Search NASA⌕ Search

SEARCH · Search NASA

Results for “mobile loading unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

U.S. Light-Duty Vehicle Air Conditioning Fuel Use and Impact of Solar/Thermal Control Technologies

To reduce fuel consumption and carbon dioxide (CO2) emissions from mobile air conditioning (A/C) systems, 'U.S. Light-Duty Vehicle Greenhouse Gas Emissions and Corporate Average Fuel Economy Standards' identified solar/thermal technologies such as solar control glazings, solar reflective paint, and active and passive cabin ventilation in an off-cycle credit menu. National Renewable Energy Laboratory (NREL) researchers developed a sophisticated analysis process to calculate U.S. light-duty A/C fuel use that was used to assess the impact of these technologies, leveraging thermal and vehicle simulation analysis tools developed under previous U.S. Department of Energy projects. Representative U.S. light-duty driving behaviors and weighting factors including time-of-day of travel, trip duration, and time between trips were characterized and integrated into the analysis. In addition, U.S. weather conditions weighted based on light-duty vehicle registrations were generated and used for the analysis. Three representative vehicle types for the light-duty fleet were selected based on registration data containing vehicle size information. These key inputs were used to support a weighted parametric analysis that quantified vehicle thermal load, vehicle accessory load, and vehicle fuel use. This analysis estimates that 7.6 billion gallons of fuel a year are used in the United States for vehicle A/C, equivalent to 6.1% of the total national light-duty vehicle fuel use. This equates to 30.0 gallons/year per vehicle or 23.5 grams CO 2 per mile (g/mi) for an average U.S. light-duty vehicle. A/C is a significant contributor to national fuel use; therefore, technologies that reduce A/C loads have an opportunity to reduce fuel consumption, reduce imported oil, and improve energy security. Implementing solar control glass reduced the CO 2 emissions by 2.0 g/mi and the reduction due to solar reflective paint was 0.8 g/mi. The active and passive ventilation strategies as defined in this analysis only reduced emissions by 0.1 and 0.2 g/mi, respectively. This analysis shows the potential to reduce operational costs, A/C fuel use, and CO 2 emissions by implementing advanced vehicle climate control technologies including the solar/thermal technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sensing Electrical Networks Securely & Economically (SENSE)

The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Urban wash-off of tire wear particles

Tire wear particles (TWPs) are an important class of microplastics due to their toxicity and abundance. Because most TWPs are generated on impervious road surfaces, urban wash-off is the critical first phase of waterborne transport from their zone of production to stormwater drainage. However, little is known about the driving factors behind their mobilization. In this study, we use a rainfall simulator to investigate how surface roughness, rainfall intensity, and surface slope affect wash-off behaviors of TWPs. We also analyze how the size and shape of mobilized TWPs change over the course of simulated storm events. We found that low surface roughness, high rainfall intensity (most significant factor), and low slope result in the most rapid conveyance of TWP load. On average, large particles (>1000 µm) travelled faster than small particles (<125 µm). Particle shape explained a very small amount of variance in TWP wash-off velocity but was found to be more important under higher surface roughness conditions. In addition to wash-off velocity, we found similar conditions controlled the percent mobilization of TWPs. Low surface roughness and high rainfall intensity resulting in higher TWP wash-off rates is consistent with mineral sediment wash-off behavior. Conversely, low surface slope and large particle size leading to faster conveyance is directly opposed to mineral sediment wash-off. Our findings suggest drag-dominated flow and that sufficient runoff depth is the most important parameter governing TWP wash-off. These findings are important first steps to understanding wash-off behaviors of TWPs and informing future modeling efforts and mitigation strategies.

