Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm circumference (4500 bristles/in. circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

Carlile, Julie A.↗

Investigation of Turbulent Tip Leakage Vortex in an Axial Water Jet Pump with Large Eddy Simulation

Detailed steady and unsteady numerical studies were performed to investigate tip clearance flow in an axial water jet pump. The primary objective is to understand physics of unsteady tip clearance flow, unsteady tip leakage vortex, and cavitation inception in an axial water jet pump. Steady pressure field and resulting steady tip leakage vortex from a steady flow analysis do not seem to explain measured cavitation inception correctly. The measured flow field near the tip is unsteady and measured cavitation inception is highly transient. Flow visualization with cavitation bubbles shows that the leakage vortex is oscillating significantly and many intermittent vortex ropes are present between the suction side of the blade and the tip leakage core vortex. Although the flow field is highly transient, the overall flow structure is stable and a characteristic frequency seems to exist. To capture relevant flow physics as much as possible, a Reynolds-averaged Navier-Stokes (RANS) calculation and a Large Eddy Simulation (LES) were applied for the current investigation. The present study reveals that several vortices from the tip leakage vortex system cross the tip gap of the adjacent blade periodically. Sudden changes in local pressure field inside tip gap due to these vortices create vortex ropes. The instantaneous pressure filed inside the tip gap is drastically different from that of the steady flow simulation. Unsteady flow simulation which can calculate unsteady vortex motion is necessary to calculate cavitation inception accurately even at design flow condition in such a water jet pump.

Hah, Chunill↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Monitoring of helium gas leakage from canister storing spent nuclear fuel: Radiological consequences and management

Chloride-induced stress corrosion cracking (CISCC) of canisters has been identified as a potential degradation mechanism requiring ageing management — especially in a marine air environment. Methods for monitoring helium gas leakage from canisters have been developed on the basis of a phenomenon that the bottom temperature of the canister increases as the top temperature of the canister decreases when helium gas leaks during storage. In this paper, we consider the radiological consequences of CISCC based on two scenarios of helium gas leakage and propose effective management that includes a timeline for monitoring and mitigation. Monitoring helium gas leakage by measuring the difference in temperature between canister surfaces in the dry cask storage of spent fuel (SF) can detect leakage before SF undergoes oxidation as a result of air ingress and before country-specific regulatory limits of off-site doses are exceeded, thereby enabling mitigatory action.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field-scale fault reactivation experiments by fluid injection highlight aseismic leakage in caprock analogs: Implications for CO 2 sequestration

Observations on tens-of-meter scale experiments of fault activation by fluid injection conducted in shales allow exploring how aseismic and seismic events may jeopardize the integrity of a sealing caprock overlying a CO 2 sequestration reservoir. We contrast the behavior of shale faults with another set of experiments conducted in carbonates. Significant fluid leakage occurs along the initially low-permeability shale faults when rupture is activated. Most of the leakage pathway closes when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed leakage behavior, which is also caused by fault opening favored by the softness of the shale, and by the structure of the fault zone that prevents fluids from diffusing into the adjacent damage zone. Experiments show a large amount of aseismic deformation. Small-magnitude seismicity (M w < -2.5) is observed outside the pressurized leakage patch. Stress transferred from this aseismic deformation patch can build up to stress-criticality and favor seismicity. Thus, in terms of fault activation in caprocks, aseismic fault slip leading to increased permeability and a loss of seal integrity is of great concern.

58 GEOSCIENCES↗

Interpretive modeling of tungsten divertor leakage during experiments with neon gas seeding

