Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

A Workflow for Characterizing Legacy Wells as Potential Leakage Pathways for Integration to NRAP-Open-IAM

Carbon capture and storage is a crucial component of climate change mitigation strategies, involving the capture of carbon dioxide (CO2) from point sources and its injection into permeable subsurface formation. Many suitable CO2 storage sites coincide with legacy wells since the conditions that kept hydrocarbons in-situ for thousands of years are also ideal for storage of carbon dioxide. To protect underground sources of drinking water (USDW) during greenhouse gas injection, the Environmental Protection Agency (EPA) mandates area of review evaluations. These evaluations ensure that drinking water sources would not be contaminated by injected fluids. They include identification of legacy wellbores, integrity assessments, and implementing any necessary corrective action. Previous assessment approaches of legacy wells include high-level scoring of regional data and well construction and abandonment evaluation. This work describes a novel methodology that evaluates well construction and abandonment, ranks them based on complexity, and performs a risk assessment with NRAP-Open-IAM. A workflow of the methodology is presented, highlighting its capabilities and limitations.

Wise, Jarrett↗

An adaptable technique for comparative image assessment: Application to crosswell electromagnetic survey design for fluid monitoring

Reservoir integrity stewardship accompanying carbon capture and sequestration considers fluid extraction and reinjection as a risk-mitigating method against overpressuring that could lead to caprock damage and ensuing [Formula: see text] leakage. Crosswell electromagnetics offers a technically viable monitoring method with the spatial volume coverage necessary for reservoir-encompassing pressure management. However, a certain logistic dilemma for deep gas sequestration into saline and thus electrically conductive aquifers is that crosswell magnetic-field measurements underperform in the imaging of more resistive plume bodies, further exacerbated when vertical arrays intersect, as opposed to surround, plumes. Furthermore, comparative synthetic-data plume imaging of such scenarios rates the information content of magnetic-field versus electric-field 3D crosswell layouts for reservoir and infrastructure conditions of a representative pilot site in a coastal area in Florida. The image quality of the resulting plume replications can be ranked numerically through a newly proposed semblance qualifier, appraising the model goodness of fit to a given reference. In contrast to common least-squares measures for goodness of fit, the semblance formulation uses classifying logistic function types, thus enabling a better distinction of predefined anomaly features.

58 GEOSCIENCES↗

A Gas Management System for an Ultra Long Duration Titan Blimp

This paper presents analyses, designs and experimental results for the gas management system of a hydrogen-filled blimp capable of flying in the lower atmosphere of Titan for a period of one year or more. The engineering strategy has two basic elements: first, to minimize leakage rates from the blimp envelope and ballonets; and second, to provide auxiliary subsystems to mitigate the life-limiting effects resulting from those leaks. Leak minimization is achieved through use of cryogenically compatible balloon materials and adhesives, and selection of ballonet geometries that minimize pinhole generation via folding and material fatigue. Hydrogen loss to the environment through leaks in the blimp envelope is compensated for by producing new hydrogen through chemical processing of atmospheric methane. Nitrogen leaked into the blimp from the ballonets is removed by a carbon absorption system and periodically vented to the atmosphere. Data is presented on the measured leak rate from a full scale (13 m long) prototype blimp envelope and on the performance of a low mass, low power prototype device that generates hydrogen from methane. These results are factored in to an overall system design that quantifies the mass and power requirements for a minimum one year operational lifetime.

aerobot↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Anomalous Transients in Chip Polymer Tantalum Capacitors

Contrary to MnO2 tantalum capacitors, transient processes in polymer tantalum capacitors after voltage application might result in anomalously high, ampere-level currents when a capacitor might appear as a short circuit for a time that is much greater than a transient time in MnO2 capacitors. In this work, conditions that cause anomalous transients in different types of polymer tantalum capacitors have been analyzed. Related phenomena that included increasing of capacitance and dissipation factors with voltage, parametric surge current test failures without damage to capacitors, and increasing leakage currents at low temperatures are described. It has been shown that anomalous transients increased substantially with applied voltage and with reduction of moisture content in capacitors caused by storage or operation at high temperatures and/or in vacuum. Different types of capacitors exhibited different level of transients and modification of conductive polymers or process of their application might decrease transient leakage currents substantially. For space applications, the risk of failures related to anomalous transients can be mitigated by special testing procedures to select parts with an acceptable level of transients and by voltage derating.

