PV Module Operating Temperature Model Equivalence and Parameter Translation.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A method of encapsulating a thermoelectric device and its associated thermoelectric elements in an inert atmosphere and a thermoelectric device fabricated by such method are described. These thermoelectric devices may be intended for use under conditions which would otherwise promote oxidation of the thermoelectric elements. The capsule is formed by securing a suitably-sized thin-walled strip of oxidation-resistant metal to the ceramic substrates which support the thermoelectric elements. The thin-walled metal strip is positioned to enclose the edges of the thermoelectric device and is secured to the substrates using gap-filling materials. The strip, substrates and gap-filling materials cooperatively encapsulate the thermoelectric elements and exclude oxygen and water vapor from atmospheric air so that the elements may be maintained in an inert, non-oxidizing environment.
Several studies have found indications that PV degradation may increase in hotter climates. We show in this paper that degradation does correlate to higher module temperatures, but that these temperatures are significantly affected by the module mounting and. The mechanisms of degradation vary with module technology and quality. Using data from different HIT module installations we were able to extract an activation energy that is consistent with hydrogen passivation layer degradation. In addition, we show that low degradation in hot climates can be achieved for Al-BSF technology if properly installed to reduce heat transfer in order to thermally decouple the modules from the roof. We also found that monofacial and bifacial PERC module degradation is in line with historical degradation rates of Al-BSF.
An emissions control system includes a temperature determination module and an emissions control module. The temperature determination module determines a first temperature of a heater element of a diesel particulate filter (DPF) assembly in an exhaust system and determines a second temperature of a catalyst of the DPF assembly. The emissions control module selectively activates the heater element, selectively initiates a predefined combustion process in an engine based upon the first temperature, and selectively starts a reductant injection process based upon the second temperature.
Accurate modeling of photovoltaic (PV) performance requires the precise calculation of module temperature. Currently, most temperature models rely on steady-state assumptions that do not account for the transient climatic conditions and thermal mass of the module. On the other hand, complex physics-based transient models are computationally expensive and difficult to parameterize. In order to address this, a new approach to transient thermal modeling was developed, in which the steady-state predictions from previous timesteps are weighted and averaged to accurately predict the module temperature at finer time scales. This model is informed by 3-D finite-element analyses, which are used to calculate the effect of wind speed and module unit mass on module temperature. The model, in application, serves as an added filter over existing steady-state models that smooths out erroneous values that are a result of intermittency in solar resource. Validation of this moving-average model has shown that it can improve the overall PV energy performance model accuracy by as much as 0.58% over steady-state models based on mean absolute error improvements and can significantly reduce the variability between the model predictions and measured temperature times series data.
The tetragonal domain structure in SrTiO{sub 3} (STO) is known to modulate the normal-state carrier density in LaAlO{sub 3}/SrTiO{sub 3} (LAO/STO) heterostructures, among other electronic properties, but the effect of STO domains on the superconductivity in LAO/STO has not been fully explored. Using a scanning SQUID susceptometer microscope to map the superconducting response as a function of temperature in LAO/STO, we find that the superconducting transition temperature is spatially inhomogeneous and modulated in a pattern that is characteristic of structural domains in the STO.
