3D Experimental Measurements of Evolution of Force Chains in Natural Silica Sand

The mechanisms of force transmission in granular materials is a classic physics problem that has been addressed since the 19th century, when Heinrich Rudolf Hertz investigated the interaction between two similar objects that were in contact under compression. However, the study of force transmission mechanisms in assemblies of more particles has proven to be a formidable problem due to the complex nature of granular materials. In recent years, synchrotron microcomputed tomography (SMT) and three-dimensional X-ray diffraction microscopy (3DXRD) have been employed to study the mechanics of granular materials experimentally. Combining SMT and 3DXRD offers unique three-dimensional (3D) experimental measurements of the internal structure, kinematics (such as rotation and translation), and lattice strains of individual sand particles. In this paper, in situ SMT and 3DXRD scans were acquired at multiple load steps for a specimen composed of 2,705 natural Ottawa sand particles that were subjected to one-dimensional (1D) confined compression. An algorithm was developed to combine SMT images and 3DXRD lattice strain measurements and used to characterize the constitutive behavior of sand particles. The results were used to identify the crystal structure and the evolution of the stresses and lattice strains of individual sand particles. Another algorithm was developed to characterize the force structures within the specimen. Force structures were identified, and their properties (such as length) and evolution through the experiment were examined. The contact number of particles is a particle-scale property that affects the mechanics of granular materials. The effect of the contact number of the sand particles on the onset and evolution of the force structures was also investigated and discussed.

3D x-ray diffraction microscopy↗

Discrepancy in the Critical State Void Ratio of Poorly Graded Sand due to Shear Strain Localization

The critical state (CS) concept is a theoretical framework that models the constitutive behavior of soils, including sand and other granular materials. It supports the notion of a unique postfailure state, where the soil ultimately experiences continuous shearing with no change in the plastic volumetric strain. However, the published literature has frequently noted the nonconvergence of sand specimens with different initial densities to a unique CS in the compression plane due to many factors such as specimen fabric, particle morphology, breakage, and grain size distribution. This paper examines the CS for poorly graded (uniform) glass beads and 3 different types of silica sands using 50 conventional triaxial compression (CTC) experiments, 12 oedometer tests, and in situ synchrotron microcomputed tomography (SMT) scans for 10 CTC experiments. The results of the 50 CTC experiments revealed a diffused CS zone in the compression plane, which was further examined using the in situ SMT scans. A thorough three-dimensional image analysis of the SMT scans accurately quantified the evolution of the local void ratio (elocal) versus axial compression within zones of intensive shearing toward the center of the specimen. The evolution of the void ratio was also measured using the entire volume of the specimen (eglobal). At the CS, the elocal/eglobal ratio was assessed to be ~1.25 when a single shear band developed within the scanned specimens and ~1.1-1.15 for specimens that failed via external bulging that was internally manifested by the development of multiple shear bands. This finding suggests that the CS zone in the compression plane can be attributed to the common wrong consideration of eglobal evolution in lieu of elocal within the developing shear bands. Furthermore, the lack of shear band development in uniaxial compression has made the results of the oedometer test reliable in quantifying the CS parameters in the compression plane.

58 GEOSCIENCES↗

Influence of Pore Water on the Fracture of Silica Sand at Particle Scale

The fracture of particles has a significant influence on the engineering behavior of granular materials. There are no reported conclusive answers in the literature to explain the influence of pore water on the fracture of sand, gravel, railroad ballast rock, aggregates, rockfill, and so on. Here, in this paper, two novel techniques were adopted to investigate the influence of pore water on the fracture of natural silica sand at the particle scale. The three-dimensional (3D) synchrotron microcomputed tomography (SMT) imaging technique was used to acquire and analyze multiple 3D images of specimens composed of wetted silica sand that were subjected to confined one-dimensional (1D) compression loading up to the fracture stage. A few representative particles were identified and digitally separated from the liquid water and gas phases. The 3D SMT images offer clear experimental evidence of the phase transition of water from liquid to gas within the opening cracks. In addition, a computational fluid dynamics numerical simulation framework for water flow into an opening crack was adopted and the results show that the fast opening of the crack induced cavitation, water phase transition, and water hammer effects. The results of the numerical simulations agree with the confined 1D compression experiments where the onset of the bubbles (gas phase) within the crack is mainly generated during the secondary cavitation stage, and the generated bubble near the crack mouth opening resulted from the primary cavitation, which was directly caused by the crack expansion. The results reported in this paper present a new cavitation phenomenon that occurs during particle fracture, which offers a physics-based explanation of why water-wetted sand fractures at smaller stresses than dry and can pave the way for more in-depth future studies on the fracture of water-wetted sand.

