Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Origin of mechanical and dielectric losses from two-level systems in amorphous silicon

Amorphous silicon contains tunneling two-level systems, which are the dominant energy loss mechanisms for amorphous solids at low temperatures. These two-level systems affect both mechanical and electromagnetic oscillators and are believed to produce thermal and electromagnetic noise and energy loss. However, it is unclear whether the two-level systems that dominate mechanical and dielectric losses are the same; the former relies on the coupling between phonons and two-level systems, with an elastic field coupling constant γ while the latter depends on a two-level systems dipole moment p0, which couples to the electromagnetic field. Mechanical and dielectric loss measurements as well as structural characterization were performed on amorphous silicon thin films grown by electron beam deposition with a range of growth parameters. Samples grown at 425 °C show a large reduction of mechanical loss (34 times) and a far smaller reduction of dielectric loss (2.3 times) compared to those grown at room temperature. Additionally, mechanical loss shows lower loss for thicker films, while dielectric loss shows lower loss for thinner films. Overall, analysis of these results indicate that mechanical loss correlates with atomic density, while dielectric loss correlates with dangling-bond density, suggesting a different origin for these two energy dissipation processes in amorphous silicon.

36 MATERIALS SCIENCE↗

Dynamic Cooling on Contemporary Quantum Computers

We study the problem of dynamic cooling whereby a target qubit is cooled at the expense of heating up N − 1 further identical qubits by means of a global unitary operation. A standard back-of-the-envelope high-temperature estimate establishes that the target qubit temperature can be dynamically cooled by at most a factor of 1 / N . Here we provide the exact expression for the minimum temperature to which the target qubit can be cooled and reveal that there is a crossover from the high initial temperature regime, where the scaling is 1 / N , to a low initial temperature regime, where a much faster scaling of 1 / N occurs. This slow, 1 / N scaling, which was relevant for early high-temperature NMR quantum computers, is the reason dynamic cooling was dismissed as ineffectual around 20 years ago; the fact that current low-temperature quantum computers fall in the fast, 1 / N scaling regime, reinstates the appeal of dynamic cooling today. We further show that the associated work cost of cooling is exponentially more advantageous in the low-temperature regime. We discuss the implementation of dynamic cooling in terms of quantum circuits and examine the effects of hardware noise. We successfully demonstrate dynamic cooling in a three-qubit system on a real quantum processor. Since the circuit size grows quickly with N , scaling dynamic cooling to larger systems on noisy devices poses a challenge. We therefore propose a suboptimal cooling algorithm, whereby relinquishing a small amount of cooling capability results in a drastically reduced circuit complexity, greatly facilitating the implementation of dynamic cooling on near-future quantum computers. Published by the American Physical Society2024

Physics↗

A multi-channel cryogenic low-noise skipper-CCD readout ASIC

• Skipper CCDs provide exceptionally low noise useful for dark matter detection• MIDNA ASIC enables scaled cryogenic Skipper CCD readout• Noise performance proven to specification at room temperature with CCD• Liquid nitrogen measurements show functionality with more to come• Future development will integrate more sensitive signals and averaging capability

England, Troy↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Cryogenic-Refined MOSFET Modeling for Oscillator, Frequency Divider, and Amplifier Designs Below 4 K

Capturing device characteristic changes at cryogenic temperatures is crucial for cryo-CMOS circuit designs. In this work, we present an isothermal cryogenic-refined modeling approach for CMOS transistors that is simple, low overhead, and easy to implement while offering the required accuracy for predicting circuit performance at the designated temperatures. Guided by die-level measurement data and circuit design principles, the model introduces corrections to only five critical parameters: threshold voltage, carrier mobility, elevated low-frequency flicker noise, dominant high-frequency shot noise, and subthreshold swing (SS). These refinements are implemented around the foundry-provided SPICE model, which is typically validated only down to about 200 K. With these adjustments, the proposed cryogenic-refined model achieves less than 5% error in both large-signal metrics (I–V characteristics) and small-signal parameters (e.g., transconductance) when compared with device measurements at deep-cryogenic temperatures. The methodology is validated in two advanced technologies: TSMC 40-nm CMOS and GlobalFoundries (GF) 45-nm RF-SOI. We further demonstrate its applicability in three representative RF circuits: a 30-GHz LC oscillator, a high-speed current-mode-logic (CML) frequency divider (FD), and a subthreshold Gb/s amplifier, all showing close agreement between simulated predictions and measurements performed at 4 and 2.5 K. Finally, we believe that the proposed approach is implementation-friendly and can significantly accelerate the development of cryo-CMOS integrated circuits.

