Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic field amplification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

In situ amplification of spin echoes within a kinetic inductance parametric amplifier

The use of superconducting microresonators together with quantum-limited Josephson parametric amplifiers has enhanced the sensitivity of pulsed electron spin resonance (ESR) measurements by more than four orders of magnitude. So far, the microwave resonators and amplifiers have been designed as separate components due to the incompatibility of Josephson junction–based devices with magnetic fields. This has produced complex spectrometers and raised technical barriers toward adoption of the technique. Here, we circumvent this issue by coupling an ensemble of spins directly to a weakly nonlinear and magnetic field–resilient superconducting microwave resonator. We perform pulsed ESR measurements with a 1-pL mode volume containing 6 × 10 7 spins and amplify the resulting signals within the device. When considering only those spins that contribute to the detected signals, we find a sensitivity of 2.8 x 10 3 spins / $\sqrt{Hz}$ for a Hahn echo sequence at a temperature of 400 mK. In situ amplification is demonstrated at fields up to 254 mT, highlighting the technique’s potential for application under conventional ESR operating conditions.

42 ENGINEERING↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

RASER MRI: Magnetic resonance images formed spontaneously exploiting cooperative nonlinear interaction

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/T 2 * . Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Axial magnetic flux amplification in Hall-magnetohydrodynamic simulations of externally magnetized z-pinches

It is shown that externally magnetized gas-puff z-pinches under compression can exhibit robust axial flux amplification under suitable axial boundary conditions. This effect relies upon the Hall term in the generalized Ohm's law to generate azimuthal currents in the presence of a driving axial electric field. Under dynamic compression, the total current tends to flow in a mostly force-free boundary layer, separating the predominately azimuthal field outside the layer and the predominately axial field inside the layer. The effect only appears to occur if the axial boundaries allow for outflow or absorption of electromagnetic energy. The effect is mitigated by imposing either periodic or conducting axial boundary conditions. A semi-analytic equilibrium analysis agrees with steady-state solutions of the time-dependent electron-magnetohydrodynamic equations and provides an estimate of the scaling of the boundary layer as well as suggesting a scenario for the formation of the boundary layer. When operative, the effect can significantly impede plasma compression due to the increase in axial flux that diffuses into the pre-compressed plasma or through the presence of conductors that inhibit movement of the generated axial flux. Several facilities have noted unusual implosion behavior in z-pinch experiments with applied axial fields that does not appear to be explainable within the standard magnetohydrodynamic model. In conclusion, it is suggested that these experiments can be explained by the axial flux amplification and concentration effect

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient 15 N hyperpolarization of [ 15 N 3 ]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH

Signal Amplification by Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) is an NMR hyperpolarization technique that relies of the simultaneous exchange of parahydrogen and a to-be-hyperpolarized molecule on the metal center of a polarization-transfer catalyst in a microtesla magnetic field. Until recently, this method has been understood to perform hyperpolarization by establishing level anti-crossings between the nuclear spins of the parahydrogen derived hydrides (acting as a source of hyperpolarization) and those of the substrate. Recently, the application of highly non-intuitive pulse sequences (comprising pulses of microtesla DC fields) was predicted to hyperpolarize nuclear spins more efficiently than the canonical (static-field) SABRE-SHEATH approach. Here we show that by employing a basic “on-off” pulse sequence of rectangular microtesla pulses, it is possible to improve the hyperpolarization efficiency for SABRE-SHEATH of [ 15 N 3 ]metronidazole, an FDA-approved antibiotic (in non-enriched and non-hyperpolarized form) and potential hypoxia sensing molecule. Specifically, we demonstrate that 15N polarization of 18.5 % can be obtained in 80 s of parahydrogen bubbling parahydrogen through a solution containing 20 mM [ 15 N 3 ]metronidazole. In practice, (1.32 ± 0.14)-fold improvements in P 15N was obtained with the pulsed method described here compared to static field technique variant. These results show that pulsed SABRE-SHEATH was successfully applied to 15 N-labeled biologically relevant molecule. Moreover, we also demonstrate that although the pulsed SABRE-SHEATH sequence was designed for polarization transfer from parahydrogen derived hydrides to the metronidazole’s 15 N catalyst-binding site, all three 15 N sites of [ 15 N 3 ]metronidazole attained the hyperpolarized state. This spin-relayed polarization transfer becomes possible due to the 15 N relay network established by their spin-spin J-couplings. The feasibility of the spin-relayed polarization transfer is demonstrated here for the first time for pulsed SABRE-SHEATH (as opposed to the static-field SABRE-SHEATH reported previously) and it paves the way to broad applicability of the technique.

