Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pressure and Temperature Sensitive Paint Measurements on Rotors

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John↗

Broadband Lidar Technique for Precision CO2 Measurement

Presented are preliminary experimental results, sensitivity measurements and discuss our new CO2 lidar system under development. The system is employing an erbium-doped fiber amplifier (EDFA), superluminescent light emitting diode (SLED) as a source and our previously developed Fabry-Perot interferometer subsystem as a detector part. Global measurement of carbon dioxide column with the aim of discovering and quantifying unknown sources and sinks has been a high priority for the last decade. The goal of Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission is to significantly enhance the understanding of the role of CO2 in the global carbon cycle. The National Academy of Sciences recommended in its decadal survey that NASA put in orbit a CO2 lidar to satisfy this long standing need. Existing passive sensors suffer from two shortcomings. Their measurement precision can be compromised by the path length uncertainties arising from scattering within the atmosphere. Also passive sensors using sunlight cannot observe the column at night. Both of these difficulties can be ameliorated by lidar techniques. Lidar systems present their own set of problems however. Temperature changes in the atmosphere alter the cross section for individual CO2 absorption features while the different atmospheric pressures encountered passing through the atmosphere broaden the absorption lines. Currently proposed lidars require multiple lasers operating at multiple wavelengths simultaneously in order to untangle these effects. The current goal is to develop an ultra precise, inexpensive new lidar system for precise column measurements of CO2 changes in the lower atmosphere that uses a Fabry-Perot interferometer based system as the detector portion of the instrument and replaces the narrow band laser commonly used in lidars with the newly available high power SLED as the source. This approach reduces the number of individual lasers used in the system from three or more to one - considerably reducing the risk of failure. It also tremendously reduces the requirement for wavelength stability in the source putting this responsibility instead on the Fabry-Perot subsystem.

Heaps, William S.↗

Satellite To Satellite Doppler Tracking (SSDT) for mapping of the Earth's gravity field

Two SSDT schemes were evaluated: a standard, low-low, SSDT configuration, which both satellites are in basically the same low altitude nearly circular orbit and the pair is characterized by small angular separation; and a more general configuration in which the two satellites are in arbitrary orbits, so that different configurations can be comparatively analyed. The standard low-low SSDT configuration is capable of recovering 1 deg X 1 deg surface anomalies with a strength as low as 1 milligal, located on the projected satellite path, when observing from a height as large as 300 km. The Colombo scheme provides an important complement of SSDT observations, inasmuch as it is sensitive to radial velocity components, while keeping at the same performance level both measuring sensitivity and measurement resolution.

Colombo, G.↗

Variation of aircraft noise annoyance

Laboratory and field studies were conducted to determine the basis for increased sensitivity of people to noise during aircraft noise studies. This change in sensitivity could be attributed to either a physiological time-of-day effect (i.e., a circadian rhythm) or simply to the total number of aircraft noise events experienced during a laboratory test period. In order to investigate the time-of-day factor, noise sensitivity measures were obtained from subjects at home with cassette tape recorders/headsets over a 24 hour period. The effect of number of aircraft noise events on noise sensitivity was investigated within a laboratory. In these tests, measures of sensitivity to noise were obtained from subjects before and after their exposure to varying numbers of aircraft noise events. The 24 hour data showed no evidence that noise sensitivity is physiologically cyclical. Consequently, these data can not explain annoyance response variation to aircraft noise tests conducted during the daytime. However, the number of aircraft noise events did influence the subject's noise sensitivity. This effect completely accounts for the systematic increase in noise sensitivity during a laboratory test period.

