Determination of As, Hg, S, and Se in liquid jets by laser-based optical diagnostic technique
Accepted version of FGD LIBS Applied Physics B manuscript
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Accepted version of FGD LIBS Applied Physics B manuscript
Explore the source record for details and available documents.
A deep-learning convolutional neural network (CNN) is used to infer, from x-ray images along multiple lines of sight, the low-mode shape of the hot-spot emission of deuterium–tritium (DT) laser-direct-drive cryogenic implosions on OMEGA. The motivation of this approach is to develop a physics-informed 3-D reconstruction technique that can be performed within minutes to facilitate the use of the results to inform changes to the initial target and laser conditions for the subsequent implosion. The CNN is trained on a 3D radiation-hydrodynamic simulation database to relate 2D x-ray images to 3D emissivity at stagnation. The CNN accounts for the lack of an absolute spatial reference and the different bands of photon energies in the x-ray images. While previous works studied the effect of mode-1 asymmetries on implosion performance using nuclear diagnostics, this work focuses on the effect of mode 2 inferred from x-ray diagnostics on implosion performance. A current analysis of 19 DT cryogenic implosions indicates there is an upper limit of ~20% reduction in the neutron yield caused by an ℓ = 2 amplitude for ℓ 2 /ℓ 0 ≤ 0.32. Here, these conclusions are supported by 2D simulations.
Both technical and simulation progress has been made toward implementing a laser inverse Compton scattering diagnostic on the DIII-D tokamak. This is a novel diagnostic which uses a short (sub-ns) pulse laser together with a fast (sub-ns) gated x-ray detector to measure relativistic electrons inside a tokamak plasma. The study of these relativistic electrons is important to make sure they can be removed from any tokamak-based power reactor, as they could damage vessel walls and cooling lines. This diagnostic is completely new for magnetic fusion research and has never been implemented before on a tokamak. It is found that good signals and radial profiles could be obtained with an optimized high-energy (7 Joule) laser. Using a standard off-the-shelf Nd:YAG (0.7 Joule) laser would give some signals above the noise but no ability to measure the relativistic electron radial profile.
The detection of the ionic products of low-rate fusion reactions, and in particular of the 11 B(p,α)2α, is one of the recognized main problems in experiments where these reactions are initiated by tailored interaction of intense and high-energy lasers with matter. A thorough description of this important issue, with a critical comparison of the diagnostic opportunities, is indeed so far. In this work, we describe the common diagnostic methodologies used for the detection of the alpha particles generated by the 11 B(p,α)2α reaction and, for each, we outline advantages and limitations, with considerations that can also be applied to other low-rate fusion reactions. We show here that, in general, the univocal characterization of the α products coming from this reaction can be achieved by the simultaneous use of several diagnostic tools placed in close proximity.
Laser wire has been used for nonintrusive profile and emittance measurements of operational hydrogen ion (H-) beam at the SNS linac. In this talk, we will describe the following recent developments in the laser wire system. 1) An upgraded light source and laser transport line which enables novel measurement capabilities including longitudinal profile measurement and high-energy proton beam extraction over potentially an entire macropulse. 2) A dual-detector emittance measurement scheme that boosted the dynamic range by an order of magnitude. 3) Design and implementation laser-wire-based nonintrusive longitudinal phase space measurement system.
Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.
This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.
This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.
The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved X-ray diffraction. FIDDLE currently incorporates five Icarus Ultrafast X-ray Imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ~10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from FCC to HCP and HCP to BCC. Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ~110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.
The National Laboratory of the Rockies (NLR) will conduct electrochemical testing and characterization on the partners lithium ion cells as well as provide and validate laser-ablated electrode materials for enhancing cell rate performance.
The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.
Ensuring the reliability of the NIF, including its support systems, laser systems, target diagnostic systems, and utilities, is essential to the availability of the NIF in its support of NNSA missions. NIF is a key capability in the DOE Stockpile Stewardship Program and supports high energy physics experiments for nuclear weapons, energy, and astrophysics applications. High system reliability provides opportunities for shots and scientific discoveries with opportunities to enhance and upgrade capabilities. This Maintenance Plan (MP) identifies the policies and procedures used to perform and support asset management of the NIF Facility and Infrastructure Systems (FInS), NIF Lasers & Alignment (LASE), NIF Target Experimental Operations (TOPS), NIF Target Area Science and Engineering (TASE), and NIF&PS Control Systems (NCS). The FInS systems include the facility, HVAC, contamination control, beampath, and Line Replaceable Units (LRUs) as well as utilities which create the beampath environments, such as vacuum, argon, or clean dry air. The LASE systems are Programmatic systems which include laser diagnostics, alignment, power conditioning, pulsed power, and input laser systems. The TOPS and TASE systems are also Programmatic systems which include target and diagnostic delivery systems and positioners, many different insertable and fixed target diagnostics, and cryogenic and target gas fill systems. Finally, the NCS systems include both software and hardware for industrial and shot operation control systems. Policies governing administrative and operational practices related to maintenance of FInS, LASE, TOPS, TASE, and NCS systems are described in this plan. In addition, the plan provides processes and procedures for managing, tracking, and documenting the work. This document, the NIF Operations Management Plan, NIF-5020544 (Ref. 1), and NIF Shot Operations Plan, NIF-5018506 (Ref. 2), together satisfy the requirements of the Conduct of Operations. Duties, responsibilities, and reporting requirements of the various positions associated with FInS, LASE, and TOPS maintenance are detailed in this plan. The FInS systems include both Real Property systems with asset management requirements specified in DOE Order 430.1C (Ref. 3) and Programmatic systems. In addition, for FInS, there is a list of the System Level Maintenance Plans (SLMPs) in NIF-1007419198 (Ref. 4) which provide the system descriptions and maintenance plan and schedule. In addition, the list includes the Reliability Centered Maintenance (RCM) and Experience Centered Maintenance (ECM) evaluations that have been performed for applicable FInS systems as well as reliability criticality per Section 3.5. The -AM version of the NIF Maintenance Plan focuses on the reliability program for FInS, LASE, TOPS, TASE, and NCS within the context of the overall NIF Reliability, Availability, and Maintainability (RAM) program and incorporates changes since the -AL version from August 2011 and has been updated to be fully consistent with the updates to Ref. 1. It also includes asset management considerations, updates to the Work Order (WO) process within the NIF Computerized Maintenance Management System (CMMS) which is EAM infor® System Maintenance and Reliability Tracking (SMaRT) (Ref. 5), and updates to metrics and key performance indicators (KPIs).
