Search NASA⌕ Search

SEARCH · Search NASA

Results for “light shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fast Light-Sheet Scanner

Optomechanical apparatus maintains sheet of pulsed laser light perpendicular to reference axis while causing sheet of light to translate in oscillatory fashion along reference axis. Produces illumination for laser velocimeter in which submicrometer particles entrained in flow illuminated and imaged in parallel planes displaced from each other in rapid succession. Selected frequency of oscillation range upward from tens of hertz. Rotating window continuously shifts sheet of light laterally while maintaining sheet parallel to same plane.

Hunter, William W., Jr.↗

Planar Particle Imaging and Doppler Velocimetry System and Method

A planar velocity measurement system (100) is operative to measure all three velocity components of a flowing fluid (106) across an illuminated plane (108) using only a single line of sight. The fluid flow is seeded with small particles which accurately follow the flow field fluctuations. The seeded flow field is illuminated with pulsed laser light source (102) and the positions of the particles in the flow are recorded on CCD cameras (122,124). The in-plane velocities are measured by determining the in-plane particle displacements. The out-of-plane velocity component is determined by measuring the Doppler shift of the light scattered by the particles. Both gas and liquid velocities can be measured, as well as two-phase flows.

Wernet, Mark P.↗

Laser Light Scattering Diagnostic for Measurement of Flow Velocity in Vicinity of Propagating Shock Waves

A laser light scattering diagnostic for measurement of dynamic flow velocity at a point is described. The instrument is being developed for use in the study of propagating shock waves and detonation waves in pulse detonation engines under development at the NASA Glenn Research Center (GRC). The approach uses a Fabry-Perot interferometer to measure the Doppler shift of laser light scattered from small (submicron) particles in the flow. The high-speed detection system required to resolve the transient response as a shock wave crosses the probe volume uses fast response photodetectors, and a PC based data acquisition system. Preliminary results of measurements made in the GRC Mach 4, 10 by 25 cm supersonic wind tunnel are presented. Spontaneous condensation of water vapor in the flow is used as seed. The tunnel is supplied with continuous air flow at up to 45 psia and the flow is exhausted into the GRC laboratory-wide altitude exhaust system at pressures down to 0.3 psia.

Seasholtz, Richard G.↗

Ultraviolet spectroscopy of R Coronae Borealis

Observations of the hydrogen-deficient supergiant R CrB were obtained with the IUE over an interval of 54 days in order to study the nature of this star's irregular, small-amplitude variations in light. By chance, the series of observations coincided with a dip in the light intermediate between the normal fluctuations and the deep declines associated with the formation of an obscuring dust cloud. High-resolution spectra have been used to search for radial velocity variations, while low-resolution spectra yield ultraviolet light curves down to 1810 A. Both types of spectra have been analyzed for indications of temperature changes. It is found that a combination of photospheric temperature variation and variable extinction is necessary to account for the details of the observations. A simple, ad hoc, periodic model is presented in which the amount of obscuring dust varies in proportion to the drop in temperature, but at a later time, reproduces the wavelength dependence of both the amplitudes and phase shifts of the light curves. The radial velocities are consistent with pulsation being responsible for the temperature variation.

Holm, A. V.↗

Development of Point Doppler Velocimetry for Flow Field Investigations

A Point Doppler Velocimeter (pDv) has been developed using a vapor-limited iodine cell as the sensing medium. The iodine cell is utilized to directly measure the Doppler shift frequency of laser light scattered from submicron particles suspended within a fluid flow. The measured Doppler shift can then be used to compute the velocity of the particles, and hence the fluid. Since this approach does not require resolution of scattered light from individual particles, the potential exists to obtain temporally continuous signals that could be uniformly sampled in the manner as a hot wire anemometer. This leads to the possibility of obtaining flow turbulence power spectra without the limitations of fringe-type laser velocimetry. The development program consisted of a methodical investigation of the technology coupled with the solution of practical engineering problems to produce a usable measurement system. The paper outlines this development along with the evaluation of the resulting system as compared to primary standards and other measurement technologies.

Cavone, Angelo A.↗

Closed loop fiber optic rotation sensor

An improved optical gyroscope is provided, of the type that passes two light components in opposite directions through an optic fiber coil, and which adds a small variable frequency to one of the light components to cancel the phase shift due to rotation of the coil. The amount of coil rotation from an initial orientation, is accurately determined by combining the two light components, one of which has a slightly increased frequency, to develop beats that each represent a predetermined angle of rotation. The direction of rotation is obtained by combining the two light components on a photodetector, intermittently phase shifting a single light component by 90 deg and comparing the direction of change of photodetector output (+ or -) caused by the 90 deg shift, with the slope (+ or -) of the photodetector output at about the same time, when there is a 90 deg shift.

