Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of particle size on the capture of uranium oxide colloidal particles from aqueous suspensions via high-gradient magnetic filtration

The effectiveness of High Gradient Magnetic Filtration (HGMF) in capturing uranium oxide particles from suspensions was investigated in this study. Two sets of experiments were performed to evaluate the importance of size on the capture of uranium oxide particles. The first considered two batches sieved into size bins of< 5, 5–10, 10–15, and 15–20 µm, while the second was performed using two suspensions with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm. Iron oxide experiments, with particles between 0.3 and 0.8 µm, were performed for calibration purposes. In all experiments, a surfactant (Triton-X100 or sodium dodecyl sulfate) was used to prevent particle aggregation and limit the influence of non-magnetic capture mechanisms. A magnetic field of approximately 1.1 Tesla was generated using a water cooled electromagnet. HGMF was performed using tubular filters packed with ferromagnetic stainless-steel wool. Of the initial four uranium oxide particle sizes, magnetic capture was only observed for particles with a diameter of less than 5 µm, while larger particles experienced no magnetic and minimal total capture. For particles with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm, capture efficiencies increased by 39 ± 9% and 34 ± 6% respectively, solely due to the magnetic field. Although the magnetic force is proportional to particle diameter, the capture efficiency decreased as diameter increased. So these results suggest that Brownian diffusion, which is influential for micron sized particles and increases with decreasing particle size, is acting in conjunction with the magnetic force to influence the efficacy of HGMF for uranium oxide. This important finding underscores the effectiveness of Brownian diffusion in increasing the rate of collision between particles and collector fibers. A stochastic trajectory model was developed to incorporate the influence of Brownian motion on particle behavior and filter removal efficiency. Modeling results are discussed and compared for uranium and iron oxide particles.

42 ENGINEERING↗

SrV 0.3 Fe 0.7 O 2.8 : A Vacancy-Ordered Fe-Based Perovskite Exhibiting Room-Temperature Magnetoresistance

We report room-temperature (RT) magnetoresistance (MR) in a novel Fe-based perovskite, SrV 0.3 Fe 0.7 O 2.8 . This compound contains ordered oxygen vacancies in every fifth primitive perovskite (111)p plane, leading to a layered structure consisting of triple-octahedral and double-tetrahedral layers. Along with the oxygen vacancies, the transition-metal ions are also ordered: the octahedral sites are occupied by 100% of Fe ions, while the tetrahedral sites are occupied by 25% of Fe ions and 75% of V ions. As a result, SrV 0.3 Fe 0.7 O 2.8 forms a magnetically striped lattice in which the octahedral layers with 100% of magnetic Fe ions are separated by the diluted magnetic layer. Finally, the compound exhibits weak ferromagnetism and shows a large negative MR (-5% at 3 T) at RT, despite the small saturation moment (0.4 μB/Fe atom). Thus, this type of layered compound is promising for further large MR by an increase of magnetization through chemical substitution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-fluid and kinetic transport physics of Kelvin–Helmholtz instabilities in nonuniform low-beta plasmas

Hall-magnetohydrodynamic (Hall-MHD) theory, two-fluid simulations, and kinetic simulations are used in this work to investigate the cross-field transport properties of Kelvin–Helmholtz instabilities in nonuniform low-beta collisionless plasmas. Hall-MHD analysis shows how the linear properties of the instability are modified by density gradients and magnetization. High-order accurate two-fluid and kinetic simulations, with complete dynamics of finite-mass electrons and ions, are applied to a suite of parameter cases to systematically assess the effects of diamagnetic drift, magnetization, charge separation, and finite Larmor motion. Initialization of exact two-species kinetic equilibria facilitates the study of isolated physical effects and enables detailed cross-comparisons between two-fluid and kinetic simulations, including for cases where ion gyroradii are comparable to gradient scale lengths. For nonuniform plasmas with significant space charge, the results of two-fluid and kinetic simulations are found to disagree with Hall-MHD predictions. Kelvin–Helmholtz instability growth rates, per unit shear, are shown to be smaller when ion diamagnetic drift and $E \times B$ drift are parallel and larger when the two drifts are antiparallel. The effect is attributed to polarization drift in the shear layer, which leads to redistribution of charge, alters the electric field that drives plasma advection, and consequently modifies growth rates. Instability-induced mass transport for different parameters is characterized in terms of the flux across the shear layer and a simplified diffusion model. Distribution functions from kinetic simulations are shown to deviate substantially from Maxwellian reconstructions, indicating the importance of kinetic physics during the nonlinear phase of the instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Skyrmion-skyrmionium phase separation and laning transitions via spin-orbit torque currents