Many important chemically reacting systems are inherently multi-dimensional with spatial and temporal variations in the thermochemical state, which can be strongly coupled to interactions with transport processes. Fundamental insights into these systems require multi-dimensional measurements of the thermochemical state as well as fluid dynamics quantities. Laser-based imaging diagnostics provide spatially and temporally resolved measurements that help address this need. The state of the art in imaging diagnostics is continually progressing with the goal of attaining simultaneous multi-parameter measurements that capture transient processes, particularly those that lead to stochastic events, such as localized extinction in turbulent combustion. Development efforts in imaging diagnostics benefit from advances in laser and detector technology. This article provides a perspective on the progression of increasing dimensionality of laser-based imaging diagnostics and highlights the evolution from single-point measurements to 1D and 2D multi-parameter imaging and 3D high-speed imaging. This evolution is demonstrated using highlights of laser-based imaging techniques in combustion science research as an exemplar of a complex multi-dimensional chemically reacting system with chemistry–transport coupling. Imaging diagnostics impact basic research in other chemically reacting systems as well, such as measurements of near-surface gases in heterogeneous catalysis. The expanding dimensionality of imaging diagnostics leads to larger and more complex datasets that require increasingly demanding approaches to data analysis and provide opportunities for increased collaboration between experimental and computational researchers in tackling these challenges.
We report a study of the process of nonlinear Thomson scattering (NTS) of a tightly focused relativistically intense laser pulse by an ensemble of electrons simulating the result of ionisation of an ultrathin nanofoil. The description of all six components of a laser pulse is based on the Stratton – Chu integrals describing radiation focused by an off-axis parabolic mirror into a spot down to the diffraction limit, which is of practical interest for modern experiments with extreme-intensity lasers, including diagnostics of their parameters. The interaction of a laser pulse with electrons is simulated by the test-particle method, and the resulting trajectories are used to calculate the characteristics of secondary electromagnetic radiation. The effect of the laser-pulse focal spot diameter in the range λ – 6λ on the angular distributions of the radiated energy and NTS spectra, as well as of a laser-beam peak intensity of 10{sup 21} – 10{sup 22} W cm{sup −2} on the spectral width of the secondary radiation is studied in relation to the experimentally implemented focusing scheme using the example of a laser pulse with an initial homogeneous spatial distribution and a duration of ∼25 fs. (interaction of laser radiation with matter. laser plasma)
Soot emissions in combustion are unwanted consequences of burning hydrocarbon fuels. The presence of soot during and following combustion processes is an indication of incomplete combustion and has several negative consequences including the emission of harmful particulates and increased operational costs. Efforts have been made to reduce soot production in combustion engines through utilizing oxygenated biofuels in lieu of traditional nonoxygenated feedstocks. The ongoing Co-Optimization of Fuels and Engines (Co-Optima) initiative from the US Department of Energy (DOE) is focused on accelerating the introduction of affordable, scalable, and sustainable biofuels and high-efficiency, low-emission vehicle engines. The Co-Optima program has identified a handful of biofuel compounds from a list of thousands of potential candidates. In this study, a shock tube was used to evaluate the performance of soot reduction of five high-performance biofuels downselected by the Co-Optima program. Current experiments were performed at test conditions between 1,700 and 2,100 K and 4 and 4.7 atm using shock tube and ultrafast, time-resolve laser absorption diagnostic techniques. The combination of shock heating and nonintrusive laser detection provides a state-of-the-art test platform for high-temperature soot formation under engine conditions. Soot reduction was found in ethanol, cyclopentanone, and methyl acetate; conversely, an α-diisobutylene and methyl furan produced more soot compared to the baseline over longer test times. For each biofuel, several reaction pathways that lead towards soot production were identified. The data collected in these experiments are valuable information for the future of renewable biofuel development and their applicability in engines.
Abstract Ion microscopy is an established technique for laser focus diagnostics and the accurate, intensity-resolved measurement of laser ionization processes. In the present feasibility study, we discuss a new ion microscope design, which improves its resolution across a large range of magnifications and simplifies its operation. Instead of the common two einzel lens configuration, which is usually optimized for a fixed magnification, we propose a generic design consisting of an array of equally spaced ring electrodes, whose individually adjustable voltages are controlled by an evolutionary algorithm. In this way, we can realize aberration minimized magnifications between 25 and 100. Moreover, the algorithm can adjust the voltage settings under changing experimental conditions and facilitates autofocusing for user-defined magnification.