Search NASA⌕ Search

SEARCH · Search NASA

Results for “mars landers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dielectric properties of Mars' surface: Proposed measurement on a Mars lander

Recent studies of missions to Mars (MESUR by NASA and Marsnet by ESA) have suggested the development of semihard landers. One type was to be extremely basic, consisting mainly of a meteorological package, but with the possibility of other small, low-mass, low-power instruments. In particular, this type of lander was also considered for the exploration of the polar regions. Two methods to investigate the surface material at the landing site are discussed. Both measure the dielectric constant epsilon of the ground material. This information can then be used to elucidate the surface composition and structure. The determination of the permittivity would be of high scientific value, especially in the case of a landing on the polar ice.

Ulamec, S.↗

Development of the Viking Mars lander thermal control subsystem design

Two Viking spacecraft, each consisting of a lander capsule coupled to an orbiter, will be launched toward Mars during the summer of 1975. About a year later, the orbiters will go into orbit around Mars and the landers will descend to the surface for 90-day landed missions. The lander must withstand a wide variety of environmental and operational conditions during all phases of the mission, including prelaunch sterilization. On the surface of Mars, the lander internal temperatures must be controlled under widely varying thermal environments and atmospheric conditions. The lander thermal design is based on the maximum use of passive techniques and is integrated into the overall vehicle design and operation. The solutions to the unusual combinations of design problems and a summary of the results of full scale model testing under simulated mission conditions are presented.

Morey, T. F.↗

Next-Generation Entry/Descent/Landing System for Mars Landers

Many important scientific objectives for Mars exploration require the ability to land safely at select sites. The 'first-generation' entry, descent, and landing (EDL) systems used in previous missions imposed limitations on target site selection due to the delivery accuracy achievable and those systems' inability to recognize and avoid hazardous terrain. This abstract outlines key capabilities of a proposed second-generation EDL system, currently under development by a consortium of NASA centers, Industry, and academic institutions.

Thurman, Sam W.↗

Integrated Precision Landing Performance and Technology Assessments of a Human-Scale Mars Lander Using a Generalized Simulation Framework

Human-scale missions to Mars will likely require multiple landers delivered precisely to designated locations. The current NASA human Mars reference architecture assumes delivery of three 25 t payloads from a 1- or 5-Sol orbit to the surface with a landing precision of 50 m to ensure logistics are located near the habitat. While initial navigation estimates improve with on-orbit ground tracking, errors increase during post-deorbit coast. Likewise, Mars atmospheric variability and forecasting uncertainty means that the entry vehicle guidance, navigation, and control systems must be robust to accommodate landing during any time of day or Mars year, including during dust storms. Precision landing technologies are currently being assessed to determine if onboard navigation sensors are sufficient to enable the landing accuracy required or if additional navigation aids such as surface or orbiting beacons will be needed. This study evaluates the system performance requirements to meet the desired landing accuracy for the reference vehicle design and entry, descent, and landing concept of operations. A detailed six degree-of-freedom integrated performance simulation framework is used to perform the assessment and demonstrate that under current assumptions, onboard navigation sensors are sufficient to support precision landing.

spacecraft navigation↗

Integrated Precision Landing Performance and Technology Assessments of a Human- Scale Mars Lander Using a Generalized Simulation Framework

Human-scale missions to Mars will likely require multiple landers delivered precisely to designated locations. The current NASA human Mars reference architecture assumes delivery of three 25 t payloads from a 1- or 5-Sol orbit to the surface with a landing precision of 50 m to ensure logistics are located near the habitat. While initial navigation estimates improve with on-orbit ground tracking, errors increase during post-deorbit coast. Likewise, Mars atmospheric variability and forecasting uncertainty means that the entry vehicle guidance, navigation, and control systems must be robust to accommodate landing during any time of day or Mars year, including during dust storms. Precision landing technologies are currently being assessed to determine if onboard navigation sensors are sufficient to enable the landing accuracy required or if additional navigation aids such as surface or orbiting beacons will be needed. This study evaluates the system performance requirements to meet the desired landing accuracy for the reference vehicle design and entry, descent, and landing concept of operations. A detailed six degree-of-freedom integrated performance simulation framework is used to perform the assessment and demonstrate that under current assumptions, onboard navigation sensors are sufficient to support precision landing.

