Search NASA⌕ Search

SEARCH · Search NASA

Results for “microtomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research

Purpose: Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. Methods: A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. Results: The authors’ experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors’ technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. Conclusions: This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure.

60 APPLIED LIFE SCIENCES↗

Microtomography of partially molten rocks : three-dimensional melt distribution in mantle peridotite.

The permeability of the upper mantle controls melt segregation beneath spreading centers. Reconciling contradictory geochemical and geophysical observations at ocean ridges requires a better understanding of transport properties in partially molten rocks. Using x-ray synchrotron microtomography, we obtained three-dimensional data on melt distribution for mantle peridotite with various melt fractions. At melt fractions as low as 0.02, triple junctions along grain edges dominated the melt network; there was no evidence of an abrupt change in the fundamental character of melt extraction as melt fraction increased to 0.2. The porosity of the partially molten region beneath ocean ridges is therefore controlled by a balance between viscous compaction and melting rate, not by a change in melt topology.

58 GEOSCIENCES↗

Upgraded X-ray topography and microtomography beamline at the Kurchatov synchrotron radiation source

An upgraded X-ray Topography and Microtomography (XRT-MT) station is described, the parameters of the optical schemes and detectors are given, and the experimental possibilities of the station are analyzed. Examples of tomographic reconstructions are reported which demonstrate spatial resolutions of 2.5 and 10 {mu}m at fields of view of 2.5 and 10 mm, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of a Deformed Inhomogeneous Material on the Data of Acoustic Emission and X-Ray Computer Microtomography

Accumulation of defects at various stages of the deformation of a structurally inhomogeneous material (granite) has been studied using two nondestructive methods: acoustic emission (AE) and X-ray computer microtomorgaphy (CT). The quasi-static testing of cylindrical samples of a Westerly granite was carried out under uniaxial compression. The control of the defect formation was realized using the real-time monitoring of acoustic emission. For each sample under study, several steps of the loading and tomographic imaging have been performed. We have found that an exponential or power-law function of the energy distribution of the AE signals makes it possible to select a sample region, in which the system of defects has transited into a self-organized criticality state and large cracks have been formed. This result coincides with the data of the X-ray tomography Computer Microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lithium-Sulfur Batteries with a Block Copolymer Electrolyte Analyzed by X-ray Microtomography

Most of the work on Lithium-sulfur (LiS) batteries use liquid electrolytes that have limited stability when coupled with Li metal anodes. We have studied LiS batteries with a solid block copolymer electrolyte which exhibits improved stability against Li anodes. Additionally, the electrolyte comprises a polystyrene-b-poly(ethylene oxide) (SEO) copolymer doped with a Li salt. Hollow carbon nanospheres impregnated with sulfur were used to build a composite cathode. Two types of sulfur-impregnated functionalized carbon nanospheres were used: One with carboxylic acid groups and the other with short lithium poly(4-styrenesulfonyl(trifluoromethylsulfonyl)imide) (PSTFSI-Li) chains. Cells with Li S dissolved in the SEO based electrolyte served as the baseline. After cycling, the reason for capacity fade was determined by imaging the batteries using synchrotron hard X-ray microtomography. It is generally assumed that LiS cells fail due to dissolution of polysulfide into the liquid electrolyte, i.e., the main problems related to the cathode. In our all-solid cells, failure was primarily due to delamination of the Li foil from the polymer electrolyte layer. Delamination is also observed at the sulfur cathode. It is likely that the large changes in volume of the active materials during cycling induce delamination in all-solid LiS cells. 2 8

25 ENERGY STORAGE↗

Pore-Scale Oil Connectivity and Displacement by Controlled-Ionic-Composition Waterflooding Using Synchrotron X-Ray Microtomography