13 HYDRO ENERGY↗

Black Carbon at the Mt. Bachelor Observatory Field Campaign Report

This campaign was initiated to measure refractory black carbon (rBC, as defined in Schwarz et al. (2010)) at the Mt. Bachelor Observatory (MBO) using the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility single-particle soot photometer (SP2; unit 54). MBO is a high-elevation site located on the summit of Mt. Bachelor in central Oregon, USA (43.979°N, 121.687°W, 2,763 meters ASL). This site is operated by Professor Dan Jaffe’s group at the University of Washington Bothell and has been used continuously as an atmospheric observatory for the past 12 years (Jaffe et al., 2005; Gratz et al., 2014). The location of MBO allows frequent sampling of the free troposphere along with a wide array of plumes from regional and distant sources. MBO is currently supported with funding from the National Science Foundation (NSF) to the Principal Investigator (PI; D. Jaffe) via the project “Influence of Free Tropospheric Ozone and PM on Surface Air Quality in the Western U.S.” (#1447832) covering the period 03/15/2015 to 02/28/2018. The SP2 instrument from Droplet Measurement Technologies provides particle-resolved measurements of rBC mass loading, size and mass distributions, and mixing state. The SP2 was installed at MBO on 6/27/2016 and ran through 9/23/2016. Additional measurements at MBO during this campaign included carbon monoxide (CO), fine particulate matter (PM1), aerosol light scattering coefficients (σscat) at three wavelengths using a TSI nephelometer, aerosol absorption coefficients (σabs) with the Brechtel tricolor absorption photometer (TAP), aerosol number size distributions with a scanning mobility particle sizer spectrometer (SMPS), and black carbon (eBC) with an aethalometer. BC data from this campaign have been submitted to the ARM Data Archive. Black carbon (BC) is the predominant light-absorbing aerosol constituent in the atmosphere, and is estimated to exert a positive radiative forcing second only to CO 2 (Ramanathan and Carmichael, 2008). One of the largest sources of BC globally is biomass burning (BB). (Akagi et al., 2011; Andreae and Merlet, 2001; Bond et al., 2013; Bond et al., 2004; Reid et al., 2005b): a source that is likely to increase in the Western U.S. due to climate change (Dennison et al., 2014; Abatzoglon and Williams, 2016; Westerling et al., 2006). Given the likely increased role of BB aerosol in atmospheric forcing, we need to improve our understanding of the physical and optical properties of aged BB aerosol. During the SP2 deployment period at MBO we observed seven BB events, all of which originated from the Gap Fire in Northern California, which burned 33,867 acres in the Klamath National Forest (https://inciweb.nwcg.gov/incident/4997/). Heavy smoke plumes from this fire were transported to MBO from 8/29/2016 to 8/31/2016. We calculated back-trajectories using the National Oceanic and Atmospheric Administration (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, version 4 (Draxler, 1999; Draxler and Hess, 1997, 1998; Stein et al., 2015) to confirm transport from the fire locations to MBO. We identified the fire locations using moderate resolution imaging spectroradiometer (MODIS) satellite-derived active fire counts (Justice et al., 2002). Transport time for all of the BB events ranged from 8 to 32 hours.

54 ENVIRONMENTAL SCIENCES↗

Demand-Side Grid (dsgrid) TEMPO Light-Duty Vehicle Charging Profiles v2022

Simulated hourly electric vehicle charging profiles for light-duty household passenger vehicles in the contiguous United States, 2018-2050. Profiles are differentiated by scenario, county, household and vehicle types, and charging type. Data was produced in 2022 using the Transportation Energy & Mobility Pathway Options (TEMPO) model and published in demand-side grid (dsgrid) toolkit format. Data are available for three adoption scenarios: "AEO Reference Case", which is aligned with the U.S. EIA Annual Energy Outlook 2018 (linked below), "EFS High Electrification", which is aligned with the High Electrification scenario of the Electrification Futures Study (linked below), and "All EV Sales by 2035", which assumes that average passenger light-duty EV sales reach 50% in 2030 and 100% in 2035. The charging shapes are derived from two key assumptions of which data users should be aware: "ubiquitous charger access", meaning that drivers of vehicles are assumed to have access to a charger whenever a trip is not in progress, and "immediate charging", meaning that immediately after trip completion, vehicles are plugged in and charge until they are either fully recharged or taken on another trip. These assumptions result in a bounding case in which vehicles' state of charge is maximized at all times. This bounding case would minimize range anxiety, but is unrealistic from the point of view of both electric vehicle service equipment (EVSE) (i.e., charger) access, and plug-in behavior as it can result in dozens of charging sessions per week for battery electric vehicles (BEVs) that in reality are often only plugged in a few times per week.

