Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser x-ray radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solidification cracking of laser melted commercial-purity tungsten

The high melting temperature of tungsten (W) makes it an attractive candidate for energy generation applications; however, its use is limited by its poor ductility at low temperatures. This limitation affects even melt-based additive manufacturing (AM) processes such as laser powder bed fusion (PBF-LB), with as-fabricated pure W exhibiting both longitudinal and transverse cracks. Metallurgical and processing factors that affect these cracks are still being explored. This work utilizes powderless single-tracks on pure W plates made over a range of power and velocity combinations in three unique PBF-LB setups: one with flowing argon, one with continuous vacuum, and an in situ high-speed synchrotron X-ray radiography setup. Each had different oxygen activities in their build environments. Longitudinal cracks with oxides appearing to exude from the crack were found for tracks deposited in a build environment with argon shield gas, while no such cracks were observed for builds conducted in vacuum. A calculation showed that direct oxygen ingress into the melt pool from the build environment is negligible when argon shield gas is present. Thus, incorporation of spatter is a likely mechanism for oxygen ingress into the melt pool. Radiography showed extensive keyholing, spatter generation, and crack formation at keyhole porosity. A heat transfer calculation showed the crack formation time was consistent with cooling below its ductile-to-brittle transition (DBT) temperature. This work identifies solidification cracking as a feasible mechanism in pure W beyond the well-known DBT related cracking.

Materials science↗

Nondestructive Testing As a Tool in the Space Shuttle Columbia Accident Investigation

Nondestructive testing (NDT) played a crucial role in determining the Columbia tragedy's cause. Over 84,000 pieces of debris were recovered; hundreds were subsequently subjected to NDT and materials analysis. Visual NDT of the debris revealed localized areas of damage such as erosion, excessive heating, knife edging and mechanical damage. Three-dimensional reconstructions were made of the left wing leading edge, utilizing a tripod-mounted laser scanning head and focused laser beam, and an advanced topometric optical scanner (ATOS) with digital white light to scan complex-shaped debris, producing monochrome 3-D models. Texture mapping provided a means to capture true colors of the debris and superimpose them on the scanned images. Uniform deposits were found over large portions of debris, obscuring underlying materials. To determine what was beneath, inverse radiography was enlisted. The radiographs guided investigators to where samples should be taken. To ascertain compositions, these samples were subjected to analytical testing, including energy dispersive X-ray spectroscopy and electron microprobe analysis. This combination of visual evidence, radiography, virtual reconstruction, and materials analysis allowed the forensic scientists to verify that a breach occurred in the leading edge of the left wing, the path the plasma followed, and the sequence of events that led to the loss.

McDanels, Steve↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Multi-Probe 24A: Post shot Data and Analysis

The Multi-Probe 24A experiments took place on the Omega EP laser in November 2023. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron ion beams from a range of film thicknesses, and x-ray sources from the established CPC+Ta wire targets. The backlighter was used for ion acceleration in the pitcher series, in which deuteron and proton beams characterized as a function of CD film thickness to develop a pitcher for a pitcher-catcher neutron radiographic source, while also characterizing electrons and x-rays emitted perpendicular to the target (i.e. Crosstalk for sidelighter-driven x-ray beams). The sidelighter was used for electron acceleration in the x-ray series, in which the electron acceleration and subsequent x-rays was characterized from the CPC+Ta wire targets and radiography was conducted with and without electro-magnetic electron defection. For the pitcher series, we found that at 500 J and 0.7 ps the 700-800 nm CD films yielded the greatest number and highest energy for both protons and deuterons. For the x-ray series, results demonstrated: a significant number of <100 keV x-rays are produced within the glue that fills the CPC cone, on-axis electron signal from the x-ray targets produce electrons resolvable up to ~10 MeV, and electron deflection (using MIFEDS) has a notable effect radiograph on noise reduction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing turbulence with lasers and coherent light sources

Fluid and plasma turbulence consists of multi-scale interactions where the energy of the large scales is dissipated through a cascade to the smallest scales set by the microphysics. Turbulence and mixing can be detrimental to system performance, such as in inertial confinement fusion (ICF). Our current understanding of turbulence is mostly derived from studies of incompressible flows, where the intermediate-scaled eddies in the “inertial range” bridge the transfer of energy from the large eddies to the dissipative range, and that there is no communication between eddies of disparate scales. Whether a similar cascade process exists for compressible turbulence, however, remains to be seen; experiments have been limited by diagnostics and supersonic flow facilities. This project has focused on the development of techniques to measure the evolution of flows and microphysical transport properties using particle tracking velocimetry. This project has investigated three main areas: (1) particle-tracking experiments with x-ray radiography, (2) shock-particle interactions, (3) quantifying viscous effects on particles in shocked flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Analytical model for balling defects in laser melting using rivulet theory and solidification

