Search NASA⌕ Search

SEARCH · Search NASA

Results for “long screened wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Countermeasure for Radiation Protection and Repair

Exposure to ionizing radiation during long-duration space missions is expected to cause short-term illness and increase long-term risk of cancer for astronauts. Radiation-induced free radicals overload the antioxidant defense mechanisms and lead to cellular damage at the membrane, enzyme, and chromosome levels. A large number of radioprotective agents were screened, but most had significant side effects. But there is increasing evidence that significant radioprotective benefit is achieved by increasing the dietary intake of foods with high antioxidant potential. Early plant-growing systems for space missions will be limited in both size and volume to minimize power and mass requirements. These systems will be well suited to producing plants containing high concentrations of bioprotective antioxidants. This project explored whether the production of bioprotective compounds could be increased by altering the lighting system, without increasing the space or power requirements for production, and evaluated the effects of environmental conditions (light quantity, light quality, and carbon dioxide [CO2] concentration) on the production of bioprotective compounds in lettuce, which provide a biological countermeasure for radiation exposure. The specific deliverables were to develop a database of bioprotectant compounds in plants that are suitable for use on longduration space missions, develop protocols for maintaining and increasing bioprotectant production under light emitting diodes (LEDs), recommend lighting requirements to produce dietary countermeasures of radiation, and publish results in the Journal of the American Society for Horticultural Science.

Source record↗

BeppoSAX Observation of NGC 7582: Constraints on the X-Ray Absorber

This paper presents a BeppoSAX observation of NGC 7582 made during 1998 November and an optical spectrum taken in 1998 October. The new X-ray data reveal a previously unknown hard X-ray component in NGC 7582, peaking close to 20 keV. Rapid variability is observed with correlated changes in the 5-10 and 13-60 keV bands indicating that a single continuum component, produced by the active nucleus, provides the, dominant flux across both bands. Comparison between RXTE and BeppoSAX data reveals changes in the 2 - 10 keV flux on timescales of months. Changes in the nuclear X-ray flux appear unrelated to the gradual decline in optical flux noted since the high-state in 1998 July. The 0.5 - 2 keV flux of NGC 7582 is not significantly variable within the BeppoSAX observation, but has brightened by a factor of approximately 2 since the ASCA observation of 1994. While there is some concern about contamination from spatially-unresolved sources, the long-term variability in soft X-ray flux seems most likely associated with the nucleus or an event within the host galaxy of NGC 7582. The 2 - 100 keV spectrum is well fit by a powerlaw of photon index Gamma = 1.95(sup +0.09, sub -0.18) steeper by Delta.Gamma approximately equal 0.40 than the index during the 1994 ASCA observation. The X-ray continuum is attenuated by a thick absorber of N(H) approximately 1.6 x10(exp 24)/sq cm covering approximately 60(sup +10%, sub -14%) of the nucleus plus a screen with N(sub H) approximately 1.4 x 10(exp 23)/ sq cm covering the entire nucleus. Comparison of the BeppoSAX and ASCA spectra shows an increase in the full screen by Delta.N(sub H) approximately equal 7 x 10(exp 22)/sq cm since 1994, confirming the absorption variability found by Xue et al. The increase in soft X-ray flux between 1994 and 1998 is consistent with the appearance of holes in the full screen allowing approximately < 1% of the nuclear flux to escape, and producing some clear lines-of-sight to the broad-line-region. The data are also consistent with the scenario suggested by Aretxaga et al, of the radiative onset of a type IIn supernova causing the observed optical change in NGC 7582.

