Search NASA⌕ Search

SEARCH · Search NASA

Results for “kinetic inductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ca2+ Effects on Fe(II) Interactions with Mn-Binding Sites in Mn-Depleted Oxygen-Evolving Complexes of Photosystem II and on Fe Replacement of Mn in Mn-Containing, Ca-Depleted Complexes

Fe(II) cations bind with high efficiency and specificity at the high-affinity (HA), Mn-binding site (termed the “blocking effect” since Fe blocks further electron donation to the site) of the oxygen-evolving complex (OEC) in Mn-depleted, photosystem II (PSII) membrane fragments (Semin et al. in Biochemistry 41:5854, 2002). Furthermore, Fe(II) cations can substitute for 1 or 2Mn cations (pH dependent) in Ca-depleted PSII membranes (Semin et al. in Journal of Bioenergetics and Biomembranes 48:227, 2016; Semin et al. in Journal of Photochemistry and Photobiology B 178:192, 2018). In the current study, we examined the effect of Ca2+ cations on the interaction of Fe(II) ions with Mn-depleted [PSII(-Mn)] and Ca-depleted [PSII(-Ca)] photosystem II membranes. We found that Ca2+ cations (about 50 mM) inhibit the light-dependent oxidation of Fe(II) (5 µM) by about 25% in PSII(-Mn) membranes, whereas inhibition of the blocking process is greater at about 40%. Blocking of the HA site by Fe cations also decreases the rate of charge recombination between QA- and YZ•+ from t1/2?=?30 ms to 46 ms. However, Ca2+ does not affect the rate during the blocking process. An Fe(II) cation (20 µM) replaces 1Mn cation in the Mn4CaO5 catalytic cluster of PSII(-Ca) membranes at pH 5.7 but 2 Mn cations at pH 6.5. In the presence of Ca2+ (10 mM) during the substitution process, Fe(II) is not able to extract Mn at pH 5.7 and extracts only 1Mn at pH 6.5 (instead of two without Ca2+). Measurements of fluorescence induction kinetics support these observations. Inhibition of Mn substitution with Fe(II) cations in the OEC only occurs with Ca2+ and Sr2+ cations, which are also able to restore oxygen evolution in PSII(-Ca) samples. Nonactive cations like La3+, Ni2+, Cd2+, and Mg2+ have no influence on the replacement of Mn with Fe. These results show that the location and/or ligand composition of one Mn cation in the Mn4CaO5 cluster is strongly affected by calcium depletion or rebinding and that bound calcium affects the redox potential of the extractable Mn4 cation in the OEC, making it resistant to reduction.

calcium↗

Current-Phase Relations of Superconducting PtSi Constriction Josephson Junctions

Here, we study the current-phase relations of superconductor–constriction–superconductor Josephson junctions made from platinum silicide thin films by fabricating dc-superconducting quantum interference devices incorporating pairs of junctions and measuring their magnetic-field-dependent electrical transport. By comparing the supercurrent interference patterns with numerical Ginzburg–Landau simulations, we extract the current-phase relations of individual junctions and quantify the degree of nonlinearity. These measurements show that while the constrictions themselves sustain substantial nonlinearity, the effect is moderated by the kinetic inductance of the device leads, which is an important consideration for practical superconducting circuit applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SLAC microresonator RF(SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Here, we describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

47 OTHER INSTRUMENTATION↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiatively cooled quantum microwave amplifiers

Superconducting microwave amplifiers are essential for sensitive signal readout in superconducting quantum processors. Typically based on Josephson junctions, these amplifiers require operation at milli-Kelvin temperatures to achieve quantum-limited performance. Here, we demonstrate a quantum microwave amplifier that employs radiative cooling to operate at elevated temperatures and maintain near quantum-limited added noise. This kinetic-inductance-based parametric amplifier, patterned from a single layer of relatively high-Tc NbN thin film, maintains a high gain and meanwhile enables low added noise of 1.3 quanta when operated at 1.5 K. Remarkably, this represents only a 0.2 quanta increase compared to the performance at a base temperature of 0.1 K. Based on our findings, we also discuss the practicality of such an operating scheme for various quantum applications. By uplifting the parametric amplifiers from the mixing chamber without compromising readout efficiency, this work represents an important step toward more scalable microwave quantum technologies.