In laser welding and additive manufacturing communities, the balling (humping) defect is primarily attributed to the Plateau–Rayleigh fluid instability (PRI) with a few authors suggesting fluid jetting and volume conservation as alternative mechanisms. As analytical descriptions of these mechanisms are unavailable, combining them into a single formalism is unfeasible. We present a new model of PRI with higher accuracy, accounting for competition with solidification, to compare the expected behavior with known experimental trends when fluid jetting is neglected. We adapt a rivulet instability model from fluid physics to account for the stabilizing effects of the substrate, which the traditional cylindrical-jet geometry does not account for and estimate the instability growth rate. Our model yields a continuous transition from non-balling to balling hitherto lacking in current literature and predicts instability growth at higher wavelengths with strong sensitivity to the solidification front curvature. While the fluid surface is most unstable for shallow melt pools, the absolute magnitude of balling relevant to printing defects scales with melt pool depth and has a maximum for a given melt pool geometry. Synchrotron-based x-ray radiography of thin samples indicates that PRI growth rates and solidification can be comparable in magnitude and thus compete, as we find in this work. We predict that deviations between model predictions and our experimental results demonstrate the importance of fluid flows and heat transport in the balling process. Our experiments further demonstrate at least one mechanism by which the melt pool length and the balling wavelength are not equivalent, as commonly claimed.

Taylor, Z. [Stanford Univ., CA (United States); SL↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nondestructive Evaluation of Foam Insulation on the Space Shuttle External Tank

Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased interest in other causes of foam loss following the flight of Discovery in July 2005, laser shearography was added to the techniques used for inspecting ET foam. The shearography method records a sheared image of a laser speckle pattern projected on a test part before And after some sort of excitation. The resultant fringe pattern allows the slope of the out of plane displacement to be measured. For crushed and delaminated foam applications, a non-contact air coupled acoustic force is used to excite the surface of the foam. Regions without defects tend to respond differently to the sound energy than do regions with defects, generating a map of the foam integrity. Foam crushed to a depth of about 0.1 inches is detectable with shearography even after it has relaxed to its original shape.

Richter, Joel↗

Advances in laser-based bremsstrahlung x-ray sources. I. Optimizing laser-accelerated electrons

In this work, we have performed a suite of kinetic simulations of relativistic laser–plasma interaction under settings relevant to recent and planned experiments on a variety of laser systems. The goal of the study is to illuminate the physics of laser–target coupling and to provide guidance for how to optimize these sources for applications. It is shown that the production of relativistic electrons is maximized when conditions of relativistic induced transparency (RIT) in dense plasmas can be achieved over a large interaction volume at the time of arrival of most intense part of the laser pulse. RIT is shown to enhance both the numbers of relativistic electrons and the energies of the electrons, leading to an increased x-ray dose. A variety of approaches to enhancing laser–target coupling are considered. These include optimizing the effects of low-density pre-plasma (arising either from finite laser pedestal or from the use of foam coatings) and of modifying the laser focusing geometry to reduce effects of filamentation and self-focusing. Evidence of a novel approach to achieving stable laser propagation over distances of tens of micrometers in a plasma gradient is also presented. These conditions coincide with plasma and laser conditions explored in recent experiments on the Omega EP laser system and compare favorably with an analytic criterion for stable laser propagation in relativistically underdense plasma obtained from a nonlinear Wentzel–Kramers–Brillouin analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Assessing the performance of MagLIF with 3D MHD simulations

The Magnetized Liner Inertial Fusion (MagLIF) experimental platform at Sandia National Laboratories has realized a number of recent improvements in electrical current and laser preheat coupling but fusion yields are below expectations, based on modeling with clean (that is, simulations with no interfacial instabilities and no mix) two-dimensional (2D) magneto-hydrodynamics (MHD) simulations, by a factor of 5 or more. However, magnetized liner implosions are known to produce helical magneto-Rayleigh–Taylor (MRT) modes and complex stagnation structures that cannot be directly modeled in 2D. This paper presents the results of 3D HYDRA MHD simulations, including helical MRT, showing that degradation from these instabilities can readily reproduce experimental yields, but it is difficult to simultaneously match the yield along with inferred fuel temperature, pressure, and burn history (assessed with x-rays), which are larger in the experiments considered here. Additional analysis methods and future experiments are proposed to help address the discrepancies. The 3D simulations also show, without substantive improvements to stability, changing the applied Bz or preheat is unlikely to increase performance of MagLIF to the same degree as clean 2D simulations. Finally, the first 3D HYDRA simulations with the Hall term show the ab initio production of helical MRT and produce a clear change in stagnation morphology compared to pre-seeded simulations without Hall. In spite of the differences, the simulations still produce comparable fusion performance but with longer, lower power, neutron yield history.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