Controlled-ionic-composition waterflooding is an economic and effective method to improve oil recovery in carbonate oil reservoirs. Recent studies show controlling the salinity and ionic composition of injection water can alter the wettability of carbonate mineral surfaces. The pore-scale oil connectivity and displacement by controlled-ionic-composition waterflooding in heterogeneous carbonate reservoirs, especially at the early stage, is still unclear. The goal of this study is to examine the role of ion concentrations and types in the oil displacement efficiency and investigate the impact of the waterflooding on the pore-scale oil displacement using the national synchrotron facility. A carbonate rock sample was flooded with synthetic high-salinity water and other water solutions with different sulfate concentrations. The waterflooding processes were visualized with synchrotron X-ray microtomography to follow the evolution of pore-scale oil/brine interactions at typical field flow rates. Experimental results show that the water with lower sulfate concentration and higher salinity did not change the wettability of the pore surfaces. Higher sulfate ion concentrations in the water, in contrast, altered the wettability of carbonate pore surfaces from oil-wet to neutral-wet within the first few minutes of waterflooding. Finally, novel insight was gained on the ability of water with high-sulfate concentration to displace oil in the small pores and through abundant oil channels, which could consequently lead to higher oil recovery from the carbonate rock.

04 OIL SHALES AND TAR SANDS↗

Using Low-Field Nuclear Magnetic Resonance and X-Ray Computed Microtomography Imaging to Explore Potential of Microbially-Induced Calcium Carbonate Precipitation Treatment to Seal Shale Fractures

Microbially-induced calcium carbonate precipitation (MICP) is a biological process in which microbially produced urease enzymes convert urea and calcium into solid calcium carbonate (CaCO 3 ) deposits. Studies have shown that MICP can be used to seal fractures in shale, raising the possibility of applying this technology to restimulate fracking wells by plugging underperforming fractures. For this and other applications to become a reality, non-invasive tools are needed to determine how effectively MICP seals shale fractures under subsurface conditions. In this study, a 2.54 cm wide and 5.08 cm long Marcellus shale core with a single, ~1 mm wide fracture held open by sand "proppant" underwent MICP-treatment at 60°C until reaching three orders of magnitude permeability reduction. Low-field nuclear magnetic resonance (LF-NMR) and X-Ray computed microtomography (μ-CT) techniques were used to assess the extent of biomineralization within the fracture. These tools revealed that while CaCO 3 precipitation occurred throughout the fracture, there was preferential precipitation around proppant, and the core sealed at the effluent end before filling most of the fracture. Both tools were able to independently calculate of the amount of solid biomineral formed inside the fracture. Furthermore, this study found that the distribution of proppant within the shale fracture was an important parameter controlling the degree of biomineralization.

clastic rock↗

Search for Organic Nanoglobules in Carbonaceous Chondrites Using Microtomography

Primitive solar materials have various organic matters. In recent years, novel organic materials called organic nanoglobules of a few hundred micrometers in typical size were discovered in carbonaceous chondrites, IDPs, and comet 81P/Wild 2. The organic globules are spherical shape and in many cases with hollow structures. Composition of the globules are mainly aromatic carbon. The isotopic anomalies of SD and 6N 15 observed in the globules indicate that they were formed from photochemical reaction to ice particles at very low temperature environment, such as molecular clouds or outer protosolar disk. Aqueous alteration of organic matters and the gamma-ray irradiation to PAH are also suggested as alternative possible formation processes. If the globules are made from organic ice particles, the hollow regions of the globules are suggested to be once filled with volatile H20-rich organic ices, while if they were formed by aqueous alteration, the hollow regions should be filled with a fluid which caused the aqueous alteration. However, fluids in the globules have not been detected so far in the previous studies. If fluids were originally preserved in the hollows, they might be lost during destructive processes of sample separation or preparation for TEM observation. X-ray computed tomography (CT) is a nondestructive method which can determine 3-D internal structures of objects. SR (synchrotron radiation)-based imaging microtomography can give submicron spatial resolution [8] and was applied to micro textures in extraterrestrial materials, such as cometary grains captured by the Stardust mission [9]. If organic globules are observed non-destructively in carbonaceous chondrites by tomography, we can check the presence of fluids in the hollows. If fluids are preserved, we may analyze chemical and isotopic compositions of the fluids. The purpose of this study is to observe organic nanoglobules using imaging tomography for future analysis.

Matsumoto, T.↗

In-Situ Synchrotron X-ray Computed Microtomography and Diffraction Investigation of Deformation and Fracture Behavior in a Laser Powder Bed Fusion Processed 316L Stainless Steel

Introduce defects into laser powder bed fusion stainless steel samples by controlling processing parameters. Perform in-situ x-ray microtomography on L-PBF stainless steel samples during plastic deformation. Relate defect characteristics and evolution to tensile behavior. Understand how processing conditions translate to initial defect characteristics. Track and evaluate defect evolution as a function of plastic deformation. Determine how deformation and fracture mechanics change as a result of AM defects.

