Search NASA⌕ Search

SEARCH · Search NASA

Results for “method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Applying deep learning methods to develop new models of molecular charge transfer, nonadiabatic dynamics, and nonlinear spectroscopy in the condensed phase

Photon- and field-induced charge transfer has central importance in the generation and storage of electricity, the novel properties of materials, photo-induced catalysis, and electro-optic activity (e.g., photovoltaic cells, fuel cells, and organic chromophores for use in optical fibers and light-emission diodes). These non-equilibrium electronic and chemical transformations are probed by ultrafast, nonlinear spectroscopies. Accurate simulations play a crucial role in our ability to understand, optimize, and control these transformations. This project applies modern deep learning and machine learning (ML) methods to dramatically improve models of electronic dynamics, electronic-nuclear dynamics, and spectroscopic measurements for improved simulations of chemistry in complex environments, far from equilibrium phenomena, and processes in extreme environments, such as materials exposed to strong or resonant fields. This project develops accurate neural net models that go beyond predictive capability to also provide new insight into the fundamental physics underlying electron and nuclear dynamics. To achieve its objectives, this project explores and develops customized versions of high-capacity deep learning algorithms/models. These techniques are developed with an emphasis on fundamental chemical insight, not just predictive accuracy, to assist the development of the next generation of quantum simulation methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Method Optimization with Categorical and Constrained Continuous Parameters

Traditional approaches to analytical method optimization (e.g., univariate and “guess-and-check”) can be time-consuming, costly, and often fail to identify true optima within the parameter space. Previous work defined and implemented a generalized technique for method optimization for continuous method parameters, but a knowledge gap remains for the incorporation of categorical variables into these advanced method optimization schemes. This work presents and validates a generalized optimization approach that incorporates both continuous and categorical variables while also utilizing a multivariate, multiobjective optimization scheme with Karush–Kuhn–Tucker conditions to bound the optimization space to solutions within the physical limitations of the parameter space. Method optimization from a case study using GC–MS for the analysis of 11 analytical standards with objectives to minimize peak width and maximize peak height resulted in a 3 orders of magnitude improvement in the average peak height and a 2 orders of magnitude improvement in the average peak width compared to the least optimal (but reasonable) instrumental parameters utilized in this study. This approach to optimization allows for a customizable method optimization in which users can include both continuous and categorical variables to achieve objectives specific to their analytical goals. This approach significantly reduces the labor and cost associated with traditional method development approaches and can be applied in a variety of scientific fields across a range of laboratory techniques (e.g., instrument method development, sample preparation, and extraction techniques).

Amorphous materials↗

Scalable Enrichment of 48 Ca at the Solid/liquid Interface by Chemical and Electrochemical Methods

This award targets to develop methods to enrich 48 Ca, which is a critical isotope for synthesizing superheavy elements and testing the standard model through neutrinoless double beta decay. The team first tested chemical exchange-based separation between solids and liquids, which is based on the free energy change due to the different vibrational frequencies caused by Ca isotopes in a material. However, the separation factor (alpha), which is defined as the ratio of 40 Ca/ 48 Ca ratios in the two phases, only reach ~1.01. The team then developed liquid centrifugation-based isotope separation, where a Ca salt aqueous solution is centrifuged at a speed of ~60 kRPM, and 48 Ca is enriched at the bottom of a centrifuge tube due to its larger mass. A high α of ~1.2-1.4 is achieved for 40 Ca/ 48 Ca at 40 °C. This method is further approved to be generic for any isotope that can be dissolved in a liquid solution or form liquid chemicals near room temperature. The experimental results also align well with modeling prediction. The team further develop a model to evaluate isotope separation in countercurrent liquid centrifugation. The team found that the countercurrent configuration can also enhance isotope separation in liquids, similar with gas centrifugation, which boost separation for isotopes which are difficult to be gasified near room temperature.

07 ISOTOPE AND RADIATION SOURCES↗

Advancing radioactive material research method: the development of a novel in situ particle-attached microfluidic electrochemical cell

This study aims to develop a microgram-scale microfluidic electrochemical cell (E-cell) for investigating the redox behavior of uranium oxide (UO 2 ). The traditional bulk electrochemical methods may require shielded facilities to investigate the hazardous materials, e.g., spent nuclear fuel, due to high radiation levels. Microfluidic E-cells offer advantages such as reduced radiation exposure, control over fluid flow rates, and high-throughput capabilities. Methods: The design of the E-cell considers electrode morphology, adhesion to a thin membrane, electrode configuration, and vacuum compatibility. Three techniques, including FIB-SEM lift-out, Au coating, and polyvinylidene fluoride (PVDF) binder, are explored for fabricating and attaching microgram quantities of UO 2 as working electrodes. The PVDF binder method proves to be the most effective, enabling the creation of a vacuum-compatible microfluidic E-cell. Results and discussion: The PVDF binder method demonstrates successful electrochemical responses and allows for real-time monitoring of UO 2 electrode behavior at the microscale. It offers chemical imaging capabilities using in situ SEM/EDS analysis. The technique provides consistent redox outcomes similar to bulk electrochemical analysis. Conclusion: The development of a microgram-scale microfluidic electrochemical cell using the PVDF binder technique enables the investigation of UO 2 redox behavior. It offers a low-risk approach with reduced radiation exposure and high-throughput capabilities. The technique provides real-time monitoring and chemical imaging capabilities, making it valuable for studying spent nuclear fuel systems and material characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ecosystems and Networks Integrated with Genes and Molecular Assemblies (ENIGMA). Final report

