Search NASA⌕ Search

SEARCH · Search NASA

Results for “islanded mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

Demonstrating the Need for Adaptive Droop Control for Grid-Forming Inverters in Islanded and Grid-Connected Modes

This paper demonstrates the need of adaptive droop of grid-forming (GFM) inverters operating in different operation modes (grid-connected and islanded). A pure hardware microgrid comprising multiple grid-forming (GFM) inverters from different vendors, multiple grid-following inverters, and a diesel generator is used for the demonstration. The key findings are summarized as follows: Tighter droop slope should be used in the islanded mode, and looser droop slope should be used in the grid-connected mode to ensure stability. It is important to have adaptive droop control in GFM inverters to ensure stable and reliable microgrid operation.

14 SOLAR ENERGY↗

Fuel Cell Inverter Dataset

This data set contains the three phase AC voltage, three phase AC current, DC voltage and DC current. These data sets were captured during fuel cell inverter operation in grid-connected dispatch, islanded load changes, transition from grid-connected mode to islanded mode and vice-versa.

25 ENERGY STORAGE↗

Frank-van der Merwe growth in bilayer graphene

Bilayer graphene has attracted significant interest because of its unique properties, including fascinating electrical behavior when one layer is slightly rotated relative to the other. However, the quality of large-area bilayer graphene is often limited by the layer-plus-island growth mode in which islands of thicker graphene present as unavoidable impurities. Here, we report the observation of the layer-by-layer, Frank-van der Merwe (FM) growth mode in bilayer graphene where multilayer impurities are suppressed. Instead of the conventional surface adhesive energy, we found it possible to tune interface adhesive energy with an oxidative pretreatment. Finally, the FM-grown bilayer graphene is of AB stacking or with small twisting angle (θ = 0°–5°), which is more mechanically robust compared with monolayer graphene, facilitating a free-standing wet transfer technology.

36 MATERIALS SCIENCE↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid

Legacy energy management systems for distribution system or microgrids are typically driven by economics. During extreme events, resiliency can be defined as ability of the system to keep supplying critical loads. Resilient operation during extreme events (e.g. avalanche in Alaska) may require decision variables to be different and conflicting with economic operation. Operational objectives are driven by a complex consideration of the economic, reliable and resilient operation of the system: economic and reliable in normal operating state and resilient during extreme events. Challenge is to move between economic and resilient operation in optimal manner and setting up problem formulation and constraints specially with Distributed Energy Resources (DERs). In this paper, we focus on striking a balance between optimal economic and resilient operation using novel formulation and developed tool called Resiliency Enabled Energy System Operation Toolbox (RE-ESOT). Simulation results are provided for a real islanded grid in Alaska with battery energy systems.

50 EE - Wind and Water Power Program - Water (EE-4↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid: Preprint

Power System is a complex system, with an objective to provide power to the customers. The objective is driven by a complex consideration of the secure, economic and resilient operation of the system. With the growing occurrence of extreme events emphasis has been shifted towards making the grid more resilient. However, an economic operation is still a priority for the utilities as well as its customers. Many utilities especially small isolated micro-grids do not emphasize much on an economic and resilient operation, but more on reliability. In this research we focus on striking a balance between economic and resilientoperation, ensuring reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PPPL Report on Reduced Modeling of Fusion Alpha Transport in ARC Burning Plasmas

