Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Determination of the area and mass distribution of orbital debris fragments

An important factor in modeling the orbital debris environment is the loss rate of debris due to atmospheric drag and lunisolar perturbations. An accurate knowledge of the area-to-mass ratio of debris fragments is required to calculate the effects of atmospheric drag. It is shown here that the orbital elements as a function of time can be used to invert any propagation algorithm to yield the area-to-mass ratio of an orbiting object. From these calculations and the observed radar cross-section of the object, the mass can be calculated to an accuracy of about 30 percent. It is shown that the mass is related to the effective cross-section area by a power-law relation, but for a given area the mass distribution is very broad. An expression is given for the cumulative mass distribution.

Badhwar, G. D.↗

The ultraviolet excess of luminous quasars. II - Evidence for massive accretion disks

This paper presents new infrared, optical, and ultraviolet spectra of three high-redshift quasars. They are analyzed along with three published quasar spectra. After accounting for other sources of radiation, the continua are fitted with spectra predicted for optically thick steady-state accretion disks which include the effects of general relativity. The two fitting parameters, the mass of the accreting black hole and the accretion rate, are determined by the data with a formal accuracy of 20 percent. The masses range from 0.2-0.5 billion solar mass for 3C 273 and PKS 0405-123 to 1-3 billion solar masses for the high-redshift quasars. The values depend on the assumed disk inclination and the angular momentum of the hole. The high luminosities of these six quasars are all within a factor of 2 of their Eddington limits, and this conclusion is not extremely sensitive to the modeling assumptions.

Malkan, M. A.↗

Preliminary feasibility study of a multi-Phobos encounter experiment during the Viking extended mission

The Viking '75 Mission to Mars is reported which permits a truly unique opportunity to explore the natural satellite, Phobos, from distances measured in tens of kilometers. A preliminary feasibility study has been made which shows that a science mission involving a Phobos close encounter is technically feasible and within the capabilities of the current Viking design. For less than 20 m/s, the Viking Orbiter can provide approximately two 40-day periods of close observation of Phobos, with the first encounter period in January and the second in March, 1977. Multi-pass images of the entire satellite from nearly all aspect angles and with resolution on the order of 10 meters are possible. Close encounters will permit mass determinations to an accuracy of tens of percent. These experiments can be performed in series with the nominal mission; thus, providing complementary scientific information without compromising the original mission and science objectives.

Tolson, R. H.↗

A study of the reflection effect in close spectroscopic binary stars

Four W Ursae Majoris-type binaries were investigated using the simple model of blackbody solid spheres. Numerical computations were carried out for the rotationally broadened profiles of spectral lines Sr II (4077.7) and Ca I (4226.7) and the mean radial velocities. These mean velocities at different phases outside eclipses were compared with sinusoidal values of the radial velocity curve for point masses. Within the present accuracy of observations, the reflection effect is small and may be neglected in the analysis of radial velocity curves.

Chen, K.-Y.↗

Phobos and Deimos encounter experiment during the Viking extended mission

The Viking '75 Mission to Mars permits a truly unique opportunity to explore the natural satellites, Phobos and Deimos, from distances measured in the tens of kilometers. Because of the particular orbital geometry currently planned for the Viking Mission, the Viking spacecraft can be maneuvered to make repeated passes very close to Phobos and Deimos during the proposed extended mission phase. Multipass images of both satellites will cover approximately 75% of Phobos and 50% of Deimos. Resolution on the order of 50 meters is possible. Close encounters will permit mass determination to an accuracy of tens of percent. A preliminary feasibility study has been made which shows that the propulsive requirements are nominal, the orbit determination accuracy is adequate, and the satellites are within the scan platform pointing capability during portions of each encounter.

Tolson, R. H.↗

Numerical study of supersonic combustors by multi-block grids with mismatched interfaces

A three dimensional, finite rate chemistry, Navier-Stokes code was extended to a multi-block code with mismatched interface for practical calculations of supersonic combustors. To ensure global conservation, a conservative algorithm was used for the treatment of mismatched interfaces. The extended code was checked against one test case, i.e., a generic supersonic combustor with transverse fuel injection, examining solution accuracy, convergence, and local mass flux error. After testing, the code was used to simulate the chemically reacting flow fields in a scramjet combustor with parallel fuel injectors (unswept and swept ramps). Computational results were compared with experimental shadowgraph and pressure measurements. Fuel-air mixing characteristics of the unswept and swept ramps were compared and investigated.

Moon, Young J.↗

Numerical study of supersonic combustors by multi-block grids with mismatched interfaces

A three-dimensional, finite-rate chemistry, Navier-Stokes code has been extended to a multi-block with mismatched interface code for practical calculations of supersonic combustors. To ensure global conservation, a conservative algorithm was used for the treatment of mismatched interfaces. The extended code was checked against one test case, i.e., a generic supersonic combustor with transverse fuel injection, examining solution accuracy, convergence, and local mass flux error. After testing, the code was used to simulate the chemically reacting flow fields in a scramjet combustor with parallel fuel injectors (unswept and swept ramps). Computational results were compared with experimental shadowgraph and pressure measurements. Fuel-air mixing characteristics of the unswept and swept ramps were compared and investigated.