Many driven binary systems can exhibit laning transitions when the two species have different mobilities, such as colloidal particles with opposite charges in electric fields. Another example is pedestrian or active-matter systems, where particles moving in opposite directions form a phase-separated state that enhances the overall mobility. In this work, we use atomistic simulations to demonstrate that mixtures of skyrmions and skyrmioniums also exhibit pattern formation and laning transitions. Skyrmions move more slowly and at a finite skyrmion Hall angle compared to skyrmioniums, which move faster and without a skyrmion Hall effect. At low drives, the system forms a partially jammed phase where the skyrmioniums are dragged by the surrounding skyrmions, resulting in a finite angle of motion for the skyrmioniums. At higher drives, the system transitions into a laned state, but unlike colloidal systems, the lanes in the skyrmion-skyrmionium mixture are tilted relative to the driving direction due to the intrinsic skyrmion Hall angle. In the laned state, the skyrmionium angle of motion is reversed when it aligns with the tilted lane structure. At even higher drives, the skyrmioniums collapse into skyrmions. Below a critical skyrmion density, both textures can move independently with few collisions, but above this density, the laning state disappears entirely, and the system transitions to a skyrmion-only state. We map out the velocity and Hall responses of the different textures and identify three distinct phases: partially jammed, laned, and skyrmion-only moving crystal states. In conclusion, we compare our results to recent observations of tilted laning phases in pedestrian flows, where chiral symmetry breaking in the particle interactions leads to similar behavior.

36 MATERIALS SCIENCE↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extending Magnetic Core Shell Nanoparticle Extraction Technology to Cesium and Antimony Removal from Geothermal Brines in New Zealand

Our industrial client (Geo40) has developed and deployed a process to remove silica from geothermal fluids and produce a high-margin specialty colloidal silica product comparable to those of market leaders. Geo40 now wishes to explore opportunities to extend their mineral extraction operations to other elements that are present in these brines. Geo40 has identified cesium (Cs) that is present in Ohaaki brines (pH ~8–8.5) at parts per million levels and could be sold to customers if it could be produced at an attractive price. With support from the Department of Energy’s (DOE’s) Geothermal Technologies Office, a simple and highly cost-effective magnetic nanofluid method for extraction of rare earth elements (REEs) from geothermal brine solutions has been developed and demonstrated at the laboratory bench scale at Pacific Northwest National Laboratory (PNNL). Core shell sorbent particles are produced using an iron oxide core particle, which is used to anchor and grow a surrounding adsorbent shell functionalized with a chelating ligand that selectively binds REEs. We extended PNNL’s work by exploring new sorbent shells that are highly selective for Cs. Uptake of Cs was measured as a function of exposure time by analyzing solution samples extracted from batch sorption tests.

15 GEOTHERMAL ENERGY↗

Magnetic Nanoparticle Extraction of Lithium from Produced Waters - CRADA 483 (Final Report)