Turner, T. J.↗

Wilson Corners Solid Waste Management Unit (SWMU) 001: 2021 Annual Long-Term Monitoring Report, Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2021 at Wilson Corners, Solid Waste Management Unit (SWMU) 001, at Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures (IM). Annual LTM of the groundwater is also being conducted at the site. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code (F.A.C.). The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. The sampling of these wells in 2020 was replaced with the direct push technology (DPT) investigations completed in October 2020 and April 2021. This DPT groundwater data was presented in an Advance Data Package (ADP) in September 2021 and discussed in the Implementation Work Plan (IWP) dated November 2021 for installation of an air sparge (AS) system. Based on results from groundwater sampling activities performed during the previous reporting period, including the 2020 and 2021 DPT groundwater sampling, it was determined that the LTM sampling plan was no longer meeting the goal of LTM because delineation was not verified. The 2021 LTM sampling plan was modified to include the sampling of monitoring wells located around the perimeter of the low concentration plume (LCP); the area with concentrations of contaminants of concern [COCs] greater than Groundwater Cleanup Target Levels [GCTLs]), and sampling of 10 monitoring wells proposed for installation (April 2021 KSC Remediation Team (KSCRT) Meeting, Decision 2104-D32). The modified LTM plan received team consensus at the September 2021 KSCRT Meeting (Decision Number 2109-D03), and sampling of the existing monitoring wells was completed in December 2021. The proposed monitoring wells are planned for installation in late 2022, concurrent with ongoing IM construction activities. December 2021 LTM data was presented at the May 2022 KSCRT Meeting, and activities are summarized in this report. The activities presented in this report include the December 2021 groundwater gauging of 42 monitoring wells and sampling of 44 monitoring wells. During the December 2021 event, the low flow sampling method was used, and samples were analyzed for a select list of volatile organic compounds (VOCs), including 1,1,2-trichloro-1,2,2-trifluoroethane (Freon 113). The following conclusions can be made based on the 2021 LTM results: - In December 2021, groundwater flow for the site was generally to the west at all intervals. This is generally consistent with historical observations at the site, with the exception of a southwest and southeast flow component observed at 34 to 48 feet below land surface (bls). - The vertical extent of VOCs was historically delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells, WILC-MW0078 (screened 65 to 70 feet bls) and WILC-MW0130 (screened 56 to 66 feet bls) that were sampled during the 2021 LTM indicate that groundwater vinyl chloride (VC) concentrations in both wells were greater than the GCTL. The Remediation Team has previously agreed to delay deeper DPT investigations in this area to prevent the creation of additional pathways for vertical migration. - The LCP continues to extend both horizontally, predominantly to the west, and vertically beyond the current monitoring well network, with some retraction observed to the southeast. Evaluation of this data combined with data from the 2020 and 2021 DPT sampling event indicate that the LCP encompasses an estimated 20.7 acres based on an expanded sampling area, as compared to the 2020 LCP footprint of 17.0 acres. - Freon 113 was not detected above GCTLs during the 2021 LTM event. Based on groundwater sampling activities performed in 2021, including April 2021 DPT groundwater sampling, the following recommendations are provided: - Perform the next LTM sampling event, targeted to occur in 2023, concurrently with the IM baseline sampling prior to AS system installation; - Include sampling from nine monitoring wells that are planned to be installed in late 2022, concurrent with upcoming IM construction activities. Installation of one deep vertical well, screened 70 to 80 feet bls, will be delayed to prevent the creation of an additional pathway for vertical migration; - Continue to sample under the modified annual LTM plan as presented in Table 4-1 concurrently with IM baseline sampling; and - Once the AS system install and start-up is complete, select monitoring wells from the LTM program will transition into the performance monitoring plan, and LTM will be temporarily discontinued. Performance monitoring will be performed quarterly, and the monitoring well network will be evaluated following the first performance monitoring sampling event.

long-term monitoring (LTM)↗

Cryogenic Quenching Process for Electronic Part Screening

The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

Sheldon, Douglas J.↗

High-throughput screening of 2D materials identifies p-type monolayer WS2 as potential ultra-high mobility semiconductor

Abstract 2D semiconductors offer a promising pathway to replace silicon in next-generation electronics. Among their many advantages, 2D materials possess atomically-sharp surfaces and enable scaling the channel thickness down to the monolayer limit. However, these materials exhibit comparatively lower charge carrier mobility and higher contact resistance than 3D semiconductors, making it challenging to realize high-performance devices at scale. In this work, we search for high-mobility 2D materials by combining a high-throughput screening strategy with state-of-the-art calculations based on the ab initio Boltzmann transport equation. Our analysis singles out a known transition metal dichalcogenide, monolayer WS 2 , as the most promising 2D semiconductor, with the potential to reach ultra-high room-temperature hole mobilities in excess of 1300 cm 2 /Vs should Ohmic contacts and low defect densities be achieved. Our work also highlights the importance of performing full-blown ab initio transport calculations to achieve predictive accuracy, including spin–orbital couplings, quasiparticle corrections, dipole and quadrupole long-range electron–phonon interactions, as well as scattering by point defects and extended defects.