circuit modeling↗

Single-photon detection using high-temperature cuprate superconductors

The detection of individual quanta of light is important for quantum computation, fluorescence lifetime imaging, single-molecule detection, remote sensing, correlation spectroscopy, and more. Thanks to their broadband operation, high detection efficiency, exceptional signal-to-noise ratio, and fast recovery times, superconducting nanowire single-photon detectors (SNSPDs) have become a critical component in these applications. The operation of SNSPDs based on conventional superconductors, which have a low critical temperature (T c ), requires costly and bulky cryocoolers. This motivated exploration of other superconducting materials with higher T c that would enable single-photon detection at elevated temperatures, yet this task has proven exceedingly difficult. Here we show that with proper processing, high-T c cuprate superconductors can meet this challenge. We fabricated superconducting nanowires (SNWs) out of thin flakes of Bi 2 Sr 2 CaCu2O 8+δ and La 1.55 Sr 0.45 CuO 4 /La 2 CuO 4 (LSCO-LCO) bilayer films and demonstrated their single-photon response up to 25 and 8 K, respectively. The single-photon operation is revealed through the linear scaling of the photon count rate (PCR) on the radiation power. Both of our cuprate-based SNSPDs exhibited single-photon sensitivity at the technologically-important 1.5 μm telecommunications wavelength. Our work expands the family of superconducting materials for SNSPD technology, opens the prospects of raising the temperature ceiling, and raises important questions about the underlying mechanisms of single-photon detection by unconventional superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗

Noise reduction of stochastic density functional theory for metals

Density Functional Theory (DFT) has become a cornerstone in the modeling of metals. However, accurately simulating metals, particularly under extreme conditions, presents two significant challenges. First, simulating complex metallic systems at low electron temperatures is difficult due to their highly delocalized density matrix. Second, modeling metallic warm-dense materials at very high electron temperatures is challenging because it requires the computation of a large number of partially occupied orbitals. This study demonstrates that both challenges can be effectively addressed using the latest advances in linear-scaling stochastic DFT methodologies. Despite the inherent introduction of noise into all computed properties by stochastic DFT, this research evaluates the efficacy of various noise reduction techniques under different thermal conditions. Our observations indicate that the effectiveness of noise reduction strategies varies significantly with the electron temperature. Furthermore, we provide evidence that the computational cost of stochastic DFT methods scales linearly with system size for metal systems, regardless of the electron temperature regime.

Chemistry↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Disentangling the impact of quasiparticles and two-level systems on the statistics of superconducting-qubit lifetime

Temporal fluctuations in the superconducting qubit lifetime, T 1 , present additional challenges in the pursuit of fault-tolerant quantum computing. Although the exact mechanisms remain unclear, T 1 fluctuations are generally attributed to strong coupling between the qubit and a few near-resonant two-level systems (TLSs), which can exchange energy with an ensemble of thermally fluctuating two-level fluctuators (TLFs) at low frequencies. Here, we report T 1 measurements of qubits with varying geometrical footprints and surface dielectrics as a function of temperature. By analyzing the noise spectrum of the qubit depolarization rate, Γ 1 = 1 / T 1 , we disentangle the contributions of TLSs, nonequilibrium quasiparticles (QPs), and equilibrium (thermally excited) QPs to the variance in Γ 1 . We find that the Γ 1 variance in qubits with smaller footprints is more susceptible to QP and TLS fluctuations than that in larger-footprint qubits. Furthermore, the QP-induced variances in all qubits align with the theoretical framework of QP diffusion and fluctuation. These findings offer valuable insights for future qubit design and engineering optimization.

Zhu, Shaojiang [Fermilab] (ORCID:0000000293180092)↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

Anomalous Loss Reduction Below Two‐Level System Saturation in Aluminum Superconducting Resonators

Superconducting resonators are widely used in many applications such as qubit readout for quantum computing, and kinetic inductance detectors. These resonators are susceptible to numerous loss and noise mechanisms, especially the dissipation due to two-level systems (TLS) which become the dominant source of loss in the few-photon and low temperature regime. In this study, capacitively-coupled aluminum half-wavelength coplanar waveguide resonators are investigated. Surprisingly, the loss of the resonators is observed to decrease with a lowering temperature at low excitation powers and temperatures below the TLS saturation. This behavior is attributed to the reduction of the TLS resonant response bandwidth with decreasing temperature and power to below the detuning between the TLS and the resonant photon frequency in a discrete ensemble of TLS. When response bandwidths of TLS are smaller than their detunings from the resonance, the resonant response and thus the loss is reduced. At higher excitation powers, the loss follows a logarithmic power dependence, consistent with predictions from the generalized tunneling model (GTM). A model combining the discrete TLS ensemble with the GTM is proposed and matches the temperature and power dependence of the measured internal loss of the resonator with reasonable parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exceptional stratospheric contribution to human fingerprints on atmospheric temperature

