Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

Closed Loop Testing of Microphonics Algorithms Using a Cavity Emulator

An analog crystal filter based cavity emulator is modified with reverse biased varactor diodes to provide a tuning range of around 160 Hz. The piezo drive voltage of the resonance controller is used to detune the cavity through the bias voltage. A signal conditioning and summing circuit allows the introduction of microphonics disturbance from a signal source or using real microphonics data from cavity testing. This setup is used in closed loop with a cavity controller and resonance controller to study the effectiveness of resonance control algorithms suitable for superconducting cavities.

43 PARTICLE ACCELERATORS↗

Hanford Tank Farms Waste Certification Flow Loop Test Plan

A future requirement of Hanford Tank Farm operations will involve transfer of wastes from double shell tanks to the Waste Treatment Plant. As the U.S. Department of Energy contractor for Tank Farm Operations, Washington River Protection Solutions anticipates the need to certify that waste transfers comply with contractual requirements. This test plan describes the approach for evaluating several instruments that have potential to detect the onset of flow stratification and critical suspension velocity. The testing will be conducted in an existing pipe loop in Pacific Northwest National Laboratory’s facility that is being modified to accommodate the testing of instruments over a range of simulated waste properties and flow conditions. The testing phases, test matrix and types of simulants needed and the range of testing conditions required to evaluate the instruments are described

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Controller-Hardware-in-the-Loop Test Bed for Fast-Switching SiC-Based 50-kW PV Inverter

The recent advent of wideband gap power semiconductor devices will lay the path to the future power converters. These devices provide the advantage of high switching speed and lower losses. The high cost and high switching speeds of these devices provide a challenge in the development and validation of the fast switching inverter controls with accuracy of that of a hardware setup. In this paper an FPGA real-time simulator-based controller-hardware-in-the-loop (CHIL) testbed is used to verify the low-level and advanced inverter controls fast switching wide bandgap-based string photovoltaic inverter. The paper also includes development of the CHIL testbed, which is run at a time-step of 500 ns in order to implement 20 kHz switching frequency. The developed CHIL testbed is validated through experimental results from a three-phase, 50 kW, 480 VLLrms SiC devices based inverter.

14 SOLAR ENERGY↗

Interinstitutional Study of the New EURO-GANEX Process Resistance by Gamma Irradiation Test Loops

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. However, EURO-GANEX also has various drawbacks that are being addressed. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolysis resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate together the organic and aqueous phases, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analysed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or tracers extraction, and HPLC-MS to quantify the degradation and evaluate the degradation compounds. Additionally, in spite of some differences between the three-irradiation facilities, this inter-institutional study shows that they are three comparative tools, which provide results on the stability towards radiolysis of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Power Hardware-in-the-Loop Testing of Multiple Photovoltaic Inverters' Volt-Var Control with Real-Time Grid Model

Traditional testing methods fall short in evaluating interactions between multiple smart inverters providing advanced grid support functions due to the fact that such interactions largely depend on their placements on the electric distribution systems with impedances between them. Even though significant concerns have been raised by the utilities on the effects of such interactions, little effort has been made to evaluate them. In this paper, power hardware-in-the-loop (PHIL) based testing was utilized to evaluate autonomous volt-var operations of multiple smart photovoltaic (PV) inverters connected to a simple distribution feeder model. The results provided in this paper show that depending on volt-var control (VVC) parameters and grid parameters, interaction between inverters and between the inverter and the grid is possible in some extreme cases with very high VVC slopes, fast response times and large VVC response delays.

14 SOLAR ENERGY↗

Modeling the Transient Reactor Test Loop in TRACE for PWR Critical Heat Flux Benchmarking

Understanding transient critical heat flux (CHF) resulting from a Reactivity Insertion Accident (RIA) in nuclear systems is an extremely undeveloped field. Though many experiments have been done for CHF, remarkably few have been done for rods at PWR operating temperature and pressure (300 deg. C, 2200 psia) with a short time constant ramp in power. This leads to many concerns regarding understanding how RIA scenarios develop and evolve in commercial nuclear reactors. With a limited understanding of the phenomenology governing transient CHF, there is little hope in being able to accurately model these scenarios using today's thermal hydraulic codes. The Accident Tolerant Fuels (ATF) Program established by the Department of Energy (DOE) is seeking out new fuel and cladding systems that can be used to reduce the probability and consequences of severe accidents. To better understand this phenomenon, the DOE is restarting the Transient Reactor Test (TREAT) Facility at the Idaho National Laboratory (INL). TREAT will be able to provide representative neutronic boundary conditions for testing coupled thermal hydraulics on the Transient Water Environment Recirculating Loop (TWERL) to study transient CHF with the best representation possible. To support this task, Oregon State University (OSU) is designing and building a representative flow loop that will be able to mimic the conditions of TWERL (sans the neutronic boundary conditions) to create a benchmark study for existing lumped parameter thermal-hydraulic codes such as RELAP5 and TRACE. This flow loop, the Transient Reactor Test Facility (TRTL), will support the ATF program by providing much needed NQA-1 data for transient CHF at operating temperature and pressure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Covariant calculation of a two-loop test of nonrelativistic QCD factorization

