Advances in Electroplating Gradients and Thick Metallic Coatings on Microspherical Targets for Inertial Confinement Fusion
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Microlaser designs based on the coupling of whispering gallery modes (WGMs) with the upconversion processes which take place within lanthanide-doped nanoparticles (UCNPs) have been demonstrated and shown to have many valuable qualities, such as high Q factors and low lasing thresholds. One obstacle that these microlaser designs still face is the challenges caused by photothermal heating of the gain medium, which could be solved through the design of a radiation balanced microlaser. In this work, WGM microresonators composed of 5 µm diameter polystyrene spheres are fabricated with a layer of Yb3+-doped NaYF4 UCNPs in order to test if the anti-Stokes cooling properties of the UCNPs can cool the microresonator and its environment under laser irradiation. We find via calibrated mean fluorescence spectroscopy that the UCNPs can cool their local environment by as much as 23 °C and significantly reduce the heating of the aqueous environment surrounding the microresonator, showing promise for inclusion in a design for a radiation balanced microlaser.
The purpose of this project was to expand existing internal gelation sol-gel capabilities at PNNL to explore producing uranium dioxide spheres for potential use as fuel kernels in next generation Tri-isotropic (TRISO) particle fuel. This project expands on previous sol-gel efforts at PNNL by (1) increasing the size regime of sphere production from the micro-fluidic range to the milli-fluidic range, and (2) producing uranium spheres. The approach involved first scaling up the channel size of the fluidic system to the millimeter range, with radiation safety considerations in mind; testing and demonstration on non-radioactive surrogate material, cerium oxide; then transitioning to uranium production and finally optimizing system parameters. Commercially available fluidic chips in the desired size range were could not be found, therefore the project designed and fabricated a T-junction with 1mm channels for droplet production. Because the production process is temperature sensitive, prior efforts have involved performing droplet production in a lab freezer. To reduce radiological waste and footprint, two alternative chilling methods were explored using aluminum thermal beads as a chill bath and a custom aluminum block fit to reagent reservoir sizes. Both were successful in the cerium tests, however the aluminum block design outperformed the thermal bead bath and was further adapted for the radiological test and production run in the Radiochemical Processing Laboratory (RPL). Gelation trials were performed to determine an acceptable range of feed solution parameters for the uranium dioxide gels, characterized by R-values, which is determined by the ratio of uranium nitrate to Hexamethylenetetramine (HMTA)/urea in the feed solution. R-values ranging from 1.6-2 were examined in the gelation trials, with only the 1.8 condition being tested in production. The project was successful in demonstrating a proof of concept design for producing uranium dioxide spheres, however further optimization is needed to dial in production parameters and improve sphere quality and homogeneity.
Explore the source record for details and available documents.
Presented by LRST at the AIChE 2020 Annual Meeting, 11/17
Explore the source record for details and available documents.
The present disclosure relates to an apparatus for electroplating an element. The apparatus may comprise a cathode cage assembly. The cathode cage assembly may include a cage member and at least one electrically conductive wire extending along at least a portion of the cage member. The wire may be arranged to form at least one volume within the cage member for retaining an element within the cage member. The cage member and the wire permit a degree of movement of the element during an electroplating process while retaining the element within the volume.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In an experiment, the power that sustains a plasma was extinguished, so that microspheres, which had been levitated, fell downward toward a lower electrode. At the beginning of their fall, the microspheres were self-organized with a crystalline structure. This structure was found to be preserved as the microspheres accelerated all the way to the lower electrode. Although microspheres had, in this afterglow plasma, large positive charges of 12,500 e, their interparticle repulsion was unable to significantly alter the crystalline arrangement of the microspheres, as they fell. After their impact on the lower electrode, the microspheres bounced upward, and only then was the crystalline structure lost.
A new strategy using glass as a solid support for functionalization with chemical probes has been recently developed with successful results. The next step in glass functionalization is to pair chemical probes with fluorescent glass microspheres. This approach gives us a way to directly quantify probe-bound protein using Fluorescence-Activated Cell Sorting (FACS). FACS has already shown to be amendable to glass microspheres, demonstrating changes in probe-bound protein concentration. Suitable probing conditions for gram-positive and negative microbes, complex microbial communities from myriad ecosystems, and eukaryotic cells/tissues have traditionally suffered from set-backs, such as limited protein per sample and conditions atypical for probing. To remedy this, we propose to: (1) Demonstrate probe functionalization specific to glass microspheres by paired fluorophore and use those activity probes successfully with proteomics. Probes that are currently available (CYP5, GSH/GST, Glycoside Hydrolase) can be easily prepared onto glass surfaces. Probe-bound microspheres can be tested in ratios, first with known amounts of purified protein and then complex microbiome lysates. (2) Our validated microspheres are then used to determine quantitative amounts of protein through FACS sorting. Complimenting these results by proteomics, prepared microspheres are then optimized and condensed into a user-friendly kit. Once successfully commercialized, this multiplexed assay can be used with little to no technical expertise, making this available to various industries users.
