Search NASA⌕ Search

SEARCH · Search NASA

Results for “mode extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Characterization of Asymmetric Coplanar Waveguide Discontinuities

A general technique to characterize asymmetric coplanar waveguide (CPW) discontinuities with air bridges where both the fundamental coplanar and slotline modes may be excited together is presented. First, the CPW discontinuity without air bridges is analyzed using the space-domain integral equation (SDIE) approach. Second, the parameters (phase, amplitude, and wavelength) of the coplanar and slotline modes are extracted from an amplitude modulated-like standing wave existing in the CPW feeding lines. Then a 2n x 2n generalized scattering matrix of the n-port discontinuity without air bridges is derived which includes the occurring mode conversion. Finally, this generalized scattering matrix is reduced to an n x n matrix by enforcing suitable conditions at the ports which correspond to the excited slotline mode. For the purpose of illustration, the method is applied to a shielded asymmetric short-end CPW shunt stub, the scattering parameters of which are compared with those of a symmetric one. Experiments are performed on both discontinuities and the results are in good agreement with theoretical data. The advantages of using air bridges in CPW circuits as opposed to bond wires are also discussed.

Dib, Nihad I.↗

Comparing Free-Free and Shaker Table Model Correlation Methods Using Jim Beam

Finite element model correlation as part of a spacecraft program has always been a challenge. For any NASA mission, the coupled system response of the spacecraft and launch vehicle can be determined analytically through a Coupled Loads Analysis (CLA), as it is not possible to test the spacecraft and launch vehicle coupled system before launch. The value of the CLA is highly dependent on the accuracy of the frequencies and mode shapes extracted from the spacecraft model. NASA standards require the spacecraft model used in the final Verification Loads Cycle to be correlated by either a modal test or by comparison of the model with Frequency Response Functions (FRFs) obtained during the environmental qualification test. Due to budgetary and time constraints, most programs opt to correlate the spacecraft dynamic model during the environmental qualification test, conducted on a large shaker table. For any model correlation effort, the key has always been finding a proper definition of the boundary conditions. This paper is a correlation case study to investigate the difference in responses of a simple structure using a free-free boundary, a fixed boundary on the shaker table, and a base-drive vibration test, all using identical instrumentation. The NAVCON Jim Beam test structure, featured in the IMAC round robin modal test of 2009, was selected as a simple, well recognized and well characterized structure to conduct this investigation. First, a free-free impact modal test of the Jim Beam was done as an experimental control. Second, the Jim Beam was mounted to a large 20,000 lbf shaker, and an impact modal test in this fixed configuration was conducted. Lastly, a vibration test of the Jim Beam was conducted on the shaker table. The free-free impact test, the fixed impact test, and the base-drive test were used to assess the effect of the shaker modes, evaluate the validity of fixed-base modeling assumptions, and compare final model correlation results between these boundary conditions.

Modal Test↗

Laser Doppler vibrometry for piezoelectric coefficient ($d_{33}$) measurements in irradiated aluminum nitride

Sensors used for experiments in advanced reactors must survive in harsh environments. Few material systems can be used to construct sensors viable for extreme conditions. Aluminum nitride (AlN) is one such material because it has high thermal stability and radiation resistance and sustains good piezoelectric and dielectric properties at high temperatures. In this work, the piezoelectric coefficient $d_{33}$ of the AlN single-crystal with thermal and irradiation damage was investigated using an indirect method with a laser Doppler vibrometer (LDV). Surface electrodes were deposited on the AlN samples, and the vibration response of the samples to an applied voltage was monitored using the LDV as a function of the excitation frequency. The $d_{33}$ estimation was based on the excitation voltage and the thickness-mode displacement extracted from the LDV measurements. Further, six AlN substrates were irradiated with 8 MeV Al 2+ at three fluences (10 15 , 10 16 , and 10 17 ions/cm 2 ) and two temperatures (300 °C and 500 °C). The $d_{33}$ for the six irradiated samples and one pristine sample were measured, and the measurement uncertainty was estimated based on five repeated tests. All samples were also measured by a commercial piezometer for comparison. The experimental results demonstrate that the piezoelectric coefficients obtained by LDV were about 0.8–1.16 pm/V lower than those obtained by the piezometer. With the compensation of the clamping effect, the corrected LDV values are similar to the piezometer results. Both show similar trends in all samples, which validates the feasibility of the proposed method for $d_{33}$ measurement. Based on the LDV results, the irradiated samples show a 12%–22% decrease in $d_{33}$ compared with the pristine samples. The samples irradiated under the same fluence at a higher temperature (500 °C) demonstrated a lower $d_{33}$ than those at 300 °C. The effect of the retro-reflective tape, sample temperature, and sample size on the $d_{33}$ measurement were also studied.

