Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Five-Channel Infrared Laser Absorption Spectrometer for Combustion Product Monitoring Aboard Manned Spacecraft

Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.

Briggs, Ryan M.↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Relaxation of the V = 4,5,6,7, Sigma g/+/ vibrational levels of carbon monoxide studied by laser absorption.

The vibrational relaxation of individual vibration rotation levels of carbon monoxide behind incident shock waves of carbon monoxide has been studied by the method of laser absorption. For the particular vibrational states (V = 4 to 7) and temperature range (2500 to 5500 K) studied, it is concluded that the characteristic relaxation times are in excellent agreement with those obtained via previous measurements of 'bulk' gas properties. Further, the data furnish strong corroboration of the idea that the individual levels are in Boltzmann vibrational equilibrium during the relaxation process.

Chackerian, C., Jr.↗

Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling

Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.

Chang, Leyen S.↗

Shock Tube Characterization of Laser Absorption Sensors for Combustion Measurements of Green Propellants

Chemical kinetic models for green spacecraft propulsion systems are needed to calculate efficiency, estimate toxic products, and mitigate plume impingement risks. Laser absorption spectroscopy (LAS) is a common technique used to measure time-resolved mole fraction for model validation. LAS was used to measure species-time history nitrous oxide (N2O) and carbon monoxide (CO) behind reflected shock waves. The diagnostics were implemented at the University of Central Florida high-pressure shock tube facility. A mixture of ethylene (0.002) and N2O (0.008) was diluted with argon gas (0.99) and shock heated 12 bar and temperatures from 1400 to 1600 K.

Marley A. Albright↗

Tropospheric ozone distributions measured with an airborne laser absorption spectrometer

Measurements of tropospheric ozone have been made in the southern and middle California regions and over the Pacific Ocean during two series of flights in February and May 1977. The data were obtained by using a laser absorption spectrometer, a nadir-viewing instrument which remotely measures the ozone column abundance between ground level and aircraft altitude by interacting with ozone at specific wavelengths near 9.5 microns. The measurements indicate significantly lower ozone abundances above the Mojave Desert region as compared with farm, forest, and urban areas. The average tropospheric column density was found to be 0.0027 atm cm/km over the California region and 0.0035 atm cm/km over the Pacific Ocean region 1000-2000 km west of the coast of Mexico.

Menzies, R. T.↗

JPL Carbon Dioxide Laser Absorption Spectrometer Data Processing Results for the 2010 Flight Campaign

As a precursor to and validation of the core technology necessary for NASA's Active Sensing of CO2 Emissions over Nights, Days,and Seasons (ASCENDS) mission, we flew JPL's Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) in a campaign of five flights onboard NASA's DC-8 Airborne Laboratory in July 2010. This is the latest in a series of annual flight campaigns that began in 2006, and our first on the DC-8 aircraft.

Lidar↗

In situ ozone data for evaluation of the laser absorption spectrometer ozone remote sensor: 1979 southeastern Virginia urban plume study summer field program

Ozone data from the 1979 Southeastern Virginia Urban Study (SEV-UPS) field program are presented. The SEV-UPS was conducted for evaluation of an ozone remote sensor, the Laser Absorption Spectrometer. During the measurement program, remote-sensor evaluation was in two areas; (1) determination of the remote sensor's accuracy, repeatability, and operational characteristics, and (2) demonstration of the application of remotely sensed ozone data in air-quality studies. Data from six experiments designed to provide in situ ozone data for evaluation of the sensor in area 1, above, are presented. Experiments consisted of overflights of a test area with the remote sensor aircraft while in situ measurements with a second aircraft and selected surface stations provided correlative ozone data within the viewing area of the remote sensor.