36 MATERIALS SCIENCE↗

Evolution of Defect Properties and Texture During Tensile Deformation of Additively Manufactured 316L Stainless Steel Using In-situ Synchrotron X-ray Computed Microtomography and Diffraction

The ability of Additive Manufacturing to create complex 3D objects has attracted the attention of a wide variety of industries [1]. This in turn has led to detailed studies investigating the relationship between AM processing parameters and final part characteristics such as porosity and texture [2]. However little research has been done to study the effects of these subsequent characteristics on these parts’ performance [3]. In this study, 316L stainless steel samples were additively manufactured to have common AM defects. The samples were deformed plasticly while undergoing in-situ microtomography and diffraction measurements.

36 MATERIALS SCIENCE↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Density measurement of samples under high pressure using synchrotron microtomography and diamond anvil cell techniques

Accurate mass density information is critical in high-pressure studies of materials. It is, however, very difficult to measure the mass densities of amorphous materials under high pressure with a diamond anvil cell (DAC). Employing tomography to measure mass density of amorphous samples under high pressure in a DAC has recently been reported. In reality, the tomography data of a sample in a DAC suffers from not only noise but also from the missing angle problem owing to the geometry of the DAC. An algorithm that can suppress noise and overcome the missing angle problem has been developed to obtain accurate mass density information from such ill-posed data. The validity of the proposed methods was supported with simulations.

47 OTHER INSTRUMENTATION↗

Mjölnir: a miniature triaxial rock deformation apparatus for 4D synchrotron X-ray microtomography

An X-ray transparent experimental triaxial rock deformation apparatus, here named 'Mjölnir', enables investigations of brittle-style rock deformation and failure, as well as coupled thermal, chemical and mechanical processes relevant to a range of Earth subsurface environments. Designed to operate with cylindrical samples up to 3.2 mm outside-diameter and up to 10 mm length, Mjölnir can attain up to 50 MPa confining pressure and in excess of 600 MPa axial load. The addition of heaters extends the experimental range to temperatures up to 140°C. Deployment of Mjolnir on synchrotron beamlines indicates that full 3D datasets may be acquired in a few seconds to a few minutes, meaning full 4D investigations of deformation processes can be undertaken. Mjölnir is constructed from readily available materials and components and complete technical drawings are included in the supporting information.

47 OTHER INSTRUMENTATION↗

Effect of Tube-Based X-Ray Microtomography Imaging on the Amino Acid and Amine Content of the Murchison CM2 Chondrite

X-ray and synchrotron X-ray micro-computed tomography (micro-CT) are increasingly being used for three dimensional reconnaissance imaging of chondrites and returned extraterrestrial material prior to detailed chemical and mineralogical analyses. Although micro-CT imaging is generally considered to be a non-destructive technique since silicate and metallic minerals in chondrites are not affected by X-ray exposures at the intensities and wavelengths typically used, there are concerns that the use of micro-CT could be detrimental to the organics in carbonaceous chondrites. We recently conducted a synchrotron micro-CT experiment on a powdered sample of the Murchison CM2 carbonaceous chondrite exposed to a monochromatic high energy (approximately 48 kiloelectronvolts) total X-ray radiation dose of approximately 1 kilogray (kGy) using the Advanced Photon Source beamline 13-BMD (13-Bending Magnet-D Beamline) at Argonne National Laboratory and found that there were no detectable changes in the amino acid abundances or enantiomeric compositions in the chondrite after exposure relative to a Murchison control sample that was not exposed. However, lower energy bremsstrahlung X-rays could interact more with amino acids and other lower molecular weight amines in meteorites. To test for this possibility, three separate micro-CT imaging experiments of the Murchison meteorite using the GE Phoenix v/tome/x s 240 kilovolt microfocus high resolution tungsten target X-ray tube instrument at the American Museum of Natural History (AMNH) were conducted and the amino acid abundances and enantiomeric compositions were determined. We also investigated the abundances of the C1-C5 amines in Murchison which were not analyzed in the first study.

Microtomography Imaging↗