Dempsey, T. K.↗

On the location of acid-hydrolysable carbon in lunar soil fines

Soil fines exposed on the lunar surface accumulate small metallic iron particles and solar wind-derived carbon. In previous work, it has been suggested that an intimate association exists between one particular carbon phase, hydrolysable carbon, and very fine iron droplets, where the carbon is in solid solution in the iron. The earlier hypothesis of a constant carbon in iron concentration across a broad range of droplet sizes is testable by combining hydrolysable carbon determinations with a variety of magnetic measurements sensitive to different droplet diameters. New measurements of ferromagnetic resonance response on density and magnetic separates from size fractions of soil 12023 are interpreted as evidence that hydrolysable carbon is preferentially associated with the larger, magnetically stable single-domain iron particles rather than with the smaller superparamagnetic droplets. For the former, there is a quite uniform ratio of iron to carbon both within a series of separates from a single soil, and among soils of widely varying FeO content.

Fallick, A. E.↗

Near-field antenna testing using the Hewlett Packard 8510 automated network analyzer

Near-field antenna measurements were made using a Hewlett-Packard 8510 automated network analyzer. This system features measurement sensitivity better than -90 dBm, at measurement speeds of one data point per millisecond in the fast data acquisition mode. The system was configured using external, even harmonic mixers and a fiber optic distributed local oscillator signal. Additionally, the time domain capability of the HP8510, made it possible to generate far-field diagnostic results immediately after data acquisition without the use of an external computer.

Kunath, Richard R.↗

Near-contact diffusion and compensation in extrinsic photoconductors

Carrier diffusion from heavily doped contact regions has been experimentally monitored with resistivity measurements of variable thickness Si:P extrinsic photoconductors (n(+) -n-n(+)). Modeling of free carrier diffusion at the interface of heavily doped contacts and highly resistive bulk at low temperatures predicts extended regions (5-30 microns) of excess carriers in high purity materials so that, in thin device structures, free carrier diffusion profiles from each contact will overlap and determine the resistivity of the device. In this work, a decrease in resistivity of four orders of magnitude was observed in a 5-micron thick structure compared to a 10-micron thick device. The resistivity of an ohmic structure in the thin limit is strongly dependent on the bulk and near-contact compensation, and resistivity measurements can be used as a sensitive measure of compensation at interfaces or in the tail of implanted layers.

Olsen, C. S.↗

Association Between Vascular Density and Loss of Protective RAS During Early NPDR by Fractal Dimension

Purpose: Our hypothesis predicts that blood vessels within the retina increase in density during early-stage nonproliferative diabetic retinopathy (NPDR), based on previous results of a small retrospective study. For the current prospective study, the remodeling of arteries and veins during progression of early NPDR is assessed by a repertoire of parameters that includes the fractal dimension (D(sub f) ). In complex structures such as branching vascular trees, D(sub f) is a sensitive measure of space-filing capacity. The renin-angiotensin system (RAS) is implicated in DR pathogenesis and the function of circulating angiogenic cells (CACs), a critical bone marrow-derived population instrumental in vascular repair. Methods: Arterial and venous branching patterns were extracted from images of 6 normal controls and 3 early NPDR subjects (2 moderate, 1 mild) acquired by Heidelberg Spectralis (Registered Trademark) OCT following fluorescein angiography (FA). The vascular branching patterns were analyzed by NASAs VESsel GENeration Analysis (VESGEN) software, in which skeletonized representations were generated automatically to yield D(sub f) by the box-counting method. For binary 2D images, D(sub f) varies between limiting Euclidean dimensions of 1 and 2. Peripheral blood of diabetics and controls was collected for CD34+ CAC isolation. The gene expression of RAS in CACs was assessed by qPCR for Mas receptor to Ang-(1-7). The vasoreparative function of the CACs was measured by migration ability toward CXCL12 (SDF-1). Results: By D(sub f), venous and arterial densities were 1.370 +/- 0.006 and 1.329 +/- 0.016 for early NPDR, compared to 1.318 +/- 0.012 and 1.320 +/- 0.036 for control. The space filling capacity in early NPDR measured by D(sub f), a sensitive parameter, therefore demonstrated a pronounced increase for veins, but not for arteries. Mas receptor mRNA in CACs was increased in diabetics without DR but reduced with onset of NPDR, indicating possible loss of compensation of protective RAS during early DR. Migratory dysfunction of CD34+ cells was further associated with DR. Conclusions: As assessed by the fractal dimension in our preliminary study, the space-filling capacity of veins, but not arteries, was greater in early NPDR than in control. Larger patient populations will be examined as we complete our ongoing longitudinal study. Results further suggest the protective RAS axis within diabetic CACs is lost early in DR and is associated with increased vascular remodeling as evidenced by VESGEN analysis.

