Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Pre-He White Dwarfs in Eclipsing Binaries. I. WASP 0131+28

We report the first BV light curves and high-resolution spectra of the post-mass transfer binary star WASP 0131+28 to study the absolute properties of extremely low-mass white dwarfs. From the observed spectra, the double-lined radial velocities were derived, and the effective temperature and rotational velocity of the brighter, more massive primary were found to be T{sub eff,1}=10,000±200 K and v{sub 1}sin i = 55 ± 10 km s{sup −1}, respectively. The combined analysis of the Transiting Exoplanet Survey Satellite (TESS) archive data and ours yielded the accurate fundamental parameters of the program target. The masses were derived to about 1.0% accuracy and the radii to 0.6%, or better. The secondary component's parameters of M{sub 2}=0.200±0.002 M{sub ⊙}, R{sub 2}=0.528±0.003 R{sub ⊙}, T{sub eff,2} = 11,186 ± 235 K, and L{sub 2}=3.9±0.3 L{sub ⊙} are in excellent agreement with the evolutionary sequence for a helium-core white dwarf of mass 0.203 M{sub ⊙}, and indicates that this star is halfway through the constant luminosity phase. The results presented in this article demonstrate that WASP 0131+28 is an EL CVn eclipsing binary in a thin disk, which is formed from the stable Roche-lobe overflow channel and composed of a main-sequence dwarf with a spectral type A0 and a pre-He white dwarf.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative x ray phase contrast imaging of oblique shock wave–interface interactions

Oblique shock wave–interface interactions of gases and liquids have been extensively studied in shock tubes using optical methods to measure equation-of-state (EOS) parameters. However, this is difficult with solids due to their opaqueness to visible light. X ray phase contrast imaging (XPCI) has the penetrative strength to probe solids while still being sensitive to mass density and enhancing the visibility of material boundaries. We investigate the accuracy and repeatability of measuring the mean value of the average mass density (areal density divided by thickness) over region S (B S ) and flow deflection angle (θ) from XPCI images of a sample. To that end, a Hough transform-based method for measuring θ is developed. To measure B S , the XPCI image intensity probability density function (PDF) is modeled accounting for the spatial distribution of x ray energy, scintillator response, and pulse-to-pulse variation in the x ray intensity. In addition, a Monte Carlo-based algorithm for computing the B S PDF is developed. Both methods are validated on an impact-generated oblique shock wave interacting at a solid polymer-to-polymer interface. Furthermore this is accomplished through a comparison to hydrodynamic simulations using well-established EOS. Under the modeling framework for the XPCI image intensity, B S is computed with an accuracy of < 0.1% and precision of 3%–5%, while θ has an uncertainty of 0.2°, respectively. This shows that the XPCI-based model that is developed here could be an invaluable tool for high-fidelity testing of hydrodynamic models in shock polar configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying local and global mass balance errors in physics-informed neural networks

Physics-informed neural networks (PINN) have recently become attractive for solving partial differential equations (PDEs) that describe physics laws. By including PDE-based loss functions, physics laws such as mass balance are enforced softly in PINN. This paper investigates how mass balance constraints are satisfied when PINN is used to solve the resulting PDEs. We investigate PINN’s ability to solve the 1D saturated groundwater flow equations (diffusion equations) for homogeneous and heterogeneous media and evaluate the local and global mass balance errors. We compare the obtained PINN’s solution and associated mass balance errors against a two-point finite volume numerical method and the corresponding analytical solution. We also evaluate the accuracy of PINN in solving the 1D saturated groundwater flow equation with and without incorporating hydraulic heads as training data. We demonstrate that PINN’s local and global mass balance errors are significant compared to the finite volume approach. Tuning the PINN’s hyperparameters, such as the number of collocation points, training data, hidden layers, nodes, epochs, and learning rate, did not improve the solution accuracy or the mass balance errors compared to the finite volume solution. Mass balance errors could considerably challenge the utility of PINN in applications where ensuring compliance with physical and mathematical properties is crucial.