36 MATERIALS SCIENCE↗

Measurement of deuterium density profiles in the H-mode steep gradient region using charge exchange recombination spectroscopy on DIII-D

Recent completion of a thirty two channel main-ion (deuterium) charge exchange recombination spectroscopy (CER) diagnostic on the DIII-D tokamak enables detailed comparisons between impurity and main-ion temperature, density, and toroidal rotation. In a H-mode DIII-D discharge, these new measurement capabilities are used to provide the deuterium density profile, demonstrate the importance of profile alignment between Thomson scattering and CER diagnostics, and aid in determining the electron temperature at the separatrix. Sixteen sightlines cover the core of the plasma and another sixteen are densely packed towards the plasma edge, providing high resolution measurements across the pedestal and steep gradient region in H-mode plasmas. Extracting useful physical quantities such as deuterium density is challenging due to multiple photoemission processes. Finally, these challenges are overcome using a detailed fitting model and by forward modeling the photoemission using the FIDASIM code, which implements a comprehensive collisional radiative model. Published by AIP Publishing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SPITZER/IRS 5-35 {mu}m LOW-RESOLUTION SPECTROSCOPY OF THE 12 {mu}m SEYFERT SAMPLE

We present low-resolution 5.5-35 {mu}m spectra for 103 galaxies from the 12 {mu}m Seyfert sample, a complete unbiased 12 {mu}m flux limited sample of local Seyfert galaxies selected from the IRAS Faint Source Catalog, obtained with the Infrared Spectrograph (IRS) on-board Spitzer Space Telescope. For 70 of the sources observed in the IRS mapping mode, uniformly extracted nuclear spectra are presented for the first time. We performed an analysis of the continuum emission, the strength of the polycyclic aromatic hydrocarbon (PAH) and astronomical silicate features of the sources. We find that on average, the 15-30 {mu}m slope of the continuum is ({alpha}{sub 15-30}) = -0.85 {+-} 0.61 for Seyfert 1s and -1.53 {+-} 0.84 for Seyfert 2s, and there is substantial scatter in each type. Moreover, nearly 32% of the Seyfert 1s, and 9% of the Seyfert 2s, display a peak in the mid-infrared spectrum at 20 {mu}m, which is attributed to an additional hot dust component. The PAH equivalent width decreases with increasing dust temperature, as indicated by the global infrared color of the host galaxies. However, no statistical difference in PAH equivalent width is detected between the two Seyfert types, 1 and 2, of the same bolometric luminosity. The silicate features at 9.7 and 18 {mu}m in Seyfert 1 galaxies are rather weak, while Seyfert 2s are more likely to display strong silicate absorption. Those Seyfert 2s with the highest silicate absorption also have high infrared luminosity and high absorption (hydrogen column density N{sub H} > 10{sup 23} cm{sup -2}) as measured from the X-rays. Finally, we propose a new method to estimate the active galactic nucleus contribution to the integrated 12 {mu}m galaxy emission, by subtracting the 'star formation component in the Seyfert galaxies, making use of the tight correlation between PAH 11.2 {mu}m luminosity and 12 {mu}m luminosity for star-forming galaxies.

99 GENERAL AND MISCELLANEOUS↗

Influence of triangularity on the plasma response to resonant magnetic perturbations