The goal of the Stahl lab is to use a combination of isotopic, genomic, and activity-based analyses in the field, of selected field isolates, and defined synthetic communities to identify sources and sinks of different nitrogen species in the field, focusing on the FRC at the ORNL. The most general research objective is to characterize variants in the pathway for denitrification among field isolates and synthetic microbial assemblies as a foundation for predicting the biotic and abiotic controls of nitrogen and carbon transformations in the field. Specifically, we have focused on characterizing environmental controls of nitrous oxide emissions, an important greenhouse gas and ozone depleting molecule. Studies have mapped the flux of nitrous oxide and controlling genetic elements within the FRC subsurface, indicating the importance of different enzyme variants in nitrous oxide production and consumption in controlling surface emissions. We have developed methods to quantify and catalog the isotopic signatures imparted on nitrous oxide by different nitrous oxide reductase variants in isolated organisms and model synthetic communities. We have developed methods to quantify and catalog the nitrous oxide affinity of field relevant isolates and their biomass yield when respiring nitrous oxide on different carbon substrates. We continue to expand the collection of field-relevant microbial isolates within ENIGMA by focused enrichment and isolation from field material. These objectives have been facilitated by the development of new technologies, including: 1) the development of a multiplexed automated optical density measurement system for quantifying growth kinetics of microorganisms dependent on gaseous substrates in monoculture or gas exchange in synthetic communities and 2) the development of a microcalorimetric analysis format to quantify the impact of environmental stress on microbial maintenance energy. Since field relevant processes are mediated by assemblies of organisms interacting with each other and their local environment, we have also collaborated with other ENIGMA investigators on the assembly and characterization of synthetic communities. These studies have evaluated the role of organisms lacking a complete pathway for denitrification in the control of field processes, measuring process rates of assemblies of organisms that individually lack the full denitrification pathway but mediate the complete denitrification when growing together. These efforts have so far resulted in the publication of 18 peer reviewed papers ranging from ecological and physiological drivers of pathway optimization to field-scale process characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS) Final Report

The NIH Research Resource for Biomedical AMS was originally funded at Lawrence Livermore National Laboratory in 1999 to develop and apply the technology of accelerator mass spectrometry (AMS) in broad- based biomedical research. The Resource’s niche is to fill needs for ultra high sensitivity quantitation when isotope-labeled agents are used. The Research Resource’s Technology Research and Development (TR&D) efforts will focus on the needs of the biomedical research community in the context of seven Driving Biomedical Projects (DBPs) that will drive the Center’s technical capabilities through three core TR&Ds. We will expand our present capabilities by developing a fully integrated HPLC AMS to increase our capabilities for metabolic measurements, we will develop methods to understand cellular processes and we will develop and validate methods for the application of AMS in human studies, which is a growing area of demand by collaborators and service users. In addition, we will continue to support new and ongoing collaborative and service projects that require the capabilities of the Resource. The Center will continue to train researchers in the use of the AMS capabilities being developed, and the results of all efforts will be widely disseminated to advance progress in biomedical research. Towards these goals, our specific aims are to:1.) Increase the value and information content of AMS measurements by combining molecular speciation with quantitation of defined macromolecular isolates. Specifically, develop and validate methods for macromolecule labeling, characterization and quantitation.2.) Develop and validate methods and strategies to enable AMS to become more broadly used in human studies. Specifically, demonstrate robust methods for conducting pharmacokinetic/pharmacodynamics studies in humans and model systems.3.) Increase the accessibility of AMS to the Biomedical research community and the throughput of AMS through direct coupling to separatory instruments.4.) Provide high throughput 14C BioAMS analysis for collaborative and service clients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2-D seismic wave propagation using the distributional finite-difference method: further developments and potential for global seismology

SUMMARY We present a time-domain distributional finite-difference scheme based on the Lebedev staggered grid for the numerical simulation of wave propagation in acoustic and elastic media. The central aspect of the proposed method is the representation of the stresses and displacements with different sets of B-splines functions organized according to the staggered grid. The distributional finite-difference approach allows domain-decomposition, heterogeneity of the medium, curvilinear mesh, anisotropy, non-conformal interfaces, discontinuous grid and fluid–solid interfaces. Numerical examples show that the proposed scheme is suitable to model wave propagation through the Earth, where sharp interfaces separate large, relatively homogeneous layers. A few domains or elements are sufficient to represent the Earth’s internal structure without relying on advanced meshing techniques. We compare seismograms obtained with the proposed scheme and the spectral element method, and we show that our approach offers superior accuracy, reduced memory usage, and comparable efficiency.