Array↗

Chromium enhances the mechanical performance of 3d transition metal high entropy alloys

A comprehensive examination of the compositional effects on the deformation behavior of high entropy alloys (HEAs) was conducted through nanoindentation, indentation creep, and stress relaxation experiments at ambient temperature. The alloys investigated included NiCoFe, NiCoCr, NiCoCrFe, and NiCoCrFeMn, all of which underwent identical thermomechanical processing. From the experimental results, NiCoCr exhibited the highest maximum shear stress for dislocation nucleation (13 GPa) and nanoindentation hardness (3.8 GPa) among the alloys tested. It also showed the lowest stress sensitivity (0.02) and activation volume (3–4 b 3 ) under creep and stress relaxation conditions, indicative of its superior plastic flow properties. Density functional theory (DFT) calculations further revealed an uneven charge density and larger bonding-length variation in NiCoCr due to the presence of Cr, which increased lattice distortion, impeding dislocation movement. Furthermore, in this study, post-deformation microscopy using transmission electron microscopy (TEM) revealed a high density of stacking faults and twins in NiCoCr that effectively enhanced its creep strength. The results highlight the significance of specific elemental effects, particularly from Cr in this study, over configurational entropy effect (i.e., compositional complexity) in governing the deformation microstructure and mechanical properties of HEAs. Finally, these insights will be instrumental for the design and optimization of advanced alloys for load-bearing applications.

36 - MATERIALS SCIENCE↗

Atomistic Mechanisms of Stress-Dependent Molten Salt Corrosion in NiCr Alloys

Ni-based structural alloys in molten salt environments often experience simultaneous mechanical loading and corrosive attack, yet the mechanisms governing stress-corrosion interactions remain unclear. Prior studies largely emphasize tensile stress, while the role of compressive stress has received limited attention. Here, reactive molecular dynamics simulations are used to investigate the coupled effects of applied strain and corrosion in Ni 0.75 Cr 0.25 exposed to molten FLiNaK at 800 °C. A Σ5(210) grain boundary model is subjected to tensile (+4%) to compressive (−4%) uniaxial strains, and corrosion behavior is evaluated through fluorine adsorption, charge redistribution, and grain boundary evolution. Tensile strain accelerates intergranular corrosion susceptibility by reducing local atomic packing through elastic dilation and increasing excess free volume at the grain boundary, which enhances atomic mobility and salt infiltration. In contrast, compressive strain can suppress corrosion by promoting the formation of a ridge-like surface layer along the grain boundary, limiting salt access to the underlying alloy. These results provide atomistic insight into how stress states influence grain boundary corrosion in molten salts.

36 - MATERIALS SCIENCE↗

How Improved Forecasting Can Increase the Bulk Power System Value of Price-Responsive Electric Vehicle Managed Charging

Personal light-duty vehicle (LDV) electric vehicle managed charging (EVMC) can reduce power system costs by better aligning electric vehicle (EV) charging with locations and times of low energy cost or infrastructure use. The need to coordinate charging demand across thousands to millions of vehicles while preserving mobility service is a barrier to realizing the value of EVMC. Price-responsive dispatch mechanisms like time-of-use rates (TOU) and hourly real-time prices (RTP) are attractive compared to direct load control (DLC) because they only require one-way communications and local controls. However, increasing participation in price responsive mechanisms can induce costly-to-serve spikes in load and otherwise increase, rather than decrease, production costs. We quantify the ability of improved EVMC forecasting to sustain savings from price responsive mechanisms beyond the limit of 14% of LDVs actively participating observed in previous work. Perfect forecasting of price-responsive EV load makes TOU and RTP value-competitive with a low-error DLC formulation with up to 27% (within-week flexibility) to 45% or more (within-session flexibility) of LDVs participating in EVMC in an envisioned New England power system with 84% clean energy. Additional costs of implementing DLC should be no more than tens of dollars per vehicle-year if DLC is to be value-competitive with accurately forecast price-responsive EVMC for double-digit percentage shares of LDVs participating.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sparsely Dispersed CeO x ‑Stabilized Pt Nanoparticles Overcome Pt Loading–Durability Trade-Off for Highly Durable Heavy-Duty Fuel Cells

