Oscillatory magnetostriction in n-gallium antimonide.
Oscillatory magnetostriction in GaSb, noting stress effect on energy bands
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Oscillatory magnetostriction in GaSb, noting stress effect on energy bands
At cryogenic temperatures, TbDy alloys exhibit giant magnetostriction, which makes these materials interesting for engineering service in cryogenics actuators, valves, and positioners.
Magnetostrictive actuators based on TbDy alloys show promise for use as actuators on cryogenic devices. They can be made to deliver large forces and useful displacements below liquid nitrogen temperatures, with many advantages over piezoelectric actuators or motion feedthroughs from higher temperature actuators.
Motivated by the possibility of enhanced magnetic fluctuations in exfoliated α-RuCl 3 flakes, we study magneto-Raman spectra of exfoliated multilayer α-RuCl 3 in out-of-plane magnetic fields of -6 to 6 T at temperatures of 670 mK to 4 K. While the literature currently suggests that bulk α-RuCl 3 is in an antiferromagnetic zigzag phase with R$\bar3$ symmetry at low temperatures, we do not observe R$\bar3$ symmetry in exfoliated α-RuCl 3 at low temperatures. While we saw no magnetic field-driven transitions, the Raman modes exhibit unexpected stochastic shifts in response to the applied magnetic field that are above the uncertainties inferred from Bayesian analysis. Finally, these stochastic shifts are consistent with the emergence of magnetostrictive interactions in exfoliated α-RuCl 3 .
The magnetoelectric behavior of epitaxial Fe–Ga microstructures on top of a (001)-oriented PMN–PT piezoelectric substrate is imaged with magnetic X-ray microscopy. Additionally, the micron-scale strain distribution in PMN–PT is characterized by X-ray microdiffraction and examined with respect to the results of the Fe–Ga magnetoelectric switching. The magnetic reorientation of Fe–Ga is found to be strongly correlated with size, shape, and crystallographic orientation of the microstructures. In the case of square-shaped structures, size dictates the influence of the strain distribution on both the initialization of the ground state and on the magnetic reorientation during application of voltage. On the other hand, elliptical microstructures demonstrate completely different magnetic responses depending on the relative orientation of their long axis with respect to the crystallographic directions of the PMN–PT. This study demonstrates that engineering the behavior of highly magnetostrictive epitaxial microdevices is possible. It further elucidates that voltage-induced actuation can be largely tuned to achieve the desired type of magnetic switching ranging from vortex circulation reversal, domain wall motion, to a large rotation of magnetization. Because of the outstanding properties of the investigated material system, the reported findings are expected to be of great interest for the realization of next-generation energy-efficient magnetic memory and logic devices.
Oscillatory transverse and longitudinal magnetostriction in single crystal Bi, obtaining deformation potentials
Oscillations of longitudinal magnetostriction in silver and copper single crystals at low temperature
Phase transitions and magnetostriction in CsMnCl3-2H2O
Magnetostriction in hydrated cesium manganese chloride, examining dimensional changes as function of magnetic field and temperature through antiferromagnetic, spin flopped and paramagnetic phases
Magnetostriction in antiferromagnetic, spin flopped and paramagnetic phases of hydrated cesium manganese trichloride, studying volume changes and thermal expansion near phase transition
A detailed experimental and theoretical study of quantum oscillations in the magnetostriction and Young's modulus of p-PbTe is presented. The valance band of PbTe is approximated by a spheroidal, nonparabolic model in which the effects of strain on the valance band parameters are described by a deformation potential model. Using appropriate thermodynamic derivatives of the modified Lifshitz-Kosevich expression for the oscillatory parts of the electronic free energy, it is shown that both types of oscillations arise mainly from relative shifts of the valance band maxima due to shear strains, accompanied by intervalley charge transfer. Band parameters derived from the periods, phases, and spin splitting of the oscillations are in generally good agreement with values reported by other workers. A detailed comparison is made of the experimentally observed oscillation amplitudes with those predicted by theory, and satisfactory agreement is found. The ratio of the amplitudes of the two effects yields a value of the valance band deformation potential in good agreement with a value found from piezoresistance experiments by Burke.
