Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Anisotropic elastoplastic response of double-porosity media

Here we present a continuum framework to simulate fluid flow through anisotropic elastoplastic media with double porosity. Two effective stress measures σ' and δ" emerge from the thermodynamic formulation, which are energy-conjugate to the elastic and plastic components of strain, respectively. Both effective stress measures can be expressed as a combination of the total Cauchy stress σ and the average pore pressure $\bar{p}$ in the two pore scales. In the effective stress for elasticity, $\bar{p}$ is scaled with a rank-2 Biot tensor, whereas the effective stress for plasticity follows the Terzaghi form in which $\bar{p}$ is scaled by the Kronecker delta. The Biot tensor and storage coefficients are derived as functions of elasticity parameters and porosities. A mixed finite element formulation is introduced to discretize the domain and solve initial boundary-value problems. A stabilization scheme is employed on equal-order interpolation for both displacement and pressure fields throughout the entire range of drainage responses. Numerical simulations reproduce the hydromechanical response of Opalinus shale in one-dimensional consolidation tests throughout the range of primary and secondary consolidation under different external loads. Numerical simulations of the consolidation of a rectangular domain subjected to a strip load demonstrate the efficacy of the proposed stabilization scheme, as well as illustrate the impacts of stress history, mass transfer, and different pore systems on the hydromechanical response.

42 ENGINEERING↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrically Engaged UnduLation (EEL) Marine Energy System

Current technologies at the forefront of instrumentation for ocean observation through acoustic mapping are powered by batteries that cannot achieve the lasting durations required for high-resolution measurements. Pyro-E has designed an Electrically Engaged unduLation (EEL) system capable of in situ energy harvest and deployment in sub-sea configurations. By extracting kinetic energy from the ocean, EEL proposes to provide power output ranging from 1 mW to 1,000 mW. Such a magnitude of power can sustain active instrumentation with onboard processing of data and over-the-horizon telemetry. Pyro-E and Oak Ridge National Laboratory have utilized software tools and powerful computing resources to develop a techno-economic design of the EEL capable of harvesting 5 W. The material response of the EEL under simulated hydromechanical loads is described through time-accurate predictions. All physical tests were conducted by Pyro-E to guide simulations at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER↗

Charge-exchange losses of beam ions in MAST Upgrade: experiments and modelling

Dedicated experiments were performed on MAST Upgrade to study beam-ion losses caused by charge exchange (CX) with edge neutrals. The fuelling was switched from the high-field side to the low-field side mid-discharge. Direct measurements suggest a strong increase in the neutral density around the plasma and a decrease in the beam-ion density, which is qualitatively explained by CX losses. Measurements by a resistive bolometer have suggested particle bombardment during neutral beam injection, providing a unique opportunity to separate CX from other loss mechanisms. To verify and quantify CX losses, the orbit-following code ASCOT, which accounts both for CX neutralization and reionization, was used to simulate beam-particle power loads on the bolometer. Simulations reproduce measured bolometer power loads during high-field-side fuelling, verifying CX losses of approximately 10% of the off-axis beam power. Toroidally symmetric simulations overestimate power loads on the bolometer during low-field-side fuelling, which is explained by toroidal asymmetry in the neutral density distribution, as is demonstrated by toroidally asymmetric simulations. Results suggest significantly higher CX losses during low-field-side fuelling, up to about 50% of off-axis beam power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Phase transformation path in Aluminum under ramp compression; simulation and experimental study

Abstract We present a framework based on non-equilibrium molecular dynamics (NEMD) to reproduce the phase transformation event of Aluminum under ramp compression loading. The simulated stress-density response, virtual x-ray diffraction patterns, and structure analysis are compared against the previously observed experimental laser-driven ramp compression in-situ x-ray diffraction data. The NEMD simulations show the solid–solid phase transitions are consistent to experimental observations with a close-packed face-centered cubic (fcc) (111), hexagonal close-packed (hcp) structure (002), and body-centered cubic bcc (110) planes remaining parallel. The atomic-level analysis of NEMD simulations identifiy the exact phase transformation pathway happening via Bain transformation while the previous in situ x-ray diffraction data did not provide sufficient information for deducing the exact phase transformation path.