We are reporting on the modeling of fusion alpha particle transport in the planned ARC fusion device being designed by the CFS (Commonwealth Fusion Systems: https://cfs.energy). The ARC tokamak is designed to operate in a burning-plasma regime characterized by a substantial population of fusion-born alpha particles. Alfvén eigenmode (AE) stability is assessed both analytically and numerically, incorporating alpha-particle drive, ion Landau, and radiative damping from thermal species and collisional damping from trapped electrons. Regions of unstable and near-threshold AE activity are mapped across ARC’s operational parameter space. Linear stability analysis with NOVA indicates multiple, often marginally unstable AEs, extending to toroidal mode numbers up to n= 30. The present report focuses on the ARC flat-top operating point prior to the sawtooth event. Alpha-particle transport on timescales exceeding the neoclassical slowing-down time is assessed using the NUBEAM module [1][2] of the TRANSP code [3], employing transport coefficients derived from the RBQ quasilinear modeling (cf. Appendix B). These global simulations identify favorable and unfavorable operating regimes with respect to alpha confinement, pressure redistribution, and overall alpha-heating efficiency. We also evaluate additional transport mechanisms—including neoclassical tearing mode (TM)–induced stochasticity, sawtooth-driven redistribution, and toroidal-field ripple using the kick model (cf. Appendix C) which makes use of the guiding-center code ORBIT, see Section 5. The kick model is integrated into TRANSP to enable self-consistent predictions of alpha-driven current formation and sustainment within the ARC scenario. Sensitivity scans are performed over the mode frequency, rational-surface alignment, island width, mode amplitude, and proximity of the limiter to the plasma. Our study provides an initial, physics-based guidance for machine design, operational planning, and equilibrium control, ensuring adequate alpha confinement and robust self-heating performance in ARC. Our simulations mostly targeted worst case scenarios, e.g. for TMs and sawteeth. Overall, we expect benign effects for the ARC scenario investigated in this work on fusion alpha confinement and losses in the presence of AEs, tearing modes and sawteeth. This report addresses three thrusts identified at the outset. The first thrust focuses on analytic estimates of the parametric dependencies of EP relaxation based on local AE stability simulations (Section 3). The second thrust involves global evaluations of AE stability using the NOVA, RBQ, and NUBEAM codes (Section 4). Finally, we investigate alpha-particle transport driven by low-frequency instabilities associated with sawteeth and tearing modes (Section 5).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Grid-Renewable Strategies for Green Steel Production under Electricity Market Uncertainty

Volatility in grid spot prices is expected to rise with climate change-driven demand pressures and the intermittency of renewable generation. This volatility poses financial risks for green hydrogen-based steel production. The Direct Reduced Iron− Electric Arc Furnace (H 2 -DRI-EAF) is a promising pathway to decarbonize steel, which accounts for ∼8% of global GHG emissions. This study assesses how increased grid spot price volatility influences the optimal sizing and operation of H2-DRIEAF plants under three operational scenarios: grid-connected, fully behind-the-meter (islanded), and mixed-mode (semi-islanded). Our analysis identifies the semi-islanded configuration as the most cost-effective solution, achieving a Levelized Cost of Steel (LCOS) 10−35% lower than sourcing energy solely from the grid. Modeling also shows hydrogen storage or selective electricity purchases at high prices (>$1000/MWh) generally outperform battery storage, except under extreme volatility. Additionally, the study explores cost reduction strategies to strengthen the economic viability and sustainability of green steel production.

Batteries↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Universal Controller for Grid-Forming Inverters in Microgrid during Islanding for Low Transient Current

This paper presents a universal controller to reduce the transient current during islanding of microgrid. In the proposed universal controller, two sets of semi-parallel paths are formed, where one set produces voltage and phase-angle references for the grid-following (GFL) mode, and the other set produces the voltage and phase-angle references for the grid-forming (GFM) mode of operation for the inverters. Herein, the controller enables an inverter to universally operate in GFL and GFM mode, whereas, only one set of voltage and phase-angle reference is engaged for PWM signal generation. When the microgrid is disconnected from the grid, the universal controller switches the voltage and phase-angle references from GFL to GFM mode. The proposed controller ensures lower transient current by keeping the two sets of semi-parallel paths synchronized throughout the operation of the inverter and enabling seamless transition between the modes. The proposed controller is verified through hardware experiments under different scenarios in a laboratory scale microgrid for inverters transitioning from GFL to GFM mode after islanding.

