Search NASA⌕ Search

SEARCH · Search NASA

Results for “intense”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photon acceleration of high-intensity vector vortex beams into the extreme ultraviolet

Extreme ultraviolet (XUV) light sources allow for the probing of bound electron dynamics on attosecond scales, interrogation of high-energy-density matter, and access to novel regimes of strong-field quantum electrodynamics. Despite the importance of these applications, coherent XUV sources remain relatively rare, and those that do exist are limited in their peak intensity and spatio-polarization structure. Here, we demonstrate that photon acceleration of an optical vector vortex pulse in the moving density gradient of an electron beam–driven plasma wave can produce a high-intensity, tunable-wavelength XUV pulse with the same vector vortex structure as the original pulse. Quasi-3D, boosted-frame particlein- cell simulations show the transition of optical vector vortex pulses with 800-nm wavelengths and intensities below 10 18 W/cm 2 to XUV vector vortex pulses with 36-nm wavelengths and intensities exceeding 10 20 W/cm 2 over a distance of 1.2 cm. The XUV pulses have sub-femtosecond durations and nearly flat phase fronts. The production of such high-quality, high-intensity XUV vector vortex pulses could expand the utility of XUV light as a diagnostic and driver of novel light–matter interactions.

43 PARTICLE ACCELERATORS↗

Transmission spectroscopy of CF 4 molecules in intense x-ray fields

The nonlinear interaction of x rays with matter is at the heart of understanding and controlling ultrafast molecular dynamics from an atom-specific viewpoint, providing new scientific and analytical opportunities to explore the structure and dynamics of small quantum systems. At increasingly high x-ray intensity, the sensitivity of ultrashort x-ray pulses to specific electronic states and emerging short-lived transient intermediates is of particular relevance for our understanding of fundamental multiphoton absorption processes. In this work, intense x-ray free-electron laser (XFEL) pulses at the European XFEL are combined with a gas cell and grating spectrometer for a high-intensity transmission spectroscopy study of multiphoton-induced ultrafast molecular fragmentation dynamics in CF 4 . This approach unlocks the direct intrapulse observation of transient fragments, including neutral atoms, by their characteristic absorption lines in the transmitted broadband x-ray spectrum. The dynamics with and without initially producing fluorine 𝐾-shell holes are studied by tuning the central photon energy. The absorption spectra are measured at different FEL intensities to observe nonlinear effects. Transient isolated fluorine atoms and ions are spectroscopically recorded within the ultrashort pulse duration of a few tens of femtoseconds. An isosbestic point that signifies the correlated transition between intact neutral CF 4 molecules and charged atomic fragments is observed near the fluorine 𝐾 edge. The dissociation dynamics and the multiphoton absorption-induced dynamics encoded in the spectra are theoretically interpreted. Overall, this study demonstrates the potential of high-intensity x-ray transmission spectroscopy to study ultrafast molecular dynamics with sensitivity to specific intermediate species and their electronic structure.

74 ATOMIC AND MOLECULAR PHYSICS↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

Real-time dynamic wavelength tuning and intensity modulation of metal-clad nanolasers

To realize ubiquitously used photonic integrated circuits, on-chip nanoscale sources are essential components. Subwavelength nanolasers, especially those based on a metal-clad design, already possess many desirable attributes for an on-chip source such as low thresholds, room-temperature operation and ultra-small footprints accompanied by electromagnetic isolation at pitch sizes down to ∼50 nm. Another valuable characteristic for a source would be control over its emission wavelength and intensity in real-time. Most efforts on tuning/modulation thus far report static changes based on irreversible techniques not suited for high-speed operation. In this study, we demonstrate in-situ dynamical tuning of the emission wavelength of a metallo-dielectric nanolaser at room temperature by applying an external DC electric field. Using an AC electric field, we show that it is also possible to modulate the output intensity of the nanolaser at high speeds. The nanolaser’s emission wavelength in the telecom band can be altered by as much as 8.35 nm with a tuning sensitivity of ∼1.01 nm/V. Additionally, the output intensity can be attenuated by up to 89%, a contrast sufficient for digital data communication purposes. Finally, we achieve an intensity modulation speed up to 400 MHz, limited only by the photodetector bandwidth used in this study, which underlines the capability of high-speed operation via this method. This is the first demonstration of a telecom band nanolaser source with dynamic spectral tuning and intensity modulation based on an external E-field to the best of our knowledge.

