Search NASA⌕ Search

SEARCH · Search NASA

Results for “invasion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fluid Vessel Quantity using Non-Invasive PZT Technology Flight Volume Measurements Under Zero G Analysis

The purpose of the project is to perform analysis of data using the Systems Engineering Educational Discovery (SEED) program data from 2011 and 2012 Fluid Vessel Quantity using Non-Invasive PZT Technology flight volume measurements under Zero G conditions (parabolic Plane flight data). Also experimental planning and lab work for future sub-orbital experiments to use the NASA PZT technology for fluid volume measurement. Along with conducting data analysis of flight data, I also did a variety of other tasks. I provided the lab with detailed technical drawings, experimented with 3d printers, made changes to the liquid nitrogen skid schematics, and learned how to weld. I also programmed microcontrollers to interact with various sensors and helped with other things going on around the lab.

Garofalo, Anthony A.↗

Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector Using Non-invasive Laser, Optical and X-ray Techniques

The spray characteristics of a liquid-liquid double swirl coaxial injector were studied using non-invasive optical, laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler interferometry was used to characterize droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, X-ray radiography allowed for investigation of sheet thickness and breakup length to be quantified for different recess exit diameters and inlet pressures. Finally, computed tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

Radke, C. R.↗

Luminescent Tension-Indicating Orthopedic Strain Gauges for Non-Invasive Measurements Through Tissue

Strain gauges that can provide information with regard to the state of implantable devices are described. The strain gauges can exhibit luminescence that is detectable through living tissue, and the detectable luminescent emission can vary according to the strain applied to the gauge. A change in residual strain of the device can signify a loss of mechanical integrity and/or loosening of the implant, and this can be non-invasively detected either by simple visual detection of the luminescent emission or through examination of the emission with a detector such as a spectrometer or a camera.

Anker, Jeffrey↗

Method for Non-Invasive Determination of Chemical Properties of Aqueous Solutions

A method for non-invasively determining a chemical property of an aqueous solution is provided. The method provides the steps of providing a colored solute having a light absorbance spectrum and transmitting light through the colored solute at two different wavelengths. The method further provides the steps of measuring light absorbance of the colored solute at the two different transmitted light wavelengths, and comparing the light absorbance of the colored solute at the two different wavelengths to determine a chemical property of an aqueous solution.

Todd, Paul W.↗

Non-Invasive Tension Measurement Devices for Parachute Cordage

The need for lightweight and non-intrusive tension measurements has arisen alongside the development of high-fidelity computer models of textile and fluid dynamics. In order to validate these computer models, data must be gathered in the operational environment without altering the design, construction, or performance of the test article. Current measurement device designs rely on severing a cord and breaking the load path to introduce a load cell. These load cells are very reliable, but introduce an area of high stiffness in the load path, directly affecting the structural response, adding excessive weight, and possibly altering the dynamics of the parachute during a test. To capture the required data for analysis validation without affecting the response of the system, non-invasive measurement devices have been developed and tested by NASA. These tension measurement devices offer minimal impact to the mass, form, fit, and function of the test article, while providing reliable, axial tension measurements for parachute cordage.

Litteken, Douglas A.↗

Modal Propellant Gauging: High-resolution and non-invasive gauging of both settled and unsettled liquids in reduced gravity.

The modal response of a liquid-filled tank to external acoustic excitation can be used to infer with high resolutionthe mass of contained liquid, the mass flow rate of liquids into and out of the tank, and changes in tank pressure.Both contained liquid mass and internal ullage pressure affect the modal response of the tank walls through fluidmass-loading of the tank walls and pressure-induced wall stiffening, respectively. Modal Propellant Gauging refersto the technology that exploits these shifts in modal frequencies to infer the mass of propellant in a tank. MPG is anon-invasive gauging technology that has demonstrated gauging resolutions of 1% for settled propellants and 2-3%for unsettled, sloshing propellants. Extensive parabolic flight testing of the MPG system on model tanks has beenconducted to validate the technology in reduced gravity. MPG testing on a qualification tank for the Orion Program'sEuropean Service Module has also been conducted and is reported here. Finite element modeling of the OrionESM "upper" tank is discussed and compared with measurement data. Three computational approaches to massdetermination, Peak Tracking, Point Sensor, and Spectral Density methods, are described here. Use cases are definedand analyzed in the context of the Orion ESM Qualification tank data, and an implementation scheme for continuousmass gauging on the Orion ESM is discussed.Keywords: Propellant Mass Gauging, Modal Analysis, Orion ESM

Propellant Mass Gauging↗

Powder River Basin Water Resources: Mapping Russian Olive in the Powder River Basin to Inform Invasive Species Management