Gregory, G. L.↗

Laser Absorption Spectroscopy Measurements of Post-Shock Non-Equilibrium Species in the NASA Ames Electric Arc Shock Tube

The NASA Ames Electric Arc Shock Tube (EAST) is a unique facility capable of generating high enthalpy, shock-heated impulse gas flows representative of the kinetic and radiative conditions encountered by atmospheric entry vehicles. The facility maintains a successful history with emission spectroscopy, providing measurements of absolute radiance upon which various validation studies are anchored. The central objective of this work is to develop a comprehensive tunable diode laser absorption spectroscopy (TDLAS) sensing capability to provide complementary experimental insights to existing emission techniques. More specifically, a fast-scanning TDLAS-based diagnostic targeting the cyano radical (CN) in the near-infrared(near-IR) near 926.6 nm is employed in mixtures of 2.2% CH4in N2by mole for a sweep of incident shock velocities ranging 3.0-5.5 km/s and fill pressures 0.3-1.15 Torr. Laser scan rates up to 500 kHz probe multiple absorption features to provide quantitative measurements of temperature and species number density profiles behind the incident shock. In all instances, the temperature trend is consistent between emission-inferred and TDLAS-inferred measurements. However, at the lower-velocity conditions, there is an appreciable offset between the Data Parallel Line Relaxation Code (DPLR) simulation and experimental measurements. A similar behavior is observed in number density profiles, with emission measurements providing inferences of the CN(B) and CN(A) state, while TDLAS measurements provide an additional inference of the CN(X) state. In the fast-scanned experiments, measurement inferred number densities suggest a much faster production of CN at early times than captured by the model. This discrepancy motivates ongoing, additional spectroscopic and kinetics CN experiments to resolve the accuracy of modeling assumptions.

Efaine Chang↗

Shock tube and laser absorption study of CO time-histories during combustion of branched alkenes

Combustion experiments of the three isomers of methyl butene compound - 2-methyl-1-butene (2M1B), 2-methyl-2-butene (2M2B), and 3-methyl-1-butene (3M1B), have been carried out in a shock tube using laser absorption technique. Carbon monoxide (CO) time-histories are obtained behind reflected shockwaves over the temperature range of 1350–1630 K near 9.3 atm with stoichiometric mixtures of 0.075% fuel in O2/Ar. Comparative study of CO time-histories reveals different rates of CO formation indicating different ignition delay time of the methyl butene isomers.

09 BIOMASS FUELS↗

Two-photon absorption laser induced fluorescence measurements of absolute neutral deuterium density, temperature, and bulk flow in Proto-MPEX

Neutral particle control is critical for fusion fueling and confinement. Neutral diagnostics for fusion-relevant plasmas are commonly restricted to line-integrated or ex situ methods. A non-perturbative, two-photon absorption laser induced fluorescence (TALIF) diagnostic is implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to probe neutral atomic deuterium in a fusion-relevant plasma at 1 cm intervals along the radius of the vacuum vessel. The diagnostic is situated ~20 m from the vacuum vessel, and a signal is collected along the laser injection axis, requiring only one line-of-sight. TALIF measurements are absolutely calibrated using xenon and krypton. Absolute atomic densities derived from xenon calibration are compared to absolute atomic densities derived from krypton calibration. In this work, preliminary measurements of absolute atomic deuterium density, temperature, and local bulk flow dependence on radial location and input power in Proto-MPEX are presented. Neutral atomic deuterium velocity distribution functions are measured throughout a one-second plasma pulse with a time resolution of 250 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Remote measurement of trace gases with the JPL laser absorption spectrometer

Extensive data from large regions are needed as a basis for the study of anthropogenic trace gases in the troposphere. The need arises, therefore, for an instrument which is capable to monitor rapidly the atmosphere in a region. The present investigation is concerned with the results of efforts to develop an instrument which is capable of remotely measuring gases in the troposphere. The Laser Absorption Spectrometer (LAS) was designed for use in aircraft, and was employed to measure tropospheric ozone distribution since 1977. Attention is given to a description of the LAS instrument, the theoretical basis of instrument operation, LAS measurement programs, the results of the LAS development program, and future work.

Shumate, M. S.↗

Intensity-Modulated Continuous-Wave Laser Absorption Spectrometer at 1.57 Micrometer for Atmospheric CO2 Measurements

Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc. proposes to use the intensity-modulated, continuous-wave (IM-CW) laser absorption spectrometer (LAS) approach for the ASCENDS mission. Prototype LAS instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space LAS systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW LAS system for the active space CO2 mission ASCENDS.