Chen, Po-Ting↗

Mass Spectrometry on Future Mars Landers

Mass spectrometry investigations on the 2011 Mars Science Laboratory (MSL) and the 2018 ExoMars missions will address core science objectives related to the potential habitability of their landing site environments and more generally the near-surface organic inventory of Mars. The analysis of complex solid samples by mass spectrometry is a well-known approach that can provide a broad and sensitive survey of organic and inorganic compounds as well as supportive data for mineralogical analysis. The science value of such compositional information is maximized when one appreciates the particular opportunities and limitations of in situ analysis with resource-constrained instrumentation in the context of a complete science payload and applied to materials found in a particular environment. The Sample Analysis at Mars (SAM) investigation on MSL and the Mars Organic Molecule Analyzer (MOMA) investigation on ExoMars will thus benefit from and inform broad-based analog field site work linked to the Mars environments where such analysis will occur.

Brinckerhoff, W. B.↗

Mission and Design Sensitivities for Human Mars Landers Using Hypersonic Inflatable Aerodynamic Decelerators

Landing humans on Mars is one of NASA's long term goals. NASA's Evolvable Mars Campaign (EMC) is focused on evaluating architectural trade options to define the capabilities and elements needed to sustain human presence on the surface of Mars. The EMC study teams have considered a variety of in-space propulsion options and surface mission options. Understanding how these choices affect the performance of the lander will allow a balanced optimization of this complex system of systems problem. This paper presents the effects of mission and vehicle design options on lander mass and performance. Beginning with Earth launch, options include fairing size assumptions, co-manifesting elements with the lander, and Earth-Moon vicinity operations. Capturing into Mars orbit using either aerocapture or propulsive capture is assessed. For entry, descent, and landing both storable as well as oxygen and methane propellant combinations are considered, engine thrust level is assessed, and sensitivity to landed payload mass is presented. This paper focuses on lander designs using the Hypersonic Inflatable Aerodynamic Decelerators, one of several entry system technologies currently considered for human missions.

Polsgrove, Tara P.↗

Hydrophobic Surfaces of Spacecraft Components Enhance the Aggregation of Microorganisms and May Lead to Higher Survival Rates of Bacteria on Mars Landers

In order to minimize the forward contamination of Mars, spacecraft are assembled under cleanroom conditions that require several procedures to clean and sterilize components. Surface characteristics of spacecraft materials may contribute to microbial survival on the surface of Mars by protecting spores from sterilizing agents, including UV irradiation. The primary objective of this study was to evaluate the effects of surface characteristics of several spacecraft materials on the survival of Bacillus subtilis spores under simulated Martian conditions.

Schuerger, Andrew C.↗

Thermal Infrared Spectroscopy from Mars Landers and Rovers: A New Angle on Remote Sensing

The MINUTES instrument of the Athena Precursor Experiment (APEX) on the Mars Surveyor 2001 lander mission will perform the first thermal infrared remote sensing observations from the surface of another planet. Experience gained from this experiment will be used to guide observations from identical instruments mounted on the Athena rovers, to be launched in 2003 and 2005. The utility of infrared spectrometers in determining the mineralogic composition of geologic surfaces from airborne and spaceborne platforms has been amply demonstrated. However, relatively little experience exists in using functionally similar instruments on the ground in the context of planetary science. What work has been done on this problem has mostly utilized field spectrometers that are designed to look down on nearby target rocks. While many Mini-TES observations will be made with this type of geometry, it is likely that other observations will be made looking horizontally at the more vertically-oriented facets of rock targets, to avoid spectral contamination from dust mantles. On rover missions, the Mini-TES may also be pointed horizontally at rocks several meters away, to determine if they are worthy of approaching for in situ observations and possible sample cacheing. While these observations will undoubtedly prove useful, there are important, and perhaps unappreciated, differences between horizontal-viewing, surface-based spectroscopy and the more traditional nadir-viewing, orbit or aircraft-based observations. Plans also exist to step the Mini-TES in a rastering motion to build hyperspectral scenes. Horizontal viewing hyperspectral cubes also possess unique qualities that call for innovative analysis techniques. The effect of viewing geometry: In thermal emission spectroscopy, regardless of whether an instrument is looking down on or horizontally at a target, the same basic equation governs the radiance reaching the sensor .