36 MATERIALS SCIENCE↗

Community Geothermal: Borefield Design, Thermal Conductivity, and Subsurface Modeling Data - Chicago, IL

This dataset encompasses the development of a geothermal energy system for the West Woodlawn neighborhood in Chicago, Illinois. This project is part of a broader initiative to design and deploy geothermal heating and cooling systems at a community scale. The dataset includes thermal conductivity test results, calculations for borehole sizing based on the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) method, as well as simulated thermal loads based on actual energy usage from individual buildings. Also provided here are files used for numerical modeling via COMSOL Multiphysics to simulate borefield design and subsurface thermal behavior. Two manuscripts are attached, which outline the broad objectives of the project and a description of the numerical modeling methodology and results.

15 GEOTHERMAL ENERGY↗

Establishing a process-structure-property-performance framework for SLS additive manufacturing through integrated multiscale modeling

This study presents a comprehensive suite of high-fidelity computational models that integrate multiscale and multiphysics simulations to capture the full Selective Laser Sintering (SLS) additive manufacturing process—from initial melting and solidification to mechanical response under external loads. Process simulations are linked with mechanical analysis through Representative Volume Elements (RVEs), establishing a process-structure–property-performance framework. The interaction between laser light and polyamide 12 (PA12) powder is modeled, accounting for laser characteristics and the optical, thermal, and geometrical properties of the powder. The heat source is incorporated into a heat transfer model, coupled with crystallization kinetics and densification models to predict material density and crystallinity. The porosity distribution from the densification model and crystallinity interpolated from experimental data are used to construct the RVEs. A multi-mechanism constitutive model is then calibrated using mechanical tests to predict the stress–strain response. Simulation results show good agreement with experimental data in terms of porosity, crystallinity, and mechanical performance when sufficient laser power (62 W or higher) is used. This research supports the inverse design of 3D-printed structures by introducing a high-fidelity framework that combines multiscale and multiphysics modeling with experimental calibration for predictive and performance-driven additive manufacturing.

SLS↗

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

In-Silico Design of Next Generation Cellulose-Derived Packaging Materials (CRADA Final Report)

Developing sustainable solutions for single-use packaging is an important objective to combat the environmental crisis of plastics pollution. Most embodiments of cellulose-based packaging materials, including CellophaneTM, are completely biodegradable in both terrestrial and marine environments. However, petroleum-derived alternatives offer some performance advantages for metrics such as moisture barriers and mechanical properties. This project leverages molecular dynamics simulation to investigate how molecular modifications to cellulose-based polymer assemblies impact their material properties. An important performance criterion for the modified materials was to retain biodegradability; thus, modifications by naturally occurring, biodegradable additives were the focus of this study. Specifically, we developed models with xylan and lignin of varying monomeric compositions into the cellulose matrix. The mechanical properties were investigated by performing stress-strain simulations, and the water barrier and hydrophobicity were investigated by simulating the water contact angle. Our findings indicate that the incorporation of xylan into the cellulose matrix tends to increase the mechanical properties with an optimal loading of ~27 wt%. We also predict that orienting the nanoscale directionality of the xylan chains such that they are perpendicular to the cellulose fibrils will dramatically increase mechanical strength. In contrast, the incorporation of lignin tends to weaken the composite at all loadings investigated. Simulations of water contact angle predicted that coating polymers on the surface of the cellulose assembly creates a more hydrophobic surface than incorporating them throughout the matrix. Of the coatings investigated, lignin resulted in the most hydrophobic surface, followed by pectin and keratin, which both imparted modest increases in hydrophobicity. Future experimental work done by Futamura will focus on designing material prototypes to capitalize on the predictions of performance enhancement obtained from molecular modeling. While substantial progress was made by the simulations performed in this project, there still exists a vast parameter space that we were unable to investigate, including branching, functional group decoration, and degree of polymerization of polymer additives. However, the methods developed in this initial investigation will facilitate more rapid evaluation of the impact of molecular characteristics on the performance of biopolymer composite materials and thereby accelerate future materials discovery efforts in this area.