Moon, Young J.↗

Fabrication Of High-Tc Superconducting Integrated Circuits

Microwave ring resonator fabricated to demonstrate process for fabrication of passive integrated circuits containing high-transition-temperature superconductors. Superconductors increase efficiencies of communication systems, particularly microwave communication systems, by reducing ohmic losses and dispersion of signals. Used to reduce sizes and masses and increase aiming accuracies and tracking speeds of millimeter-wavelength, electronically steerable antennas. High-Tc superconductors preferable for such applications because they operate at higher temperatures than low-Tc superconductors do, therefore, refrigeration systems needed to maintain superconductivity designed smaller and lighter and to consume less power.

Bhasin, Kul B.↗

The Mars Observer laser altimeter investigation

The primary objective of the Mars Observer laser altimeter (MOLA) investigation is to determine globally the topography of Mars at a level suitable for addressing problems in geology and geophysics. Secondary objectives are to characterize the 1064-nm wavelength surface reflectivity of Mars to contribute to analyses of global surface mineralogy and seasonal albedo changes, to assist in addressing problems in atmospheric circulation, and to provide geodetic control and topographic context for the assessment of possible future Mars landing sites. The principal components of MOLA are a diode-pumped, neodymium-doped yttrium aluminum garnet laser transmitter that emits 1064-nm wavelength laser pulses, a 0.5-m-diameter telescope, a silicon avalanche photodiode detector, and a time interval unit with 10-ns resolution. MOLA will provide measurements of the topography of Mars within approximately 160-m footprints and a center-to-center along-track foot print spacing of 300 m along the Mars Observer subspacecraft ground track. The elevation measurements will be quantized with 1.5 m vertical resolution before correction for orbit- and pointing induced errors. MOLA profiles will be assembled into a global 0.2 deg x 0.2 deg grid that will be referenced to Mars' center of mass with an absolute accuracy of approximately 30 m. Other data products will include a global grid of topographic gradients, corrected individual profiles, and a global 0.2 deg x 0.2 deg grid of 1064-nm surface reflectivity.

Zuber, M. T.↗

An Accurate Potential Energy Surface for H2O

We have carried out extensive high quality ab initio electronic structure calculations of the ground state potential energy surface (PES) and dipole moment function (DMF) for H2O. A small adjustment is made to the PES to improve the agreement of line positions from theory and experiment. The theoretical line positions are obtained from variational ro-vibrational calculations using the exact kinetic energy operator. For the lines being fitted, the root-mean-square error was reduced from 6.9 to 0.08 /cm. We were then able to match 30,092 of the 30,117 lines from the HITRAN 96 data base to theoretical lines, and 80% of the line positions differed less than 0.1 /cm. About 3% of the line positions in the experimental data base appear to be incorrect. Theory predicts the existence of many additional weak lines with intensities above the cutoff used in the data base. To obtain results of similar accuracy for HDO, a mass dependent correction to the PH is introduced and is parameterized by simultaneously fitting line positions for HDO and D2O. The mass dependent PH has good predictive value for T2O and HTO. Nonadiabatic effects are not explicitly included. Line strengths for vibrational bands summed over rotational levels usually agree well between theory and experiment, but individual line strengths can differ greatly. A high temperature line list containing about 380 million lines has been generated using the present PES and DMF

Schwenke, David W.↗

Initial Measurement of the Vapor Pressures of Simple Refractory Materials: Cu and Fe

It has become increasingly clear over the past decade that high temperature processes played important roles in the Primitive Solar Nebula. Unfortunately, basic data, such as the vapor pressures of iron or SiO have not been measured over the appropriate temperature range (near T approximately equal to 2000K), but must be extrapolated from lower temperature measurements often made more than 50 years ago. The extrapolation of the available data to higher temperatures can be quite complex and can depend on other factors such as the oxygen fugacity or the presence of hydrogen gas. Moreover, modern technology has made possible more accurate measurements of such quantities over a wider temperature range. We recently acquired a commercial Thermo-Cahn Thermogravimetric system capable of vacuum operation to 1700 C and measurement of mass change with microgram accuracy in a 100g sample or smaller. In this paper, we will report our progress in learning to make vapor pressure measurements using this system.

Nuth, Joseph A., III↗

[Real time 3D echocardiography]

Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.