Hyperpolarization↗

Drift kinetic effects on plasma response to resonant magnetic perturbation for EU DEMO design

Abstract A systematic investigation of the plasma response to an externally applied resonant magnetic perturbation (RMP) field, for the purpose of controlling edge localized modes, is carried out for an EU DEMO reference plasma. Particular emphasis is placed on the role of kinetic effects associated with both thermal particles and fusion-born alphas. The single fluid, resistive model predicts a large peak amplification of the n = 1 ( n is the toroidal mode number) plasma response to the target equilibrium, which is found to be close to the Troyon no-wall limit. A more advanced response model, including kinetic resonances between the RMP perturbation and drift motions of thermal and energetic particles, on the other hand, finds a strong suppression of the n = 1 field amplification. A major role is played by the precessional drift resonance of fusion-born alphas. A strong parallel sound wave damping model is found to well reproduce the full kinetic response results for the DEMO plasma, in terms of both the resonant field response amplitude and the plasma displacement. Finally, both fluid and kinetic models produce similar responses for the n = 2 and 3 RMP fields for the considered DEMO plasma, whilst kinetic effects again become important for the n = 4 RMP due to proximity of the reference plasma to the no-wall limit for the n = 4 ideal kink instability.

Physics↗

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning magneto-optical zero reflection via dual-channel hybrid magnonics

Multichannel coupling in hybrid systems makes an attractive testbed not only because of the distinct advantages entailed by each constituent mode but also because the opportunity to leverage interference among the various excitation pathways. Here, via combined analytical calculation and experiment, we demonstrate that the phase of the magnetization precession at the interface of a coupled yttrium iron garnet (YIG)/permalloy (Py) bilayer is collectively controlled by the microwave photon field torque and the interlayer exchange torque, manifesting a coherent, dual-channel excitation scheme that effectively tunes the magneto-optical spectrum. Furthermore, the different torque contributions vary with frequency, external bias field, and type of interlayer coupling between YIG and Py, which further results in destructive or constructive interferences between the two excitation channels, and hence selective suppression or amplification of the hybridized magnon modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Driven resonant current amplification in self-organized plasma configurations with uniform λ and plasma pressure confinement

Driven resonant current amplification in uniform λ=$^{μoJ}_{B}$, self-organized plasma configurations with plasma pressure confinement is studied. This work extends previous analyses of force-free states (J ∥ B) to equilibria with plasma pressure gradients (∇P = J × B ≠ 0). An analytical treatment shows that in equilibria with uniform λ and a plasma pressure gradient that varies linearly with poloidal magnetic flux, driven resonances are either downshifted or upshifted from their force-free values. Additionally, a modification of off resonance current amplification is observed in pressure confining equilibria. Computational results add support to analytical predictions, and also include driven resonance behavior with equilibrium profiles not considered analytically. Furthermore, these results suggest not only persistence, but also modification of driven resonant current amplification in sustained spheromak configurations with plasma pressure confinement when compared to force-free states. By providing a basis for the existence of driven, high current amplification, pressure confining equilibria, this work provides insight into the accessibility of sustained spheromak states of most interest for potential fusion energy applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the study of hydrodynamic instabilities in the presence of background magnetic fields in high-energy-density plasmas

Blast-wave-driven hydrodynamic instabilities are studied in the presence of a background B-field through experiments and simulations in the high-energy-density (HED) physics regime. In experiments conducted at the Laboratoire pour l’utilisation des lasers intenses (LULI), a laser-driven shock-tube platform was used to generate a hydrodynamically unstable interface with a prescribed sinusoidal surface perturbation, and short-pulse x-ray radiography was used to characterize the instability growth with and without a 10-T B-field. The LULI experiments were modeled in FLASH using resistive and ideal magnetohydrodynamics (MHD), and comparing the experiments and simulations suggests that the Spitzer model implemented in FLASH is necessary and sufficient for modeling these planar systems. These results suggest insufficient amplification of the seed B-field, due to resistive diffusion, to alter the hydrodynamic behavior. Although the ideal-MHD simulations did not represent the experiments accurately, they suggest that similar HED systems with dynamic plasma-β (=2μ0ρv2/B2) values of less than ∼100 can reduce the growth of blast-wave-driven Rayleigh–Taylor instabilities. These findings validate the resistive-MHD FLASH modeling that is being used to design future experiments for studying B-field effects in HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic magneto-chiral instability in photoexcited tellurium