vascular↗

Inferring Ozone Production in an Urban Atmosphere using Measurements of Peroxynitric Acid

Observations of peroxynitric acid (HO2NO2) obtained simultaneously with those of NO and NO2 provide a sensitive measure of the ozone photochemical production rate. We illustrate this technique for constraining the ozone production rate with observations obtained from the NCAR C-130 aircraft platform during the Megacity Initiative: Local and Global Research Observations (MILAGRO) intensive in Mexico during the spring of 2006. Sensitive and selective measurements of HO2NO2 were made in situ using chemical ionization mass spectrometry (CIMS). Observations were compared to modeled HO2NO2 concentrations obtained from the NASA Langley highly-constrained photochemical time-dependent box model. The median observed-to-calculated ratio of HO2NO2 is 1.18. At NOx levels greater than 15 ppbv, the photochemical box model underpredicts observations with an observed-to-calculated ratio of HO2NO2 of 1.57. As a result, we find that at high NOx, the ozone production rate calculated using measured HO2NO2 is faster than predicted using accepted photochemistry. Inclusion of an additional HOx source from the reaction of excited state NO2 with H2O or reduction in the rate constant of the reaction of OH with NO2 improves the agreement.

Spencer, K. M.↗

Acceleration Measurement Comparison Program Report

Results are described for a comparison of accelerometer calibrations being performed at NASA laboratories between May 1994 and March 1995. A compilation was made of transfer standard frequency measurements and 100 Hz pick-up sensitivity measurements.

accelerometers accelerometer calibration↗

Molecular contamination study by interaction of a molecular beam with a platinum surface

The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.

Nuss, H. E.↗

Centroid position measurements and subpixel sensitivity variations with the MAMA detector

Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.

Morgan, Jeffrey S.↗

Temperature-Sensitive Coating Sensor Based on Hematite

A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

Bencic, Timothy J.↗

Why the SL9 Plumes Were All About the Same Height

Several of the SL9 ejecta plumes were observed by the HST to reach approximately the same height, about 3000 km above the jovian cloud tops. The duration of the infrared events, which were produced by the plume falling back on the atmosphere, measures time aloft and hence provides a second, more sensitive measure of plume height; the light curves indicate that the largest impacts produced modestly higher plumes. Evidently these plumes were launched with about the same vertical velocity, roughly 10-13 kilometers per second. As the impactors themselves were not all the same, nor the impacts equally luminous, nor the plumes equally opaque, the similar plume heights has been seen as a puzzle needing explanation. A second, closely related matter that needs to addressed quantitatively is the popular contention that a big plume requires a big impact. This view is misleading at best, yet plume heights can be used to constrain impact parameters. Dimensional analysis indicates that plume height goes as z alpha v (sup 2) (sub ej) alpha E/pH (sup 2), where v (sub ej) is the ejection velocity, E the explosion energy, and p and H the ambient pressure and scale height at termination. Using a semi-analytic model for the deceleration, disintegration, and destruction of intruding bodies by an ever-vigilant atmosphere, we find that the ratio E/pH(sup 2) is roughly constant for fragments with diameters of order 100 m to 1000 m. Constancy of v(sub ej) is in part due to the greater role of radiative ablation on the flight of smaller objects. We conclude that similar plume heights is a direct consequence of smaller impactors exploding at higher altitudes, in such a way that the different explosions were geometrically similar.

Zahnle, K.↗