Two-dimensional van der Waals (vdW) magnets are attracting significant attention, both as platforms for studying fundamental magnetic interactions and for the exciting possibility of utilizing them as building blocks in devices and heterostructures, which may lead to new physical phenomena and functionalities. Here, we provide a detailed study of the crystal structure and physical properties of the recently discovered vdW ferromagnet FePd 2 Te 2 . We find this compound has a relatively wide width of formation, and grow single crystals with compositions Fe x Pd y Te 2 where x ranges from 0.9 to 1.1 and y from 1.8 to 2.5, respectively. Temperature-dependent X-ray diffraction and transport measurements reveal that a first-order structural transition occurs in the range of T = 360–420 K, where the critical temperature, modulation wave vector, and corresponding room-temperature crystal structures all depend on chemical composition. Above the transition, the compounds with Pd fraction y > 2 adopt a disordered derivative of the tetragonal FeTe structure, with the Fe layer showing mixed Fe/Pd occupancy and the extra Pd atoms partially occupying interstitial sites. Below 370 K, the structure is incommensurately modulated, likely associated with the complex ordering of Pd/Fe atoms in the metal layers or the interstitial Pd in the vdW gaps. For y < 2, the composition Fe 1.1 Pd 1.8 Te 2 has monoclinic symmetry at room temperature that is consistent with the reported structure of FePd 2 Te 2 . This phase undergoes a structural transition at 420 K for which the high temperature structure is yet to be determined; however, based on the similarities with the y > 2 compounds, we speculate that its T > 420 K structure is also tetragonal. Importantly, the high temperature, symmetry-breaking structural transition observed here provides a likely explanation for the origin of the structural domains previously observed in FePd 2 Te 2 . All compounds investigated in the Fe x Pd y Te 2 series show metallic behavior, with magnetic characterization indicating that they are easy-plane, hard, ferromagnets with T C spanning 98–180 K. Both the critical temperature for the structural transition and the Curie temperature are moderately suppressed with increasing Pd fraction y and corresponding decreasing Fe fraction x, indicating that synthetic control over x and y paves way for the further exploration of these compounds.
Domestic hot water (DHW) is the second-largest energy end use in U.S. buildings; it is exceeded only by space conditioning. In this study, the U.S. Department of Energy's Building America research team Advanced Research Integrated Energy Solutions installed and tested two types of recirculation controls in a pair of buildings to evaluate their energy savings potential. Demand control, temperature modulation (TM) controls, and their simultaneous operation were compared to the baseline case of constant recirculation.
Explore the source record for details and available documents.
When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.
Urban air mobility (UAM) demands batteries with high energy density, long cycle life, and fast rechargeability. In this paper, we demonstrate an energy-dense lithium-ion battery (LiB) with ultralong cycle life under ultrafast charging. By using the asymmetric temperature modulation (ATM) method, i.e., charging at an elevated temperature and discharging around the ambient temperature, it is experimentally shown that the 209 Wh/kg LiB is charged to 88% state of charge (SOC) in ~5 min under UAM cycling while retaining 97.7% capacity after 1,000 cycles. Moreover, an experimentally validated electrochemical-thermal (ECT) model is developed to elucidate the fast charging process and the degradation mode of UAM batteries, quantitatively capturing lithium plating during fast charging. We find that the LiBs for UAM applications are most prone to lithium plating due to their higher initial SOC required as the reserve for safety; nevertheless, the ATM method is effective in minimizing or preventing lithium plating in the high SOC range of 30-90%. In addition to slowing down capacity fade, the ATM method also raises the usable capacity by 10%, which boosts the battery energy density and ensures the battery to perform full UAM cycles even at the end of life.
Photovoltaic (PV) module qualification standards, IEC 61215 and IEC 61730, were designed to apply to “general open-air climates” and IEC 61730 specifically indicated applicability of ambient air temperature of 40°C. Additionally, these standards provided allowances for so-called “open rack mounted PV modules” without a clear definition of “open-rack.” These implied restrictions and allowances meant that hotter climates or thermally restrictive installation methods may not be covered by these often customer-mandated certification standards. This is particularly salient for the significant growth regions of the Middle East and India that would be expected to operate at significantly higher temperatures. The applicability of these documents raised issues over the definition of “open rack” and the fact that the geographic location is just as important as the mounting configuration in assessing the impact of the micro-environment of a PV module. This work summarizes the scientific background for IEC Technical Specification 63126:2020 ED1, titled “Guidelines for qualifying PV modules components and materials for operation at high temperatures.” This standard was recently published by the IEC and is the first step in a systematic effort to rework these standards to address the question of temperature more directly. Instead of specifying a mounting condition, we specify different suites of tests suitable for a system (PV module, mounting style, and location) defined by the 98th percentile cell temperature. With a defined temperature regime to work from, this allowed us to use existing literature research combined with additional modeling work to determine, which tests would need to be modified. This resulted in suggested changes to material thermal indices, thermal cycling temperatures, hot spot testing, ultraviolet testing, and bypass diode testing among other tests and characteristics described in this study.