Geochemistry & Geophysics↗

Dual-map framework for noise characterization of quantum computers

In order to understand the capabilities and limitations of quantum computers, it is necessary to develop methods that efficiently characterize and benchmark error channels present on these devices. In this paper, we present a method that faithfully reconstructs a marginal (local) approximation of the effective noise (MATEN) channel, that acts as a single layer at the end of the circuit. We first introduce a dual-map framework that allows us to analytically derive expectation values of observables with respect to noisy circuits. These findings are supported by numerical simulations of the quantum approximate optimization algorithm (QAOA) that also justify the MATEN, even in the presence of nonlocal errors that occur during a circuit. Finally, we demonstrate the performance of the method on Rigetti's Aspen-11 quantum computer for QAOA circuits up to six qubits, successfully predicting the observed measurements on a majority of the qubits.

Sud, James↗

Bosonic field digitization for quantum computers

Quantum simulation of quantum field theory is a flagship application of quantum computers that promises to deliver capabilities beyond classical computing. The realization of quantum advantage will require methods that can accurately predict error scaling as a function of the resolution and parameters of the model and that can be implemented efficiently on quantum hardware. In this paper, we address the representation of lattice bosonic fields in a discretized field amplitude basis, develop methods to predict error scaling, and present efficient qubit implementation strategies. A low-energy subspace of the bosonic Hilbert space, defined by a boson occupation number cutoff, can be represented with exponentially good accuracy by a low-energy subspace of a finite-size Hilbert space. The finite representation construction and the associated errors are directly related to the accuracy of the Nyquist-Shannon sampling and the finite Fourier transforms of the boson number states in the field and the conjugate-field bases. We analyze the relation between the boson mass, the discretization parameters used for wave function sampling, and the finite representation size. Numerical simulations of small size Φ 4 problems demonstrate that the boson mass optimizing the sampling of the ground state wave function is a good approximation to the optimal boson mass yielding the minimum low-energy subspace size. However, we find that accurate sampling of general wave functions does not necessarily result in accurate representation. Finally, we develop methods for validating and adjusting the discretization parameters to achieve more accurate simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermophysical Property Measurements: Improved Density, Viscosity and Thermal Diffusivity Methods

The technical bases and methods developed at Argonne to measure thermophysical properties of molten salt mixtures are summarized and representative results provided to show the accuracy and precision achieved. Three key measurements addressed in this report are density, viscosity and thermal diffusivity. The densities of two eutectic FLiNaK mixtures were measured at temperatures to approximately 750 °C and the results are compared with literature values. The results are used to show how the effect of salt surface tension is taken into account in the density calculation and how the surface tension for other salt mixtures is being measured. Viscosity measurements of eutectic FLiNaK are shown to illustrate improvements to the measurement method being made to address and minimize the sources of error and uncertainties in the reported values. Thermal diffusivity measurements of FLiNaK are shown to illustrate the measurement method developed at Argonne and the achieved precision. The thermal diffusivity of the graphite used to make the cells that contain the salts during analyses was measured to assess the relative contribution to the response. The improved procedures developed in this work are being applied in property measurements of other salts of interest.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data from a multi-year targeted proteomics study of a longitudinal birth cohort of type 1 diabetes

The deployment of liquid chromatography-mass spectrometry-based plasma proteomics experiments in a large cohort is sparse, leading to a lack of data available for benchmarking, method development or validation. Comprised of 6,426 plasma analyses, The Environmental Determinants of Diabetes in the Young (TEDDY) proteomics validation study constitutes one of the largest targeted proteomics experiments in the literature to date. The proteomics data from this study were generated over the course of 2.5 years from over 900 study subjects, each providing up to 29 longitudinal samples. The data also includes 916 quality control samples. The targeted mass spectrometry assay was comprised of 694 peptides mapping to 167 proteins and the panel was measured in each subject and QC sample. The targeted proteomic dataset presented here can be used as a resource for new computational method development, such as for batch correction, as well as for benchmarking and comparing the performance of different methods/tools.

60 APPLIED LIFE SCIENCES↗

Splat Quenching as a High Throughput Rapid Solidification Testing Method for Developing Additive Manufacturing Alloys

Splat quenching as a high throughput rapid solidification screening tool is evaluated. Samples were made using known alloys (SS316, IN625, Ti-5553) to evaluate and establish the microstructures for a variety of alloy systems as well as the predicted cooling rates. The samples are inductively heated and levitated prior to being struck between two platens that produce a high contact pressure and a thin sample resulting in cooling rates on the order of 10 6 to 10 7 K/s. Process parameters were evaluated with analytical models in addition to numerical simulations to provide an effect of process variables such as substrate material, melt superheat, and platen velocity on the resulting solidification. The splat thickness was found to be controlled by platen velocity, melt superheat, as well as the feedstock volume. The sample thickness is the key controlling factor for varying the average cooling rate experienced by the splat quenched sample. The splat quenching techniques can reach regions of rapid solidification space that meet and exceed laser and electron beam techniques across the sample. In conclusion, the results of the study provide a useful foundation in understanding the splat quenching technique and its potential as a low effort tool to explore rapid solidification effects on alloys.

Alloy Design↗