cavitation↗

Evaluation of Radiation Dose Effects on Rat Bones Using Synchrotron Radiation Computed Microtomography

In this work, we investigated the consequences of irradiation in the femora and ribs of rats submitted to radiation doses of 5 Gy. Three different sites in femur specimens (head, distal metaphysis and distal epiphysis) and one in ribs (ventral) were imaged using synchrotron radiation microcomputed tomography to assess trabecular bone microarchitecture. Histomorphometric quantification was calculated directly from the 3D microtomographic images using synchrotron radiation. The 3D microtomographic images were obtained at the SYRMEP (SYnchrotron Radiation for MEdical Physics) beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. A better understanding of the biological interactions that occur after exposure to photon radiation is needed in order to optimize therapeutic regimens and facilitate development and strategies that decrease radiation-induced side effects in humans. Results showed significant differences between irradiated and non-irradiated specimens, mostly in head and distal metaphysis bone sites.

60 APPLIED LIFE SCIENCES↗

Spatial organization and correlation properties quantify structural changes on mesoscale of parenchymatous plant tissue

The study of plant tissue parenchyma's intercellular air spaces contributes to the understanding of anatomy and physiology. This is challenging due to difficulty in making direct measurements of the pore space and the complex mosaic of parenchymatous tissue. The architectural complexity of pore space has shown that single geometrical measurements are not sufficient for characterization. The inhomogeneity of distribution depends not only on the percentage content of phase, but also on how the phase fills the space. The lacunarity morphometric, as multiscale measure, provides information about the distribution of gaps that correspond to degree of spatial organization in parenchyma. Additionally, modern theories have suggested strategies, where the focus has shifted from the study of averages and histograms to the study of patterns in data fluctuations. Detrended fluctuation analysis provides information on the correlation properties of the parenchyma at different spatial scales. The aim is to quantify (with the aid of the aforementioned metrics), the mesostructural changes—that occur from one cycle of freezing and thawing—in the void phase of pome fruit parenchymatous tissue, acquired with X-ray microcomputed tomography. Complex systems methods provide numerical indices and detailed insights regarding the freezing-induced modifications upon the arrangement of cells and voids. These structural changes have the potential to lead to physiological disorders. The work can further stimulate interest for the analysis of internal plant tissue structures coupled with other physico-chemical processes or phenomena.

60 APPLIED LIFE SCIENCES↗

Microstructural investigation of PBX 9501: Comparing wet slurry and resonant acoustic mixing techniques

The microstructure of a high explosive (HE) material directly influences the reactive behavior under a variety of insults. Furthermore, the preparation method of polymer-bonded explosives (PBX), as well as the constituent material particle size distribution and consolidation parameters, will dominate the microstructural features that are observed. Here, we compare batches of PBX 9501 prepared by the typical wet slurry process and those prepared by resonant acoustic mixing. The “prills” produced by the wet slurry process leads to an inherently different microstructure than the coated powder produced by resonant acoustic mixing. Additionally, we observed that the conditions required to consolidate (press) the material to the nominal PBX 9501 density varied depending on the preparation technique, which also dictates the observed binder distribution. Furthermore, X-ray microcomputed tomography and ultra-small-angle X-ray scattering analyses revealed distinct differences in the void structure and distribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Foliar water uptake does not contribute to embolism repair in beech ( Fagus sylvatica L.)

