A Review of Ultralow Temperature and Low Background Facilities at Fermilab
This presentation provides an overview of ultralow temperature.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation provides an overview of ultralow temperature.
Quantifying the effects of radiation on the operation of qubits both as quantum information systems as well as particle detectors has emerged as a pressing issue in quantum science in recent years. We present an overview of the design, operation, and deployment of a 90-$\mathrm{in}^2$ three-panel muon detector for use in the NEXUS experimental facility at Fermilab to temporally isolate correlated errors in qubits and determine if they possess an astrophysical origin. Constructed with three scintillator-attached PMTs read out with NIM modules in a triply-coincident logic scheme, we measure a surface-level muon luminosity of 9.7425 muons per second---consistent with an average surface-level cosmic-ray flux of approximately one muon per square centimeter per minute. Integrating the NIM modules with an MCC 128 DAQ HAT and Raspberry Pi, a Python script records exactly when a muon struck the detector and writes a timestamp to a log file for follow-up cross referencing. This experiment will broadly contribute to further studies aimed at understanding the source and mitigation of information loss in qubits.
Explore the source record for details and available documents.
Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).
Explore the source record for details and available documents.
Spectrophone detects very small concentrations of trace gases. With gas in sample cell, laser is tuned to absorption line of interest. Molecular absorption in cell produces pulsed acoustical pressure at chopper frequency. Two optical paths with very different absorption lengths are used to pretune cell to balance out background absorption by cell windows.
The various noise sources that affect InSb detectors (and similar voltaic devices) are discussed and calculated. Methods are given for measuring detector resistance, photon loading, detector and amplifier capacitance, amplifier frequency response, amplifier noise, and quantum efficiency. A photovoltaic InSb detector with increased sensitivity in the 1 to 5.6 mu region is dicussed.
A program of testing aimed at the evaluation of systems that have the potential to provide the level of performance required for use in space-based instruments was undertaken and their usefulness appraised for astronomy. The results of the first phase of the program to characterize selected pixels of a HgCdTe photovoltaic array detector were reported.
The design of a 128x128 staring short wave infrared (SWIR) HgCdTe focal plane incorporating charge integrating transimpedance input preamplifiers is presented. The preamplifiers improve device linearity and uniformity, and provide signal gain ahead of the miltiplexer and readout circuitry. Detector's with cutoff wavelength of 2.5 microns and operated at 80 K have demonstrated impedances in excess of 10(exp 16) ohms with 60 percent quantum efficiency. Focal plane performance using a smaller format device is presented which demonstrates the potential of this approach. Although the design is capable of achieving less than 30 rms electrons with todays technology, initial small format devices demonstrated a read noise of 100 rms electrons and were limited by the atypical high noise performance of the silicon process run. Luminescence from the active silicon circuitry in the multiplexer limits the minimum detector current to a few hundred electrons per second. Approaches to eliminate this excessive source of current is presented which should allow the focal plane to achieve detector background limited performance.
Cobalt samples were analyzed for cosmic ray induced Co-60 with both an ultralow background germanium gamma ray spectrometer and with a large NaI(T1) multidimensional spectrometer using electronic anticoincidence shielding. Aluminum samples were analyzed for Na-22. The results are presented along with the relative sensitivities and precision afforded by the two methods.
Mini-Magnetospheric Plasma Propulsion (M2P2) seeks the creation of a large-scale (10 km radius) magnetic wall or bubble (i.e. a magnetosphere) by the electromagnetic inflation of a small-scale (20 cm radius) dipole magnet. The inflated magnetosphere will intercept the solar wind and thereby provide high-speed propulsion with modest power and fuel requirements due to the gain provided by the ambient medium. Magnetic field inflation is produced by the injection of plasma onto the dipole magnetic field eliminating the need for large mechanical structures and added material weight at launch. For successful inflation of the magnetic bubble a beta near unity must be achieved along the imposed dipole field. This is dependent on the plasma parameters that can be achieved with a plasma source that provide continuous operation at the desired power levels of 1 to 2 kilowatts. Over the last two years we have been developing a laboratory prototype to demonstrate the inflation of the magnetic field under space-like conditions. In this paper we will present some of the latest results from the prototype development at the University of Washington and show that the prototype can produce high ionization efficiencies while operating in near space like neutral background pressures producing electron temperatures of a few tens of electron volts. This allows for operation with propellant expenditures lower than originally estimated.
QWIPs operate by photoexcitation of electrons between ground and first excited state subbands of multi-quantum wells (MQWs) which are artificially fabricated by placing thin layers of two dfferent, high-bandgap semiconductor materials alternately. The bandgap discontinuity of two materials creates quantized subbands in the potential wells associated with conduction bands.
No abstract available
A long-wavelength large format Quantum Well Infrared Photodetector (QWIP) focal plane array has been successfully used in a ground based astronomy experiment.
Quantifying the effects of radiation on the operation of qubits both as quantum information systems as well as particle detectors has emerged as a pressing issue in quantum science in recent years. We present an overview of the design, operation, and deployment of a 90-$\mathrm{in}^2$ three-panel muon detector for use in the NEXUS experimental facility at Fermilab to temporally isolate correlated errors in qubits and determine if they possess an astrophysical origin. Constructed with three scintillator-attached PMTs read out with NIM modules in a triply-coincident logic scheme, we measure a surface-level muon luminosity of 9.7425 muons per second---consistent with an average surface-level cosmic-ray flux of approximately one muon per square centimeter per minute. Integrating the NIM modules with an MCC 128 DAQ HAT and Raspberry Pi, a Python script records exactly when a muon struck the detector and writes a timestamp to a log file for follow-up cross referencing. This experiment will broadly contribute to further studies aimed at understanding the source and mitigation of information loss in qubits.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Available solid state photomultiplier (SSPM) detectors were tested under low-background, low temperature conditions to determine the conditions producing optimal sensitivity in a space-based astronomy system such as a liquid cooled helium telescope in orbit. Detector temperatures varied between 6 and 9 K, with background flux ranging from 10 to the 13th power to less than 10 to the 6th power photons/square cm-s. Measured parameters included quantum efficiency, noise, dark current, and spectral response. Experimental data were reduced, analyzed, and combined with existing data to build the SSPM data base included herein. The results were compared to analytical models of SSPM performance where appropriate models existed. Analytical models presented here were developed to be as consistent with the data base as practicable. Significant differences between the theory and data are described. Some models were developed or updated as a result of this study.