54 ENVIRONMENTAL SCIENCES↗

Galerkin formulations of isogeometric shell analysis: Alleviating locking with Greville quadratures and higher-order elements

Here we propose new quadrature schemes that asymptotically require only four in-plane points for Reissner–Mindlin shell elements and nine in-plane points for Kirchhoff–Love shell elements in B-spline and NURBS-based isogeometric shell analysis, independent of the polynomial degree p of the elements. The quadrature points are Greville abscissae associated with pth-order B-spline basis functions whose continuities depend on the specific Galerkin formulations, and the quadrature weights are calculated by solving a linear moment fitting problem in each parametric direction. The proposed shell element formulations are shown through numerical studies to be rank sufficient and to be free of spurious modes. The studies reveal comparable accuracy, in terms of both displacement and stress, compared with fully integrated spline-based shell elements, while at the same time reducing storage and computational cost associated with forming element stiffness and mass matrices and force vectors. The high accuracy with low computational cost makes the proposed quadratures along with higher-order spline bases, in particular polynomial orders, p = 5 and 6, good choices for alleviating membrane and shear locking in shells.

42 ENGINEERING↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Multirate partitioned Runge–Kutta methods for coupled Navier–Stokes equations

Earth system models are complex integrated models of atmosphere, ocean, sea ice, and land surface. Coupling the components can be a significant challenge due to the difference in physics, temporal, and spatial scales. Further, this study explores multirate partitioned Runge-Kutta methods for the fluid-fluid interaction problem and demonstrates its parallel performance by using the PETSc library. We consider compressible Navier-Stokes equations with gravity coupled through a rigid-lid interface. Our large-scale numerical experiments reveal that multirate partitioned Runge-Kutta coupling schemes (1) can conserve total mass; (2) have second-order accuracy in time; and (3) provide favorable strong- and weak-scaling performance on modern computing architectures. We also show that the speedup factors of multirate partitioned Runge-Kutta methods match theoretical expectations over their base (single-rate) method.

54 ENVIRONMENTAL SCIENCES↗

H i asymmetries in LVHIS, VIVA, and HALOGAS galaxies

ABSTRACT We present an analysis of morphological, kinematic, and spectral asymmetries in observations of atomic neutral hydrogen (H i) gas from the Local Volume H i Survey (LVHIS), the VLA Imaging of Virgo in Atomic Gas (VIVA) survey, and the Hydrogen Accretion in Local Galaxies Survey. With the aim of investigating the impact of the local environment density and stellar mass on the measured H i asymmetries in future large H i surveys, we provide recommendations for the most meaningful measures of asymmetry for use in future analysis. After controlling for stellar mass, we find signs of statistically significant trends of increasing asymmetries with local density. The most significant trend we measure is for the normalized flipped spectrum residual (Aspec), with mean LVHIS and VIVA values of 0.204 ± 0.011 and 0.615 ± 0.068 at average weighted 10th nearest-neighbour galaxy number densities of log (ρ10/Mpc−3) = −1.64 and 0.88, respectively. Looking ahead to the Widefield ASKAP L-band Legacy All-sky Blind survey on the Australian Square Kilometre Array Pathfinder, we estimate that the number of detections will be sufficient to provide coverage over 5 orders of magnitude in both local density and stellar mass increasing the dynamic range and accuracy with which we can probe the effect of these properties on the asymmetry in the distribution of atomic gas in galaxies.

Reynolds, T. N.↗

Exclusive π 0 p electroproduction off protons in the resonance region at photon virtualities 0.4 GeV 2 ≤ Q 2 ≤ 1 GeV 2

The limited electroproduction process e p → e ' p ' π 0 was measured in the range of photon virtualities Q 2 = 0.4 – 1.0 GeV 2 and the invariant mass range of the p π 0 system of W = 1.1 – 1.8 GeV. These kinematics are covered in exclusive π 0 electroproduction off the proton with nearly complete angular coverage in the p π 0 center-of-mass system and with high statistical accuracy. Nearly 36 000 cross-section points were measured, and the structure functions σ T + ε σ L , σ L T , and σ T T , were extracted via fitting the φ π 0 dependence of the cross section. A Legendre polynomial expansion analysis demonstrates the sensitivity of our data to high-lying N * and Δ * resonances with M > 1.6 GeV. As part of a broad effort to determine the electrocouplings of the N * and Δ * resonances using both single- and double-pion electroproduction, this dataset is key for the reliable extraction of the high-lying resonance electrocouplings from the combined isospin analysis of the N π and π + π - p channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on the Maximum Densities of Neutron Stars from Postmerger Gravitational Waves with Third-Generation Observations