Abstract Many existing and future tokamaks with tungsten divertors operate, or will operate, with low- Z impurity seeding, but the direct effect of these seeded impurities on tungsten Scrape-off-Layer (SOL) transport has not been explored in detail. This paper reports on a DIII-D experiment designed to test how tungsten divertor leakage from the Small-Angle Slot V-Shaped, tungsten-coated divertor is impacted by neon seeding at a variety of injection rates and poloidal injection locations. Measurements from the experiment show an inverse relationship between the neon injection rate and the tungsten core penetration factor. Interpretive modeling is performed with a combination of the SOLPS-ITER and DIVIMP codes to assess the underlying tungsten behavior. The modeling results show that the reduction in tungsten divertor leakage is driven by both an increase in the divertor collisionality as well as a reduction in the ion temperature gradient near the divertor target. Collisions between low- Z impurities and tungsten impurities are found to have a significant impact on the tungsten SOL transport, such that ignoring the low- Z impurity collisional effects on the tungsten transport can result in an overestimate of the divertor leakage by an order-of-magnitude. Given the importance of these localized interactions, neon seeding from the closed, slot-like divertor has a clear advantage in being able to reduce tungsten divertor leakage without the high levels of neon core contamination that occur when seeding from other poloidal locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Normal or abnormal? Machine learning for the leakage detection in carbon sequestration projects using pressure field data

The international commitments for atmospheric carbon reduction will require a rapid increase in carbon capture and storage (CCS) projects. The key to any successful CCS project lies in the long term storage and prevention of leakage of stored carbon dioxide (CO 2 ). In addition to being a greenhouse gas, CO 2 leaks reaching the surface can accumulate in low-lying areas resulting in a serious health risk. Among several alternatives, some of the more promising CCS storage formations are depleted oil and gas reservoirs, where the reservoirs had good geological seals prior to hydrocarbon extraction. With more CCS wells coming online, it is imperative to implement permanent, automated monitoring tools. We apply machine learning models to automate the leakage detection process in carbon storage reservoirs using rates of (CO 2 ) injection and pressure data measured by simple harmonic pulse testing (HPT). To validate the feasibility of this machine learning based workflow, we use data from HPT experiments carried out in the Cranfield oil field, Mississippi, USA. The data consist of a series of pulse tests conducted with baseline parameters and with an artificially introduced leak. Here, in this study, we pose the leakage detection task as an anomaly detection problem where deviation from the predicted behavior indicates leaks in the reservoir. Results show that different machine learning architectures such as multi-layer feed forward network, Long Short-Term Memory, and convolutional neural network are able to identify leakages and can provide early warning. These warnings can then be used to take remedial measures.

58 GEOSCIENCES↗

Unraveling the conundrum of electronic leakage in protonic ceramic cells: Operation-specific insights and rational design strategies

Electronic conduction through proton-conducting electrolytes significantly impairs the efficiency of protonic ceramic cells (PCCs). Here, in this study, we explore the electron and ion mixed transport properties of four common protonic ceramics, BaZr 0.8 Y 0.2 O 3-δ (BZY82), BaZr 0.7 Ce 0.2 Y 0.1 O 3-δ (BZCY721), BaZr 04 Ce 0.4 Y 0.1 Yb 0.1 O 3-δ (BZCYYb4411), and BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ (BZCYYb1711). It marks the first instance of investigating these properties under operation-specific scenarios: fuel side of electrolysis cell, air side of electrolysis cell, fuel side of fuel cell, and air side of the fuel cell. BZCYYb1711 exhibits the highest ionic conductivity, but two to three times higher electronic leakage when exposed to oxygen-containing environments than the others. BZY82 exhibits approximately two times higher electronic leakage in a hydrogen-containing environment. BZCY721 demonstrates excellent ion transport numbers (~0.95) across these four operating conditions. BZCYYb4411 behaves quite similarly to BZCY721. The most challenging operating environment for all candidates is the air side of fuel cell mode. This mode leads to a high initial electronic leakage, followed by a significant increase with polarization. The probable cause for this behavior is a H 2 -free, polarization-induced reduction that leads to the formation of V$^•_O$. The electron small polaron associated with V$^•_O$ is released by the electrical field due to the Poole-Frenkel effect. ZnO and NiO sintering aids are found to be detrimental to the ionic conductivity of the electrolytes. In particular, NiO substantially lowers the ion transport number. The correlation of the operation-specific electronic leakage to full cells is discussed. It is suggested that a rational PCC design should synergistically couple BZCYYb1711 at fuel side with BZCY4411 at air side to deliver a well-balanced performance and faradaic efficiency simultaneously, and the high temperature sintering process with a NiO fuel electrode should be shortened or replaced by ultra-fast sintering techniques or using a fuel electrode scaffold-infiltration fabrication strategy.