Lin, Bing↗

High temperature kinetic study of the reactions H + O2 = OH + O and O + H2 = OH + H in H2/O2 system by shock tube-laser absorption spectroscopy

The reactions: (1) H + O2 = OH + O; and (2) O + H2 = OH + H are the most important elementary reactions in gas phase combustion. They are the main chain-branching reaction in the oxidation of H2 and hydrocarbon fuels. In this study, rate coefficients of the reactions and have been measured over a wide range of composition, pressure, density and temperature behind the reflected shock waves. The experiments were performed using the shock tube - laser absorption spectroscopic technique to monitor OH radicals formed in the shock-heated H2/O2/Ar mixtures. The OH radicals were detected using the P(1)(5) line of (0,0) band of the A(exp 2) Sigma(+) from X(exp 2) Pi transition of OH at 310.023 nm (air). The data were analyzed with the aid of computer modeling. In the experiments great care was exercised to obtain high time resolution, linearity and signal-to-noise. The results are well represented by the Arrhenius expressions. The rate coefficient expression for reaction (1) obtained in this study is k(1) = (7.13 +/- 0.31) x 10(exp 13) exp(-6957+/- 30 K/T) cu cm/mol/s (1050 K less than or equal to T less than or equal to 2500 K) and a consensus expression for k(1) from a critical review of the most recent evaluations of k(1) (including our own) is k(1) = 7.82 x 10(exp 13) exp(-7105 K/T) cu cm/mol/s (960 K less than or equal to T less than or equal to 5300 K). The rate coefficient expression of k(2) is given by k(2) = (1.88 +/- 0.07) x 10(exp 14) exp(-6897 +/- 53 K/T) cu cm/mol/s (1424 K less than or equal to T less than or equal to 2427 K). For k(1), the temperature dependent A-factor and the correlation between the values of k(1) and the inverse reactant densities were not found. In the temperature range of this study, non-Arrhenius expression of k(2) which shows the upward curvature was not supported.

Ryu, Si-Ok↗

CO Laser Absorption Measurements During Syngas Combustion at High Pressure

Abstract Syngas is a desirable fuel for combustion in the Allam-Fetvedt cycle, which involves combustion under supercritical-CO2 conditions. While some work has been conducted in collecting ignition delay times (IDT) at the extreme pressures required by these systems, significant model deficiencies remain. Additionally, considerable barriers in terms of nonideal gas dynamic effects have been shown for these experiments in shock tubes. Further investigation into the fundamental combustion kinetics of H2/CO/CO2 mixtures is required. Time-resolved speciation measurements for target species have been shown to better aid in improving the understanding of underlying chemical kinetics than global ignition delay time measurements. Therefore, laser absorption measurements of CO were measured behind reflected shock waves during combustion of syngas at 5 and 10 bar and temperatures between 1080 and 2100 K. The mixtures investigated utilized H2-to-CO ratios of 1:1 and 1:4, respectively, each at stoichiometric conditions, allowing for discussions of the effect of initial fuel composition. A ratio of fuel to CO2 of 1:2 was also utilized to represent commercially available syngas. The mixtures were diluted in helium and argon (20% He, 76.5% Ar) to minimize thermal effects and to expedite CO thermal relaxation during the experiment. The resulting CO time histories were then compared to modern chemical kinetics mechanisms, and disagreement is seen for this system, which is assumed to be fairly well known. This study elucidates particular chemistry that needs improvement in moving toward a better understanding of syngas combustion at elevated pressures.

Engineering↗

Transient gain-versus-absorption laser probing of spin-orbit states, kinetics and dynamics

The spin-orbit populations of excited (2P1/2) and ground (2P3/2) state Br atoms at 2714 nm and I atoms at 1315 nm are examined using a tunable F-center laser and a diode laser. The transient laser gain-versus-absorption measurements are utilized to estimate quantum yields of the spin-orbit states in the photodissociation of Br- and I-containing compounds; the continuum yields for Br2 are investigated in terms of temperature. The collisional release, Doppler velocity effects, and differing reactivity of the spin-orbit excited and ground state atoms are studied. It is noted that the transient gain versus absorption technique is applicable to the analysis of kinetic phenomena due to its high sensitivity and excellent time resolution.

Smedley, John E.↗