Using data from 289 numerical relativity simulations of binary neutron star mergers, we identify, for the first time, a robust quasiuniversal relation connecting the postmerger peak gravitational-wave frequency and the value of the density at the center of the maximum mass nonrotating neutron star. This relation offers a new possibility for precision equation-of-state constraints with next-generation ground-based gravitational-wave interferometers. Mock Einstein Telescope observations of fiducial events indicate that Bayesian inferences can constrain the maximum density to ~15% (90% credibility level) for a single signal at the minimum sensitivity threshold for a detection. If the postmerger signal is included in a full-spectrum (inspiral-merger-postmerger) analysis of such a signal, the pressure-density function can be tightly constrained up to the maximum density, and the maximum neutron star mass can be measured with an accuracy better than 12% (90% credibility level).

79 ASTRONOMY AND ASTROPHYSICS↗

Probing Transit Timing Variation and Its Possible Origin with 12 New Transits of TrES-3b

We present 12 new transit light curves of the hot-Jupiter TrES-3b observed during 2012−2018 to probe the transit timing variation (TTV). By combining the midtransit times determined from these 12 transit data with those reestimated through uniform procedure from 71 transit data available in the literature, we derive new linear ephemeris and obtain the timing residuals that suggest the possibility of TTV in the TrES-3 system. However, the frequency analysis shows that the possible TTV is unlikely to be periodic, indicating the absence of an additional body in this system. To explore the other possible origins of TTV, the orbital decay and apsidal precession ephemeris models are fitted to the transit time data. We find the decay rate of TrES-3b to be P-dot {sub q}=−4.1±3.1 ms yr{sup −1}, and the corresponding estimated modified stellar tidal quality factor of Q{sub ∗}{sup ′}∼1.11×10{sup 5} is consistent with the theoretically predicted values for the stars hosting the hot-Jupiters. The shift in the transit arrival time of TrES-3b after 11 years is expected to be T {sub shift} ∼ 69.55 s, which is consistent with the rms of the timing residuals. Besides, we find that the apsidal precession ephemeris model is statistically less probable than the other considered ephemeris models. It is also discussed that despite the fact that the linear ephemeris model appears to be the most plausible model to represent the transit time data, the possibility of the orbital decay cannot be completely ruled out in the TrES-3 system. To confirm this, further high-precision and high-cadence follow-up observation of transits of TrES-3b would be important.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for a Precise Equation of State Measurement from Advanced LIGO and Cosmic Explorer

Gravitational-wave observations of neutron star mergers can probe the nuclear equation of state by measuring the imprint of the neutron star's tidal deformability on the signal. We investigate the ability of future gravitational-wave observations to produce a precise measurement of the equation of state from binary neutron star inspirals. Because measurability of the tidal effect depends on the equation of state, we explore several equations of state that span current observational constraints. We generate a population of binary neutron stars as seen by a simulated Advanced LIGO–Virgo network, as well as by a planned Cosmic Explorer observatory. We perform Bayesian inference to measure the parameters of each signal, and we combine measurements across each population to determine R 1.4 , the radius of a 1.4 M ⊙ neutron star. We find that, with 321 signals, the LIGO–Virgo network is able to measure R 1.4 to better than 2% precision for all equations of state we consider; however, we also find that achieving this precision could take decades of observation, depending on the equation of state and the merger rate. On the other hand, we find that with one year of observation, Cosmic Explorer will measure R 1.4 to better than 0.6% precision. In both cases, we find that systematic biases, such as from an incorrect mass prior, can significantly impact measurement accuracy, and efforts will be required to mitigate these effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Aemulus $\nu$: precise predictions for matter and biased tracer power spectra in the presence of neutrinos