Proton-exchange-membrane fuel cells (PEMFCs) are clean and sustainable mobile power sources for transportation. Recently, their deployment in heavy-duty vehicles (HDVs) has attracted growing interest owing to their high energy scalability and lower infrastructure requirements. However, to meet the stringent requirements for efficiency and long-term durability for HDV applications, PEMFCs typically employ a relatively high platinum group metal (PGM) loading (>0.2 mg PGM /cm 2 ). This elevated PGM loading significantly increases the stack and system costs, surpassing the U.S. Department of Energy (DOE) target of $\$ 60$/kW for commercial viability. Reducing PGM loading while maintaining performance and durability remains a central challenge for HDV fuel cells. Here we exploit metal oxide–Pt interactions and utilize the strong CeO x –Pt interaction to design a CeO x @Pt catalyst structure with exceptional durability. At a low total PGM loading (0.1 mg PGM /cm 2 ), the CeO x @Pt/C catalyst demonstrates high fuel cell performance (8.8 kW/g PGM ) and stability (power retention >90%) after the challenging HDV durability testing (90,000 accelerated-stress-test cycles). With the CeO x @Pt/C catalyst, we showcase over 70% reduction in Pt cost from the M2FCT target (to $\$ 9$/kW), highlighting its promising potential for enabling stable and cost-effective fuel cell systems for heavy-duty applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-Range Transport of Biomass Burning Aerosols from Southern Africa: A Case Study Using Layered Atlantic Smoke Interactions with Clouds Observations

A case study of an incoming biomass burning aerosol plume at Ascension Island is analyzed for the peak of the 2017 fire season using satellites, reanalysis and in situ observations. Measurements from the Atmospheric Radiation Measurement Mobile Facility 1 reveal an abrupt change from relatively clean conditions (~70 parts per billion by volume of carbon monoxide) to a more polluted state (~150 parts per billion by volume of carbon monoxide). Corresponding changes in aerosol size reveal a broadening of size distributions toward larger optical diameters, consistent with the arrival of aged aerosols. Within a 24 h period, black carbon fraction increases ~500% from ~300 ng m e to ~1500 ng m 3 , while light absorption coefficients increase ~300%. Long-range transport of these aerosols is primarily confined between 2 and 5 km above sea level along the northwesterly trade winds. Our results show that the primary driver of increases in aerosol loading over Ascension Island is an intensification of the St. Helena high-pressure system (anticyclone) that leads to a weakening of trade winds and increases westward transport on its northern flank. A better understanding of the complex interactions between air quality, meteorology and long-range aerosol transport is important for future modeling studies focused on aerosol–cloud–radiation interactions over the open ocean and reducing its associated uncertainties.

aerosol size distribution↗

Surface-Initiated Atom Transfer Radical Polymerization Using Hydrogel Reactors

Atom transfer radical polymerization (ATRP) is a controlled radical polymerization method that enables the synthesis of tailored polymeric materials with low dispersity, highlighting its immense potential for green fabrication of advanced materials. However, its broader implementation is limited by challenges in product isolation, maintaining catalyst activity, and mitigating atmospheric sensitivity arising from oxygen-sensitive metal catalysts. Here, gelatin hydrogels (GHs) are introduced as a soft “reactor” matrix for interfacial ATRP, operating with minimal metal-catalyst loading while exhibiting possibly an organoreductive behavior. This strategy leverages activator regeneration via electron transfer through a ligand–metal charge-transfer (LMCT) mechanism to reduce oxidized metal catalysts within the GH network. Polymerization is evaluated by growing polymer brushes at an active interface formed between GHs swollen in monomer solution and an initiating surface, and sequential growth experiments confirmed that GH-mediated ATRP preserves living character. Under UV illumination, LMCT is activated, producing polymers both at the desired interface and within the GH bulk. UV–Vis spectroscopy revealed active reduction of Cu(II) to Cu(I) along with concentration-dependent complex formation, indicating dynamic coordination chemistry within the hydrogel. The redox-active arginine- and glutamic acid-rich gelatin backbone coordinates and reduces the metal center, enabling ATRP at ppm-level catalyst concentrations. While polymerization proceeds in GH-Cu(II) reactors, adding external mobile ligands to the GH results in longer polymer brushes. Here, the results reported here are exploratory. More experiments are needed to characterize polymer brush growth in GHs and compare it to conventional surface-initiated polymerization in solution.