Goss, Willis C.↗

Air-mass flux measurement system using Doppler-shifted filtered Rayleigh scattering

An optical system has been investigated to measure mass flux distributions in the inlet of a high speed air-breathing propulsion system. Rayleigh scattered light from air is proportional to the number density of molecules and hence can be used to ascertain the gas density in a calibrated system. Velocity field measurements are achieved by spectrally filtering the elastically-scattered Doppler-shifted light with an absorbing molecular filter. A novel anamorphic optical collection system is used which allows optical rays from different scattering angles, that have different Doppler shifts, to be recorded separately. This is shown to obviate the need to tune the laser through the absorption to determine velocities, while retaining the ability to make spatially-resolved measurements along a line. By properly selecting the laser tuning and filter parameters, simultaneous density measurements can be made. These properties are discussed in the paper and experiments demonstrating the velocimetry capability are described.

Shirley, John A.↗

Biochronometry; Proceedings of the Symposium, Friday Harbor, Wash., September 4-6, 1969.

Topics discussed include circadian activity rhythms in birds and man, variation of circadian rhythms in monkeys, resetting of circadian eclosion rhythm in fruitflies, the effectiveness of mathematical models of circadian rhythms, the influence of ac electric fields on circadian rhythms in man, the relation between changes in the metabolic rate and circadian periodicity of the resistance of pocket mice to ionizing radiation, the relation between circadian organization and the photoperiodic time measurement in moths, the circadian rhythm of optic nerve potentials in the isolated eye of the sea hare, phasing of circadian temperature rhythms in the pocket mouse by specific spectral regions, the phase-shifting effect of light on circadian rhymicity in the fruifly, hormonal control of circadian rhythms in the fruitfly, metabolically controlled temperature compensation in the circadian rhythm of algae, and circadian rhythms in the chloroplasts of algae. Individual items are abstracted in this issue.

Menaker, M.↗

Occultation studies of planets and satellites: The occultation of epsilon Geminorum by Mars

The occultation of epsilon Geminorum by Mars on 1976 April 8 was observed at three wavelengths and 4 ms time resolution with the 91 cm telescope. Temperature, pressure, and number density profiles of the Martian atmosphere were obtained for both the immersion and emersion events. Within the altitude range of 50 to 80 km above the mean surface, the mean temperature is 145 K, and the profiles exhibit wavelike structures with a peak to peak amplitude of 35 K and a vertical scale of about 20 km. The ratio of the refractivity of the atmosphere at 4500 A and 7500 A, determined from the time shift of the light curves for these wavelengths, is consistent with the atmospheric composition measured by Viking 1, 15 weeks later. From the central flash - a bright feature in the light curve midway between immersion and emersion - an optical depth is found at 4500 A of 3.3 plus or minus 1.7 per km atm (about 0.23 per equivalent Martian air mass) for the atmosphere about 25 km above the mean surface, near the south polar region. This large value and its weak wavelength dependence rule out Rayleigh scattering as the principal cause of the observed extinction.

Elliot, J. L.↗

The trapped mercury ion frequency standard

Singly ionized mercury atoms have a structure similar to neutral alkali atoms. They can be maintained as ions for very long times in an RF quadrupole ion trap. Thus, their ground state hyperfine structure can be used to make a frequency standard using optical pumping techniques similar to the well-known rubidium standard. The mass 199 isotope of mercury has an ionic hyperfine structure of 40.5 GHz. In a trap system a linewidth of 10 Hz has been measured. An expression is presented for the short-term stability of a proposed mercury standard as set by the achieved signal to noise ratio. There is prospect of further improvement. Long-term stability is affected by second order doppler effect, and by pressure, light, and Stark shifts. However, these appear either sufficiently small or sufficiently controlable that the proposed mercury ion standard would be competitive with existing standards.

Mcguire, M. D.↗

Repeatable, multiple-peaked structure in Type I X-ray bursts

A distinct, identifiable, multiple-peaked structure has been observed in Type I X-ray bursts from three sources. At energies below 6 keV, the light curves look like typical Type I bursts. At higher energies, the burst is double-peaked, with both the depth of the dip and the separation between the peaks increasing with energy. A light curve of the energy-integrated intensity shows no distinct double peak, suggesting that only a single energy release occurs. Blackbody fits to the evolving burst spectra yield changing radii and temperatures, inversely correlated, during the early part of the burst. The physical interpretation of these changes is uncertain. Burst decay spectra yield relatively constant radii with decreasing temperatures. It is proposed that Compton scattering may be responsible for the dips in the higher-energy light curves by shifting photons to lower energies.