Chemistry↗

Risk of Performance Decrements and Adverse Health Outcomes Resulting from Sleep Loss, Circadian Desynchronization, and Work Overload

Sleep loss, circadian desynchronization, and work overload occur to some extent for ground and flight crews, prior to and during spaceflight missions. Ground evidence indicates that such risk factors may lead to performance decrements and adverse health outcomes, which could potentially compromise mission objectives. Efforts are needed to identify the environmental and mission conditions that interfere with sleep and circadian alignment, as well as individual differences in vulnerability and resiliency to sleep loss and circadian desynchronization. Specifically, this report highlights a collection of new evidence to better characterize the risk and reveals new gaps in this risk as follows: Sleep loss is apparent during spaceflight. Astronauts consistently average less sleep during spaceflight relative to on the ground. The causes of this sleep loss remain unknown, however ground-based evidence suggests that the sleep duration of astronauts is likely to lead to performance impairment and short and long-term health consequences. Further research is needed in this area in order to develop screening tools to assess individual astronaut sleep need in order to quantify the magnitude of sleep loss during spaceflight; current and planned efforts in BHP's research portfolio address this need. In addition, it is still unclear whether the conditions of spaceflight environment lead to sleep loss or whether other factors, such as work overload lead to the reduced sleep duration. Future data mining efforts and continued data collection on the ISS will help to further characterize factors contributing to sleep loss. Sleep inertia has not been evaluated during spaceflight. Ground-based studies confirm that it takes two to four hours to achieve optimal performance after waking from a sleep episode. Sleep inertia has been associated with increased accidents and reduced performance in operational environments. Sleep inertia poses considerable risk during spaceflight when emergency situations necessitate that crewmembers wake from sleep and make quick decisions. A recently completed BHP investigation assesses the effects of sleep inertia upon abrupt awakening, with and without hypnotics currently used in spaceflight; results from this investigation will help to inform strategies relative to sleep inertia effects on performance. Circadian desynchrony has been observed during spaceflight. Circadian desynchrony during spaceflight develops due to schedule constraints requiring non-24 operations or 'slam-shifts' and due to insufficient or mis-timed light exposure. In addition, circadian misalignment has been associated with reduced sleep duration and increased medication use. In ground-based studies, circadian desynchrony has been associated with significant performance impairment and increased risk of accidents when operations coincide with the circadian nadir. There is a great deal of information available on how to manage circadian misalignment, however, there are currently no easily collected biomarkers that can be used during spaceflight to determine circadian phase. Current research efforts are addressing this gap. Work overload has been documented during current spaceflight operations. NASA has established work hour guidelines that limit shift duration, however, schedule creep, where duty requirements necessitate working beyond scheduled work hours, has been reported. This observation warrants the documentation of actual work hours in order to improve planning and in order to ensure that astronauts receive adequate down time. In addition to concerns about work overload, ground based evidence suggests that work underload may be a concern during deep space missions, where torpor may develop and physically demanding workload will be exchanged for monitoring of autonomous systems. Given that increased automation is anticipated for exploration vehicles, fatigue effects in the context of such systems needs to be further understood. Performance metrics are needed to evaluate fitness-for-duty during spaceflight. Although ground-based evidence supports the notion that sleep loss, circadian desynchronization and work overload lead to performance impairment, inconsistency in the measures used to evaluate performance during spaceflight make it difficult to evaluate the magnitude of performance impairment during spaceflight. Work is underway to standardize measures of performance evaluation during spaceflight. Once established, such performance indicators need to be correlated with operational performance. Individual differences in sleep need and circadian preference, phase shifting ability and period have been documented in ground-based studies. Individual differences in response to sleep loss and circadian misalignment have also been documented and are presumed to be associated with genetic polymorphisms. No studies have systematically reported individual differences in sleep or circadian-related outcomes during spaceflight. More work is needed in this area in order to identify genetic or phenotypic biomarkers that predict resilience or vulnerability to sleep loss in order to personalize countermeasure strategies and mitigate performance impairment during spaceflight. Two laboratory and field investigations specific to this topic are currently ongoing; additional efforts, including an effort to mine existing biological data from spaceflight relative to sleep and circadian outcomes, are planned. Sex differences in sleep need and circadian period and phase have been reported in ground-based studies. The impact of these sex differences on performance is unclear. Sex differences in sleep need and circadian rhythms have not been systematically studied during spaceflight, presumably due to the small number of women that have flown in space. More research is needed in this area to evaluate whether any of the observed sex differences in physiology lead to altered performance in spaceflight and on the ground.