Introduction: TheraSphere ® microspheres containing yttrium 90 Y are among many radioembolization agents used clinically to reduce liver tumor burden, and their effects on cancer volume reduction are well-established. At the same time, concerns about off target tissue injury often limit their use. Deeper investigation into tissue distribution and long-term impact of these microspheres could inform us about additional ways to use them in practice. Methods: Healthy rat liver and rabbit liver tumor samples from animals treated with TheraSpheres were sectioned and their elemental maps were generated by X-ray fluorescence microscopy (XFM) at the Advanced Photon Source (APS) synchrotron at Argonne National Laboratory (ANL). Results: Elemental imaging allowed us to identify the presence and distribution of TheraSpheres in animal tissues without the need for additional sample manipulation or staining. Ionizing radiation produced by 90 Y radioactive contaminants present in these microspheres makes processing TheraSphere treated samples complex. Accumulation of microspheres in macrophages was observed. Conclusions: This is the first study that used XFM to evaluate the location of microspheres and radionuclides in animal liver and tumor samples introduced through radioembolization. XFM has shown promise in expanding our understanding of radioembolization and could be used for investigation of human patient samples in the future.
The effective management of plastic waste streams to prevent plastic land and water pollution is a growing problem that is also one of the most important challenges in polymer science today. Polymer materials that are stable over their lifetime and can also be cheaply recycled or repurposed as desired could more easily be diverted from waste streams. However, this is difficult for most commodity plastics. It is especially difficult to conceive this with intractable, cross-linked polymers such as rubbers. In this work, we explore the utility of microencapsulated Grubbs’ catalysts for the in-situ depolymerization and reprocessing of polybutadiene (PB) rubber. Second-generation Hoveyda-Grubbs catalyst (HG2) contained within glassy thermoplastic microspheres can be dispersed in PB rubber below the microsphere’s glass transition temperature (T g ) without adverse depolymerization, evidenced by rubber with and without these microspheres obtaining similar shear storage moduli of ≈16 and ≈28 kPa, respectively. The thermoplastic’s T g can be used to tune the depolymerization temperature, via release of HG2 into the rubber matrix. For example, using poly(lactic acid) (PLA) vs polysulfone results in an 85 and 162 °C depolymerization temperature, respectively. Liquefaction of rubber to a mixture of small molecules and oligomers is demonstrated using a 0.01 mol % catalyst loading using PLA as the encapsulant. Furthermore, at that same catalyst loading, depolymerization occurs to a greater extent in comparison to two ex-situ approaches, including a conventional solvent-assisted method, where it occurs at roughly twice the extent at each given catalyst loading. In addition, depolymerization of the microsphere-loaded rubbers was demonstrated for samples stored under nitrogen for 23 days. Lastly, we show that the depolymerized products can be reprocessed back into solid rubber with a shear storage modulus of ≈32 kPa. Thus, we envision that this approach could be used to recycle and reuse cross-linked rubbers at the end of their product lifetime.
Dye-doped whispering gallery mode resonator (WGMR) microspheres yield highly structured emission spectra that are extremely sensitive to their environment and are of intense interest for use in a variety of sensing applications. Efforts to leverage the unique sensitivities of WGMRs have relied on stringent experimental requirements to correlate specific spectral shifts/changes to an analyte/stimulus such as 1) precise positional knowledge, 2) reference spectra for each microsphere, and 3) high mechanical stability. Consequently, these can hinder adequate mixing or incorporation of analytes and creates challenges for remote sensing. The MATLAB codes provided here are to be used in conjunction with a continuous flow technique for measuring WGM spectra of dye-doped microspheres suspended in solution. One MATLAB script, smooths the data, automatically baseline corrects it to isolate the whispering gallery modes (WGM) from the unwanted bulk emission, and assesses the similarity of each spectrum to aid in selecting a set of unique WGM spectra for further analysis. The next script is designed to analyze WGM spectra to determine the size of the resonator and the refractive index (RI) of its local environment without a priori knowledge of the individual microsphere. The final script allows the user to cluster spheres based on the product of their RI and radius and the contrast ratio of the RI of the sphere material and that of its environment by using a shared nearest neighbor spectral clustering algorithm.