Abstract Background and Aims Foliar water uptake has recently been suggested as a possible mechanism for the restoration of hydraulically dysfunctional xylem vessels. In this paper we used a combination of ecophysiological measurements, X-ray microcomputed tomography and cryo-scanning electron microscopy during a drought treatment to fully evaluate this hypothesis. Key Results Based on an assessment of these methods in beech (Fagus sylvatica L.) seedlings we were able to (1) confirm an increase in the amount of hydraulically redistributed water absorbed by leaves when the soil water potential decreased, and (2) locate this redistributed water in hydraulically active vessels in the stem. However, (3) no embolism repair was observed irrespective of the organ under investigation (i.e. stem, petiole or leaf) or the intensity of drought. Conclusions Our data provide evidence for a hydraulic pathway from the leaf surface to the stem xylem following a water potential gradient, but this pathway exists only in functional vessels and does not play a role in embolism repair for beech.

Plant Sciences↗

Starch depletion in the xylem and phloem ray parenchyma of grapevine stems under drought

Abstract While nonstructural carbohydrate (NSC) storage can support long-lived woody plants during abiotic stress, the timing and extent of their use are less understood, as are the thresholds for cell mortality as NSCs and water supplies are consumed. Here, we combine physiological and imaging tools to study the response of Vitis riparia to a 6-week experimental drought. We focused on the spatial and temporal dynamics of starch consumption and cell viability in the xylem and phloem of the stem. Starch dynamics were further corroborated with enzymatic starch digestion and X-ray microcomputed tomography imaging. Starch depletion in the stems of droughted plants was detected after 2 weeks and continued over time. We observed distinct differences in starch content and cell viability in the xylem and phloem. By the end of the drought, nearly all the starch was consumed in the phloem ray parenchyma (98 % decrease), and there were almost no metabolically active cells in the phloem. In contrast, less starch was consumed in the xylem ray parenchyma (30 % decrease), and metabolically active cells remained in the ray and vessel-associated parenchyma in the xylem. Our data suggest that the higher proportion of living cells in the phloem and cambium, combined with smaller potential NSC storage area, rapidly depleted starch, which led to cell death. In contrast, the larger cross-sectional area of the xylem ray parenchyma with higher NSC storage and lower metabolically active cell populations depleted starch at a slower pace. Why NSC source-sink relationships between xylem and phloem do not allow for a more uniform depletion of starch in ray parenchyma over time is unclear. Our data help to pinpoint the proximate and ultimate causes of plant death during prolonged drought exposure and highlight the need to consider the influence of within-organ starch dynamics and cell mortality on abiotic stress response.

59 BASIC BIOLOGICAL SCIENCES↗

Geometrical-Based Generative Adversarial Network to Enhance Digital Rock Image Quality

X-ray microcomputed tomography (micro-CT) is a common tool for the study of porous media structures and properties. High-quality micro-CT data are required to accurately capture pore structures. Acquiring high-quality micro-CT data, however, is not always possible, owing to application limitations and experimental constraints. Therefore, we propose a geometrical-based generative adversarial network (GAN) to rapidly restore noisy micro-CT images to their clean counterparts. The training data and related ground-truth (GT) data are scanned for 7 min and 9.5 h, respectively. To evaluate the performance of the geometrical-based GAN, a 6003 voxel image that has never been used for training is reconstructed and compared with the corresponding GT image. Histogram matching and linear normalization are implemented to adjust the histogram of the reconstructed image to that of the GT image. A watershed-based segmentation method is then applied to delineate pore and solid phases. Lastly, we measure the Minkowski functionals and petrophysical properties, including absolute permeability, pore size distribution, drainage capillary pressure-saturation curve, and imbibition relative permeability, to estimate the physical accuracy of the denoised image. The results show that the proposed geometrical-based GAN can accurately restore noisy micro-CT data. By reducing the scanning time from 9.5 h to 7 min, the expenditure of collecting micro-CT can be decreased significantly. This is particularly important for applications where time-lapse images of a dynamic process are required, high-throughput imaging is necessary for real-time data analysis, or where the quantification of large sample volumes is required.