Deka, Suruj S. (ORCID:0000000297812317)↗

Intense quasi-monochromatic resonant harmonic generation in the multiphoton ionization regime

Resonant high-order harmonics, which result in quasimonochromatic extreme ultraviolet light with coherent intensity enhancement involving autoionizing resonances, have been demonstrated from laser-ablated plumes in the tunnel-ionization regime. Here, we demonstrate resonant harmonics in the previously unexplored multiphoton-ionization regime. We demonstrate an intense resonant harmonic from gallium with an intensity enhancement ratio of 714 relative to the neighboring harmonics, achieved without the need for extreme ultraviolet filtering methods, thus preventing a typical photon flux loss of more than 70%. Three-dimensional time-dependent Schrödinger equation calculations reveal that this increase in the enhancement ratio is due to the lowelectron wave packet spreading in the multiphoton-ionization regime. These results reveal a method for increasing the intensity and monochromaticity of intense multimicrojoule femtosecond extreme ultraviolet light and will also facilitate understanding of the involvement of autoionizing resonances in generating resonant harmonics in the multiphoton-ionization regime.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future North Atlantic tropical cyclone intensities in thermodynamically modified historical environments

Tropical cyclones (TCs) have ranked as the deadliest and most financially crippling natural disasters in the United States. It is imperative to assess potential shifts in TC intensity within the paradigm of an evolving climate. In this study we apply a fixed-constraint storyline approach that holds storm tracks and initial conditions constant to probe future TC intensity in the North Atlantic Basin. First, we simulate 618 historical TC events using the Risk Analysis Framework for Tropical Cyclones (RAFT)'s deep-learning intensity model. Next, we apply warming signals derived from eight CMIP6 climate scenarios and rerun each event to explore how intensities respond across scenarios. Finally, we develop an interactive dashboard that allows users to explore individual storm simulations and the scenario-modified environmental drivers. Together, this dataset and tool provide a clear, illustrative way to investigate how TC intensity responds to changes in air-sea state.

Climate Change↗

Application of helium line intensity ratio spectroscopy to xenon plasma in E × B Penning discharge

Here, we propose the application of helium line intensity ratio spectroscopy in a low-pressure (0.3 mTorr) xenon E × B discharge with an electron temperature of ~2 eV and a density of 10 10 –10 11 cm –3 . We successfully identified the helium atom line emissions at 388.9, 447.1, 501.6, 504.8, and 706.5 nm with helium pressures of up to ~20 mTorr. The measured electron temperature, density, and I–V characteristics of the discharge remained almost constant in all helium pressures in the present experiment, indicating the suitability of the helium gas as a diagnostic gas. The results of helium line intensity ratio spectroscopy using the line emissions at 388.9, 447.1, and 504.8 nm showed fair agreement with the Langmuir probe measurement. Considering the trade-off relationship between the disturbance introduced by the helium gas and the signal-to-noise ratio, we conclude that a helium pressure of approximately 4 mTorr (approximately 13 times the partial pressure of xenon) represents the optimal pressure range for the application of the helium line emission intensity ratio method to this xenon plasma. It is found that the use of the line emissions at 501.6 and 706.5 nm result in a significant disturbance in the helium line intensity ratio method due to the radiation trapping effect.