Flynn-Evans, Erin↗

High Field Side Launch of RF Waves: A New Approach to Reactor Actuators

Launching radio frequency (RF) waves from the high field side (HFS) of a tokamak offers significant advantages over low field side (LFS) launch with respect to both wave physics and plasma material interactions (PMI). For lower hybrid (LH) waves, the higher magnetic field opens the window between wave accessibility and the condition for strong electron Landau damping, allowing LH waves from the HFS to penetrate into the core of a burning plasma, while waves launched from the LFS are restricted to the periphery of the plasma. The lower of waves absorbed at higher yields a higher current drive efficiency as well. In the ion cyclotron range of frequencies (ICRF), HFS launch allows for direct access to the mode conversion layer where mode converted waves absorb strongly on thermal electrons and ions, thus avoiding the generation of energetic minority ion tails. The absence of turbulent heat and particle fluxes on the HFS, particularly in double null configuration, makes it the ideal location to minimize PMI damage to the antenna structure. The quiescent SOL also eliminates the need to couple LH waves across a long distance to the separatrix, as the antenna can be located close to plasma without risking damage to the structure. Improved impurity screening on the HFS will help eliminate the long-standing issues of high Z impurity accumulation with ICRF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pilot Study on the Investigation of Tear Fluid Biomarkers as an Indicator of Ocular, Neurological, and Immunological Health in Astronauts

The purpose of this pilot study is to investigate the collection, preparation, and analysis of tear biomarkers as a means of assessing ocular, neurological, and immunological health. At present, no published data exists on the cytokine profiles of tears from astronauts exposed to long periods of microgravity and space irradiations. In addition, no published data exist on cytokine (biomarker) profiles of tears that have been collected from irradiated non-human biological systems (primates and other animal models). A goal for the proposed pilot study is to discover novel tear biomarkers which can help inform researchers, clinicians, epidemiologist and healthcare providers about the health status of a living biological system, as well as informing them when a disease state is triggered. This would be done via analysis of the onset of expression of pro-inflammatory cytokines, leading up to the full progression of a disease (i.e. cancer, loss of vision, radiation-induced oxidative stress, cardiovascular disorders, fibrosis in major organs, bone loss). Another goal of this pilot study is to investigate the state of disease against proposed medical countermeasures, in order to determine whether the countermeasures are efficacious in preventing or mitigating these injuries. An example of an up and coming tear biomarker technology, Ascendant Dx, a clinical stage diagnostic company, is developing a screening test to detect breast cancer using proteins from tears. The team utilized Liquid Chromatography -Mass Spectrometry with Mass analysis (LC MS/MS) as a discovery platform followed by validation with ELISA to come up with a panel of protein biomarkers that can differentiate breast cancer samples from control ("cancer free") samples with results far surpassing the results of imaging techniques in use today. Continued research into additional proteins is underway to increase the sensitivity and specificity of the test and development efforts are on the way to transfer the test onto a fast, accurate and inexpensive point of care platform. In conclusion, the expected results from this proposed pilot study are to: a) establish an SOP for retrieving/storing/transporting tear fluid samples from multicentre sites b) establish a normal range for relevant biomarkers in tears; and c) establish a database (biobank) of tears of space naïve versus veteran astronauts, to establish a personal baseline for long-term ocular health monitoring

Morton, Stephen↗

Defects in Highly Anisotropic Transition-Metal Dichalcogenide PdSe 2

The atomic and electronic structures of the pristine PdSe 2 as well as various intrinsic vacancy defects in PdSe 2 are studied comprehensively by combining scanning tunneling microscopy, spectroscopy and density functional theory calculations. Other than the topmost Se atoms, sublayer Pd atoms, the intrinsic Pd and Se vacancy-defects are identified. Both V Se and V Pd defects induce defect states near Fermi level. As a result, the vacancy defects can be negatively charged by tip gating effect. At negative sample bias, the screened Coulomb interaction between STM tip and the charged vacancies creates disk-like protrusion around V Pd and crater-like features around V Se . The magnification effect of the long-range charge localization at the charged defect site makes sublayer defects as deep as 1nm visible even in STM images. In conclusion, this result proves that by gating the probe, scanning probe microscopy can be used as an easy tool for characterizing sublayer defects in a nondestructive way.