42 ENGINEERING↗

BeyondPlanck X. Bandpass and beam leakage corrections

We discuss the treatment of bandpass and beam leakage corrections in the Bayesian BeyondPlanck CMB analysis pipeline as applied to the Planck LFI measurements. As a preparatory step, we first apply three corrections to the nominal LFI bandpass profiles including removal of a known systematic effect in the ground measuring equipment at 61 GHz; smoothing of standing wave ripples; and edge regularization. The main net impact of these modifications is an overall shift in the 70 GHz bandpass of +0.6 GHz; we argue that any analysis of LFI data products, either from Planck or BeyondPlanck, should use these new bandpasses. In addition, we fit a single free bandpass parameter for each radiometer of the form Δ i = Δ 0 + $δ$ i , where Δ 0 represents an absolute frequency shift per frequency band and $δ$i is a relative shift per detector. The absolute correction is only fitted at 30 GHz with a full $\chi$ 2 -based likelihood, resulting in a correction of Δ 30 = 0.24 ± 0.03 GHz. The relative corrections are fitted using a spurious map approach, fundamentally similar to the method pioneered by the WMAP team, but without introducing many additional degrees of freedom. All bandpass parameters are sampled using a standard Metropolis sampler within the main BeyondPlanck Gibbs chain, and bandpass uncertainties are thus propagated to all other data products in the analysis. In total, we find that our bandpass model significantly reduces leakage effects. For beam leakage corrections, we adopt the official Planck LFI beam estimates without additional degrees of freedom, and only marginalize over the underlying sky model. We note that this is the first-time leakage from beam mismatch has been included for Planck LFI maps.

79 ASTRONOMY AND ASTROPHYSICS↗

Circuit-Based Leakage-to-Erasure Conversion in a Neutral-Atom Quantum Processor

Atom-loss errors are a major limitation of current state-of-the-art neutral-atom quantum computers and pose a significant challenge for scalable systems. In a quantum processor with cesium atoms, we demonstrate proof-of-principle circuit-based conversion of this form of leakage error to erasure errors via leakage-detection units (LDUs), which nondestructively map information about the presence or absence of the qubit onto the state of an ancilla. We benchmark the performance of the LDU using a three-outcome low-loss state-detection method and find that the LDU detects atom-loss errors with approximately 93.4% accuracy, limited by technical imperfections of our apparatus. We further compile and execute a SWAP LDU, wherein the roles of the original data atom and ancilla atom are exchanged under the action of the LDU, providing “free refilling” of atoms in the case of atom loss. This circuit-based leakage-to-erasure error conversion is a critical component of a neutral-atom quantum processor where the quantum information may significantly outlive the lifetime of any individual atom in the quantum register. Finally, we demonstrate that LDUs may also be used to handle other forms of leakage errors where population moves to states outside of the computational subspace.

Chow, Matthew N. H. [Sandia National Laboratories ↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

Semi-Analytical Leakage Solutions for Aquifers (SALSA) v1

SALSA is a semi-analytical modeling tool that can provide assessments of pressure perturbations and brine leakage because of fluid injection and extraction activities in sedimentary basins. Sedimentary basins typically contain vertical sequences of near-horizontal aquifers separated by less-permeable aquitards. In the context of geologic carbon sequestration (GCS), while aquitards are relied upon to contain injected buoyant free-phase CO2 and limit inter-aquifer brine flow, the large number of leaky wells (e.g., unused/unsuccessful exploration wells, or improperly plugged water or oil/gas wells) that are present in sedimentary basins creates concerns for potential leakage and groundwater contamination. The mathematical theory and solution method included in SALSA is presented in our recent manuscript under review. SALSA is the first to account for the coupled leakage through aquitards and leaky wells, with geologic pressurization sources. SALSA based on semi-analytical solutions can be computationally very efficient for problems containing many injection and leaky wells in multilayered sedimentary systems, compared to any numerical simulation software requiring local mesh refinement around each well to obtain accurate results. Therefore, stakeholders (e.g., regulators, operators) for site screening, injection and post-injection pressure behavior and assessing leakage risks can use SALSA as a fast-predictive tool in GCS applications in multilayered aquifer systems.