Absorption↗

Role of Polymer Architecture in CO 2 Capture from Air Using Supported Poly(alkylenimine)s: Linear vs Branched Polymers

Direct air capture (DAC) of CO 2 coupled with geologic storage is a promising climate change mitigation strategy, with some applications employing amines supported on porous solids as CO 2 sorbents. While branched poly(ethylenimine) (PEI) is the standard benchmark amine material, it suffers from limited oxidative stability. Poly(propylenimine) (PPI), as an alternative, has previously demonstrated improved resistance to degradation under harsh oxidative conditions. Linear and branched PEI are commercially available, though at different molecular weights, while PPI is not commercially available. For this reason, a comparative study of all four polymers (linear PEI, branched PEI, linear PPI, branched PPI) has not been reported for DAC. In this study, we synthesize and compare low-molecular-weight (∼800 g/mol) linear (L) and branched (B) PEI and PPI supported on a model support, SBA-15 silica. These materials are evaluated for CO 2 adsorption under dry, DAC-relevant conditions (400 ppm of CO 2 , 30 °C). LPPI exhibited the highest amine efficiency at all loadings, reaching a maximum of 0.14 mmol CO 2 /mmol N, outperforming BPEI, while LPEI consistently showed the lowest uptake capacity. Temperature-programmed desorption reveals that the structure of the amine polymer impacts the CO 2 binding strength, with branched polymers displaying higher desorption energies of 102−111 kJ/mol. In situ infrared spectroscopy experiments show that all sorbents preferentially capture CO 2 as ammonium carbamate. Isobaric CO 2 uptake studies further underscore the influence of polymer mobility and support pore crowding on performance, while demonstrating the sorbents’ performance at elevated temperatures and CO 2 concentrations. All materials demonstrated good stability over 25 adsorption−desorption cycles using thermal regeneration in an inert gas purge, with only BPPI displaying a 10−11% decrease in capacity/amine efficiency during cycling, possibly due to the loss of low molecular weight, oligomeric amines. This is the first side-by-side comparison of the CO 2 sorption properties of linear and branched PEI and PPI with similar molecular weights. These findings highlight the significant role of polymer architecture in CO 2 capture efficiency and inform future designs of durable, high-performance DAC sorbents.

adsorbents↗

Solar Living House Final Technical Report

The Solar Living House is a high-performance solar-powered dwelling designed by a team of faculty and students from the University of Florida, in collaboration with Santa Fe College, the National University of Singapore, and Alachua Habitat for Humanity. The project was designed in accordance with the Solar Decathlon 2015, a research, design, education, and outreach program developed by the U.S. Department of Energy (DOE). The Solar Living House is fundamentally a house for living, centered on people and the activities of daily life while quietly introducing advanced design, construction, and engineering technologies. The 993 square-foot two-bedroom one-bath home was designed to embrace and frame an exterior courtyard space. This courtyard acts as an extension of the interior living spaces, maximizing the spatial potentials of a modest building footprint and introducing natural light into the primary living spaces of the house. Research Outcomes: The Solar Living House advances work on high-performance buildings through three principal technological innovations: wet/dry modular construction, a building automation system, and solar dehumidification systems. Wet / Dry Modular Construction: The house is designed as a series of five modules, including one that is designated as the “wet core.” The wet core consolidates the mechanical systems and bathroom into a single module to reduce plumbing runs, efficiency losses, and on-site construction time. The other four modules are designed to eliminate interior load bearing walls to allow for maximum flexibility in the reconfiguring of the space over time. The modules are designed to meet the structural challenges of both Florida’s hurricanes and California’s earthquakes. Building Automation System: The house is equipped with an integrated building automation system, allowing the houses environmental systems, lights, security systems, and smoke detectors to be programmed, monitored, and controlled through any mobile or computing device. These systems allow for more precise calibrations of temperature/humidity/lighting to correspond with user needs and preferences, minimizing energy losses with economical night- or day-time setbacks. Solar Dehumidification System: The most significant technological innovation in the Solar Living House is the solar thermal dehumidification system. This system generates hot water through two rooftop-mounted evacuated tube solar thermal collectors. The hot water is used to continually dry a regenerative solid desiccant material, typically white silica gel. The solid desiccant is used to adsorb moisture and humidity from the air without additional mechanical cooling. This strategy allows humidity to be modulated independently of air temperature, providing greater thermal comfort and reducing the opportunity for the growth of mold spores within the house while also reducing the overall energy consumption of the HVAC system. Economic Feasibility: The team set aggressive goals for affordability, targeting a construction cost of $138,710. An independent professional cost estimator determined the overall project costs, as designed, would be $333,799, or $336.15 per square foot of finished floor area. This is more than 2.4 times the target construction cost. By comparison, the average construction cost for a home in the United States in 2015 was $289,415, or $103.29 per square foot of finished floor area. Following work on the Solar Living House, team leaders incorporated many of its objectives into a net-zero energy home on a site in Gainesville, Florida. This site-built home avoided many of the constraints and complications of modular construction necessitated by the Solar Decathlon, allowing it to be built for a much more modest budget. This two-bedroom two bath 1,800 square foot home was constructed for $135.39 per square foot, including active photovoltaic solar systems, careful attention to continuous air barriers, increased insulation levels, and permanent site constructions. This project suggest that high-performance buildings can be realized for more modest budgets. Public Benefits: Work on the Solar Living House and Solar Decathlon 2015 offered our student team unparalleled learning opportunities. Because of the duration of the project, a number of students participated at different points in their education, from first year undergraduates all the way through to advanced graduate students. The opportunity for collaboration with students and faculty from the National University of Singapore was also extraordinary, allowing for a sharing of technical knowledge and cultural exchange. The wider public has benefited from this work as its findings have been shared through public presentations and publications. It serves as a useful stepping stone along the path towards affordable, high-performance buildings.