36 MATERIALS SCIENCE↗

Strategies Toward Lunar Dust Adhesion Mitigation

Recently, the NASA Space Technology Mission Directorate solicited feedback to prioritize shortfalls, which were defined as technology areas needed to enable future exploration missions. Lunar dust mitigation emerged as a critical area and is cross-cutting with many of the highest ranked shortfalls with passive dust mitigation technologies being directly ranked in the top 50. Hazards associated with lunar dust are ubiquitous across all aspects of long duration lunar surface missions, whether crewed or robotic, due to the abrasive, electrostatically charged, and chemically reactive properties of lunar dust. Compounding the issue, lunar dust moves across the lunar surface due to levitation, twilight craters, and plume-surface interactions, which can result in particle velocities exceeding 1 km/h. To address lunar dust challenges, NASA is developing active and passive adhesion mitigation technologies to address specific mission needs, including electrodynamic dust screens, piezoelectric materials, biomimetic engineered surfaces, among many others. Additionally, abrasion-resistant materials are being evaluated for applications for use near landing sites and in surface manipulation and excavation equipment. These approaches, as well as test methodologies both in the laboratory and on the lunar surface to evaluate technology efficacy, will be described.

Dust Mitigation↗

Understanding and design of interstitial oxygen conductors

Highly efficient oxygen-active materials that react with, absorb, and transport oxygen is essential for fuel cells, electrolyzers and related applications. While vacancy-mediated oxygen-ion conductors have long been the focus of research, they are limited by high migration barriers at intermediate temperatures (400–600 °C), which hinder their practical applications. In contrast, interstitial oxygen conductors exhibit significantly lower migration barriers enabling higher ionic conductivity at lower temperatures. This review systematically examines both well-established and recently identified families of interstitial oxygen-ion conductors, focusing on how their unique structural motifs such as corner-sharing polyhedral frameworks, isolated polyhedral, and cage-like architectures, facilitate low migration barriers through interstitial and/or interstitialcy diffusion mechanisms. A central discussion of this review focuses on the evolution of design strategies, from targeted donor doping, element screening, to physical-intuition descriptor material screening and machine learning approach, which leverage computational tools to explore vast chemical spaces in search for new interstitial conductors. The success of these strategies demonstrates that a significant, largely unexplored space remains for discovering high-performing interstitial oxygen conductors. Crucial features enabling high-performance interstitial oxygen diffusion include the availability of electrons for oxygen reduction and sufficient structural flexibility with accessible volume for interstitial accommodation and migration. This review concludes with a forward-looking perspective, proposing a knowledge-driven methodology that integrates current understanding with data-centric approaches to identify promising interstitial oxygen conductors outside traditional search paradigms. These approaches are expected to significantly accelerate the development of high-performance interstitial oxygen conductors for a variety of oxygen-active applications, ultimately paving the way for more efficient and sustainable energy technologies.

Interstitial oxygen conductors↗

Risk of Cardiac Rhythm Problems During Spaceflight

NASA has concerns regarding the incidence and clinical significance of cardiac arrhythmias that could occur during long-term exposure to the spaceflight environment, such as on the International Space Station (ISS) or during a prolonged (e.g., up to 3 years) sojourn to Mars or on the Moon. There have been some anecdotal reports and a few documented cases of cardiac arrhythmias in space, including one documented episode of non-sustained ventricular tachycardia. The potential catastrophic nature of a sudden cardiac death in the remote space environment has led to concerns from the early days of the space program that spaceflight might be arrhythmogenic. Indeed, there are known and well-defined changes in the cardiovascular system with spaceflight: a) plasma volume is reduced, b) left ventricular mass is decreased, and c) the autonomic nervous system adapts to the weightless environment. Combined, these physiologic adaptations suggest that changes in cardiac structure and neuro-humoral environment during spaceflight could alter electrical conduction, although the evidence supporting this contention consists mostly of minor changes in QT interval (the time between the start of the Q wave and the end of the T wave on an electrocardiogram tracing) in a small number of astronauts after long-duration spaceflight. Concurrent with efforts by NASA Medical Operations to refine and improve screening techniques relevant to arrhythmias and cardiovascular disease, as NASA enters the era of exploration-class missions it will be critical to determine with the highest degree of certainty whether spaceflight by itself alters cardiac structure and function sufficiently to increase the risk of arrhythmias.