Moersch, J.↗

The Viking Mars lander camera

The 7.3 kg cameras for the 1976 Viking Mars expedition feature an array of 12 silicon photodiodes, including six spectral bands for color and near-infrared imaging with an angular resolution of 0.12 deg and four focus steps for broadband imaging, with an improved angular resolution of 0.04 deg. The field of view in elevation ranges from 40 deg above to 60 deg below the horizon, and in azimuth ranges to 342.5 deg. The cameras are mounted 0.8 m apart to provide a stereo view of the area accessible to a surface sampler for biological and chemical investigations. The scanning rates are synchronized to the lander data transmission rates of 16000 bits per sec to the Viking orbiters as relay stations and 250 bits per sec directly to earth. However, image data can also be stored on a lander tape recorder. About 10 million bits of image data will be transmitted during most days of the 60-day-long mission planned for each lander.

Huck, F. O.↗

Detection of metabolically produced labeled gas - The Viking Mars Lander.

A qualitative, nonspecific method will test for life on Mars in 1976 by supplying radioactive substrates to samples of the planetary surface material. If microorganisms are present, they may assimilate one or more of the simple labeled compounds and produce radioactive gas. The compounds have been selected on the basis of biological theory and terrestrial results. The measurement of radioactive gas evolved as a function of time constitutes evidence for life. A control performed on a duplicate, but heat sterilized, sample will confirm the biological nature of the results. The shape of the response curve obtained from the viable sample may provide information on the physiological state and generation period of the organisms. Data obtained from a wide variety of terrestrial soils demonstrate a rapid response and high sensitivity for the experiment. Its ability to make comparative studies of soil microorganisms is also demonstrated.

Levin, G. V.↗

Precision Landing Navigation Performance of Human-Scale Lunar and Mars Landers

To meet the unique challenges of crewed Lunar and Mars precision landings, NASA’s Safe and Precise Landing Integrated Capabilities Evolution project has worked to advance autonomous spacecraft navigation by increasing the technology readiness level of key deorbit, entry, descent, and landing systems, including navigation sensors. Different sensors and their effects on overall system performance are evaluated using six-degree-of-freedom simulations with physics-based engineering models that capture the relevant vehicle systems and environmental effects. Building on an existing simulation framework, this work demonstrates how improved modeling fidelity enables rapid and detailed assessment of various navigation sensors on human-scale Lunar and Mars landing vehicles using NASA reference architectures.

navigation↗

Atmospheric impacts on EDL maneuver targeting for the InSight mission and unguided Mars landers

Early in operational testing for the InSight mission to Mars, it was discovered that the final maneuver to target the entry-interface point (EIP) was unexpectedly sensitive, in both magnitude and direction, to planned atmosphere model updates that would be based on real-time measurements of the Martian atmosphere by Mars Reconnaissance Orbiter (MRO). Upon investigation, the team realized that the Phoenix mission also discovered this sensitivity during its operational testing. A further investigation identified that maneuver sensitivity to real-time atmosphere updates was a result of the fact that both the EFPA and ground target were being held fixed, constraining the maneuver in a way that forced the entry time to change in order to compensate for changes to the nominal trajectory from updating the atmosphere model. The final maneuver occurs 22 hours prior to entry, at which point it is very expensive to change entry time. The study also revealed that any unguided Mars entry, descent, and landing (EDL) mission would be impacted by this sensitivity if it used real-time atmosphere observations to model the nominal expected atmosphere used for maneuver targeting of the EIP. This paper discusses the results of that investigation and presents a number of mitigations as well as the consequences of ignoring the sensitivity.

Kipp, Devin↗