A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

Transmission Data-Driven User-Defined Model for Inverter-based and Conventional Power Plants

Recent events in Odessa [1], [2] have shed light on the complexities of integrating large Inverter-Based Resource (IBR) plants with the transmission system, prompting NERC to stress continuous performance monitoring by transmission operators. Challenges such as plant control updates, IBR model revisions, Phase-locked loop loss of synchronism, and protection events have been identified, underscoring the need for enhanced monitoring protocols by regulatory bodies. The recent FERC 901 order underscores the importance of accurate data exchange regarding IBRs for reliability studies. However, limited access to IBR plant-related data hampers effective decision-making for transmission operators (TOP). This paper proposes a method for constructing data-driven User-Defined dynamic Models (UDM) for power plants for validating multiple-event data using field measurements from interconnection bus locations. The problem is formulated as a power plant model identification problem and a multi-task learning approach under partial input observability assumptions is proposed in this work. This approach aims to predict aggregated responses of conventional and IBR power plants during various dynamic physical events which is useful for planning studies under diverse disturbance conditions. Ultimately, this methodology emphasizes the importance of plant visibility to operators in addressing power system challenges, facilitating improved planning and operational studies.

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

UNIFI's Grid-Forming (GFM) Inverter Reference Design: A Tutorial on Modeling, Control, and Experimental Implementation of GFM Inverters

The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models [Slides]

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

14 SOLAR ENERGY↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

A Risk Assessment Framework for Cyber-Physical Security in Distribution Grids with Grid-Edge DERs

Integration of inverter-based distributed energy resources (DERs) is reshaping the landscape of distribution grids to fulfill the socioeconomic, environmental, and sustainability goals. Addressing the technological challenges of DER grid integration requires an adaptive communication layer for efficient DER management and control. This transition has given rise to a cyberphysical system (CPS) architecture within the distribution system, causing new vulnerabilities for cyberphysical attacks. To better address potential threats, this paper presents a comprehensive risk assessment framework for cyberphysical security in distribution grids with grid-edge DERs. The framework incorporates a detailed CPS model accounting for dynamic DER characteristics within the distribution grid. It identifies vulnerabilities in DER communication systems, models attack scenarios, and addresses communication latency crucial for inverter control timescales. Subsequently, the quantification of attack impacts employs an attack probability model including both the vulnerability and criticality of cyber components. The proposed risk assessment framework was validated through testing on the modified IEEE 13-node and 123-node test feeders.

cyberattack↗

A Unified Off-Board Charger for Three-Phase Inductive and Single-Phase Conductive EV Charging

This paper presents a unified off-board charger integrating a three-phase inductive power transfer (IPT) system and a single-phase conductive (plug-in) charger for electric vehicles (EVs). The proposed charger shares a high-frequency inverter and an integrated magnetic structure that enables three operating modes: conductive charging, inductive charging, and simultaneous charging. The transmitter coils for the three-phase IPT and the high-frequency transformer windings for the conductive charger are arranged on a common ferrite pad while maintaining magnetic decoupling between the two power transfer paths. The proposed unified architecture effectively increases charger utilization and power density without a proportional increase in cost, weight, or volume. Finite-element analysis using Ansys Maxwell confirms negligible coupling between the inductive and conductive coils, and the extracted parameters are employed in PLECS simulations to verify the independent operation of each charging mode.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

A State-Space Model of an Inverter-Based Microgrid for Multivariable Feedback Control Analysis and Design

In this work, a synchronous model for grid-connected and islanded microgrids is presented. The grid-connected model is based on the premise that the reference frame is synchronized with the AC bus. The quadrature component of the AC bus voltage can be cancelled, which allows to express output power as a linear equation for nominal values in the AC bus amplitude voltage. The model for the islanded microgrid is developed by integrating all the inverter dynamics using a state-space model for the load currents. This model is presented in a comprehensive way such that it could be scalable to any number of inverter-based generators using inductor–capacitor–inductor (LCL) output filters. The use of these models allows designers to assess microgrid stability and robustness using modern control methods such as eigenvalue analysis and singular value diagrams. Both models were tested and validated in an experimental setup to demonstrate their accuracy in describing microgrid dynamics. In addition, three scenarios are presented: non-controlled model, Linear-Quadratic Integrator (LQI) power control, and Power-Voltage (PQ/Vdq) droop–boost controller. Experimental results demonstrate the effectiveness of the control strategies and the accuracy of the models to describe microgrid dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Scalable Emulation of Hydropower Using Real-Time Hardware-in-the-Loop

This presentation covers Motivation: (1) With the increased grid integration of inverter-based resources, hydropower plays a crucial role in maintaining the bulk power system reliability and resilience; and (2) A more dynamic response and new control designs are required to meet the grid requirements. To evaluate any modification, control-prototyping, performance validation and de-risking grid integration of hydropower, a high-fidelity environment is required. Also covers Objectives: (1) To develop data-driven emulation of hydropower using hardware-in-the-loop for different size, types of hydro plants; and (2) To characterize hardware and obtain accurate dynamic response for shaft speed, torque, and power. Provide a mechanical power interface with emulated dynamics of a hydro-turbine shaft that can be coupled to electrical generators for mechanical and electrical PHIL.