The demand for lithium in the energy production industry is expected to increase sharply, development of simple and cost-effective techniques for lithium production and recovery from various lithium sources is essential. In this project, core/shell magnetic nanoparticles were successfully designed to selectively extract lithium from aqueous lithium sources as an extension of Pacific Northwest National Laboratory’s magnetic nanofluid extraction technology. The core/shell magnetic nanoparticles are composed of manganese oxide-based lithium ion sieve shells, which allow selective lithium uptake from brines with multiple coexisting ions, over iron oxide cores, which can respond to external magnetic fields for effective recovery and reuse of adsorbents from a liquid. The synthesized lithium ion-sieves and core/shell magnetic nanoparticles were characterized using several techniques to reveal their crystallinity and morphology. The lithium uptake properties of the lithium ion-sieves and core/shell magnetic nanoparticles were evaluated in terms of lithium adsorption capacity, removal percentage, selectivity, and cycling performance in simulated and natural brines. Magnetic properties of the core/shell magnetic nanoparticles were tested by measuring magnetic saturation, and magnetic response of colloidal solutions containing the core/shell magnetic nanoparticles was tested with permanent magnets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Fundamental Economic Assessment of Recovering Rare Earth Elements and Critical Minerals from Acid Mine Drainage Using a Network Sourcing Strategy

In recent years, acid mine drainage (AMD) has emerged as a promising unconventional source of rare earth elements (REEs) and other critical minerals (CMs) such as cobalt and manganese. In this regard, AMD provides a natural heap leaching effect that extracts and concentrates REE/CM from the host strata creating a partially enriched feedstock suitable for downstream extraction, separation, and recovery. While several prior studies have described processes and approaches for the valorization of AMD, very few have described the supply chain and infrastructure requirements as well as the associated economic assessment. To that end, this paper provides a fundamental economic assessment of REE/CM recovery from AMD using a network sourcing strategy in addition to a robust, flexible feedstock separations and refining facility. The methodology of this paper follows that of a typical techno-economic analysis with capital and operating costs estimated using AACE Class IV (FEL-2) guidelines. To demonstrate the range of possible outcomes, four pricing scenarios were modeled including contemporary prices (September, 2021) as well as the minimum and maximum prices over the last decade. In addition, five production scenarios were considered reflecting variations in the product suite, ranging from full elemental separation to magnet REE and CM production only (i.e., Pr, Nd, Tb, Dy, Y, Sc, Co, and Mn). The results of this analysis show that, with the exception of the minimum price scenario, all operational configurations have positive economic indicators with rates of return varying from 25% to 32% for the contemporary price scenario. The optimal configuration was determined to be production of Co, Mn, and all REEs except for mischmetal, which is not recovered. Sensitivity analysis and Monte Carlo simulation show that capital cost and HCl consumption are the two major factors influencing rate of return, thus indicating opportunities for future technology development and cost optimization. Implications of the study and a cooperative profit-sharing model for sourcing are also described.

42 ENGINEERING↗

Detection and Aggregation of Listeria Monocytogenes Using Polyclonal Antibody Gold-Coated Magnetic Nanoshells Surface-Enhanced Raman Spectroscopy Substrates

Magnetic nanoshells with tailored surface chemistry can enhance bacterial detection and separation technologies. This work demonstrated a simple technique to detect, capture, and aggregate bacteria with the aid of end-functionalized polyclonal antibody gold-coated magnetic nanoshells (pAb-Lis-AuMNs) as surface-enhanced Raman spectroscopy (SERS) probes. Listeria monocytogenes were used as the pathogenic bacteria and the pAb-LisAuMNs, 300 nm diameter, were used as probes allowing facile magnetic separation and aggregation. An optimized covalent bioconjugation procedure between the magnetic nanoshells and the polyclonal antibody was performed at pH six via a carbodiimide crosslinking reaction. Spectroscopic and morphological characterization techniques confirmed the fabrication of stable pAb-Lis-AuMNs. The resulting pAb-Lis-AuMNs acted as a SERS probe for L. monocytogenes based on the targeted capture via surface binding interactions and magnetically induced aggregation. Label-free SERS measurements were recorded for the minimum detectable amount of L. monocytogenes based on the SERS intensity at the 1388 cm -1 Raman shift. L. monocytogenes concentrations exhibited detection limits in the range of 10 4 –10 7 CFU ml -1 , before and after aggregation. By fitting these concentrations, the limit of detection of this method was ~10 3 CFU ml -1 . Using a low-intensity magnetic field of 35 G, pAb-LisAuMNs aggregated L. monocytogenes as demonstrated with microscopy techniques, including SEM and optical microscopy. Overall, this work presents a label-free SERS probe method comprised of a surface-modified polyclonal antibody sub-micron magnetic nanoshell structures with high sensitivity and magnetic induced separation that could lead to the fabrication of multiple single-step sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Heavy metal separations using strongly paramagnetic column packings in a nonhomogeneous magnetic field