The effect of the axisymmetric plasma shape on the non-axisymmetric plasma response to resonant magnetic perturbations is investigated in experiment and modeling for the DIII-D, EAST and ASDEX Upgrade tokamaks. Systematically modeling the effect of the triangularity, whilst keeping other equilibrium quantities largely unchanged, reveals that the plasma response is strongly suppressed at high triangularity compared to that at low triangularity. This is validated through targeted comparison with experiments at DIII-D, EAST, and ASDEX Upgrade. DIII-D and EAST magnetic measurements are used to validate simulations, while at ASDEX Upgrade the plasma edge displacement is measured. Both experiments and modeling find a reduced magnetic plasma response on the high-field side at high triangularity across devices. Multi-modal analysis of the simulation results extracts the mode structure and applied spectrum dependence of each mode. The amplitude of the dominant mode reveals similar trends with the edge resonance and radial displacement near the X-point, which suggests that the multi-mode plasma response provides another way to understand the edge localized mode (ELM) control physics. The plasma response is strongly reduced at high triangularity compared to that at low triangularity, which implies different ELM control effects as shaping is varied. Furthermore, these findings indicate that the plasma shape should be taken into consideration when designing an RMP-ELM control strategy in experiment, and that predictive plasma response calculations can be used to maximize access to RMP-ELM control in future devices by maximizing the coupling between coils and the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lensing covariance on cut sky and SPT - P l a n c k lensing tensions

We investigate correlations induced by gravitational lensing on simulated cosmic microwave background data of experiments with an incomplete sky coverage and their effect on inferences from the South Pole Telescope (SPT) data. These correlations agree well with the theoretical expectations, given by the sum of supersample and intrasample lensing terms, with only a typically negligible ~5 % discrepancy in the amplitude of the supersample lensing effect. Including these effects we find that lensing constraints are in 3.0 σ or 2.1 σ tension between the SPT polarization measurements and Planck temperature or lensing reconstruction constraints respectively. If the lensing-induced covariance effects are neglected, the significance of these tensions increases to 3.5 σ or 2.5 σ . Using the standard scaling parameter AL substantially underestimates the significance of the tension once other parameters are marginalized over. By parameterizing the supersample lensing through the mean convergence in the SPT footprint, we find a hint of underdensity in the SPT region. We also constrain extra sharpening of the cosmic microwave background acoustic peaks due to missing smoothing of the peaks by supersample lenses at a level that is much smaller than the lens sample variance. Finally, we extend the usual “shift in the means” statistic for evaluating tensions to non-Gaussian posteriors, generalize an approach to extract correlation modes from noisy simulated covariance matrices, and present a treatment of correlation modes not as data covariances but as auxiliary model parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and synthetic CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable at capturing systematic changes, enabling dosimetric consequences to be projected once trends are established early in a treatment course, or based on population models.

60 APPLIED LIFE SCIENCES↗

Shock spectra applications to a class of multiple degree-of-freedom structures system

The demand on safety performance of launching structure and equipment system from impulsive excitations necessitates a study which predicts the maximum response of the system as well as the maximum stresses in the system. A method to extract higher modes and frequencies for a class of multiple degree-of-freedom (MDOF) Structure system is proposed. And, along with the shock spectra derived from a linear oscillator model, a procedure to obtain upper bound solutions for maximum displacement and maximum stresses in the MDOF system is presented.

Hwang, Shoi Y.↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗

Modal Test of the NASA Mobile Launcher at Kennedy Space Center

The NASA Mobile Launcher (ML), located at Kennedy Space Center (KSC), has recently been modified to support the launch of the new NASA Space Launch System (SLS). The ML is a massive structure—consisting of a 345-foot tall tower attached to a two-story base, weighing approximately 10.5 million pounds—that will secure the SLS vehicle as it rolls to the launch pad on a Crawler Transporter, as well as provide a launch platform at the pad. The ML will also provide the boundary condition for an upcoming SLS Integrated Modal Test (IMT). To help correlate the ML math models prior to this modal test, and allow focus to remain on updating SLS vehicle models during the IMT, a ML-only experimental modal test was performed in June 2019. Excitation of the tower and platform was provided by five uniquely-designed test fixtures, each enclosing a hydraulic shaker, capable of exerting thousands of pounds of force into the structure. For modes not that were not sufficiently excited by the test fixture shakers, a specially-designed mobile drop tower provided impact excitation at additional locations of interest. The response of the ML was measured with a total of 361 accelerometers. Following the random vibration, sine sweep vibration, and modal impact testing, frequency response functions were calculated and modes were extracted for three different configurations of the ML in 0 Hz to 12 Hz frequency range. This paper will provide a case study in performing modal tests on large structures by discussing the Mobile Launcher, the test strategy, an overview of the test results, and recommendations for meeting a tight test schedule for a large-scale modal test.

