Search NASA⌕ Search

SEARCH · Search NASA

Results for “modular symmetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

59 records · Page 4

CFD Analysis of Modular Thrusters Performance

The effective performance of modular thrusters in an aerospike configuration is difficult to determine. Standard analytical tools are applicable to conventional nozzle shapes, but are limited when applied to an aerospike nozzle (An aerospike nozzle is an altitude compensating external nozzle). Three baseline nozzle shapes are derived using standard analytical procedures. The baseline nozzle sizes are restricted to fill a volume envelope. The three shapes are an axi-symmetric round nozzle, a two dimensional planar square exit nozzle, and a super elliptic round to nearly square nozzle. The integrated (thruster/aerospike) performance of the three nozzles is determined through the use of three dimensional viscous computational fluid dynamic (CFD) calculation where complex features of the flow field can be accurately captured. The resulting installed performance is then used to evaluate the efficiency of these nozzle shapes for aerospike applications. The determination of effective performance of a thruster nozzle integrated into an aerospike nozzle require the solution of the three dimensional turbulent Navier-Stokes equations. The model used in this study consisted of two zones; one of the upstream thruster cowl surface so freestream conditions can be accurately predicted, and two, the aerospike surface beginning with the thruster outflow and extending to the end of the aerospike surface. The numerical grid consisted of over 120,000 nodes and used symmetry on the thruster centerline and edge. A two species non-reacting chemistry model was used to capture the variation of fluid properties between the hot plume base and freestream air. From the results of the three baseline nozzle aerospike calculations, the effictive performance of the nozzle was determined. The flow fields of these calculations do show some variation between the cases. Recirculation zones on the cowl surface is predicted for the two dimensional planar nozzle and a smaller one for the super elliptic nozzle. The recirculation is caused by the strong pressure gradient between the plume and freestream flows. The axi-symmetric nozzle results indicate recirculation zones on the thruster face. These recirculation zones smooth the pressure gradient between the plume and freestream flow limiting the formation of recirculation on the cowl surface. Thruster to thruster interaction is evident for the axi-symmetric and supper elliptic calculation while the two dimensional planar nozzle did not have any lateral expansion in the nozzle, so thruster to thruster interaction is limited. The integrated performance results, at the altitude choosen, show very little variation between the three thruster shapes. This result allows for nozzle shape determination based on additional considerations (thermal, structural, weight) besides performance.

Ungewitter, Ronald J.↗

Universality of Rényi Entropy in Conformal Field Theory

We use the thermal effective theory to prove that, for the vacuum state in any conformal field theory in 𝑑 dimensions, the 𝑛th Rényi entropy 𝑆$^{(𝑛)}_{𝐴}$ behaves as 𝑆$^{(𝑛)}_{𝐴}$ = [𝑓⁡/(2⁢𝜋⁢𝑛) 𝑑−1 ]⁢[Area⁡(∂𝐴)/(𝑑−2)⁢𝜀 𝑑−2 ]⁢(1+𝑂⁡(𝑛)) in the 𝑛 → 0 limit when the boundary of the entanglement domain 𝐴 is spherical with the UV cutoff 𝜀. The theory dependence is encapsulated in the cosmological constant 𝑓 in the thermal effective action. Using this result, we estimate the density of states for large eigenvalues of the modular Hamiltonian for the domain 𝐴. In two dimensions, we can use the hot spot idea, which describes the effective action in the high-temperature limit when the temperature is position-dependent, to derive more powerful formulas valid for arbitrary positive 𝑛. We discuss the difference between two and higher dimensions and clarify the applicability of the hot spot idea. We also use the thermal effective theory to derive an analog of the Cardy formula for boundary operators in higher dimensions.

Conformal field theory↗

3d TQFTs from Argyres–Douglas theories

We construct a new class of three-dimensional topological quantum field theories (3d TQFTs) by considering generalized Argyres–Douglas theories on S 1 × M 3 with a non-trivial holonomy of a discrete global symmetry along the S 1 . For the minimal choice of the holonomy, the resulting 3d TQFTs are non-unitary and semisimple, thus distinguishing themselves from theories of Chern–Simons and Rozansky–Witten types respectively. Changing the holonomy performs a Galois transformation on the TQFT, which can sometimes give rise to more familiar unitary theories such as the ${\left({G}_{2}\right)}_{1}$ and ${\left({F}_{4}\right)}_{1}$ Chern–Simons theories. Our construction is based on an intriguing relation between topologically twisted partition functions, wild Hitchin characters, and chiral algebras which, when combined together, relate Coulomb branch and Higgs branch data of the same 4d $\mathcal{N}=2$ theory. Finally, we test our proposal by applying localization techniques to the conjectural $\mathcal{N}=1$ UV Lagrangian descriptions of the (A 1 , A 2 ), (A 1 , A 3 ) and (A 1 , D 3 ) theories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rare multinucleon decays with the full data sets of the M AJORANA D EMONSTRATOR

The M AJORANA D EMONSTRATOR was an ultra-low-background experiment designed for neutrinoless double-beta decay (0⁢𝜈⁢𝛽⁢𝛽) investigation in 76 Ge . Located at the Sanford Underground Research Facility in Lead, South Dakota, the D EMONSTRATOR utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to ∼88% in 76 Ge ), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Here, our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of 1.83 × 10 26 yr (90% confidence level) for 76 Ge (𝑝⁢𝑝⁢𝑝) → 73 Cu 𝑒 + ⁢𝜋 + ⁢𝜋 + and 76 Ge (𝑝⁢𝑝⁢𝑛) → 73 Zn 𝑒 + ⁢𝜋 + . The partial lifetime limit for the fully inclusive triproton decay mode of 76 Ge is found to be 2.1×10 25 yr. Furthermore, we have updated limits for corresponding multinucleon decays.

baryon & lepton number symmetries↗