Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

A general framework for removing point-spread function additive systematics in cosmological weak lensing analysis

ABSTRACT Cosmological weak lensing measurements rely on a precise measurement of the shear two-point correlation function (2PCF) along with a deep understanding of systematics that affect it. In this work, we demonstrate a general framework for detecting and modelling the impact of PSF systematics on the cosmic shear 2PCF and mitigating its impact on cosmological analysis. Our framework can detect PSF leakage and modelling error from all spin-2 quantities contributed by the PSF second and higher moments, rather than just the second moments, using the cross-correlations between galaxy shapes and PSF moments. We interpret null tests using the HSC Year 3 (Y3) catalogs with this formalism and find that leakage from the spin-2 combination of PSF fourth moments is the leading contributor to additive shear systematics, with total contamination that is an order-of-magnitude higher than that contributed by PSF second moments alone. We conducted a mock cosmic shear analysis for HSC Y3 and find that, if uncorrected, PSF systematics can bias the cosmological parameters Ωm and S8 by ∼0.3σ. The traditional second moment-based model can only correct for a 0.1σ bias, leaving the contamination largely uncorrected. We conclude it is necessary to model both PSF second and fourth moment contaminations for HSC Y3 cosmic shear analysis. We also reanalyse the HSC Y1 cosmic shear analysis with our updated systematics model and identify a 0.07σ bias on Ωm when using the more restricted second moment model from the original analysis. We demonstrate how to self-consistently use the method in both real space and Fourier space, assess shear systematics in tomographic bins, and test for PSF model overfitting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seal-rotordynamic-coefficient test results for a model SSME ATD-HPFTP turbine interstate seal with and without a swirl brake

The predictions of Scharrer's (1988) theory for rotordynamic coefficients of labyrinth gas seals were compared with measurements for a model SSME Alternate Turbopump Development High-Pressure Fuel Turbopump with and without swirl brakes. Using the test apparatus described by Childs et al. (1986, 1990), tests were conducted with supply pressures up to 18.3 bars and speeds up to 16,000 rpm. Seal back pressure was controlled to provide four pressure ratios at all supply pressures. No measurable difference in leakage was detected for the seal with and without the swirl brakes. Comparisons of the measurement results for the seal without a swirl brake with the Scharrer theory showed that the theory can be used only to provide design guidelines; systematic differences were observed between theory and experiment due to changes in running speed, supply pressure, and pressure ratio.

Childs, D. W.↗

Seal-rotordynamic-coefficient Test Results for a Model SSME ATD-HPFTP Turbine Interstage Seal with and Without a Swirl Brake

The predictions of Scharrer's (1988) theory for rotordynamic coefficients of labyrinth gas seals were compared with measurements for a model SSME Alternate Turbopump Development High Pressure Fuel Turbopump with and without swirl brakes. Using the test apparatus described by Childs et al., tests were conducted with supply pressures up to 18.3 bars and speeds up to 16,000 rpm. Seal back pressure was controlled to provide four pressure ratios at all supply pressures. No measurable differences in leakage was detected for the seal with and without the swirl brakes. Comparisons of the measurement results for the seal without a swirl brake with the Scharrer theory showed that the theory can be used only to provide design guidelines; systematic differences were observed between theory and experiment due to changes in running speed, supply pressure, and pressure ratio.

