Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

From Electronic Structure to Ion Transport: Photoelectron Spectroscopy and Molecular Dynamics Simulations Reveal the Role of Anions in Lithium Battery Electrolytes

Electrolyte anions are pivotal for lithium battery performance, yet their fundamental electronic structural properties are not well understood. In this work, we employ a combination of negative-ion photoelectron spectroscopy (NIPES), ab initio calculations, and molecular dynamics (MD) simulations to investigate the electronic structures of three representative electrolyte anions. This multiscale approach enables us to elucidate how their intrinsic electronic properties govern anion–solvent interactions in gas-phase clusters, as well as lithium-ion (Li + ) solvation structures and ion transport behavior in the condensed phase. NIPES reveals that difluoro(oxalato)borate (DFOB – ), bis(fluorosulfonyl)imide (FSI – ), and bis(oxalato)borate (BOB – ) all exhibit high electron binding energies, with vertical/adiabatic detachment energies increasing from DFOB – (6.09/5.70 eV) to FSI – (6.80/6.10 eV) to BOB – (6.82/6.40 eV), correlating with enhanced oxidation stability. Ab initio calculations reveal that DFOB – /FSI – –solvent complexes bind Li + ∼ 10 kcal/mol stronger than BOB – series, aligning with the strength of a Li + –anion model. DFOB – exhibits pronounced charge localization on both oxygen and fluorine atoms, enabling their involvement in Li + coordination. In contrast, fluorine atoms in FSI – are largely electron-depleted and remain excluded from direct Li + binding. MD simulations further demonstrate that LiDFOB and LiFSI systems exhibit Li + diffusion coefficients three and five times higher than those of LiBOB across four common solvents. Notably, LiFSI salt in acetonitrile (AN) exhibits the fastest Li + diffusion among 12 electrolyte systems, highlighting the synergistic effect of FSI – and AN in promoting ion mobility. In conclusion, these findings provide a molecular-level understanding of the critical roles of anion and its microsolvation in optimizing Li + diffusion dynamics, once again emphasizing the positioning of FSI – and DFOB – as prime candidates for next-generation electrolytes.

25 ENERGY STORAGE↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of LEED, Auger emission spectroscopy and field ion microscopy in microstructural studies.

The studies reported were conducted to gain a fundamental understanding of adhesion and dynamic friction on an atomic or microscopic level. Fundamental aspects of low energy electron diffraction (LEED), Auger emission spectroscopy (AES), and field ion microscopy (FIM) are discussed. Typical results of studies conducted are considered, giving attention to LEED-AES experiments, pin and disk experiments, and field ion microscope investigations.

Ferrante, J.↗

Nuclear spectroscopy with heavy ion nucleon knockout and (p,2p) reactions

Knockout reactions with heavy ion targets in inverse kinematics, as well as “quasifree” (p,2p) and (p,pn) reactions are useful tools for nuclear spectroscopy. We report calculations on ab initio many-body wave functions based on the no-core shell model to study the nucleon removal reactions in light nuclei, including beryllium, carbon, and oxygen isotopic chains, and explore the importance of using an ab initio method. Our study helps to clarify how the extraction of spectroscopic factors from the experiments depend on the details of the many-body wave functions being probed. We show that recent advances with the ab initio method can provide more insights on the spectroscopy information extracted from experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tribochemical changes of alloy 800HT under sliding contact at elevated temperature in impure helium environment

This work investigates the chemical changes of the surface of Alloy 800HT during sliding contact under helium atmosphere in the presence of impurities at 750 °C, which is of interest for the nuclear industry. The alloy samples are exposed to helium (He) atmosphere at high temperature for long duration of 500 h to identify the chemical and topographical changes of the alloy surface. The oxidation rate constant is reported based on the weight change data. For the tribo-experimental samples, the surfaces inside and outside the wear track are studied thoroughly using techniques such as secondary electron microscopy, energy dispersive spectroscopy, x-ray diffraction, Raman spectroscopy and secondary ion mass spectroscopy. The formation and evolution of surface oxides are discussed in He atmosphere, compared with air. The presence of Fe-rich thin layer of oxide on top of a thicker Cr-rich oxide and a mixed spinel-based inner layer on the bulk is found. The persistent presence of thicker Fe3O4 in the wear track in high temperature air proved to be the reason of lower friction property. Pre-oxidation of the samples in air or He does not improve but worsen the tribological behavior in He atmosphere.

36 MATERIALS SCIENCE↗

Compositional analysis of silicon

The use of surface analysis methods in the detection and evaluation of elemental and impurity species in Si is presented. Examples are provided from polycrystalline Si and high-efficiency MINP cells. Auger electron spectroscopy and secondary ion mass spectrometry are used to complement microelectrical data obtained by electron-beam induced-current measurements. A new method is discussed which utilizes the volume indexing of digital secondary ion mass spectroscopy signals, providing compositional information and impurity maps on internal materials/device interfaces.