Review↗

Too Little, Too Late: How the Tidal Evolution of Hot Jupiters Affects Transit Surveys of Clusters

The tidal evolution of hot Jupiters may change the efficiency of transit surveys of stellar clusters. The orbital decay that hot Jupiters suffer may result in their destruction, leaving fewer transiting planets in older clusters. We calculate the impact tidal evolution has for different assumed stellar populations, including that of 47 Tuc, a globular cluster that was the focus of an intense HST search for transits. We find that in older clusters one expects to detect fewer transiting planets by a factor of two for surveys sensitive to Jupiter-like planets in orbits out to 0.5 AU, and up to a factor of 25 for surveys sensitive to Jupiter-like planets in orbits out to 0.08 AU. Additionally, tidal evolution affects the distribution of transiting planets as a function of semi-major axis, producing larger orbital period gaps for transiting planets as the age of the cluster increases. Tidal evolution can explain the lack of detected exoplanets in 47 Tuc without invoking other mechanisms. Four open clusters residing within the Kepler fields of view have ages that span 0.4-8 Gyr-if Kepler can observe a significant number of planets in these clusters, it will provide key tests for our tidal evolution hypothesis. Finally, our results suggest that observers wishing to discover transiting planets in clusters must have sufficient accuracy to detect lower mass planets, search larger numbers of cluster members, or have longer observation windows to be confident that a significant number of transits will occur for a population of stars.

Debes, John H.↗

Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K‐Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some μg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example, variable vacuum pressure), and c) the ablation is made with hundreds of successive laser pulses. In this work, we aim to understand the effects that occur on LIBS spectra when a homogeneous rock or a mineral is ablated under high vacuum. Understanding these effects is important to define best practices for LIBS measurements and may lead to improved measurement (or possibly prediction) of the ablated volume. We will describe our laboratory approach and first results, and discuss its utility for situ absolute geochronology campaigns.

Devismes, D.↗

Temperature Stability in the Sub-milliHertz Band With Lisa Pathfinder

LISA Pathfinder (LPF) was a technology pioneering mission designed to test key technologies required for gravitational wave detection in space. In the low frequency regime (milliHertz and below), where space-based gravitational wave observatories will operate, temperature fluctuations play a crucial role since they can couple into the interferometric measurement and the test masses’ free-fall accuracy in many ways. A dedicated temperature measurement subsystem, with noise levels in 10 μKHz −1/2 down to 1 mHz was part of the diagnostics unit onboard LPF. In this paper we report on the temperature measurements throughout mission operations, characterize the thermal environment, estimate transfer functions between different locations, and report temperature stability (and its time evolution) at frequencies as low as 10 μHz, where typically values around 1KHz −1/2 were measured.

gravitational waves↗

Measuring and Utilizing Gravity-Gradient Induced Torques on Future Gravity Recovery Missions

This research is a novel investigation into the use of newly-available relative angular acceleration measurements between a spacecraft utilized for gravity recovery missions and an internally located test mass. The gravity-gradient torque equation for zonal spherical harmonic order n is formulated for a known gravitational potential field, and through simulations it is proven that the Simplified-Gravitational Reference Sensor will be sensitive to the gravity-gradient induced torques acting on its test mass. The full conference paper will demonstrate how the presented gravity-gradient torque equation and the measured relative angular acceleration between the spacecraft and test mass will improve the accuracy of the gravity field models acquired by future gravity recovery missions by directly measuring the drag acting on the spacecraft with a single accelerometer.

gravity recovery↗

Quantitative Electron Probe Microanalysis: State of the Art

Quantitative electron-probe microanalysis (EPMA) has improved due to better instrument design and X-ray correction methods. Design improvement of the electron column and X-ray spectrometer has resulted in measurement precision that exceeds analytical accuracy. Wavelength-dispersive spectrometer (WDS) have layered-dispersive diffraction crystals with improved light-element sensitivity. Newer energy-dispersive spectrometers (EDS) have Si-drift detector elements, thin window designs, and digital processing electronics with X-ray throughput approaching that of WDS Systems. Using these systems, digital X-ray mapping coupled with spectrum imaging is a powerful compositional mapping tool. Improvements in analytical accuracy are due to better X-ray correction algorithms, mass absorption coefficient data sets,and analysis method for complex geometries. ZAF algorithms have ban superceded by Phi(pz) algorithms that better model the depth distribution of primary X-ray production. Complex thin film and particle geometries are treated using Phi(pz) algorithms, end results agree well with Monte Carlo simulations. For geological materials, X-ray absorption dominates the corretions end depends on the accuracy of mass absorption coefficient (MAC) data sets. However, few MACs have been experimentally measured, and the use of fitted coefficients continues due to general success of the analytical technique. A polynomial formulation of the Bence-Albec alpha-factor technique, calibrated using Phi(pz) algorithms, is used to critically evaluate accuracy issues and can be also be used for high 2% relative and is limited by measurement precision for ideal cases, but for many elements the analytical accuracy is unproven. The EPMA technique has improved to the point where it is frequently used instead of the petrogaphic microscope for reconnaissance work. Examples of stagnant research areas are: WDS detector design characterization of calibration standards, and the need for more complete treatment of the continuum X-ray fluorescence correction.

Carpernter, P. K.↗