14 SOLAR ENERGY↗

Waste Management Processing Projects in the PRC - 16551

EnergySolutions continues to provide waste treatment solutions in the Peoples Republic of China (PRC). In 2015 ES had completed installation of systems at two different Nuclear power sites (Haiyang, an AP-1000{sup TM} site and Yangjiang, a CPR1000 site). This paper discusses progress on these two projects, and provides new information regarding the operation of the systems. The Yangjiang project became operational in the fall of 2015 while the Haiyang project will be done is nearly done with commissioning and is waiting for reactor operations. Haiyang Project: In the Shandong Province on China's northeast coast, EnergySolutions, as part of a consortium with China Power Investment (CPI) and Yuanda Environmental Protection Engineering Company (a PRC state-owned company), has designed and constructed the site's Site Rad Waste Treatment Facility (SRTF). The SRTF provides solid waste processing services for up to 8 AP-1000s{sup TM}. The SRTF performs the following functions: 1. Five year storage for HICs containing spent resin and filters from the nuclear power plants' waste liquid systems (WLS); 2. Sorting and Compaction System for solid waste generated from Nuclear Power Plant (NPP) operations. This system implements: a) Real time radiography to screen 200 liter waste drums for prohibited items, b) Pre-compaction, c) High Resolution Gamma Spectrophotometry (HRGS) for waste characterization, d) Supercompaction, e) Solidification of compacted drums inside overpack drums which are filled with 60 MPa compressive strength grout, and f) Automatic drum lidding which crimps the drum lid to the drum body. 3. Laundry services for NPP anti-contamination clothing. 4. At the nuclear islands, EnergySolutions is providing mobile liquid waste processing systems that utilize EnergySolutions Advanced Liquid Processing System ALPS{sup TM}/Advanced Injection Method System AIM{sup TM} processing systems to supplement the NPP's WLS system when radionuclide concentrations exceed release criteria. The spent resins and filters from the nuclear power plants are placed in EnergySolutions supplied HICs, dewatered using EnergySolutions Self Engaging Dewatering System (SEDS{sup TM}), and then placed in EnergySolutions 8-120B Type B cask for the transport of the HIC between the NPP and the SRTF and, ultimately, to a disposal site once it is ready for operations Yangjiang Project: EnergySolutions is providing liquid waste treatment system (TEU) and solid waste treatment system (TES) for Yangjiang units 3 and 4 for the China Nuclear Power Engineering Company (CNPEC). The Yangjiang site is located approximately 300 kilometers west of Hong Kong. The TEU system processes floor drain, chemical drain, and process drain tanks liquids to achieve a release concentration less than 37 Bq/l. The TES system receives spent resin and filters into HIC containers which are dewatered and subsequently transported to the Yangjiang sites QT building where they are stored for a period of up to 5 years or until a disposal site are available. TEU (Liquid waste treatment) consists of the following unit operations: - ALPS{sup TM}/AIM{sup TM} system, which includes two separate 8 vessel water treatment systems that consist of granular activated carbon (GAC), cation, anion ion and mixed bed media ion exchange (IX) columns; and: - A reverse osmosis system for final polishing, - TES (solid waste system), - SEDS (Self Engaging Dewatering System), - Shielding for the loading and storage of HICs, - Shielded transport container for the transfer of HIC to the QT building for storage, - Shielded transfer bell for the transport of spent filters from the NPP operating area to HIC. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual design of minor actinides burner with an accelerator-driven subcritical system.