Device requires no moving parts and has less stringent tolerances. Device uses magnetostrictive powdered metal and electromagnets, rather than solenoid. Device is more reliable than conventional valves.
A new rare earth alloy, Terfenol-D, combines low frequency operation and extremely high energy density with high magnetostriction. Its material properties make it suitable as a drive element for actuators requiring high output torque. The high strains, the high forces and the high controllability of Terfenol alloys provide a powerful and challenging basis for new ways to generate motion in actuators. Two prototypes of motors using Terfenol-D rods were developed at NASA Goddard. The basic principles of operation are provided of the motor along with other relevant details. A conceptual design of a torque limiting safety clutch/brake under development is illustrated. Also, preliminary design drawings of a linear actuator using Terfenol-D is shown.
Linear-translation motors containing magnetostrictive actuator elements proposed for use in making fine position adjustments on scientific instruments at temperatures from near absolute zero to room temperature. Actuators produce small increments of linear motion and operate in "set-and-forget" mode in sense they automatically lock themselves against motion when power not applied. Do not consume or dissipate power when stationary. Proposed linear-translation motors also made to produce large maximum displacements.
A major limitation in use of electromagnetic and/or magnetomechanical models for design of Terfenol-D actuators is the lack of reliable material property data for Terfenol-D. In particular data on the performance of Terfenol-D as employed in a transducer, operating under real world dynamic conditions is needed. To provide this information, Terfenol-D rod properties need to be measured under as run prestressed and magnetically biased states. Using a Terfenol-D actuator, the following properties can be measured and/or calculated: mechanical quality factor, speed of sound in the material, the resonant frequency, the anti-resonant frequency, two magnetic permeabilities (one at constant stress and one at constant strain), two Young's moduli (one at constant amplitude applied magnetic field and one at constant amplitude magnetic flux density in the material), the magnetomechanical coupling, and the axial strain coefficient. The development of the material properties measurements and calculations is based on the model of low signal, linear, magnetostriction from Clark, the linear transduction equations for a transducer from Hunt, and a one degree of freedom mechanical model of the transducer. The electrical impedance and admittance mobility loops are used to determine the resonant, anti-resonant, and half power point frequencies. The rest of the material properties indicated above can then be calculated using these frequencies, acceleration from an accelerometer mounted on the actuator arm, and readily measurable transducer and Terfenol-D rod parameters.
The use of the magnetostrictive material Terfenol-D as a motion source in active vibration control (AVC) systems are being studied. Currently it is of limited use due to the nonlinear nature of the strain versus magnetization curve and the magnetic hysteresis in the Terfenol-D. One manifestation of these nonlinearities is waveform distortion in the output velocity of the transducer. For Terfenol-D to be used in ever greater numbers of AVC systems, these nonlinearities must be addressed. In this study the nonlinearities are treated as disturbances to a linear system. The acceleration output is used in simple analog and digital feedback control schemes to improve linearity of the transducer. In addition, the use of a Terfenol-D actuator in an AVC system is verified. Both analog and digital controllers are implemented and results compared. A cantilever beam system is considered for AVC applications. The second thrust of this presentation is the reduction of harmonic distortions. Two conclusions can be reached from this work. One, the linearization of Terfenol-D transducers is possible with the use of feedback controllers, both digital and analog. Second, Terfenol-D is a viable motion source in active vibration control systems utilizing either analog or digital controllers.
This paper addresses the development of a nonlinear optimal control methodology for magnetostrictive actuators. At moderate to high drive levels, the output from these actuators is highly nonlinear and contains significant magnetic and magnetomechanical hysteresis. These dynamics must be accommodated by models and control laws to utilize the full capabilities of the actuators. A characterization based upon ferromagnetic mean field theory provides a model which accurately quantifies both transient and steady state actuator dynamics under a variety of operating conditions. The control method consists of a linear perturbation feedback law used in combination with an optimal open loop nonlinear control. The nonlinear control incorporates the hysteresis and nonlinearities inherent to the transducer and can be computed offline. The feedback control is constructed through linearization of the perturbed system about the optimal system and is efficient for online implementation. As demonstrated through numerical examples, the combined hybrid control is robust and can be readily implemented in linear PDE-based structural models.
We developed a superfluid leak tight low temperature valve that can be activated by a magnetostrictive material.