Here we present the Aemulusν simulations: a suite of 150 (1.05 h -1 Gpc) 3 N-body simulations with a mass resolution of 3.51 × 10 10 Ω cb /0.3 h -1 M ⊙ in a wνCDM cosmological parameter space. The simulations have been explicitly designed to span a broad range in σ8 to facilitate investigations of tension between large scale structure and cosmic microwave background cosmological probes. Neutrinos are treated as a second particle species to ensure accuracy to 0.5 eV, the maximum neutrino mass that we have simulated. By employing Zel'dovich control variates, we increase the effective volume of our simulations by factors of 10-10 5 depending on the statistic in question. As a first application of these simulations, we build new hybrid effective field theory and matter power spectrum surrogate models, demonstrating that they achieve ≤ 1% accuracy for k ≤ 1 hMpc -1 and 0 ≤ z ≤ 3, and ≤ 2% accuracy for k ≤ 4 hMpc -1 for the matter power spectrum. We publicly release the trained surrogate models, and estimates of the surrogate model errors in the hope that they will be broadly applicable to a range of cosmological analyses for many years to come.

79 ASTRONOMY AND ASTROPHYSICS↗

MolDiscovery: learning mass spectrometry fragmentation of small molecules

Identification of small molecules is a critical task in various areas of life science. Recent advances in mass spectrometry have enabled the collection of tandem mass spectra of small molecules from hundreds of thousands of environments. To identify which molecules are present in a sample, one can search mass spectra collected from the sample against millions of molecular structures in small molecule databases. The existing approaches are based on chemistry domain knowledge, and they fail to explain many of the peaks in mass spectra of small molecules. Here, we present molDiscovery, a mass spectral database search method that improves both efficiency and accuracy of small molecule identification by learning a probabilistic model to match small molecules with their mass spectra. A search of over 8 million spectra from the Global Natural Product Social molecular networking infrastructure shows that molDiscovery correctly identify six times more unique small molecules than previous methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Pair of TESS Planets Spanning the Radius Valley around the Nearby Mid-M Dwarf LTT 3780

We present the confirmation of two new planets transiting the nearby mid-M dwarf LTT 3780 (TIC 36724087, TOI-732, V = 13.07, K {sub s} = 8.204, R {sub s} = 0.374 R {sub ⊙}, M {sub s} = 0.401 M {sub ⊙}, d = 22 pc). The two planet candidates are identified in a single Transiting Exoplanet Survey Satellite sector and validated with reconnaissance spectroscopy, ground-based photometric follow-up, and high-resolution imaging. With measured orbital periods of P {sub b} = 0.77, P {sub c} = 12.25 days and sizes r {sub p,b} = 1.33 ± 0.07, r {sub p,c} = 2.30 ± 0.16 R {sub ⊕}, the two planets span the radius valley in period–radius space around low-mass stars, thus making the system a laboratory to test competing theories of the emergence of the radius valley in that stellar mass regime. By combining 63 precise radial velocity measurements from the High Accuracy Radial velocity Planet Searcher (HARPS) and HARPS-N, we measure planet masses of m{sub p,b}=2.62{sub −0.46}{sup +0.48} and m{sub p,c}=8.6{sub −1.3}{sup +1.6} M {sub ⊕}, which indicates that LTT 3780b has a bulk composition consistent with being Earth-like, while LTT 3780c likely hosts an extended H/He envelope. We show that the recovered planetary masses are consistent with predictions from both photoevaporation and core-powered mass-loss models. The brightness and small size of LTT 3780, along with the measured planetary parameters, render LTT 3780b and c as accessible targets for atmospheric characterization of planets within the same planetary system and spanning the radius valley.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for strong coupling measurement at hadron colliders using soft-drop jet mass

We compute the soft-drop jet-mass distribution from pp collisions to NNLL accuracy while including nonperturbative corrections through a field-theory based formalism. Using these calculations, we assess the theoretical uncertainties on an αs precision measurement due to higher order perturbative effects, nonperturbative corrections, and PDF uncertainty. We identify which soft-drop parameters are well-suited for measuring αs, and find that higher-logarithmic resummation has a qualitatively important effect on the shape of the jet-mass distribution. We find that quark jets and gluon jets have similar sensitivity to αs, and emphasize that experimentally distinguishing quark and gluon jets is not required for an αs measurement. We conclude that measuring αs to the 10% level is feasible now, and with improvements in theory a 5% level measurement is possible. Getting down to the 1% level to be competitive with other state-of-the-art measurements will be challenging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