Since its introduction in the late 1800s, Elaeagnus augustifolia (Russian olive) has become a widespread invasive shrub that poses a threat to native riparian species in the United States by competing with native riparian plants for space and resources. To date, limited information on the distribution of Russian olive in the Powder River Basin of Montana and Wyoming have hampered management efforts and decision making. Here, we detect and model the distribution of Russian Olive using field surveys, ocular sampling, and variables from Landsat 8 Operational Land Imager (OLI), Sentinel-2 MultiSpectral Instrument (MSI), and Shuttle Radar Topography Mission (SRTM) using the Random Forest algorithm. We derived topographic, spectral, and hydrological variables from Landsat 8 OLI, Sentinel-2 MSI, and SRTM to utilize as model inputs. The team was able to successfully create a spectral Russian olive detection map for the Powder River Basin (RMSE =15.44%, R2 = 0.6482). The team also examined change in stream channel geomorphology from 1984-2020 in a time-series analysis using Landsat visible imagery and the RivMap MATLAB package and found little change. Our results will help our partners at the Powder River County Weed Board, Gay Ranch, United States Geological Survey, and University of Northern Colorado to locate and prioritize areas for riparian habitat restoration and to understand the region’s hydrology and geomorphology.

Catherine Buczek↗

Evaluating the success of treatments that slow spread of an invasive insect pest

BACKGROUND Treatments for the suppression and eradication of insect populations undergo substantial testing to ascertain their efficacy and safety, but the generally limited spatial and temporal scope of such studies limit knowledge of how contextual factors encountered in operational contexts shape the relative success of pest management treatments. These contextual factors potentially include ecological characteristics of the treated area, or the timing of treatments relative to pest phenology and weather events. We used an extensive database on over 1000 treatments of nascent populations of Lymantria dispar (L.) (gypsy moth) to examine how place-based and time-varying conditions shape the success of management treatments. RESULTS We found treatment success to vary across states and years, and to be highest in small treatment blocks that are isolated from other populations. In addition, treatment success tended to be lower in treatment blocks with open forest canopies, possibly owing to challenges of effectively distributing treatments in these areas. CONCLUSIONS Our findings emphasize the importance of monitoring for early detection of nascent gypsy moth colonies in order to successfully slow the spread of the invasion. Additionally, operations research should address best practices for effectively treating with patchy and open forest canopies. © 2021 Society of Chemical Industry.

Jonathan A Walter↗

Non-Invasive Ventilation Evaluation for Exploration Missions

This session will review the evidence supporting the use of non-invasive ventilation (NIV) for acute respiratory failure and will evaluate the validity and viability of using various modalities of NIV within the mass and volume constraints of exploration missions.

Aaliya Burza↗

Electronic Nose Development and Preliminary Human Breath Testing for Rapid, Non-Invasive COVID-19 Detection

We adapted an existing, spaceflight-proven, robust “electronic nose” (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using “leave-one-out” training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.

COVID-19↗

Remote Sensing Monitoring Methods for Detecting Invasive Weed Coverage in Delta Waterways and Bay Marshlands

This presentation is part of the Independent Science Board of the State of California Delta Stewardship Council brown bag seminar series on the "How the Delta is Monitored", followed with a panel discussion. Various remote sensing approaches for aquatic vegetation will be reviewed. Key research and application issues with remote sensing monitoring in the Delta will be addressed.

Invasive↗

A new approach to non-invasive oxygenated mixed venous PCO(sub)2

A clinically practical technique was developed to calculate mixed venous CO2 partial pressure for the calculation of cardiac output by the Fick technique. The Fick principle states that the cardiac output is equal to the CO2 production divided by the arterio-venous CO2 content difference of the pulmonary vessels. A review of the principles involved in the various techniques used to estimate venous CO2 partial pressure is presented.

Fisher, Joseph A.↗

Biological invasion by Myrica faya alters ecosystem development in Hawaii

The exotic nitrogen-fixing tree Myrica faya invades young volcanic sites where the growth of native plants is limited by a lack of nitrogen. Myrica quadruples the amount of nitrogen entering certain sites and increases the overall biological availability of nitrogen, thereby altering the nature of ecosystem development after volcanic eruptions.

Vitousek, Peter M.↗

A non-invasive measure of minerals and electrolytes in tissue

A system for collecting epithelial cells from the oral mucosa for the determination of ion concentration is discussed with application to the study of man's adaptation to microgravity. A number of characteristics of these cells influenced the choice for clinical testing. They are non-cornified epithelial cells located on the inferior aspect of the tongue; therefore, they are well protected from trauma. They have the capability of reflecting relatively recent physiologic changes since they are renewed every three days and have aerobic metabolism. Most importantly, they are easily accessible and can be removed by a wooden applicator stick with minimum discomfort. Smears of cells removed in this manner show predominantly individual cells rather than sheets of contiuous cells. This facilitates the visual isolation of single cells with the electron microscope for analysis. NASA's principle effort in the development of a test to measure the ion concentration in sublingual cells has been research by the biomedical program carried out by scientists with expertise in skeletal metabolism. These efforts were directed toward determining the biological meaning and deviations in interacellular ions in nonhuman primates and in male volunteers for experiments in a model for weightlessness. A brief one page summary of the experiments and results are presented.

Arnaud, Sara B.↗