Sandia National Laboratories is developing a way to visualize molecular changes that indicate penetration of a tamper-indicating enclosure (TIE). Such "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) allows inspectors to use simple visual observation to readily recognize that penetration into a material used as a TIE has been attempted, without providing adversaries the ability to repair damage. Such a material can significantly enhance the current capability for TIEs, used to support treaty verification regimes. Current approaches rely on time-consuming and subjective visual assessment by an inspector, external equipment, such as eddy current or camera devices, or active approaches that may be limited due to application environment. The complexity of securing whole volumes includes: (1) enclosures that are non-standard in size/shape; (2) enclosures that may be inspectorate- or facility-owned; (3) tamper attempts that are detectable but difficult or timely for an inspector to locate; (4) the requirement for solutions that are robust regarding reliability and environment (including facility handling); and (5) the need for solutions that prevent adversaries from repairing penetrations. The approach is based on a transition metal ion solution within a microsphere changing color irreversibly when the microsphere is ruptured. Investigators examine 3D printing of the microspheres as well as the spray coating formulation. The anticipated benefits of this work are passive, flexible, scalable, cost-effective TIEs with obvious and robust responses to tamper attempts. This results in more efficient and effective monitoring, as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time-consuming visual examination. Applications can include custom TIEs (cabinets or equipment enclosures), spray-coating onto facility-owned items, spray-coating of walls or structures, spray-coatings of circuit boards, and 3D-printed seal bodies. The paper describes research to-date on the sensor compounds and microspheres.
Quickly and easily producing uniform populations of microsphere-based 3D cell cultures using droplet-based templating methods has the potential to enable widespread use of such platforms in drug discovery or cancer research. Here, we advance the design of centrifuge-based droplet generation devices, describe the use of this platform for droplet generation with controlled cell occupancy, and demonstrate weeklong culture duration. Using simple-to-construct devices and easily implemented protocols, the initial concentration of encapsulated cells is adjustable up to hundreds of cells per microsphere. This work demonstrates the first instance of using centrifugal droplet-generating devices to produce large numbers of cell-encapsulating microspheres. Applications of this versatile methodology include the rapid formation of templated 3D cell culture populations suitable for suspension culture or large batch bioreactor studies that require uniform populations.
HRL Laboratories and General Motors (GM), pursued this effort to increase the efficiency of internal combustion engines (ICEs) by developing and implementing temperature-following thermal barrier coatings (TBCs) to decrease heat loss from the combustion chamber. HRL developed microsphere TBCs based on hollow high-temperature alloy spheres with average diameter of 50 μm and wall thickness ~1 μm (microspheres) that achieve unprecedented low thermal conductivity and heat capacity (10X lower than the state of the art) while offering exceptional environmental and mechanical resistance.> In current ICEs, approximately 29% of the fuel’s energy is lost to the cooling system and about 22% goes into moving the car. By limiting heat losses from the combustion chamber with insulating coatings, fuel energy can be redirected into additional piston work and into the exhaust stream. The additional energy that goes into the exhaust stream can be turned into useful work through the use of an exhaust energy recovery device, such as turbocompounding and/or through driving a turbocharger to increase the power density of the engine allowing downsizing. Insulating coatings for piston crowns have been pursued in the past, but previous materials—typically ceramics—exhibited low thermal conductivity but retained high heat capacity. Such materials reduce heat losses but stabilize at a high surface temperature. The high surface temperature heats the incoming gases, which lowers volumetric efficiency and increases propensity for knock, resulting in degraded engine performance. This program developed an innovative new material that combines low thermal conductivity with low heat capacity. These unique properties allow it to follow rapid changes in gas temperature during each combustion cycle. A metallic microsphere TBC has been demonstrated that exhibits increased surface temperature during the combustion period, resulting in reduced heat transfer losses, while still returning to a low surface temperature during the gas exchange period. A 10X lower thermal conductivity and heat capacity than state-of-the-art thermal barrier coatings has been demonstrated. These unprecedented thermal properties are achieved through the coating architecture, which consists of closed pores on the microscale and exhibits a total porosity of 90% to 95%. By selecting a high-temperature nickel alloy as the coating material, the ductility and strength of metals can be harnessed to achieve much better durability and damage tolerance than brittle ceramic coatings can achieve.
In FY21, Argonne National Laboratory (ANL) with researchers at Texas A&M University (TAMU) designed and engineered a prototypical device for accounting types of irradiated pebbles (for example with different 235U enrichments or pure graphite) in Pebble-Fueled Reactors (PFRs). Through engagements with reactor designers, a need arose to assist in identifying and categorizing types of pebbles as a complementary nuclear material control method that would synergize with designers’ use of fuel burnup measurements for material accountancy needs. As part of an overall nuclear material control approach, a concept of pebble batch accounting was investigated using extrinsic non-radiological features to identify intrinsic characteristics. This concept of batch accounting led to the ability of identifying types of pebbles based on characteristics such as initial 235U enrichment of pebble batches or dates of introduction into the reactor core. Identification was achieved by embedding the 5-mm thick graphite periphery of pebbles with 2-mm diameter inert Yttria-Stabilized Zirconia (YSZ) microspheres to achieve an averaged volumetric density (i.e., common spacing between microspheres) unique to that type of pebble. With an ultrasound imaging system in proximity with each pebble, the YSZ microspheres in the pebble proved visible and their spacing became the unique feature upon which pebble type categorization could occur. At the culmination of FY21, ANL intended on delivering and installing the prototype at TAMU for initial testing but, due to the on-going pandemic, this was postponed until FY22.