helium line intensity ratio spectroscopy↗

Absolute intensity calibration for carbon-edge soft X-ray scattering

Resonant soft X-ray scattering (RSOXS) has become a premier probe to study complex three-dimensional nanostructures in soft matter through combining the robust structural characterization of small-angle scattering with the chemical sensitivity of spectroscopy. This technique borrows many of its analysis methods from alternative small-angle scattering measurements that utilize contrast variation, but thus far RSOXS has been unable to reliably achieve an absolute scattering intensity required for quantitative analysis of domain compositions, volume fraction, or interfacial structure. Here, a novel technique to calibrate RSOXS to an absolute intensity at the carbon absorption edge is introduced. It is shown that the X-ray fluorescence from a thin polymer film can be utilized as an angle-independent scattering standard. Verification of absolute intensity is then accomplished through measuring the Flory–Huggins interaction parameter in a phase-mixed polymer melt. As a result, the necessary steps for users to reproduce this intensity calibration in their own experiments to improve the scientific output from RSOXS measurements are discussed.

47 OTHER INSTRUMENTATION↗

Elucidating regulatory processes of intense physical activity by multi-omics analysis

Abstract Background Physiological and biochemical processes across tissues of the body are regulated in response to the high demands of intense physical activity in several occupations, such as firefighting, law enforcement, military, and sports. A better understanding of such processes can ultimately help improve human performance and prevent illnesses in the work environment. Methods To study regulatory processes in intense physical activity simulating real-life conditions, we performed a multi-omics analysis of three biofluids (blood plasma, urine, and saliva) collected from 11 wildland firefighters before and after a 45 min, intense exercise regimen. Omics profiles post- versus pre-exercise were compared by Student’s t -test followed by pathway analysis and comparison between the different omics modalities. Results Our multi-omics analysis identified and quantified 3835 proteins, 730 lipids and 182 metabolites combining the 3 different types of samples. The blood plasma analysis revealed signatures of tissue damage and acute repair response accompanied by enhanced carbon metabolism to meet energy demands. The urine analysis showed a strong, concomitant regulation of 6 out of 8 identified proteins from the renin-angiotensin system supporting increased excretion of catabolites, reabsorption of nutrients and maintenance of fluid balance. In saliva, we observed a decrease in 3 pro-inflammatory cytokines and an increase in 8 antimicrobial peptides. A systematic literature review identified 6 papers that support an altered susceptibility to respiratory infection. Conclusion This study shows simultaneous regulatory signatures in biofluids indicative of homeostatic maintenance during intense physical activity with possible effects on increased infection susceptibility, suggesting that caution against respiratory diseases could benefit workers on highly physical demanding jobs.

59 BASIC BIOLOGICAL SCIENCES↗

2020 Review Panel Workshop on Energy Intensity Indicators: Summary Findings and Meeting Notes

On January 28-29, 2020, the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), in coordination with Pacific Northwest National Laboratory (PNNL), sponsored an expert workshop focused on energy intensity indicators. The intent of the workshop was to support a comprehensive review of the EERE Energy Intensity Indicators (EII), a national system of indicators used to track changes in the energy intensity of economic sectors. One goal of the workshop was to gather input from a panel of experts who have experience and knowledge related to the EII methodological approach and key data sources used to calculate indicators for each of the end-use sectors of the economy—transportation, residential, commercial, industrial, and electricity. The current EERE EII methodology is documented in a 2017 PNNL report, A Comprehensive System of Energy Intensity Indicators for the U.S.: Methods, Data and Key Trends, which is available online. The workshop also included a presentation by Dr. Beng Ang, who discussed the Log Mean Divisia index (LMDI) approach to decomposition analysis, which was followed by a discussion concerning the methodological approaches that could be applied to future EII efforts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review of the November 11, 1905 Earthquake: Seismic Intensity Data, Magnitude, and Location Report