Hydraulic shakers↗

Feasibility Study to Extract Artemis-1 Fixed Base Modes While Mounted on a Dynamically Active Mobile Launch Platform

There are several challenges associated with the scheduled integrated modal test (IMT)of the Space Launch System (SLS) Artemis-1flight vehicle mounted on the mobile launcher (ML). While the goal of the test is to characterize the Artemis-1, the inclusion of the ML as the support stand for the test means that the entire system must be well characterized. A considerable amount of effort and schedule will have to be devoted to understanding both the test stand (the ML) and the Artemis-1 flight vehicle, and there is a risk that the effort may not be completed in time for a successful launch. NASA has requested that alternative methods be investigated to generate test results that can remove the effects of the ML from the test. ATA Engineering, Inc., (ATA)was given a reduced model f theArtemis-1 flight vehicle’s IMT configuration containing the candidate set of accelerometers and interface degrees of freedom (DOF). The model was used to determine how well ATA’s fixed base correction technique is able to estimate fixed base modes from test data collected on the IMT. This paper presents the fixed base correction method results.

modal testing↗

A CYCLOTRON CONCEPT TO SUPPORT ISOTOPE PRODUCTION FOR SCIENCE AND MEDICAL APPLICATIONS

In August of 2009, the Nuclear Science Advisory Committee (NSAC) recommended a variable-energy, high-current multi-particle accelerator for the production of medical radioisotopes. The Oak Ridge National Laboratory is developing a technical concept for a 70 MeV dual-extraction multi-particle cyclotron that will meet the needs identified in the NSAC report. The cyclotron, which will be located at the Holifield Radioactive Ion Beam Facility (HRIBF), will operate on a 24/7 basis and will provide approximately 6000 hours per year of quality beam time for both the production R&D and production of medical and industrial radioisotopes. The proposed cyclotron will be capable of accelerating dual beams of 30 to 70 MeV H at up to 750 A, and up to 50 A of 15-35 MeV D , 35 MeV H2, and 70 MeV -particles. In dual-extraction H mode, a total of 750 A of 70 MeV protons will be provided simultaneously to both HRIBF and Isotope Production Facility. The isotope facility will consist of two target stations: a 2 water-cooled station and a 4 water-cooled high-energy-beam research station. The multi-particle capability and high beam power will enable research into new regimes of accelerator-produced radioisotopes, such as 225Ac, 211At, 68Ge, and 7B. The capabilities of the accelerator will enable the measurement of excitation functions, thick target yield measurements, research in high-power-target design, and will support fundamental research in nuclear and radiochemistry.

cyclotron↗

System and method for automated extraction of high resolution structural dynamics from video

A method for extracting vibrational modes of a structure includes: receiving a plurality of video frames, each of the video frames including a plurality of pixels; decomposing each of the video frames on a plurality of spatial scales in accordance with complex steerable pyramid filters to obtain a filter response for each of the spatial scales; computing a plurality of local phases of the pixels of each frame; removing a temporal mean from each frame to obtain a plurality of factored vibration motion functions; performing principal component analysis on the factored vibration motion functions to obtain principal components; blind source separating the principal components to compute a plurality of modal coordinates; computing frequency and damping ratios in accordance with the modal coordinates; and outputting the computed frequency and damping ratios.

42 ENGINEERING↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

The Leading Modes of Asian Summer Monsoon Variability as Pulses of Atmospheric Energy Flow

Monsoon rainfall anomalies are often organized into dynamical modes that are more predictable than rainfall at specific locations. Here a linear response function (LRF) is constructed to extract the neutral modes (NM) of the dynamical atmospheric system and their optimal forcing that govern precipitation variability, providing a dynamical underpinning for the empirically derived, recurrent rainfall patterns. The leading mode (NM1) features a shift in the Atlantic ITCZ, a drying over the Indian Ocean and Indian subcontinent, and a “South-Flood-North Drought (SFND)” pattern over eastern China, a pattern inferable from changes in the atmospheric energy flow forced by the corresponding optimal forcing and further enhanced by the water vapor and cloud feedbacks. Moreover, the slow evolving component of the NM1 in response to CO2 forcing can be skillfully predicted by running the ocean heat uptake through the LRF, implicating a deterministic ocean dynamic source for the NM1-like trend under climate warming.

monsoon mode of variability, EBM, climate change, ↗