Kazmerski, L. L.↗

Characterization of carbon fibers and fiber-matrix adhesion in composites

The effect of fiber/matrix interactions on the mechanical properties of thermoplastic carbon fiber composites was determined. The experimental approach was a multi-faceted one involving the following areas: characterization of the surface of carbon fibers using X-ray photoelectron spectroscopy (XPS), secondary ion mass spectroscopy (SIMS) and scanning transmission electron microcopy (STEM); determination of the functional groups on carbon fiber surfaces using an elemental tagging scheme - derivatization; determination of the polar and dispersion contribution to the surface energy of carbon fibers by measuring wetting forces in a series of liquids having known polar and dispersion components; and study of the interaction of thermoplastic polymers with carbon surfaces by solution adsorption, STEM and fiber critical length.

Wightman, J. P.↗

Direct-current magnetron fabrication of indium tin oxide/InP solar cells

Efficient solar cells of indium tin oxide (ITO)/InP have been fabricated using dc magnetron deposition of the ITO into single-crystal InP substrates. Efficiencies of over 16.5 percent have been achieved, the highest ever recorded for devices of this construction. The results of studies of the annealing behavior of the cells and observations of interfacial changes using Raman spectroscopy and secondary ion mass spectroscopy, together with measurements of light and dark current/voltage and quantum efficiency characteristics, are used to model the behavior of the cells and explain their lack of sensitivity to fabrication conditions.

Coutts, T. J.↗

Direct Identification of Mixed-Metal Centers in Metal–Organic Frameworks: Cu 3 (BTC) 2 Transmetalated with Rh 2+ Ions

Raman spectroscopy was used to establish direct evidence of heterometallic metal centers in a metal–organic framework (MOF). The Cu 3 (BTC) 2 MOF HKUST-1 (BTC 3– = benzenetricarboxylate) was transmetalated by heating it in a solution of RhCl 3 to substitute Rh 2+ ions for Cu 2+ ions in the dinuclear paddlewheel nodes of the framework. In addition to the Cu–Cu and Rh–Rh stretching modes, Raman spectra of (Cu x Rh 1– x ) 3 (BTC) 2 show the Cu–Rh stretching mode, indicating that mixed-metal Cu–Rh nodes are formed after transmetalation. Density functional theory studies confirmed the assignment of a Raman peak at 285 cm –1 to the Cu–Rh stretching vibration. Electron paramagnetic resonance spectroscopy experiments further supported the conclusion that Rh 2+ ions are substituted into the paddlewheel nodes of Cu 3 (BTC) 2 to form an isostructural heterometallic MOF, and electron microscopy studies showed that Rh and Cu are homogeneously distributed in (Cu x Rh 1– x ) 3 (BTC) 2 on the nanoscale.

02 PETROLEUM↗

Electric Field Analysis in a Cold-Ion Source Using Stark Spectroscopy of Rydberg Atoms

Here, we analyze electric fields in ion sources generated by quasicontinuous photoionization of cold Rb atoms trapped in the focal spot of a near-concentric, in-vacuum cavity for 1064-nm laser light. Ion streams are extracted with an external electric field, F. Stark effects of Rb 57F and of nearby high-angular-momentum Rydberg levels, which exhibit large, linear Stark shifts, are employed to study the net electric-field probability distribution within the ion-source region over an extraction-field range of 0 < F < 0.35 V/cm. For F = 0, we also investigate ion-field-induced Stark spectra of the 60P 1/2 state, which exhibits a (lesser) quadratic electric-field response that affords a simplified electric-field analysis. Experimental Rydberg spectra are compared with theoretical Stark spectra, which are weighted with net electric-field distributions obtained from classical ion-trajectory simulations that include Coulomb interactions. Experiments and models are in good agreement. At small F and high ion-source rates, the field approximately follows a Holtsmark distribution, and the ion streams are degraded by the Coulomb microfields. With increasing F and at lower ion-source rates, the fields become narrowly distributed around F, resulting in directional ion streams that are less degraded by microfields. Our results are of interest for monitoring cold-ion sources for focused-ion-beam applications, where Coulomb interactions are of concern, and for studies of electric fields in cold plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Parametric dependence of ion temperature and electron density in the SUMMA hot-ion plasma using laser light scattering and emission spectroscopy

Hot-ion plasma experiments were conducted in the NASA Lewis SUMMA facility. A steady-state modified Penning discharge was formed by applying a radially inward dc electric field of several kilovolts near the magnetic mirror maxima. Results are reported for a hydrogen plasma covering a wide range in midplane magnetic flux densities from 0.5 to 3.37 T. Input power greater than 45 kW was obtained with water-cooled cathodes. Steady-state plasmas with ion kinetic temperatures from 18 to 830 eV were produced and measured spectroscopically. These ion temperatures were correlated with current, voltage, and magnetic flux density as the independent variables. Electron density measurements were made using an unusually sensitive Thomson scattering apparatus. The measured electron densities range from 2.1 x 10 to the 11th to 6.8 x 10 to the 12th per cu cm.

Snyder, A.↗