Childs, Dara W.↗

Alternatives to Silicon Rubber Thermal Barrier in RSRM Nozzle Joints

Thiokol Propulsion encountered a situation where gas path can form in the Filler material in joints between the phenolic in the Space Shuttle Reusable Solid Rocket Motor nozzle. An investigation determined that the method for injecting the filler material into the joint created a pressurized pocket of air that forced its way to the surface while the filler was curing. The path that the air took remained open some situations leaving a path for hot gas to get deep into the joint. The condition that created the gas path has been corrected by modifications to the manufacturing process, but a design solution that would reduce processing time is being pursued. A strip of open cell installed deep into the joint, can serve as a barrier to the Filler material. Testing indicates that the foam eliminates the pressure pocket, and does not prevent detection of leakage of the o-ring seals during leak test. Open cell foam does not have thermal resistance capability and mechanical structure, which would be required in the event of a gas path. A replacement to open cell foam is now being considered. Braided carbon fiber rope has the permeability characteristics of foam and it has thermal resistance characteristics as well. Braided carbon fiber rope (BCFR) has been tested in simulated joints in subscale rocket motor. Results of the testing indicate that braided carbon fiber rope can significantly reduce gas temperature by as much es 3000 F in a nozzle joint configuration. BCFR can be installed as a barrier to stop the joint filler material or it can used as the thermal barrier alone.

Totman, Peter D.↗

Leak Detector

Ni-Tec unit is a modified version of the Lixiscope, a small, battery-powered, portable X-ray instrument. Unit is used as a portable device capable of detecting radioactive leakage. If there were a leak, the radioactivity would illuminate the units viewing screen and identify the source of the leak; in the absence of radioactivity the screen shows nothing.

Source record↗

Underground sources of drinking water chemistry changes in response to potential CO 2 leakage

The purpose of this study was to quantify changes to underground sources of drinking water (USDW) quality in response to potential CO 2 leakage from geologic CO 2 sequestration (GCS) reservoirs. Here, the developed a framework of combined laboratory experiments and reactive transport simulations and used this framework to evaluate the Ogallala aquifer overlying the Farnsworth Unit (FWU), an active GCS site, as a case study. Using chemical reaction parameters obtained from laboratory experiments and numerical simulations, site-specific mechanisms of CO 2 -water-sediment interactions at the USDW aquifer were interpreted. Long-term risks of potential CO 2 leakage were then evaluated with field-scale numerical models using the regional hydrogeological characteristics and reaction parameters obtained from our experiments and simulations. Results suggest that carbonate mineral impurity and cation exchange are key mechanisms for interactions between CO 2 and the aquifer sediment. Additionally, for a large leakage rate of 0.1 % injection from one leaky well, the leakage plume might impact an area of 300 m in diameter and significantly affect the local water quality by changing pH and cation concentrations (e.g., Zn, Ba and Sr). After leakage ceases, the zone of impacted fluids would not migrate significantly in subsequent decades due to a low regional groundwater flowrate (for this case study). The relatively small area of impact might not be detected in a monitoring well given the broader spacing in a typical field scenario. Effective early leakage detection may require additional tools, e.g., borehole CO 2 movement, four-dimensional seismicity, CO 2 soil flux, samples from deeper aquifers, etc., to ensure effective leakage detection and long-term safety of GCS projects.

58 GEOSCIENCES↗

Chemical Impacts of Potential CO2 and Brine Leakage on Groundwater Quality with Quantitative Risk Assessment: A Case Study of the Farnsworth Unit

Potential leakage of reservoir fluids is considered a key risk factor for geologic CO2 sequestration (GCS), with concerns of their chemical impacts on the quality of overlying underground sources of drinking water (USDWs). Effective risk assessment provides useful information to guide GCS activities for protecting USDWs. In this study, we present a quantified risk assessment case study of an active commercial-scale CO2-enhanced oil recovery (CO2-EOR) and sequestration field, the Farnsworth Unit (FWU). Specific objectives of this study include: (1) to quantify potential risks of CO2 and brine leakage to the overlying USDW quality with response surface methodology (RSM); and (2) to identify water chemistry indicators for early detection criteria. Results suggest that trace metals (e.g., arsenic and selenium) are less likely to become a risk due to their adsorption onto clay minerals; no-impact thresholds based on site monitoring data could be a preferable reference for early groundwater quality evaluation; and pH is suggested as an indicator for early detection of a leakage. This study may provide quantitative insight for monitoring strategies on GCS sites to enhance the safety of long-term CO2 sequestration.