In the environmental impact study of the Yucca Mountain nuclear waste repository, the limit of spent nuclear fuel (SNF) for disposal is assessed at 70,000 metric tons of heavy metal (MTHM), among which 63,000 MTHM are the projected SNF discharge from U.S. commercial nuclear power plants though 2011. Within the 70,000 MTHM of SNF in storage, approximately 115 tons would be minor actinides (MAs) and 585 tons would be plutonium. This study describes the conceptual design of an accelerator-driven subcritical (ADS) system intended to utilize (burn) the 115 tons of MAs. The ADS system consists of a subcritical fission blanket where the MAs fuel will be burned, a spallation neutron source to drive the fission blanket, and a radiation shield to reduce the radiation dose to an acceptable level. The spallation neutrons are generated from the interaction of a 1 GeV proton beam with a lead-bismuth eutectic (LBE) or liquid lead target. In this concept, the fission blanket consists of a liquid mobile fuel and the fuel carrier can be LBE, liquid lead, or molten salt. The actinide fuel materials are dissolved, mixed, or suspended in the liquid fuel carrier. Therefore, fresh fuel can be fed into the fission blanket to adjust its reactivity and to control system power during operation. Monte Carlo analyses were performed to determine the overall parameters of an ADS system utilizing LBE as an example. Steady-state Monte Carlo simulations were studied for three fission blanket configurations that are similar except that the loaded amount of actinide fuel in the LBE is either 5, 7, or 10% of the total volume of the blanket, respectively. The neutron multiplication factor values of the three configurations are all approximately 0.98 and the MA initial inventories are each approximately 10 tons. Monte Carlo burnup simulations using the MCB5 code were performed to analyze the performance of the three conceptual ADS systems. Preliminary burnup analysis shows that all three conceptual ADS systems consume about 1.2 tons of actinides per year and produce 3 GW thermal power, with a proton beam power of 25 MW. Total MA fuel that would be consumed in the first 10 years of operation is 9.85, 11.80, or 12.68 tons, respectively, for the systems with 5, 7, or 10% actinide fuel particles loaded in the LBE. The corresponding annual MA fuel transmutation rate after reaching equilibrium at 10 years of operation is 0.83, 0.94, or 1.02 tons/year, respectively. Assuming that the ADS systems can be operated for 35 full-power years, the total MAs consumed in the three ADS systems are 30.6, 35.3, and 37.2 tons, respectively. For the three configurations, it is estimated that 3.8, 3.3, or 3.1 ADS system units are required to utilize the entire 115 tons of MA fuel in the SNF inventory, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploratory Ice Nucleation Measurements at Oliktok Field Campaign Report