In this work we test the nonrelativistic QCD factorization conjecture for inclusive quarkonium production at two loops by carrying out a covariant calculation of the nonrelativistic quantum chromodynamics (NRQCD) long-distance matrix element (LDME) for a heavy-quark pair in an S-wave, color-octet state to fragment into a heavy-quark pair in a color-singlet state of arbitrary orbital angular momentum. The NRQCD factorization conjecture for the universality of the LDME requires that infrared divergences that it contains be independent of the direction of the Wilson line that appears in its definition. We find this to be the case in our calculation. The results of our calculation differ in some respects from those of a previous calculation that was carried out by Nayak, Qiu, and Sterman using light-cone methods. We have identified the sources of some of these differences. The results of both calculations are consistent with the NRQCD factorization conjecture. However, the general principle that underlies this confirmation of NRQCD factorization at two-loop order has yet to be revealed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power Hardware-in-the-Loop Testing of a Smart Distribution System

This paper presents the results of the third and final phase of the National Renewable Energy Lab (NREL) INTEGRATE demonstration: Smart Distribution. For this demonstration, high penetrations of solar PV and wind energy systems were simulated in a power hardware-in-the-loop set-up using a smart distribution test feeder. Simulated and real DERs were controlled by a real-time control platform, which manages grid constraints under high clean energy deployment levels. The power HIL testing, conducted at NREL's ESIF smart power lab, demonstrated how dynamically managing DER increases the grid's hosting capacity by leveraging active network management's (ANM) safe and reliable control framework. Results are presented for how ANM's real-time monitoring, automation, and control can be used to manage multiple DERs and multiple constraints associated with high penetrations of DER on a distribution grid. The project also successfully demonstrated the importance of escalating control actions given how ANM enables operation of grid equipment closer to their actual physical limit in the presence of very high levels of intermittent DER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-loop Testing of Network Protectors for Low-Voltage Networks with Distributed Energy Resources

In this report, we developed and validated a network protector relay digital twin model and interfaced a commonly used network protector relay hardware with our real-time simulation system. Hardware-in-the-loop protection studies are performed to assess the impact of distributed energy resources (DER) and benchmark a rate-of-change-based mitigation strategy. Simulation results suggest that the network protector reverse trip and auto-reclose functions are negatively impacted by the high distributed energy resource penetration. To accommodate DER backfeed while remaining secure and reliable for faults on primary feeders, we recommend options for a rate-of-change-based blocking scheme and a protection setting change. Finally, future mitigation ideas and standard revisions are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Temperature Fluoride Salt Test Loop