58 GEOSCIENCES↗

NRAP Recommended Practices for Containment Assurance and Leakage Risk Quantification

This report presents recommendations for quantitatively assessing and managing leakage risk and effective containment assurance at geologic carbon storage (GCS) sites, amidst uncertainty in site characteristics and performance. These recommended practices are a product of the U.S. Department of Energy’s (DOE) Office of Fossil Energy and Carbon Management’s National Risk Assessment Partnership (NRAP)—a multi-year collaborative research effort of Lawrence Berkeley National Laboratory, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, National Energy Technology Laboratory, and Pacific Northwest National Laboratory. These recommended practices are organized as a set of conceptual workflows that correspond with the stages of the GCS project lifecycle. They consider aspects of site characterization, quantification of potential leakage, assessing the spatial extent of potential environmental impacts, optimizing monitoring design for detection of potential leakage, evaluation of concordance between monitored and forecasted reservoir response, assessing conformance with expected/accepted performance, and determination of the timeline over which risk of impactful leakage can be expected to abate. These conceptual workflows are intended to aid stakeholders in making risk management decisions at GCS sites and to support development of sound, risk-based justifications for characterizing the subsurface, defining area of potential leakage impact, designing site monitoring plans, selecting leakage risk management/mitigation alternatives, and estimating site closure timelines.

54 ENVIRONMENTAL SCIENCES↗

CEV OME/RCS Flow Health Monitor: Status Review

I. Primary purpose: detect propellant valve leakage: a) Reduce launch propellant mass by reducing leakage loss . margins, b) Improve safety by reducing risk of propellant ice build up in thruster. II. Secondary objectives: a) Wetness sensor to detect that lines have been flooded. b) Monitor engine performance (timing, mix ratio). c) Use in GSE as valve leakage monitor.

Youngquist, Robert↗

Optical Detection Of Cryogenic Leaks

Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

Wyett, Lynn M.↗

Application of quantitative risk assessment to address stakeholder questions in geologic carbon storage

Ambitious international greenhouse gas emissions reduction targets demand a rapid transformation to a low-carbon economy. This transformation includes the accelerated adoption of carbon dioxide (CO2) capture and storage (CCS) technology. However, as with any large-scale engineering enterprise, the widespread commercial-scale deployment of geologic carbon storage (GCS) raises important questions about technology and cost-effectiveness, safety, environmental risk, and long-term liability. Effectively assessing and managing risks and liability associated with GCS projects is a key technical need throughout the project life cycle-from site selection and permitting to monitoring design, operational risk management, and post-operational site closure. This presentation highlights recent advancements in tools for quantitative risk assessment, being developed by the National Risk Assessment Partnership (NRAP). NRAP is a multi-year, multinational laboratory research collaboration sponsored by the U.S. Department of Energy's Office of Fossil Energy and Carbon Management. Our focus will be on these tools' applications in addressing critical stakeholder questions related to supporting permitting to ensure secure and environmentally protective storage; designing effective and efficient monitoring plans; evaluating the effectiveness of remedial actions and risk management alternatives; and informing liability assessment and investment decisions. This paper will detail the key functionality of NRAP’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), a computational framework for assessing leakage risk and containment assurance. This model features streamlined workflows for calculating leakage risk profiles, delineating risk-based area of review, and assessing contingency plans and post-injection site care requirements. ORION is an open-source, observation-based ensemble forecasting toolkit to help operators assess the seismic hazard at a carbon storage site. The State of Stress Analysis Tool (SOSAT), designed to assess subsurface stress conditions and evaluate geomechanical risk resulting from CO2 injection in an area of interest will also be presented. We will also introduce a prototype model to evaluate storage project costs and liability associated with risk management. The Technoeconomic and Liability Evaluation for Storage (TALES) model uses results from forecasts of leakage and induced seismicity risk to estimate the lifecycle cost of managing risk. Finally, a preliminary example of how the NRAP Risk-based Adaptive Monitoring Plan (RAMP) tool can be used to design efficient and effective site monitoring plans and estimate the detectability of fluid leakage will be provided. The relevance of these tools for addressing key stakeholder questions amidst uncertainty will be emphasized.