The macroseismic location and magnitude of the Shoshone 1905 earthquake has been based on the application of objective and quantitative approaches that produce estimates of earthquake source location and magnitude, and associated uncertainties. The performance of all three approaches applied depends critically on the characteristics of the seismic intensity field. Regional intensity attenuation relations were derived based on a calibration set of earthquakes and then, the procedure was validated using three independent very recent events. The macroseismic epicenter location was determined by either a grid search procedure, the spatial distribution of the sites experiencing the largest intensities, or a combination of both. The macroseismic magnitude estimates are based on the derived regional intensity attenuation relations. There is consistency in the location and magnitude of the November 1905 earthquake as obtained by the three methods. The overlapping region of the 68% bootstrap resampling solutions suggests a reliable epicenter location within 41.550N ? 42.060N and 113.478W ? 112.320W. This region encloses the original Oaks (1992) epicenter location. Macroseismic magnitude estimates range between 5.87 and 6.05.

58 GEOSCIENCES↗

Changes in Climate and Its Effect on Timing of Snowmelt and Intensity-Duration-Frequency Curves

Snow is a critical water resource for much of the U.S. and failure to account for changes in climate could deleteriously impact military assets. In this study, we produced historical and future snow trends through modeling at three military sites (in Washington, Colorado, and North Dakota) and the Western U.S. For selected rivers, we performed seasonal trend analysis of discharge extremes. We calculated flood frequency curves and estimated the probability of occurrence of future annual maximum daily rainfall depths. Additionally, we generated intensity-duration-frequency curves (IDF) to find rainfall intensities at several return levels. Generally, our results showed a decreasing trend in historical and future snow duration, rain-on-snow events, and snowmelt runoff. This decreasing trend in snowpack could reduce water resources. A statistically significant increase in maximum streamflow for most rivers at the Washington and North Dakota sites occurred for several months of the year. In Colorado, only a few months indicated such an increase. Future IDF curves for Colorado and North Dakota indicated a slight increase in rainfall intensity whereas the Washington site had about a twofold increase. This increase in rainfall intensity could result in major flood events, demonstrating the importance of accounting for climate changes in infrastructure planning.

58 GEOSCIENCES↗

Water use in a young Pinus taeda bioenergy plantation: Effect of intensive management on stand evapotranspiration

Abstract The increasing demand for plant‐derived bioenergy is projected to expand tree plantations with intensive silviculture and improved tree genetics. These silvicultural practices result in faster stand development and canopy closure, which may also influence the systems' water dynamics. Here, we studied the evapotranspiration (ET) of a young (5 years old) intensively managed loblolly pine ( Pinus taeda ) stand and investigated the components of ET to determine its contribution to overall water use. We also compared ET with plantations that received less intensive management to determine whether our stand used more water. We used the eddy covariance method to estimate ecosystem‐level total ET (ET EC ), while plot‐level estimates of ET (ET P ) were obtained via soil lysimeters, sap flow sensors, and throughfall collectors, enabling measurement of the components of ET. Soil evaporation (Es) was the largest component of ET P (36%) over the course of the study, while transpiration and canopy interception accounted for 27% and 22%, respectively. Es decreased with stand development, while transpiration and canopy interception increased. Leaf area index (LAI) and precipitation were the most significant factors controlling ET and its components. Compared to previous studies in different sites that have similar age but lower LAI, our stand had higher water use. This high water use in the early stages of stand development was primarily due to high Es before the canopy was fully developed. While there are potential sources of uncertainty when comparing ET EC and the component fluxes in ET P , results from the two methods were not significantly different. This study had the advantage of using multiple methods to understand and verify the component processes that contribute to ET. Therefore, we recommend that multiple measurement techniques be used in the long‐term observation of ET, and in particular for the evaluation of the impact that intensively managed forests have on water resources in the southeastern United States.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of nature and intensity of fire concrete spalling by frequency analysis of sound records