The present invention is directed to a method for the separation of an actinide from another metal. The method comprises the following steps: (a) establishing a non-homogeneous magnetic field across a separation column containing a paramagnetic packing material and (b) providing a fluid containing the actinide and the another metal to the separation column wherein the fluid and the paramagnetic packing material are exposed to the non-homogeneous magnetic field. The non-homogeneous magnetic field is produced by a magnet having a first pole for magnetic interaction with a second pole of the magnet wherein the first pole has a different surface area than the second pole. The non-homogeneous magnetic field has a magnetic field gradient of about 500 lines/cm 2 /cm or more. In addition, the present invention is also directed to a method for the separation of one heavy metal from another heavy metal.

36 MATERIALS SCIENCE↗

Impact of globally spin-aligned vector mesons on the search for the chiral magnetic effect in heavy-ion collisions

In high-energy heavy-ion collisions, the chiral magnetic effect (CME) is predicted to arise from the interplay between the chirality imbalance of quarks in the nuclear medium and the intense magnetic field, and will cause a charge separation along the magnetic field direction. While the search for the CME is still ongoing in experiments at Relativistic Heavy Ion Collider (RHIC) and the Large Hadron Collider (LHC), the CME-sensitive observables need to be scrutinized to exclude the non-CME contributions. In this work, we examine the influence of globally spin-aligned ρ mesons on the γ 112 correlator, the R Ψ 2 (ΔS) correlator, and the signed balance functions, via a toy model and a multiphase transport model (AMPT). The global spin alignment of vector mesons could originate from non-CME mechanisms in heavy-ion collisions, and is characterized by the 00-component of the spin density matrix, ρ 00 . Here, we find that the CME observables show similar dependence on ρ 00 , and could receive a positive (negative) contribution from ρ-decay pions, if the ρ 00 of ρ mesons is larger (smaller) than 1/3. Since pions are the most abundant particles in such collisions, the ρ 00 measurements for ρ mesons become crucial to the interpretation of the CME data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of globally spin-aligned vector mesons to the measurements of the chiral magnetic effect in heavy-ion collisions

The chiral magnetic effect (CME) in high-energy heavy-ion collisions arises from the interplay between the chirality imbalance and the intense magnetic field and will cause a charge separation along the magnetic field direction. While the CME search is still ongoing in experiments, the non-CME contributions need to be excluded from the CME observables. In this work, we examine the influence of globally spin-aligned ρ mesons on the γ 112 correlator, the R Ψ 2 (ΔS) correlator, and the signed balance functions, via a toy model and a multiphase transport model (AMPT). We find that the CME observables are sensitive to the 00-component of the spin density matrix, ρ 00 : they receive positive (negative) contributions when ρ 00 is larger (smaller) than 1/3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laminated magnetic materials for on-chip magnetic inductors/transformers

A technique relates to a method of forming a laminated multilayer magnetic structure. An adhesion layer is deposited on a substrate. A magnetic seed layer is deposited on top of the adhesion layer. Magnetic layers and non-magnetic spacer layers are alternatingly deposited such that an even number of the magnetic layers is deposited while an odd number of the non-magnetic spacer layers is deposited. The odd number is one less than the even number. Every two of the magnetic layers is separated by one of the non-magnetic spacer layers. The first of the magnetic layers is deposited on the magnetic seed layer, and the magnetic layers each have a thickness less than 500 nanometers.