Physics↗

Low two-level-system noise in hydrogenated amorphous silicon

At sub-Kelvin temperatures, two-level systems (TLSs) present in amorphous dielectrics source a permittivity noise, degrading the performance of a wide range of devices using superconductive resonators such as qubits or kinetic inductance detectors. We report here on measurements of TLS noise in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition in superconductive lumped element resonators using parallel-plate capacitors. In conclusion, the TLS noise results presented in this article for two recipes of a-Si:H improve on the best results achieved in the literature by a factor >5 for a-Si:H and other amorphous dielectrics and are comparable to those observed for resonators deposited on crystalline dielectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Waveform analysis of a large-area superconducting nanowire single photon detector

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum communications. However, the long meander-line length of such large-area SNSPDs results in a proportionately large kinetic inductance that affects the waveform generated by the device. Here, we explore changes in the rising edge of the readout pulse for a single-pixel large-area SNSPD as a function of the optical spot size on the detector and compare to the rising edge of the dark-count waveform. We observe a bimodal distribution of bright-count rise times and show that the probability of a slow rise time increases in the limit of large spot sizes, indicative of a position sensitive response. Additionally, in the limit of low bias currents, the dark-count readout pulse is most similar to the large spot-size bright-count readout pulse, which suggests that dark counts arise from locations spanning the device. Overall, these results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning microwave losses in superconducting resonators

Abstract The performance of superconducting resonators, particularly cavities for particle accelerators and micro cavities and thin film resonators for quantum computations and photon detectors, has been improved substantially by recent material treatments and technological advances. As a result, the niobium cavities have reached the quality factors Q ∼ 10 11 at 1–2 GHz and 1.5 K and the breakdown radio-frequency (rf) fields H close to the dc superheating field of the Meissner state. These advances raise the questions of whether the state-of-the-art cavities are close to the fundamental limits, what these limits actually are, and to what extent the Q and H limits can be pushed by the materials nano structuring and impurity management. These issues are also relevant for many applications using high-Q thin film resonators, including single-photon detectors and quantum circuits. This topical review outlines basic physical mechanisms of the rf nonlinear surface impedance controlled by quasiparticles, dielectric losses and trapped vortices, as well as the dynamic field limit of the Meissner state. Sections cover methods of engineering an optimum quasiparticle density of states and superfluid density to reduce rf losses and kinetic inductance by pairbreaking mechanisms related to magnetic impurities, rf currents, and proximity-coupled metallic layers at the surface. A section focuses on mechanisms of residual surface resistance, which dominates rf losses at ultra low temperatures. Microwave losses of trapped vortices and their reduction by optimizing the concentration of impurities and pinning potential are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Revealing the loss mechanisms of a 3D superconducting microwave cavity for use in a dark matter search

Superconducting microwave cavities have found applications in many areas including quantum computing, particle accelerators, and dark matter searches. Their extremely high quality factors translate to very narrow bandwidth, which makes them key components of sensitive detectors. In this study, we aim to understand the loss mechanisms of an aluminium cavity, with a fundamental mode frequency of about 2.5123 GHz, and how they change as the cavity material transitions from the superconducting to normal state. We found that at temperatures not much lower than the transition temperature $T_c$, losses are dominated by quasiparticle excitations and are well described by the Bardeen–Cooper–Schrieffer theory. The exponential decrease of the quasiparticle density below $T_c$ results in a 1000-fold increase of the quality factor, as well as a shift of the resonance frequency due to the change of the kinetic inductance of the superconductor. At very low temperatures, losses due to two-level systems begin to dominate giving a peak in the quality factor of about 2.76 x 10 7 at 130 mK. Understanding the loss mechanisms is invaluable, as the working temperature of the cavity may vary during operation regardless of its application.