Highlights: • Original sound-based NDT method to assess the spalling form and intensity within the time of the test is proposed. • Frequency analysis of recorded sound provides a quantitative and qualitative assessment of concrete propensity to spalling. • Nature of fire concrete spalling can be categorized by a well-defined frequency value. • Waveform and spectrogram analysis delivers information on the exact number of spalling events within the performed test. The paper presents a new method for identifying the form and intensity of spalling using an analysis of the acoustic signal emitted by concrete. To assess the intensity and monitor the course of concrete spalling during fire exposure, the analysis of the recorded sound from the furnace chamber is used. The spalling intensity was determined based on signal amplitude analysis. Investigation of sound records showed that the character of spalling can be categorized by a well-defined frequency value. Based on the analysis of the Fast Fourier Transform (FFT) spectrum, the authors have distinguished the following phenomena that are the source of the signal by assigning the corresponding frequency of the sound wave vibration: explosive spalling, aggregate spalling and destructive spalling.

36 MATERIALS SCIENCE↗

Water intensity of photovoltaic module manufacturing at the terawatt scale

As the U.S. ramps photovoltaic (PV) manufacturing to the terawatt scale and emphasizes re-shoring manufacturing, potential regional impacts on the U.S. water supply should be considered, particularly since many PV companies rely almost exclusively on public water supplies for manufacturing. This work surveys the academic literature and PV manufacturer reports to estimate the water intensity of monocrystalline silicon, multicrystalline silicon, and cadmium telluride modules manufactured at the terawatt scale, determining that on average, cadmium telluride manufacturing is less water intensive on a per megawatt scale – this is anticipated to be true for all thin film PV manufacturing. While much lower than the water intensity of thermoelectric (e.g., coal) energy generation, significant issues and gaps with PV manufacturing data quality in academic studies are identified which cause estimates to vary by over 1000x (0.04 – 49 trillion liters/terawatt). Data issues are discussed and the need for accurate accounting of water resources (e.g., via continuous, updated information during PV manufacturing) is highlighted. The opportunity to reconfigure decommissioned thermoelectric sites to PV manufacturing is also explored. Finally, factors that influence PV manufacturing water intensity, from individual manufacturing steps to trends across the PV industry, are examined and water conservation opportunities are presented.

14 SOLAR ENERGY↗

New approach to precisely measure γ-ray intensities for long-lived fission products, with results for the decay of 95 Zr

For many fission products, the rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields, provided sufficiently accurate information on the γ-ray intensity is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure absolute γ-ray intensities in the β decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β-decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the absolute γ-ray intensities of the strongest transitions following the β decay of 95 Zr and its decay-daughter 95 Nb, and determined them to fractional precisions of better than 1–2%. In addition, with a larger sample of activity produced through neutron irradiation of an isotopically-enriched Zr foil, we performed a high-precision measurement of the relative γ-ray intensities following the decay of 95 Zr with just the HPGe detector. Here, the sample-production method at CARIBU and the coincidence detection approach demonstrated here can be applied to study fission products with half-lives longer than a day, which includes isotopes important not only for nuclear-energy and national-security applications, but also for medical-isotope research and environmental monitoring.

4π↗

Intensity measure adequacy assessment for nonlinear site response using Information Theory

Nonlinear site response modeling is a crucial aspect of Probabilistic Seismic Hazard Analysis. Site amplification models routinely rely on a rock intensity measure to characterize the strength of the bedrock motion. However, the adequacy of such intensity measures towards predicting amplifications across the oscillator period range has not been investigated in the literature. This paper analyzes the adequacy of rock intensity measures using state of the art criterion established in Performance-Based Earthquake Engineering and techniques from Information Theory. The efficiency and the sufficiency of several rock intensity measure are assessed. It was found that spectral accelerations at low periods usually are adequate for predicting amplifications across the period range. This supports the current practice of using Peak Ground Acceleration in Ground Motion Models. However, for extremely soft sites, which demonstrate nonlinear effects well into the period range, it is better practice to ensure that amplification and spectral acceleration share the same oscillator period. Lastly, for predicting the peak shear strain (an important parameter that controls nonlinearity of site response), Peak Ground Velocity is generally adequate, and this conclusion is in line with the definition of proxy shear strain.

42 ENGINEERING↗