Ice nucleating particles (INPs)—such as mineral dust and bacteria (1)—are a crucial source of seeds for cloud ice crystal formation, and can subsequently impact cloud radiative properties, lifetime, and precipitation formation processes (2-4). The presence of such particles in the atmosphere can be rare, but large concentrations are not required to have substantial impacts on cloud microphysics (3). However, knowledge of INPs, particularly in the Arctic, is limited due to the dearth of measurements in time and space. It is especially important to evaluate the sources and efficiency of INPs in the Arctic due to the role mixed-phase clouds play in facilitating the surface energy budget and thus energy reaching the sea ice and snow surfaces (4, 5). The purpose of this campaign, called INPOP (Ice Nucleating Particles at Oliktok Point), is to address the issue of limited information of Arctic INPs by providing time- and size-resolved INP concentrations over the course of a 3-month springtime campaign. This period is subject to Arctic haze, whereby pollutants from mid-latitudes are frequently transported to the Arctic and influence the relatively clean Arctic atmosphere (6-9). One unique aspect of this study is that the measurements were conducted at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility third ARM Mobile Facility (AMF3) in Oliktok Point, North Slope of Alaska (NSA), which is located in the northwest edge of the Prudhoe Bay oilfield. Typically, oil and natural gas extraction emissions are not thought to serve as a significant source of INPs, since naturally produced primary aerosols are the most efficient and abundant INPs (e.g., 1). However, the goal of INPOP was to evaluate INPs in the context of supporting aerosol and meteorological observations to assess: (1) if local industrial activities due to the oilfield operations can serve as a source of INPs (e.g., such as road dust from routine vehicular operations) and (2) if other regional or long-range transported sources impact a polluted Arctic location by introducing higher concentrations of more efficient INPs (e.g., transport of primary biological aerosol particles (PBAPs) from open ocean water or Arctic haze INPs). Unlike other Arctic coastal locations in the spring, Oliktok Point has a distinct combination of aerosol sources including long-range transported haze, regional/local marine emissions, and the local oilfield activities. Ground-based, immersion-mode, ice nucleation measurements were conducted on samples collected at the AMF3 in Oliktok Point from 1 March to 31 May, 2017. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D, had particle size cuts at 2.96, 1.21, 0.34, and 0.15 μm particle diameter. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank spot is created on the PFA to separate daily samples. The pump typically pulled 25 lpm at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 36,000 total L of air per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and a new disc was installed by the ARM operators. Discs were stored frozen after collection until the end of the study.

54 ENVIRONMENTAL SCIENCES↗

Phosphate-modulated transformation of Sb(V)-bearing ferrihydrite under microbial iron- and sulfate-reducing conditions

Antimony (Sb) is a toxic metalloid that poses environmental risks in terrestrial and aquatic systems. The fate of the Sb(V) oxyanion, Sb(OH) 6 − , is governed by complex biogeochemical processes, including immobilization by ferric (Fe(III)) oxides, reduction by sulfide, and the less-explored competitive adsorption with other anions such as phosphate (PO 4 3− ). Here, this study investigates the interplay between such mechanisms in controlling the behavior of Sb(V) associated with ferrihydrite (Fh) under Fe(III)- and sulfate-reducing conditions, with a particular emphasis on the role of phosphate in influencing Sb(V) mobility and transformation. Anoxic reactors that contained Sb(V)-coprecipitated Fh, varying PO 4 3− concentrations (0, 0.2, and 2 mM), and sulfate, were inoculated with a microbial community sourced from Sb-contaminated soil. Additionally, abiotic reactors with either Sb(V)-adsorbed or Sb(V)-coprecipitated Fh and different PO 4 3− loadings (0–100 mM) were created to investigate the competitive adsorption mechanisms in the absence of microbial activity. Results from the abiotic reactors suggest that Sb(V) is likely incorporated into the Fh structure, with only minor amounts remaining surface-bound and extractable by PO 4 3− . In the biotic reactors, microbial Fe(III) and sulfate reduction were more extensive in the presence of PO 4 3− . At 0.2 mM PO 4 3− , microbial activity transformed Fh into siderite and led to the complete reduction of Sb(V) to Sb(III) as stibnite (Sb 2 S 3 ). At 2 mM PO 4 3− , the greater coverage by PO 4 3− stabilized Fh and decreased the extent of both Fe(III) and Sb(V) reduction, and shifted the reduced products to mackinawite and Sb(III) adsorbed onto Fh, in addition to stibnite formation. This study demonstrates that while PO 4 3− may not directly compete with Sb(V) for sorption sites, it can influence Sb mobility in Fe(III)- and sulfate-reducing environments by enhancing microbial activity and altering the mineralization pathways.

Microbial Fe(III) and sulfate reduction↗

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