Tantalum Capacitors↗

Intern Deliverable Poster 2025

An Incident Response Plan (IRP) is a document that is created and maintained by an organization that provides guidance in the event of a cyber incident. The primary objectives of an IRP are to aid in the detection, response, and recovery from incidents, as well as to enhance preparation and preventative measures. An IRP should outline specific procedures at each stage of an incident, with the goal of minimizing asset damage, data leakage, and operational impact. By investing in a well-defined IRP, organizations can better manage and mitigate risks associated with cyber threats, ensuring business continuity and resilience. This poster summarizes incident response guidelines for wind energy, which faces unique cybersecurity and physical challenges.

17 - WIND ENERGY↗

Peening Techniques for Mitigating Chlorine-Induced Stress Corrosion Cracking of Dry Storage Canisters for Nuclear Applications

Fusion-welded austenitic stainless steel (ASS) was predominantly employed to manufacture dry storage canisters (DSCs) for the storage applications of spent nuclear fuel (SNF). However, the ASS weld joints are prone to chloride-induced stress corrosion cracking (CISCC), a critical safety issue in the nuclear industry. DSCs were exposed to a chloride-rich environment during storage, creating CISCC precursors. The CISCC failure leads to nuclear radiation leakage. Therefore, there is a critical need to enhance the CISCC resistance of DSC weld joints using promising repair techniques. This review article encapsulates the current state-of-the-art of peening techniques for mitigating the CISCC in DSCs. More specifically, conventional shot peening (CSP), ultrasonic impact peening (UIP), and laser shock peening (LSP) were elucidated with a focus on CISCC mitigation. The underlying mechanism of CISCC mitigation in each process was summarized. Finally, this review provides recent advances in surface modification techniques, repair techniques, and developments in welding techniques for CISCC mitigation in DSCs.

Chemistry↗

Surface Cancellation in Wideband Ground Penetrating Radar Employing Genetic Algorithm AI for Waveform Synthesis

This paper presents a wideband 600-1200 MHz ground penetrating radar (GPR) system for sub-surface exploration of the moon and other planetary bodies. The presented radar system uses an arbitrary waveform generator (AWG) to directly produce the frequency-modulated continuous wave (FMCW) chirp waveform. To address the key challenges of Tx-to-Rx leakage and surface reflections, the system uses a second AWG channel coupled directly to the receiver that provides a cancellation waveform to mitigate the unwanted signals. The system also uses a genetic algorithm AI engine which assesses the radar IF and iteratively improves the parameters of the cancellation waveform injected at the receiver.

Chang, Frank↗

Paragenetic controls on CO 2 -fluid-rock interaction and weakening in a macroporous-dominated sandstone

The injection and storage of anthropogenic CO 2 in the subsurface is being deployed as a climate change mitigation tool; however, diagenetic-paragenetic heterogeneity in sandstone reservoirs often contributes to interval specific chemomechanical changes that affect injection and can increase leakage risk.In this paper we address reservoir heterogeneities’ impact on chemomechanical changes in a macroporous-dominated lithofacies of Morrow B sandstone, a formation containing several diagenetically-distinct hydraulic facies while undergoing enhanced oil recovery (EOR) and carbon dioxide (CO 2 ) sequestration. We performed three flow-through experiments using a CO 2 -charged or uncharged formation water combined with four indirect tensile strength tests per post-test sample. We then used the microstructure and paragenetic sequence to understand chemomechanical weakening with key observations as follows: dissolution of carbonates and feldspars changed porosity; increased permeability led to reclassifying each sample in a different hydraulic flow unit; decreased ultrasonic velocity; and did not lead to a loss of tensile strength. Tensile strength maintenance occurred due to the low abundance and minor dissolution of siderite, the stability of quartz, and the relative position of diagenetic ankerite within feldspar. This macroporous-dominated lithofacies is the primary reservoir for the Morrow B Sandstone, and is analogous to other porous sandstone reservoirs. It represents an end-member of a chemomechanically low-risk siliceous CO 2 sequestration and CO 2 -EOR reservoir.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO2 Capture Strategies via Mineralization with Industrial Waste Brines