36 MATERIALS SCIENCE↗

Crystallographic orientation and spatially resolved damage in a dispersion-hardened Al alloy

The in-situ neutron diffraction technique, in combination with both the full-field crystal elasto-viscoplastic finite element model and microstructural characterization, was used to study the deformation-induced damage anisotropy in a commercial Al alloy, subjected to uniaxial tensile and cyclic loading. The simulations capture well the crystallographic-orientation-dependent lattice strain behavior. The hard grains, e.g. those orientated with the <111> and <422> orientations parallel with the uniaxial loading direction (LD), feature large Taylor factors and seem more prone to form damage-related band structures. Their effective elastic moduli decrease with the accumulation of damage, which are different from the soft grains orientated with the <200> orientation along the LD. Correlation between the distribution of voids and that of the residual lattice strain developed after failure may exist. The maximum tensile type residual lattice strain observed after failure may be resulted from the band structure formed in the hardest <111> grains. It was revealed that the band structure triggered by the hard particles could be one of sources of damage. In addition, while the specimen was obviously damaged, a fast stress relief was evidenced after unloading from the tension, especially at the beginning of unloading. Our present investigations provide a novel method for exploring the damage mechanisms of polycrystalline materials during plastic deformation.

36 MATERIALS SCIENCE↗

Did the GPU obfuscate the load imbalance in my MPI simulation?

The current proliferation of GPU-based HPC systems necessitates a method for assessing the performance of simulations on heterogeneous machines. The addition of GPUs to a system adds multiple hierarchical levels of parallelism to the node architecture. In this paper, we demonstrate that the traditional load imbalance metric is insufficient for capturing the load imbalance on GPU-based machines, since it treats the GPU as a monolithic entity and ignores the internal parallelism. We propose a new hierarchical metric that improves the correlation of measured performance and application workload by up to 20.61%. Using our metric for determining application load instead of the traditional metric as the input for the load balancing algorithm reduces the residual load imbalance by up to 4× in our application.

Eberius, David↗

In Situ Wind and Turbulence Measurements in a Field of Full-Size Parabolic Trough Solar Collectors

Concentrated Solar Power (CSP) is a promising method for using Solar power for electricity generation with thermal energy storage. One of the primary drivers of structural design costs of CSP collector structures is wind loading. To date, the design of these structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights on structural dynamic response, and generating a first-of-a-kind, comprehensive, high-resolution wind-loading dataset available for validating simulations of wind loading on collector structures. The measurements at NSO consist of Sonic anemometers on masts at different heights to characterize the incoming flow and conditions within and above the trough field, in combination with a Doppler Lidar scanning the horizontal plane above the troughs. The wind measurements at NSO have been continuously operating since October 2021 and provide a year-long dataset characterizing wind and turbulence conditions. The structural load measurements start in November 2022 and will complement the wind measurements. In this poster, we present first results of the wind measurement campaign by highlighting days with different atmospheric flow conditions. We identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. The highest loads are expected when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest loads and block the subsequent rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales change. These affected conditions produce unique load cases on the structures that will be captured by the load measurements. If the wind blows along the trough rows, wind and turbulence conditions are less influenced by the troughs.

atmospheric turbulence↗

In Situ Wind and Turbulence Measurements in a Field of Full-Size Parabolic Trough Collectors

Concentrated Solar Power (CSP) is a promising method for using Solar power for electricity generation with thermal energy storage. One of the primary drivers of structural design costs of CSP collector structures is wind loading. To date, the design of these structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights on structural dynamic response, and generating a first-of-a-kind, comprehensive, high-resolution wind-loading dataset available for validating simulations of wind loading on collector structures. The measurements at NSO consist of Sonic anemometers on masts at different heights to characterize the incoming flow and conditions within and above the trough field, in combination with a Doppler Lidar scanning the horizontal plane above the troughs. The wind measurements at NSO have been continuously operating since October 2021 and provide a year-long dataset characterizing wind and turbulence conditions. The structural load measurements start in November 2022 and will complement the wind measurements. In this poster, we present first results of the wind measurement campaign by highlighting days with different atmospheric flow conditions. We identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. The highest loads are expected when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest loads and block the subsequent rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales change. These affected conditions produce unique load cases on the structures that will be captured by the load measurements. If the wind blows along the trough rows, wind and turbulence conditions are less influenced by the troughs.

concentrated solar power↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