58 GEOSCIENCES↗

Geometric state function for two-fluid flow in porous media

Models that describe two-fluid flow in porous media suffer from a widely recognized problem that the constitutive relationships used to predict capillary pressure as a function of the fluid saturation are nonunique, thus requiring a hysteretic description. As an alternative to the traditional perspective, we consider a geometric description of the capillary pressure, which relates the average mean curvature, the fluid saturation, the interfacial area between fluids, and the Euler characteristic. The state equation is formulated using notions from algebraic topology and cast in terms of measures of the macroscale state. Synchrotron-based x-ray microcomputed tomography and high-resolution pore-scale simulation is applied to examine the uniqueness of the proposed relationship for six different porous media. We show that the geometric state function is able to characterize the microscopic fluid configurations that result from a wide range of simulated flow conditions in an averaged sense. The geometric state function can serve as a closure relationship within macroscale models to effectively remove hysteretic behavior attributed to the arrangement of fluids within a porous medium. As a result, this provides a critical missing component needed to enable a new generation of higher fidelity models to describe two-fluid flow in porous media.

42 ENGINEERING↗

Characterization of enamel caries lesions in rat molars using synchrotron X-ray microtomography

Dental caries is a ubiquitous infectious disease with a nearly 100% lifetime prevalence. Rodent caries models are widely used to investigate the etiology, progression and potential prevention or treatment of the disease. To explore the suitability of these models for deeper investigations of intact surface zones during enamel caries, the structures of early-stage carious lesions in rats were characterized and compared with previous reports on white spot enamel lesions in humans. Synchrotron X-ray microcomputed tomography non-destructively mapped demineralization in carious rat molar specimens across a range of caries severity, identifying 52 lesions across the 30 teeth imaged. Of these lesions, 13 were shown to have intact surface zones. Depth profiles of fractional mineral density were qualitatively similar to lesions in human teeth. However, the thickness of the surface zone in the rat model ranges from 10 to 58 µm, and is therefore significantly thinner than in human enamel. These results indicate that a fraction of lesions in rat caries possess an intact surface zone and are qualitatively similar to human lesions at the micrometer scale. This suggests that rat caries models may be a suitable analog through which to investigate the structure of surface zone enamel and its role during dental caries.

60 APPLIED LIFE SCIENCES↗

Effect of calcite filler on carbonation behavior in a synthesized C‐S‐H binder

Widespread implementation of portland limestone cements (PLC) in industry has raised new questions about their carbonation resistance due to higher initial limestone content than ordinary portland cement. While carbonation of portland cement and each of its hydrate phases has been studied at a fundamental level, the integral role of how limestone fillers interact chemically or physically during carbonation necessitates further study. In this study, a C-S-H binder comprised of a highly reactive zeolite pozzolan and lime was used to evaluate the effect of varying calcite additions on carbonation behavior at a microstructural level. Fundamental insight into hydration kinetics and carbonation mechanisms of hydraulic binders was obtained via analysis of the C-S-H and calcite microstructure. X-ray microcomputed tomography (X-ray CT) was used to quantify microstructural changes, and the results showed a decrease in shrinkage for increased calcite dosages, with a ∼50% reduction observed for a 45% wt. calcite replacement level. Crystallographic and thermal analyses measured compositional changes in the binder and confirmed that shrinkage was related to the decalcification of C-S-H. Furthermore, the addition of calcite to the C-S-H binder effectively reduced the liquid-to-solid ratio, porosity, and amount of C-S-H present in these binders. Ultimately, these results help elucidate how the carbonation risks of PLC can be mitigated by proportioning the mixture water only to the reactive component of the binder.

C-S-H↗

The bias of a two‐dimensional view: comparing two‐dimensional and three‐dimensional mesophyll surface area estimates using noninvasive imaging

Summary The mesophyll surface area exposed to intercellular air space per leaf area ( S m ) is closely associated with CO 2 diffusion and photosynthetic rates. S m is typically estimated from two‐dimensional (2D) leaf sections and corrected for the three‐dimensional (3D) geometry of mesophyll cells, leading to potential differences between the estimated and actual cell surface area. Here, we examined how 2D methods used for estimating S m compare with 3D values obtained from high‐resolution X‐ray microcomputed tomography (microCT) for 23 plant species, with broad phylogenetic and anatomical coverage. Relative to 3D, uncorrected 2D S m estimates were, on average, 15–30% lower. Two of the four 2D S m methods typically fell within 10% of 3D values. For most species, only a few 2D slices were needed to accurately estimate S m within 10% of the whole leaf sample median. However, leaves with reticulate vein networks required more sections because of a more heterogeneous vein coverage across slices. These results provide the first comparison of the accuracy of 2D methods in estimating the complex 3D geometry of internal leaf surfaces. Because microCT is not readily available, we provide guidance for using standard light microscopy techniques, as well as recommending standardization of reporting S m values.

