a sapphire substrate. Voltage stability to 0.01 percent is required for those near infrared bands that required stimulation on the Wien portion of the blackbody curve.

Silverglate, P.↗

Investigation of hard targets for calibration of a coherent Doppler lidar system

The bihemispherical reflectance has been measured for a diffuse gold surface the same as the coating on the integrating sphere, flowers of sulfur, sandblasted aluminum, and 120 grade aluminum oxide sandpaper. The sandpaper measurements indicate that materials with low reflectance cannot be measured until more sensitive detection techniques are found. The sphere had to be used without a detector baffle so an unusual geometry was needed that led to a loss of intensity. Further, it is estimated that some first-strike light entered the detector and the readings could be 1 to 1.5% too low. A limited number of normal incident directional-hemispherical reflectance measurements were made on aluminum and sandpaper. Several recommendations are made: (1) the proper baffle placement; (2) improve lock-in detection using a PAR lock-in amplifier or the heterodyne technique; (3) modification of the sphere so the sample may be mounted at the cell center on a graduate, rotatable table for measurement of directional-hemispherical reflectance; (4) the purchase of additional diffuse gold samples with coatings like the sphere; and (5) better laser temperature control to improve intensity stability.

Anderson, Richard↗

Laser and sunlight-induced fluorescence from chlorophyll pigments

Fluorescence properties of chlorophyll pigment bearing plant foliage utilizing a 337 nm nitrogen laser and integrating sphere were studied. Measured yields, in terms of number of photons emitted per 100 photons absorbed, range from 1.5 to 0.1 for the 685 nm peak, and from 4.2 to 0.2 for the 730 nm peak. Decreasing order of magnitude puts herbaceous leaves ahead of all others followed by broad leaves of hardwoods and coniferous needles. Meaningful quantization for the fluorescence peaks at 430 and 530 nm could not be attained. Passive monitoring of these fluorescence peaks is successful only for the 685 nm from the ocean surface. Field data show the reflectance changes at 685 nm due to the algae presence amounts to 1% at most.

Kim, H. H.↗