Effective high-temperature thermal energy exchange and delivery at temperatures over 600°C has the potential of significant impact by reducing both the capital and operating cost of energy conversion and transport systems. It is one of the key technologies necessary for efficient hydrogen production and could potentially enhance efficiencies of high-temperature solar systems. Today, there are no standard commercially available high-performance heat transfer fluids above 600°C. High pressures associated with water and gaseous coolants (such as helium) at elevated temperatures impose limiting design conditions for the materials in most energy systems. Liquid salts offer high-temperature capabilities at low vapor pressures, good heat transport properties, and reasonable costs and are therefore leading candidate fluids for next-generation energy production. Liquid-fluoride-salt-cooled, graphite-moderated reactors, referred to as Fluoride Salt Reactors (FHRs), are specifically designed to exploit the excellent heat transfer properties of liquid fluoride salts while maximizing their thermal efficiency and minimizing cost. The FHR s outstanding heat transfer properties, combined with its fully passive safety, make this reactor the most technologically desirable nuclear power reactor class for next-generation energy production. Multiple FHR designs are presently being considered. These range from the Pebble Bed Advanced High Temperature Reactor (PB-AHTR) [1] design originally developed by UC-Berkeley to the Small Advanced High-Temperature Reactor (SmAHTR) and the large scale FHR both being developed at ORNL [2]. The value of high-temperature, molten-salt-cooled reactors is also recognized internationally, and Czechoslovakia, France, India, and China all have salt-cooled reactor development under way. The liquid salt experiment presently being developed uses the PB-AHTR as its focus. One core design of the PB-AHTR features multiple 20 cm diameter, 3.2 m long fuel channels with 3 cm diameter graphite-based fuel pebbles slowly circulating up through the core. Molten salt coolant (FLiBe) at 700°C flows concurrently (at significantly higher velocity) with the pebbles and is used to remove heat generated in the reactor core (approximately 1280 W/pebble), and supply it to a power conversion system. Refueling equipment continuously sorts spent fuel pebbles and replaces spent or damaged pebbles with fresh fuel. By combining greater or fewer numbers of pebble channel assemblies, multiple reactor designs with varying power levels can be offered. The PB-AHTR design is discussed in detail in Reference [1] and is shown schematically in Fig. 1. Fig. 1. PB-AHTR concept (drawing taken from Peterson et al., Design and Development of the Modular PB-AHTR Proceedings of ICApp 08). Pebble behavior within the core is a key issue in proving the viability of this concept. This includes understanding the behavior of the pebbles thermally, hydraulically, and mechanically (quantifying pebble wear characteristics, flow channel wear, etc). The experiment being developed is an initial step in characterizing the pebble behavior under realistic PB-AHTR operating conditions. It focuses on thermal and hydraulic behavior of a static pebble bed using a convective salt loop to provide prototypic fluid conditions to the bed, and a unique inductive heating technique to provide prototypic heating in the pebbles. The facility design is sufficiently versatile to allow a variety of other experimentation to be performed in the future. The facility can accommodate testing of scaled reactor components or sub-components such as flow diodes, salt-to-salt heat exchangers, and improved pump designs as well as testing of refueling equipment, high temperature instrumentation, and other reactor core designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bubble Mass Transport Measurement in the Large-Scale Test Loops at Oak Ridge National Laboratory

Molten salts are complex fluids that incorporate multi-phase behavior depending on the chemistry and the physical properties of the entrained components. These components include the carrier salt, the actinide fuel, and fission, activation, and corrosion products, the concentrations of which depends on the burnup history of the salt. Radionuclide transport from the salt into the cover gas / off-gas system depends on volatility as predicted by thermochemistry, but data from the Molten Salt Reactor Experiment (MSRE) conducted in the late 1960s suggest that bubble formation and transport are also important. Anomalously high fractions of noble metals were found in the off-gas system and were attributed to transportation with parent salt aerosols and their association with rising noble gas bubbles. The prediction of such phenomena requires coupled neutronic, thermal hydraulic, and chemical equilibrium calculations, the framework of which is being developed within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supported by the US Department of Energy (DOE) Office of Nuclear Energy (NE). However, separate effects tests and models of experiments using tools such as SAM and Thermochimica can guide model developers through important processes. Conversely, model development guides the choice of experiments and systems to provide data that are relevant for validation. This report describes several experiments that tracked gas transport in molten salts, ranging from small-scale systems to large-scale loops. Gas transportation in a molten salt, LiCl-KCl, has been studied using the shadowgraph technique. Sensors such as residual gas analysis, Raman spectroscopy, and laser-induced breakdown spectroscopy have been tested for off-gas measurements. These data were used to interpret how the gases move through the upstream salt / cover gas and the interface between them. Differential pressure measurements were able to detect individual gas bubbles as they popped at the liquid–gas interface. Salt aerosols were collected on a cascade impactor. Their formation was also observed directly via the shadowgraph method, and most of these aerosols were launched ballistically into the cover gas. Fine mists could also be observed. Convection currents through the salt were visualized and can be used to calculate the thermophysical properties of the salt itself. The apparatuses described in this report and in a previous work (McFarlane et al. 2023) have been commissioned and are available for use in making further measurements of salt/surrogate fission product behavior. Novel approaches using neutron imaging are planned for the study of fluoride salts, which cannot be contained in quartz, so shadowgraph visualization is not available. Bubble transport in convective flow and in a slow-moving salt column are planned. The mobile laser-induced breakdown spectroscopy (LIBS) system is available for several applications, including iodine capture in a molten hydroxide scrubber, H2 transport though molten salts to complement Raman analysis, and online tracking of salt aerosol generation, transport, and deposition. This report summarizes the findings from FY24 and the plans for FY25. The work completes milestone M2AT-24OR0702013 of the DOE-NE Advanced Reactor Technology, Molten Salt Reactor Campaign, DOE-NE-5.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

One-loop tests of supersymmetric gauge theories on spheres

Here, we show that a recently conjectured form for perturbative supersymmetric partition functions on spheres of general dimension d is consistent with the at space limit of 6-dimensional N = 1 super Yang-Mills. We also show that the partition functions for N = 1 8- and 9-dimensional theories are consistent with their known at space limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