36 MATERIALS SCIENCE↗

Laminated magnetic materials for on-chip magnetic inductors/transformers

A technique relates to a method of forming a laminated multilayer magnetic structure. An adhesion layer is deposited on a substrate. A magnetic seed layer is deposited on top of the adhesion layer. Magnetic layers and non-magnetic spacer layers are alternatingly deposited such that an even number of the magnetic layers is deposited while an odd number of the non-magnetic spacer layers is deposited. The odd number is one less than the even number. Every two of the magnetic layers is separated by one of the non-magnetic spacer layers. The first of the magnetic layers is deposited on the magnetic seed layer, and the magnetic layers each have a thickness less than 500 nanometers.

36 MATERIALS SCIENCE↗

Escalated Phase Separation Driven Enhanced Magnetoresistance in Manganite/Iridate Epitaxial Heterostructures

Phase separation in manganites leads to unique magnetic and electronic properties. 50% Ca-doped LaMnO 3 (LCMO), at the boundary of ferromagnetic (FM) and antiferromagnetic (AFM) states in La 1-x Ca x MnO 3 (0 ≤ x ≤ 1), is an ideal system to study phase separation behavior. The investigation reveals the effect of a 5d-metal perovskite SrIrO 3 (SIO) on the phase separation, magnetic, and magnetoresistance (MR) properties of LCMO. Single-layer and bilayer LCMO films, both appear purely ferromagnetic along the in-plane (IP) magnetic field direction, but show the tendency of temperature-dependent ferromagnetic and antiferromagnetic or charge-ordered (CO) phase separation with the out-of-plane (OOP) applied field. The MR, and colossal magnetoresistance (CMR), observed in LCMO/SIO bilayers are two orders and an order of magnitude (in %) larger, respectively than that in the single-layer film. The coexistence of FM and AFM/CO phases is responsible for the CMR and MR enhancement in the LCMO/SIO bilayer, pointing toward the importance of the phase separation and competition of both the individual materials in enhancing their magnetic and electronic properties.

36 MATERIALS SCIENCE↗

The magnetic gradient scale length explains why certain plasmas require close external magnetic coils

Abstract The separation between the last closed flux surface of a plasma and the external coils that magnetically confine it is a limiting factor in the construction of fusion-capable plasma devices. This plasma-coil separation must be large enough so that components such as a breeding blanket and neutron shielding can fit between the plasma and the coils. Plasma-coil separation affects reactor size, engineering complexity, and particle loss due to field ripple. For some plasmas it can be difficult to produce the desired flux surface shaping with distant coils, and for other plasmas it is infeasible altogether. Here, we seek to understand the underlying physics that limits plasma-coil separation and explain why some configurations require close external coils. In this paper, we explore the hypothesis that the limiting plasma-coil separation is set by the shortest scale length of the magnetic field as expressed by the ∇ B tensor. We tested this hypothesis on a database of > 40 stellarator and tokamak configurations. Within this database, the coil-to-plasma distance compared to the minor radius varies by over an order of magnitude. The magnetic scale length is well correlated to the coil-to-plasma distance of actual coil designs generated using the REGCOIL method (Landreman 2017 Nucl. Fusion 57 046003). Additionally, this correlation reveals a general trend that larger plasma-coil separation is possible with a small number of field periods.

Physics↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-range magnetic order and relaxor ferroelectricity in a hexagonal high-entropy ferrite

Multiferroics that combine ferroelectricity and magnetic order are attractive for electronic and spintronic technologies, yet chemical disorder that promotes relaxor ferroelectricity usually suppresses long-range magnetic order. Here, we report entropy-stabilized relaxor multiferroicity in epitaxial hexagonal (Tb0.2Dy0.2Ho0.2Lu0.2Yb0.2)FeO3 thin films. Structural, magnetic, dielectric, and synchrotron spectroscopic measurements show the coexistence of relaxor ferroelectricity and long-range ferromagnetic order. We find that improper ferroelectricity remains robust against A-site configurational disorder, while the Fe sublattice preserves magnetic exchange. This separation of the microscopic origins of the polar and magnetic responses enables chemically disordered multiferroicity. Our results establish entropy engineering in hexagonal ferrites as a route toward multifunctional oxide thin films and provide a general design strategy for high-entropy multiferroics.

Miertschin, Duncan [Baylor University]↗