Hoffman, J. A.↗

Lidar meteorology

Current and future lidar applications to meteorological studies are presented. In water vapor, temperature, and pressure measurement applications, differential absorption lidar (DIAL) techniques are used, employing a minimum of two wavelengths. The DIAL technique has proven particularly accurate in pressure measurements. For wind measurements, lidar investigations generally use the Doppler shifting of laser light backscattered from aerosols, and a pulsed low-power CO2 Doppler lidar is being developed for airborne platform applications. At visible to near-infrared wavelengths, spatial distribution of aerosol and clouds can be obtained from lidar, and this information can help determine such atmospheric parameters as mixed layer height and cloud height distributions. A Shuttle lidar facility, being developed for the end of the 1980's, will enable laser remote sensing techniques to be applied to studies of the lower atmosphere.

Browell, E. V.↗

Light-induced suppression of endogenous circadian amplitude in humans

A recent demonstration that the phase of the human circadian pacemaker could be inverted using an unconventional three-cycle stimulus has led to an investigation of whether critically timed exposure to a more moderate stimulus could drive that oscillator toward its singularity, a phaseless position at which the amplitude of circadian oscillation is zero. It is reported here that exposure of humans to fewer cycles of bright light, centered around the time at which the human circadian pacemaker is most sensitive to light-induced phase shifts, can markedly attenuate endogenous cicadian amplitude. In some cases this results in an apparent loss of rhythmicity, as expected to occur in the region of singularity.

Jewett, Megan↗

Influence of gravity on the circadian timing system

The circadian timing system (CTS) is responsible for daily temporal coordination of physiological and behavioral functions both internally and with the external environment. Experiments in altered gravitational environments have revealed changes in circadian rhythms of species ranging from fungi to primates. The altered gravitational environments examined included both the microgravity environment of spaceflight and hyperdynamic environments produced by centrifugation. Acute exposure to altered gravitational environments changed homeostatic parameters such as body temperature. These changes were time of day dependent. Exposure to gravitational alterations of relatively short duration produced changes in both the homeostatic level and the amplitude of circadian rhythms. Chronic exposure to a non-earth level of gravity resulted in changes in the period of the expressed rhythms as well as in the phase relationships between the rhythms and between the rhythms and the external environment. In addition, alterations in gravity appeared to act as a time cue for the CTS. Altered gravity also affected the sensitivity of the pacemaker to other aspects of the environment (i.e., light) and to shifts of time cues. Taken together, these studies lead to the conclusion that the CTS is indeed sensitive to gravity and its alterations. This finding has implications for both basic biology and space medicine.

Fuller, C. A.↗

Regulation of assimilate partitioning by daylength and spectral quality

The effects of daylength and spectral quality on assimilate partitioning and leaf carbohydrate content should be considered when conducting controlled environment experiments or comparing results between studies obtained under different lighting conditions. Changes in partitioning may indicate alterations to photoregulatory processes within the source leaf rather than disruptions in sink strength. Moreover, it may be possible to use photoregulatory responses of assimilate partitioning to probe mechanisms of growth and development involving translocation of carbon or adaptation to environmental factors such as elevated CO2. It may also be possible to steer assimilate partitioning for the benefit of controlled environment agriculture using energy-efficient manipulations such as daylength extensions with dim irradiances, end-of-day alterations in light quality, or shifting plants between different spectral qualities as a part of phasic control of growth and development. Note that high starch levels measured on a one-time basis provide little information, since it is the proportion of photosynthate stored as starch that is meaningful. Large differences in starch content can result from small changes in partitioning integrated over several days. Rate information is required.

Britz, Steve J.↗

Accuracy Study of a 2-Component Point Doppler Velocimeter (PDV)

A two-component Point Doppler Velocimeter (PDV) which has recently been developed is described, and a series of velocity measurements which have been obtained to quantify the accuracy of the PDV system are summarized. This PDV system uses molecular iodine vapor cells as frequency discriminating filters to determine the Doppler shift of laser light which is scattered off of seed particles in a flow. The majority of results which have been obtained to date are for the mean velocity of a rotating wheel, although preliminary data are described for fully-developed turbulent pipe flow. Accuracy of the present wheel velocity data is approximately +/- 1 % of full scale, while linearity of a single channel is on the order of +/- 0.5 % (i.e., +/- 0.6 m/sec and +/- 0.3 m/sec, out of 57 m/sec, respectively). The observed linearity of these results is on the order of the accuracy to which the speed of the rotating wheel has been set for individual data readings. The absolute accuracy of the rotating wheel data is shown to be consistent with the level of repeatability of the cell calibrations. The preliminary turbulent pipe flow data show consistent turbulence intensity values, and mean axial velocity profiles generally agree with pitot probe data. However, there is at present an offset error in the radial velocity which is on the order of 5-10 % of the mean axial velocity.

Kuhlman, John↗