Sadeque, Fahmid↗

Enhancement of ECCD by the current condensation effect for stabilizing large magnetic islands caused by neoclassical tearing modes in tokamak plasmas

The radio frequency current condensation effect reported in Reiman and Fisch (2018 Phys. Rev. Lett. 121 225001) is modeled in the nonlinear resistive magnetohydrodynamic code. A series of numerical investigations have been performed to investigate the enhancement of electron cyclotron current drive (ECCD) by the current condensation effect during the control of neoclassical tearing mode (NTM) in tokamak plasmas. In the numerical model, both the parallel transport and the perpendicular transport of electron temperature are considered. The EC driven current and driven perturbed electron temperature can nonlinearly evolve within the given magnetic configuration and eventually reach saturation states. The input power threshold of ECCD and the fold bifurcation phenomenon are numerically verified via nonlinear simulations. The numerical results show good agreements with the analytical results. Moreover, spatial distributions of EC current for the two solutions at different condensed level are displayed. The control effectiveness of ECCD for large NTM islands has been evaluated while considering the current condensation effect. While taking into account current condensation effect, for a sufficiently large input power, a larger island can be more effectively stabilized than a smaller one, which suggests a reassessment of the previous idea that the ECCD should always be turned on as early as possible. The potential physics mechanism behind the ECCD control have all been discussed in detail. Furthermore, the condensation effect is found to have favorable effects on the radial misalignment of ECCD. In the consideration of the situation for extremely localized control needs, a highly peaked heating profile is adopted to verify that the fold bifurcation phenomenon still exists and the current condensation effect can still take effect in this extreme condition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generalized kinetic equation for tokamak plasma equilibrium distribution function

A generalised kinetic equation for the equilibrium distribution function in a finite beta, arbitrary tokamak plasma is derived. The equation is correct to second order in ρ/L (ρ is the particle Larmor radius and L is the system size). Resolving finite Larmor radius length scales with no restriction on the ratio of poloidal to total equilibrium magnetic field, B $\vartheta$ /B, it generalises the drift kinetic theory of [Hazeltine Phys. Plasmas 15 (1973) 77] to the limit of B $\vartheta$ /B ~ 1 (e.g. to ensure validity for spherical tokamaks). Two cases are considered. The first provides the equilibrium distribution function, consistent with the generalised gyrokinetic formalism of [Dudkovskaia et al. Plasma Phys. Control. Fusion 65 (2023) 045010], derived specifically to capture neoclassical equilibrium currents in gyrokinetic stability analyses in strong gradient regions. The second assumes short length scales in the direction perpendicular to the magnetic field, which can occur as a result of small coherent magnetic structures in the plasma, such as neoclassical tearing mode magnetic islands close to threshold. This then extends the drift island equations of [Dudkovskaia et al. Nucl. Fusion 63 (2023) 016020] for the plasma response to magnetic islands to a spherical tokamak plasma configuration. In conclusion, resolving ρ ~ ρ $\vartheta$ (or B $\vartheta$ ~ B), where ρ $\vartheta$ is the particle poloidal Larmor radius, is also expected to influence calculations of the magnetic island propagation frequency and the associated contributions to the island onset conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Advanced Distributed Wind Turbine Controls Series: Part 4-Wind Energy in Microgrids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years, the technical capabilities and requirements for distributed wind turbines to provide ancillary services beyond maximum energy production has increased. Ancillary services, leveraged through advanced wind turbine controls, can support grid stability, reliability, and resilience. In the context of a microgrid, wind turbines can provide ancillary services that are useful in both islanded and grid-connected modes, as demonstrated in previous parts of this report series. This report focuses on how wind turbines with advanced controls and power electronics can support the stability of the microgrid during transitions from grid-connected to island mode, and back. This report documents simulation results from a model of the National Renewable Energy Laboratory (NREL) Flatirons Campus containing NREL's 600-kilowatt Controls Advanced Research Turbine. Using this turbine, we demonstrate through desktop simulation how a wind turbine can support the voltage and frequency of a microgrid during transitions - from making planned transitions seamless to keeping all loads online during some unplanned transitions to supporting black start in the event of an open transition (blackout).

17 WIND ENERGY↗