electrical↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Distribution Function Instead of Steady-State Assumption in Time-Series Simulation

The quasi-steady-state assumption in time-series simulation is inadequate to model phenomena of interest to energy system integration such as inverter clipping, sell-back of excess electricity to a utility and utility hosting capacity, and battery throughput. Researchers are working on stochastic modeling, higher-resolution time series data, and machine learning approaches to address this need. This poster describes a distribution function that allows a maximum value, minimum value, and shape to the curve that can vary within each time-step based only on data inputs at the resolution of that time step (eg. Hourly). The distribution function is not used to synthesize high-resolution data, rather scalar integrals are used to calculate the quantities of interest within each time step. The form of the distribution function shows significant reduction in error when compared to 1 minute data and commercial software employing the distribution function (HOMER Pro version 14.3 and higher) shows a much improved estimate of inverter clipping in an example.

battery↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Tutorial - Electric Motor and Integrated Traction Drive Thermal Management

The share of vehicles with fully electric propulsion systems is constantly increasing, and so is their traction drive power. The continuous push to increase power of electric vehicle (EV) traction drives necessitates their efficient cooling to prevent damage to temperature sensitive components of the drive system and achieving higher power outputs in a smaller footprint. With increasing power and power density of electric traction drives, their thermal management is becoming increasingly challenging. This tutorial will provide an overview of thermal management approaches for electric motors and power electronics in EV applications. It will review examples of current industry solutions for power-dense electric motor cooling, power electronics (inverter) cooling, their integration concepts and thermal management system solutions. We'll look at the advantages and challenges of power electronics integration into a single traction drive unit and respective thermal management system concepts. We'll talk about barriers to implementation of a unified thermal management system. The tutorial will also review key aspects of thermal management system design: modeling and simulation using FEA and CFD tools, experimental characterization, and general workflow for thermal management system evaluation.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Power Solitons in Inverter-based Electric Energy Systems: Observation, Analysis and Implications

The discovery of an unfamiliar class of nonlinear energy waves in electric energy systems with dominating coupled inverter-based energy resources has been reported in a recent research project. Whenever there are slight but persistent differences among the reference signals used by inverters in pulse-width modulation, i.e., a weak group modulation instability condition, the unfamiliar energy waves appear, which contain not only the familiar frequency components present in electric power systems but also self-organized components in the ultra-high frequency region of the energy spectrum. These components are found to be exploding solitary waves with concentrated energy masses, hence we call them power solitons. This paper explains the work of the discovery reported, and the implications of the presence of power solitons for grid integration of inverter-based resources and power system protection.

14 SOLAR ENERGY↗

Acceleration of Power System Dynamic Simulations Using a Deep Equilibrium Layer and Neural ODE Surrogate

The dominant paradigm for power system dynamic simulation is to build system-level simulations by combining physics-based models of individual components. The sheer size of the system along with the rapid integration of inverter-based resources exacerbates the computational burden of running time domain simulations. Here, in this paper, we propose a data-driven surrogate model based on implicit machine learningspecifically deep equilibrium layers and neural ordinary differential equationsto learn a reduced order model of a portion of the full underlying system. The data-driven surrogate achieves similar accuracy and reduction in simulation time compared to a physics-based surrogate, without the constraint of requiring detailed knowledge of the underlying dynamic models. This work also establishes key requirements needed to integrate the surrogate into existing simulation workflows; the proposed surrogate is initialized to a steady state operating point that matches the power flow solution by design.

Neural ordinary differential equations↗

Validation of Microgrid Algorithms using At-Scale Simulation and Emulation Real-Time (ASSERT) Framework

This paper presents a novel framework for validating microgrid algorithms using a At-Scale Simulation and Emulation Real-Time (ASSERT) setup. The proposed universal microgrid validation framework was developed at Advanced Research on Integrated Energy Systems (ARIES) platform at National Renewable Energy Laboratory in Golden, Colorado, USA. As the number of intercommunicating devices grow in power systems, along with more integration of inverter-based resources, developing and validating microgrid operation and control algorithms is becoming complex and time-consuming task. The ASSERT framework is designed to provide a comprehensive, accurate, and efficient solution for validating microgrid algorithms. It combines at-scale simulations and real-time emulation to create a virtual environment that closely mimics the behavior of a physical microgrids which are characteristic of future smart distribution systems, such as: (1) increasing variability in the physical size of new energy technologies; (2) requiring control large numbers of interconnected devices, and (3) integrating diverse technologies that have not previously worked together. The paper describes the technical details of the ASSERT framework, its validation process, and its benefits over traditional validation methods. The framework's ability to validate the performance of various algorithms is demonstrated through a case study, which shows that it can effectively identify the weaknesses of an algorithm and optimize its performance. Overall, the ASSERT framework is a promising tool that can significantly enhance the development and validation of microgrid algorithms, leading to more reliable and efficient microgrid operation.

at-scale↗