In 1967, scientists used a simple climate model to predict that human-caused increases in atmospheric CO 2 should warm Earth’s troposphere and cool the stratosphere. This important signature of anthropogenic climate change has been documented in weather balloon and satellite temperature measurements extending from near-surface to the lower stratosphere. Stratospheric cooling has also been confirmed in the mid to upper stratosphere, a layer extending from roughly 25 to 50 km above the Earth’s surface (S 25 − 50 ). To date, however, S 25 − 50 temperatures have not been used in pattern-based attribution studies of anthropogenic climate change. Here, we perform such a “fingerprint” study with satellite-derived patterns of temperature change that extend from the lower troposphere to the upper stratosphere. Including S 25 − 50 information increases signal-to-noise ratios by a factor of five, markedly enhancing fingerprint detectability. Key features of this global-scale human fingerprint include stratospheric cooling and tropospheric warming at all latitudes, with stratospheric cooling amplifying with height. In contrast, the dominant modes of internal variability in S 25 − 50 have smaller-scale temperature changes and lack uniform sign. These pronounced spatial differences between S 25 − 50 signal and noise patterns are accompanied by large cooling of S 25 − 50 (1 to 2 ° C over 1986 to 2022) and low S 25 − 50 noise levels. Our results explain why extending “vertical fingerprinting” to the mid to upper stratosphere yields incontrovertible evidence of human effects on the thermal structure of Earth’s atmosphere.

climate modeling↗

New, improved analysis of correlation ECE data to accurately determine turbulent electron temperature spectra and magnitudes (invited)

Turbulent electron temperature fluctuation measurement using a correlation electron cyclotron emission (CECE) radiometer has become an important diagnostic for studying energy transport in fusion plasmas, and its use is widespread in tokamaks (DIII-D, ASDEX Upgrade, Alcator C-Mod, Tore Supra, EAST, TCV, HL-2A, etc.). The CECE diagnostic typically performs correlation analysis between two closely spaced (within the turbulent correlation length) ECE channels that are dominated by uncorrelated thermal noise emission. This allows electron temperature fluctuations embedded in the thermal noise to be revealed and fluctuation level and spectra determined. We have demonstrated a new, improved CECE coherency-based analysis for calculating the temperature fluctuation frequency spectrum and level, which has been verified both numerically through the simulation of synthetic ECE radiometer data and through analysis of experimental data from the CECE system on DIII-D. The new formulation places coherency-based analysis on a firm foundational footing and corrects some currently published methodologies. This new method accurately accounts for bias error in the coherence function and correctly calculates noise levels for a fixed data record length. It provides excellent accuracy in determining temperature fluctuation level (e.g., <10% error) even for a small realization number in the ensemble average. The method also has a smaller uncertainty (i.e., error bar) in the power spectrum when compared to the more standard cross-power method when evaluated at low coherency. Direct calculation of system noise level using correlation between randomized intermediate frequency signals is recommended.

Wang, G. (ORCID:0000000225739827)↗

Magneto-Optical Sensing Beyond the Shot Noise Limit

Magneto-optical sensors including spin noise spectroscopies and magneto-optical Kerr effect microscopies are now ubiquitous tools for materials characterization that can provide new understanding of spin dynamics, hyperfine interactions, spin-orbit interactions, and charge-carrier g-factors. Both interferometric and intensity-difference measurements can provide photon-shot-noise-limited sensitivity, but further improvements in sensitivity with classical resources require either increased laser power that can induce unwanted heating and electronic perturbations or increased measurement times that can obscure out-of-equilibrium dynamics and slow experimental throughput. Proof-of-principle measurements have already demonstrated quantum enhanced spin noise measurements with a squeezed readout field that are likely to be critical to the nonperturbative characterization of spin excitations in quantum materials that emerge at low temperatures. Here, a truncated nonlinear interferometric readout for low-temperature magneto-optical Kerr effect and related magneto-optical microscopies that is accessible with today's quantum optical resources is proposed. 10 nrad/$\sqrt{Hz}$ sensitivity is achievable with optical power as small as 1 µW. As a result, measurements may be performed at temperatures as low as 83 mK in commercially available dilution refrigerators. This combination of high sensitivity and low operating temperature is impossible to achieve with any classical measurement. The quantum advantage for the proposed measurements persists even in the limit of large loss and small squeezing parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