decision support↗

Predictive Modeling and Uncertainty Quantification in Condition Monitoring of Active Components: A Reactor Coolant Pump Use Case

This work develops data-driven models for onset of thermal barrier leakage in reactor coolant pumps. It incorporates uncertainty quantification to enhance the reliability and robustness of pre- dictions. Using synthetic data generated by the Generic Pressurized Water Reactor simulator, realistic degradation scenarios were simulated across lifecycle stages—beginning, middle, and end of life. Key variables, including differential pressure, flow rate, vibration, and temperatures, were analyzed using machine learning framework. The fully connected neural network models demonstrated exceptional performance, achieving R2 scores exceeding 0.99 and root mean square errors as low as around 8.23 × 10-2 gallon per minute (gpm) for the three stages of the lifecy- cle. UQ analysis further validated the model’s robustness, with narrow uncertainty bounds during steady-state operations and appropriately wider bounds during transitional phases, reflecting the physical behavior of the system. This work addresses important gaps in real-time condition moni- toring and regulatory compliance by integrating advanced condition monitoring technologies with UQ into IST programs. The ability to detect thermal barrier leakage early and quantify prediction reliability supports optimizing maintenance strategies while ensuring nuclear power plants’ safe and reliable operation.

99 - GENERAL AND MISCELLANEOUS↗

pnnl/dream_v3

The Designs for Risk Evaluation and Management (DREAM) tool was developed as part of the effort to quantify the risk of geologic storage of carbon dioxide (CO2) under the U.S. Department of Energy’s National Risk Assessment Partnership (NRAP). DREAM is an optimization tool created to identify optimal monitoring schemes that minimize the time to first detection of CO2 leakage from a subsurface storage formation. DREAM acts as a post-processer on user-provided output from subsurface leakage simulations. While DREAM was developed for CO2 leakage scenarios, it is applicable to any subsurface leakage simulation of the same output format

Kupis, Shyla↗

The recognition of extraterrestrial artificial signals

Considerations in the design of receivers for the detection and recognition of artificial microwave signals of extraterrestrial origin are discussed. Following a review of the objectives of SETI and the probable reception and detection characteristics of extraterrestrial signals, means for the improvement of the sensitivity, signal-to-noise ratios and on-line data processing capabilities of SETI receivers are indicated. The characteristics of the signals likely to be present at the output of an ultra-low-noise microwave receiver are then examined, including the system background noise, terrestrial radiations, astrophysical radiations, accidental artificial radiations of terrestrial origin, and intentional radiations produced by humans and by extraterrestrial intelligence. The classes of extraterrestrial signals likely to be detected, beacons and leakage signals, are considered, and options in the specification of gating and thresholding for a high-spectral resolution, high-time-resolution signal discriminator are indicated. Possible tests for the nonhuman origin of a received signal are also pointed out.

Seeger, C. L.↗

Power monitoring in space nuclear reactors using silicon carbide radiation detectors

Space reactor power monitors based on silicon carbide (SiC) semiconductor neutron detectors are proposed. Detection of fast leakage neutrons using SiC detectors in ex-core locations could be used to determine reactor power: Neutron fluxes, gamma-ray dose rates and ambient temperatures have been calculated as a function of distance from the reactor core, and the feasibility of power monitoring with SiC detectors has been evaluated at several ex-core locations. Arrays of SiC diodes can be configured to provide the required count rates to monitor reactor power from startup to full power Due to their resistance to temperature and the effects of neutron and gamma-ray exposure, SiC detectors can be expected to provide power monitoring information for the fill mission of a space reactor.

silicon carbide detectors↗

Investigative techniques used to locate the liquid hydrogen leakage on the Space Shuttle Main Propulsion System

Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.

Hammock, William R., Jr.↗