Cihan, Abdullah↗

MR13A-3183: Microbial and Geochemical Characterization of Groundwater: Implications for Underground Hydrogen Storage Leakage

Underground hydrogen storage (UHS) in geological formations is a key element of the clean energy transition as it enables the decarbonization of the transportation and industrial sectors by decoupling hydrogen production and storage. UHS has many benefits, including low cost, much wider availability, large storage capacity, well-established infrastructure, and increased safety because of geological sealing capabilities. However, the impact of hydrogen (H2) biogeochemical interactions in the presence of subsurface microorganisms is largely neglected from UHS perspectives. These interactions might affect the effectiveness of storage and can even cause H2 to leak into the shallow aquifers. Leakage of H2 into groundwater can change the geochemistry and induce several microbial-driven processes. Microorganisms, such as sulfate-reducers, are naturally abundant in groundwater and consume H2 to produce hydrogen sulfide (H2S), which can contaminate the freshwater drinking groundwater and cause damage to infrastructure. Hydrogen leakage can also trigger microbial reactions responsible for metal mobility, which can impact the water quality. However, the kinetics of these reactions and the temporal impact of hydrogen leakage in groundwater are still unknown. Therefore, a time series hydrogen-groundwater interaction experiment was conducted, and the changes in fluid chemistry and headspace gas composition will be analyzed along with DNA sequencing results to understand the extent and kinetics of biogeochemical reactions that occur if hydrogen leaks into groundwater. In the experiments, Ultra High Purity (UHP) hydrogen gas will be injected into glass vials with groundwater samples, for a designated time period. For each glass-sealed vial, 16S rRNA gene sequencing, IC, ICP-MS, and GC-TCD will be performed. The experiments provide insights into plausible impacts of hydrogen leakage into shallow drinking water aquifers.

Clark, Allison [West Virginia University (WVU)]↗

Measurements of the atmospheric neutron leakage rate

The atmospheric neutron leakage rate in the energy range from 0.01 to 10,000,000 eV has been measured as a function of latitude, altitude, and time with a neutron detector on board the Ogo 6 satellite. The latitude dependence of the neutron leakage is in reasonable agreement with that predicted by Lingenfelter (1963) and Light et al. (1973) if the neutron energy spectrum has the shape calculated by Newkirk (1963). The change in the neutron latitude dependence with the cosmic ray modulation agrees with the predictions of Lingenfelter and Light et al. For several solar proton events enhancements were observed in the neutron counting rates at lambda greater than or equal to 70 deg. Such events, however, provide an insignificant injection of protons at E less than or equal to 20 MeV into the radiation belts. An isotropic angular distribution of the neutron leakage in the energy range from 0.1 keV to 10 MeV best fits the observed altitude dependence of the neutron leakage flux.

Lockwood, J. A.↗

Effects of leakage through clearance seals on the performance of a 10 K Stirling-cycle refrigerator

The use of clearance seals is essential to achieve long life, wear free operation of Stirling cycle cryogenic refrigerators. The effect of leakage through clearance seals on the performance of such a refrigerator operating at temperatures ranging from 20 K down to 10 K was determined. The ability of a Stirling cycle refrigerator to achieve 10 K with clearance seals was successfully demonstrated. It is indicated that the leakage flow undergoes gap regeneration before reaching the cold expansion volume. A simple model of gap regeneration was used to estimate the regeneration loss due to the leakage flow. This regeneration process minimizes the loss in refrigerator performance caused by the clearance seal leakage. It is found that clearance seals remain effective down to a refrigeration temperature of 10 K.

Keung, C. S.↗