Large coal-fired power plants (>500 MW) account for 30% of global CO2 emissions, and long-term management of this CO2 to is urgently needed mitigate global temperature increases. Sequestration of CO2 within stable mineral carbonates (e.g., CaCO3) represents an attractive emission reduction strategy because it offers a leakage-free alternative to geological storage of CO2 in an environmentally friendly form. We have previously described a mineralization process in which divalent cations are sourced from various waste streams (e.g., produced water and brackish water) and alkalinity is induced via regenerable ion-exchange materials (Bustillos et. al. Frontiers in Energy Research. 2020, 8, 352). In our process, aqueous carbonate-bearing streams with pH > 8 are produced by contacting fresh water and carbon dioxide with various ion-exchange materials (e.g., Na form zeolites or ion exchange resins). These streams are mixed with produced water containing varying concentrations (~0.01 – 1.0 M) of Ca2+ leading to the precipitation of solid calcium carbonate (PCC). This process has the advantages of using regenerable solids in a simple and continuous process to increase the pH of water by ion exchange instead of relying on the consumption of costly and unsustainable sources of alkalinity (e.g., sodium hydroxide). While once-through column experiments showed the above benefits, the same were yet to established in a steady-state process with recycle streams. In this work, we set up a process simulation to quantify the energy requirements and CO2 emissions associated with the process and seek optimal produced water compositions and CO2 concentrations (5 – 20 vol%). The process simulation was set up in ASPEN Plus using eRNTL as the thermodynamic property method and sequential modular strategy. Ion exchange alkaline solution was simulated using sodium hydroxide and validated against the experimental data obtained from once-through kinetic experiments. Nanofiltration and reverse osmosis membrane steps were also implemented for the separation of divalent cations and production of fresh water and a regeneration stream following mineralization. Sensitivity analysis was carried out using a range of produced water compositions (0.01 – 1.0 M Ca2+, 0.001 – 0.15 M Mg2+, 0.5 – 3.5 M Na+ and 0.0004 – 0.002 M Fe2+) according to the United States Geological Survey (USGS) database. Calcium carbonate yields increased with increasing CO2 concentrations and were maximized using produced water compositions with larger Ca2+ concentrations. Maximum calcium carbonate yields produced at 5 vol%, 12 vol% and 20 vol% CO2 were 2.3 mmol/L, 5.5 mmol/L, and 9.3 mmol/L, respectively, with the formation of brucite (a magnesium hydroxide phase, Mg(OH)2) and goethite (an iron hydroxide phase, FeOOH) as the primary contaminant phases (99% calcite, 0.6% brucite, 0.4% goethite), which agree with phases detected by XRD experimentally. These results indicate high purity calcium carbonate can be precipitated using industrial waste streams. Consequentially, energy consumption and net CO2 emissions were minimized where precipitated calcium carbonate was maximized for all produced water compositions and CO2 concentrations. Minimum energy consumptions were 0.21 kWh/ton CO2 processed, with 98% of the energy input required coming from the membrane filtration steps. Produced water compositions with large Na+ concentrations (> 0.5 M) were effective at reducing energy consumptions due to faster regeneration time of ion exchange materials. Additionally, calculated net CO2 emissions were negative for the process and ranged from -0.02 kg/ton CO2 to -0.15 kg/ton CO2 processed, indicating a low emission process. We will also present techno-economic assessment showing the economic benefits of the current process as an alternative to the addition of stoichiometric bases to induce alkalinity for the precipitation of CaCO3.

Simonetti, Dante↗

Unveiling the influence of selective-area-regrowth interfaces on local electronic properties of GaN p-n junctions for efficient power devices

Here, we report correlated nanoscale mapping of the structure, composition, and properties of regrown GaN p-n junctions to identify how etching and non-planar regrowth processes limit diode performance via the introduction of unintentional dopants and defect states. p-GaN was selectively regrown in n-GaN trenches with SiO 2 masks of variable mask-to-trench-width ratio. Dilute Al layers were periodically introduced during regrowth as markers of the growth interface. Correlated nanoscale mapping of doping, conductivity, and dopant complexes was achieved with atom probe tomography (APT), scanning spreading resistance microscopy (SSRM), and cathodoluminescence (CL) spectroscopy, respectively. The Al marker layers, detected by APT, enabled reconstruction of the faceted growth interface and correlation of the dopant concentration with position and time. The p-GaN growth rate is proportional to the mask-to-trench width ratio while the dopant incorporation rate is invariant. At trench edges, magnesium incorporation is suppressed, and oxygen incorporation enhanced, due to preferential incorporation on the semi-polar growth surface, leading to compensation and less abrupt p-n junctions; the SiO 2 mask is a source of oxygen. Residual etch damage below the regrowth interface induces n-type and p-type conductivity, creating leakage pathways. The non-uniform Mg incorporation is driven by crystal anisotropy and is thus inherent to non-planar regrowth, but can be mitigated by engineering the regrowth interface and process parameters. The unprecedented integration of spatially resolved mapping of dopants, impurities, conductivity, and carrier type is a powerful approach to discriminating distinct factors that limit the performance of regrown diodes, enabling the rational optimization of process and device design.