Lee, Stuart M. C.↗

Distribution Feeder Characteristics and Their Resiliency to Natural Hazards

This paper introduces a method and approach for initially screening actions to improve the reliability of distribution systems exposed to three natural hazards (wildlife, weather, and vegetation). The method is well-suited to needs and capabilities of smaller utilities because it relies on readily available information and does not depend on simulations involving detailed engineering models. The method involves first aggregating feeders into like types and then correlating them, separately by hazard, to standard measures of reliability, namely, System Average Interruption Frequency Index (SAIFI) and System Average Interruption Duration Index (SAIDI), and the individual constituents of these measures. The correlations provide both new insights into the efficacy of accepted reliability management practices while and re-confirm long-understood, accepted practices. Importantly, the method does not seek to replace the need for detailed engineering analysis. Instead, in view of the significant costs involved in conducting these more involved analyses, the method is intended to help smaller utilities prioritize their more limited resources to maximize the efficacy of actions they take to improve reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Further applications of a Figure-of-Merit in space missions

A redesigned figure-of-merit (FoM) approach is described with respect to its applications in projects that employ in situ resource utilization (ISRU) and advanced modular engines. The FoM considers long-term effects, reliability of hardware, and risks inherent to new technologies, as well as significant design parameters. A spreadsheet is utilized to describe the FoM by means of key mission characteristics and combinations of the characteristic inputs in terms of precise governing equations. Results of the FoMs for historical and Mars Sample Return (MSR) missions are given for the conventional mission as well as an ISRU mission for the MSR. A detailed description of the most effective Mars mission is presented, showing how different factors affect the FoM. The results demonstrate that the FoM gives quantitative results based on overall mission design, allowing intercomparisons of similar missions. The FoM can be used as a screening parameter by modifying aspects of the mission by means of the R-factor.

Preiss, Bruce↗

Enhanced Configurational Sampling Approaches to Alchemical Ligand Binding Free Energy Simulations: Current Status and Challenges

In this study, ligand binding free energy simulations (LB-FES) have been routine tasks in modern drug discovery campaign. A long-standing challenge for LB-FES is the difficulty in adequately sampling nontrivial environmental reorganizations in response to ligand binding. Therefore, various enhanced configurational sampling (ECS) approaches were devised to speed up fluctuations of relevant slow degrees of freedom (SDOF) and ensure simulation convergence. However, in contrast to the achievements in parametrization, software performance, and workflow automation, efficient ECS methodology suitable for high throughput screening remains in an early stage of development. Here, a review of ECS developments with LB-FES is presented, revisiting current approaches and underlining the major technical pitfalls and challenges. This Perspective focuses on alchemical LB-FES on account of their predominant role in high throughput drug screening as well as the established partnership with ECS. The critical aspects of designing ECS approaches, from both theoretical and applied perspectives, are described. This work is intended to provide a contemporary review of the scientific, technical, and practical issues associated with the accelerating convergence of alchemical LBFES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

The Role of Circulating Tumor Cells in Breast Cancer and Implications for Radiation Treatment Decisions

Tumor biomarkers are used routinely in oncology to assign risk categorization, screen and assist in diagnosis of malignancy, allow for prognostication and prediction of outcomes and treatment response, and allow for monitoring of patients after treatment completion. Although tissue-based biomarkers have a long history of use, the emergence of liquid-based biomarkers, including circulating tumor cells (CTCs), may soon revolutionize the management of patients with cancer. Here, we review the discovery of CTCs and their role as prognostic and predictive biomarkers, with an emphasis on breast cancer. We discuss the platforms for CTC enumeration and focus on studies using the only US Food and Drug Administration–approved platform for CTC enumeration (CellSearch). In addition, we examine the role of CTCs in women with metastatic, inflammatory, and nonmetastatic breast cancer, as well as the clinical evidence for their use as a surrogate for radiation treatment response as well as surveillance after treatment. Finally, we conclude by investigating ongoing clinical studies assessing CTCs as radiation response predictors and discuss unanswered questions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