Théroux‐Rancourt, Guillaume↗

Microstructural Analysis of the Effects of Thermal Runaway on Li-Ion and Na-Ion Battery Electrodes

Thermal runaway is a phenomenon that occurs due to self-sustaining reactions within batteries at elevated temperatures resulting in catastrophic failure. Here, the thermal runaway process is studied for a Li-ion and Na-ion pouch cells of similar energy density (10.5 Wh, 12 Wh, respectively) using accelerating rate calorimetry (ARC). Both cells were constructed with a z-fold configuration, with a standard shutdown separator in the Li-ion and a low-cost polypropylene (PP) separator in the Na-ion. Even with the shutdown separator, it is shown that the self-heating rate and rate of thermal runaway in Na-ion cells is significantly slower than that observed in Li-ion systems. The thermal runaway event initiates at a higher temperature in Na-ion cells. The effect of thermal runaway on the architecture of the cells is examined using X-ray microcomputed tomography, and scanning electron microscopy (SEM) is used to examine the failed electrodes of both cells. In conclusion, from examination of the respective electrodes, likely due to the carbonate solvent containing electrolyte, it is suggested that thermal runaway in Na-ion batteries (NIBs) occurs via a similar mechanism to that reported for Li-ion cells.

25 ENERGY STORAGE↗

Comparison of Single-Phase Convection in Additive Manufactured Versus Traditional Metal Foams

Abstract Metal foams have been often used for thermal management due to their favorable characteristics including high specific surface area (SSA), high thermal conductivity, and low relative density. However, they are accompanied by shortcomings including the significant contact resistances due to attachment method, as well as the need for characterization of foam parameters such as pore diameter and SSA. Additive manufactured (AM) metal foams would eliminate the substrate/foam thermal resistance, decrease the need for pre-usage characterization, and allow for tailoring structures, while also taking advantage of the characteristics of traditionally manufactured foams. A commercial, aluminum foam (nominally 5 pores per inch (PPI), 86.5% porosity) was analyzed using X-ray microcomputed tomography, and a custom-designed metal foam based on the cell diameter and porosity of the commercial sample was subsequently manufactured. Reduced domain computational fluid dynamics/heat transfer (CFD-HT) models were compared against experimental data. Postvalidation, the flow behavior, effect of varying attachment thermal conductivities, and thermal performance were numerically investigated, demonstrating the usefulness of validated pore-scale models, as well as the potential for improved performance using AM metal foams over traditionally manufactured foams.

Engineering↗

TLD assessment of mouse dosimetry during microCT imaging

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high resolution anatomic images of small animals. Because microCT utilizes ionizing radiation for image formation, radiation exposure during imaging is a concern. The objective of this study was to quantify the radiation dose delivered during a standard microCT scan. Radiation dose was measured using thermoluminescent dosimeters (TLDs), which were irradiated employing an 80 kVp x-ray source, with 0.5 mm Al filtration and a total of 54 mA s for a full 360 deg rotation of the unit. The TLD data were validated using a 3.2 cm{sup 3} CT ion chamber probe. TLD results showed a single microCT scan air kerma of 78.0{+-}5.0 mGy when using a poly(methylmethacrylate) (PMMA) anesthesia support module and an air kerma of 92.0{+-}6.0 mGy without the use of the anesthesia module. The validation CT ion chamber study provided a measured radiation air kerma of 81.0{+-}4.0 mGy and 97.0{+-}5.0 mGy with and without the PMMA anesthesia module, respectively. Internal TLD analysis demonstrated an average mouse organ radiation absorbed dose of 76.0{+-}5.0 mGy. The author's results have defined x-ray exposure for a routine microCT study which must be taken into consideration when performing serial molecular imaging studies involving the microCT imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

In vivo small animal imaging: Current status and future prospects

The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.

60 APPLIED LIFE SCIENCES↗