Physics - Physics of elementary particles and fiel↗

Cryogenic growth of aluminum: Structural morphology, optical properties, superconductivity, and microwave dielectric loss

We explore the molecular beam epitaxy synthesis of superconducting aluminum thin films grown on c-plane sapphire substrates at cryogenic temperatures of 6 K and compare their behavior with films synthesized at room temperature. We demonstrate that cryogenic growth increases structural disorder, producing crystalline grains that modify the optical, electrical, and superconducting properties of aluminum. We observe that cryogenic deposition changes the color of aluminum from fully reflective to yellow and correlate the pseudodielectric function and reflectance with structural changes in the film. We find that smaller grain sizes enhance the superconductivity of aluminum, increasing its critical temperature and critical field. We then estimate the superconducting gap and coherence length of Cooper pairs in aluminum in the presence of disorder. In conclusion, we fabricate superconducting microwave resonators on these films and find that, independently of the growth temperature, the system is dominated by two-level system loss with similar quality factors in the high- and low-power regimes. We further measure a higher kinetic inductance in the cryogenically grown films.

36 MATERIALS SCIENCE↗

Quantum Versus Classical Switching Dynamics of Driven Dissipative Kerr Resonators

Here, we report a first-principles study of the driven dissipative dynamics for Kerr oscillators in the mesoscopic regime. This regime is characterized by large Kerr nonlinearity, realized here using the nonlinear kinetic inductance of a large array of Josephson junctions. The experimentally measured nonlinear resonance lineshapes of the junction array modes show significant deviations from steady-state numerical predictions, and necessitate time-dependent numerical simulations indicative of strong measurement-induced dephasing in the system arising from the large cross-Kerr effect between array modes. Analytical and numerical calculations of switching rate corroborate this by showing the emergence of a slow time scale, which is much longer than the linear decay rate and is set by fluctuation-induced switching times in the bistable regime. Furthermore, our analysis shows that the usual quantum-activated escape treatment is inadequate for prediction of the switching rates at large frequency shifts caused by strong nonlinearities, necessitating a quantum treatment that utilizes the full system Liouvillian. Based on our analysis, we identify a universal crossover parameter that delineates the regimes of validity of semiclassical and quantum descriptions, respectively. Our work shows how dynamical switching effects in strongly nonlinear systems provide a platform to study quantum-to-classical transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics↗

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from similar to 1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiNx at 150 GHz of tan delta similar to 4 x 10(-3) compared to 2.0 x 10(-3) and greater than or similar to 1 x 10(-3) measured at similar to 1 GHz using the other two methods. These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

Dielectrics loss↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward a DM Search with Phonon-Mediated MKID Devices at NEXUS

To continue the search for dark matter (DM) into the sub-GeV mass range, the development and characterization of new detectors with sub-eV thresholds is critical. Microwave Kinetic Inductance Detectors (MKIDs) offer an attractive architecture for novel microcalorimeters with the requisite energy resolution and threshold for probing DM down to the fermionic thermal relic mass limit of a few keV. A phonon-sensitive MKID device featuring an aluminum resonator patterned onto a silicon substrate has been operating at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. Currently, our estimate of the energy resolution of this device is limited by the efficiency for phonons produced via particle interactions in the substrate to propagate to the superconductor and break Cooper pairs. In this poster, I will present our constraints on the substrate-superconductor coupling and the progress on an absolute energy calibration performed by exposing the rear of the substrate to a pulsed source of 470 nm photons. I will also review the current status and next steps of the phonon-mediated MKID effort at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPT-SLIM: Line Intensity Mapping with the South Pole Telescope

Line-intensity mapping (LIM) at millimeter wavelengths is a powerful emerging probe of the large-scale structure of the Universe, but achieving meaningful constraints on cosmological parameters with LIM requires focal planes with orders of magnitudes more detectors than existing instruments. SPT-SLIM is an upcoming experiment to demonstrate LIM observations of CO at 0.5 < z < 2.0 using on-chip spectrometers with kinetic inductance detectors (KIDs), a new technology that enables scaling to the much larger arrays of detectors needed to probe cosmology. I will describe the overall experimental design and specific goals of SPT-SLIM. In addition, I will highlight results of the detector and readout electronics development for SPT-SLIM and the status of the camera integration and commissioning in the lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