In systems of charged chiral fermions out of equilibrium, an electric current parallel to a magnetic field can generate a dynamic instability that amplifies electromagnetic waves. Whether this mechanism also operates in chiral solid-state systems has remained uncertain. Here we observe signatures of a dynamic magneto-chiral instability in elemental tellurium, a structurally chiral crystal, using time-domain terahertz emission spectroscopy. Under transient photoexcitation in a moderate magnetic field, we observe terahertz radiation with coherent modes that grow in amplitude over time. We present a theoretical model that describes this behaviour based on a dynamic instability of electromagnetic waves interacting with infrared-active oscillators of acceptor states in tellurium, giving rise to an amplifying polariton. These results demonstrate that magneto-chiral instabilities can emerge in solid-state systems and establish a mechanism for terahertz-wave amplification in chiral materials.

42 ENGINEERING↗

Rapid RASER MRI

Conventional Magnetic Resonance Imaging (MRI) relies on high-power Radio-Frequency (RF) pulses to excite nuclear spins and in turn generate NMR signals. These pulses require large high-power RF-amplifiers and cause heat deposition in the tissue, which must be minimized for safety, presenting a growing problem when moving toward ever-higher field MRI. An alternative to RF-pulse excitation is self-excitation of nuclear spins using Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), where the nuclear spins undergo spontaneous transition, without RF excitation, from an over-populated state to a ground state. Here, the feasibility of recording rapid proton RASER MRI images of pyrazine at low concentration (120 mM) with large matrix (128x128 pixels) in as little as 78 ms is demonstrated at 500 MHz (11.7 T). We also recorded a time-series of images using a single bolus hyperpolarized pyrazine highlighting the feasibility of dynamic tracking. Here, the demonstrated approach allows recording MRI scans without transmit-receive electronics of the MRI scanner, which is highly desirable for portable MRI as well as the emerging field of hyperpolarized MRI using, e.g., HP protons, 129 Xe gas or HP 13 C labeled biomolecules as molecular tracers and imaging agents.

MRI↗

Solar Wind Turbulence from 1 to 45 au. III. Anisotropy of Magnetic Fluctuations in the Inertial Range Using Voyager and ACE Observations

We examine both Voyager and Advanced Composition Explorer magnetic field measurements at frequencies that characterize the inertial range and evaluate the anisotropy of the fluctuations as they relate to both the compressive component and underlying wavevector anisotropy of the turbulence. The magnetic fluctuation anisotropy as it relates to the compressive component is directly dependent upon both the plasma beta of the thermal proton component and the ratio of magnetic fluctuation magnitude to the strength of the mean magnetic field. This has been seen before at 1 au. The magnetic fluctuation anisotropy in the plane perpendicular to the mean magnetic field, which is a measure of the anisotropy of the underlying wavevector distribution, should depend on the angle between the mean magnetic field and the radial direction and should be confined to values between one and the index of the power spectrum, which is typically 5/3. Our results show that the average of this anisotropy exceeds the value of the spectral index and is out of bounds with the theory. Although the results are suggestive of past analyses, we find that spherical expansion of the turbulence may offer at least a partial explanation of the apparent amplification of this measured anisotropy.

heliosphere↗

Strongly Tapered Helical Undulator System for Fast-greens Installation

RadiaBeam, in collaboration with UCLA and Fermilab, is developing a strongly tapered helical undulator system for the Tapering Enhanced Stimulated Superradiant Amplification experiment at 515 nm (TESSA-515). The experiment will be carried out at the FAST facility at Fermilab as a Gamma-Ray high Efficiency ENhanced Source (FAST-GREENS). The undulator system was designed by UCLA, engineered by RadiaBeam, and will be installed on the beamline at Fermilab (FNAL). The design is based on a permanent magnet Halbach scheme of four 1-meter long undulator sections; two of which have been completed and installed. The undulator period is fixed at 32 mm and the magnetic field amplitude can be tapered by tuning the gap along the interaction. Each magnet can be individually adjusted by 1 mm, offering up to 25% magnetic field tunability with a minimum gap of 5.58 mm. This paper discusses the design and engineering of the undulator system and the stage 0 installation status.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