36 MATERIALS SCIENCE↗

Multi-physics modeling of injected nanoparticles effect on remediation of CO 2 leakage through cracks

One potential risk in CO 2 sequestration is the leakage of carbon dioxide, which can result in contamination of underground water, creating potential threats to existing ecosystems. The common leakage pathway is through the pre-existing fractures or discontinuities within cement in the wellbore, incurred by the environmental conditions imposed on the cement. Injecting nanoparticles into pre-existing cracks is one of the most recently proposed ideas for mitigating fracture propagation in cement CO 2 sequestration. To demonstrate the feasibility of this new technology, a numerical approach was taken in this work, as it is challenging to investigate it in a laboratory setting. We proposed a coupled ALE (Arbitrary Lagrangian–Eulerian)–DEM (Discrete Element Method)–peridynamic modeling strategy within the LS-Dyna package to investigate the intertwined interaction among the CO 2 fluid flow, native fluid (e.g., brine), particle clusters, and cracks within the cement. The numerical results demonstrate that injected nanoparticles can effectively reduce the pressure exerted on the crack surface. Accordingly, the potential fracture propagation at the crack tip would be reduced compared to corresponding cases without nanoparticels as pressurized by fluid flow. This result verifies the effectiveness of proposed nanoparticle injection technology. Finally, using this established modeling strategy, the effect of filling particles on the fracture mitigation for different crack geometries (e.g. particle cluster patterns, aspect ratio of crack aperture and length) and CO 2 reservoir pressure are examined. The result shows that injected particles successfully reduce the fracture propagation in these scenarios.

42 ENGINEERING↗

Evaluating Acoustic vs. AI-Based Satellite Leak Detection in Aging US Water Infrastructure: A Cost and Energy Savings Analysis

The aging water distribution system in the United States, constructed mainly during the 1970s with some pipes dating back 125 years, is experiencing significant deterioration leading to substantial water losses. Along with the potential for water loss savings, improvements in the distribution system by using leak detection technologies can create net energy and cost savings. In this work, a new framework has been presented to calculate the economic level of leakage within water supply and distribution systems for two primary leak detection technologies (acoustic vs. satellite). In this work, a new framework is presented to calculate the economic level of leakage (ELL) within water supply and distribution systems to support smart infrastructure in smart cities. A case study focused using water audit data from Atlanta, Georgia, compared the costs of two leak mitigation technologies: conventional acoustic leak detection and artificial intelligence–assisted satellite leak detection technology, which employs machine learning algorithms to identify potential leak signatures from satellite imagery. The ELL results revealed that conducting one survey would be optimum for an acoustic survey, whereas the method suggested that it would be expensive to utilize satellite-based leak detection technology. However, results for cumulative financial analysis over a 3-year period for both technologies revealed both to be economically favorable with conventional acoustic leak detection technology generating higher net economic benefits of USD 2.4 million, surpassing satellite detection by 50%. A broader national analysis was conducted to explore the potential benefits of US water infrastructure mirroring the exemplary conditions of Germany and The Netherlands. Achieving similar infrastructure leakage index (ILI) values could result in annual cost savings of $\$4$–$\$4.8$ billion and primary energy savings of 1.6–1.9 TWh. These results demonstrate the value of combining economic modeling with advanced leak detection technologies to support sustainable, cost-efficient water infrastructure strategies in urban environments, contributing to more sustainable smart living outcomes.

acoustic leak detection↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

TCCSP Task 6 Risk Assessment Report

For this Risk Assessment Plan, TCCSP has conducted a site-based risk assessment that quantifies the risk of CO 2 and/or brine leakage as a result of CO 2 injection at TCCSP. The risk assessment covers project planning, construction, injection, post-injection periods and closure of TCCSP. Key technical and non-technical Project risks are identified as part of the Risk Workshop and include a thorough evaluation of related scenarios. Mitigation strategies for the identified risk scenarios are defined to develop a scientifically sound, and community acceptable CO 2 storage Project.

58 GEOSCIENCES↗