An experimental study on operation performance of photovoltaic-thermal solar heat pump air-conditioning system was conducted in this paper. The experimental system of photovoltaic-thermal solar heat pump air-conditioning system was set up. The performance parameters such as the evaporation pressure, the condensation pressure and the coefficient of performance (COP) of heat pump air-conditioning system, the water temperature and receiving heat capacity in water heater, the photovoltaic (PV) module temperature and the photovoltaic efficiency were investigated. The experimental results show that the mean photovoltaic efficiency of photovoltaic-thermal (PV/T) solar heat pump air-conditioning system reaches 10.4%, and can improve 23.8% in comparison with that of the conventional photovoltaic module, the mean COP of heat pump air-conditioning system may attain 2.88 and the water temperature in water heater can increase to 42 C. These results indicate that the photovoltaic-thermal solar heat pump air-conditioning system has better performances and can stably work. (author)
We report heat mitigation for large-scale solar photovoltaic (PV) arrays is crucial to extend lifetime and energy harvesting capacity. PV module temperature is dependent on site-specific farm geometry, yet common predictions consider panel-scale and environmental factors only. Here, we characterize convective cooling in diverse PV array designs, capturing combined effects of spatial and atmospheric variation on panel temperature and production. Parameters, including row spacing, panel inclination, module height, and wind velocity, are explored through wind tunnel experiments, high-resolution numerical simulations, and operating field data. A length scale based on fractal lacunarity encapsulates all aspects of arrangement (angle, height, etc.) in a single value. When applied to the Reynolds number Re within the canonical Nusselt number heat transfer correlation, lacunarity reveals a relationship between convection and farm-specific geometry. This correlation can be applied to existing and forthcoming array designs to optimize convective cooling, ultimately increasing production and PV cell life.
Combined‐accelerated stress testing (C‐AST) is developed to establish the durability of photovoltaic (PV) products, including for degradation modes that are not a priori known or examined in standardized tests. C‐AST aims to comprehensively represent the sample, stress factors, and their combinations using levels at the statistical tails of the natural environment. Acceleration factors for relevant climate sequences within the C‐AST cycle with respect to the Florida USA climate are estimated for selected degradation mechanisms. It is found that for degradation of the outer backsheet polymer layer, the acceleration factor of the tropical climate sequence (the longest of the climate sequences) is f ( T , G ) = 17.3 with ultraviolet photodegradation; for polyethylene terephthalate hydrolysis (backsheets), f ( T , RH ) = 426; for electrochemical corrosion (PV cell), f ( I ) = 14.1; and for PbSn solder fatigue f (Δ T , r ( T )) = 17.3. Here, T is the module temperature, G is the broadband spectrum irradiance on the plane of array of the module, RH is the relative humidity on the module surface, I is the leakage current through the module packaging, and r ( T ), the number of temperature reversals. The methods discussed herein are generally applicable for evaluating acceleration factors in other accelerated test methods.
The capacitive ferroelectric thermoelectric converter harvesting electrical energy through non-linear capacitance variation caused by changes in temperature is analyzed. The ferroelectric material used was the thin (0.5 μm) Ba{sub 0.3}Sr{sub 0.7}TiO{sub 3} film. On the basis of experimental dependencies of the ferroelectric film permittivity on temperature ranging from 100 K to 350 K under different electric fields up to 80 V/μm, the optimum values of operating temperatures and electric field for the energy harvesting optimization were determined. For the temperature oscillations of ±15 K around room temperature and electric field about 40 V/μm, the harvested energy was estimated as 30 mJ/cm{sup 3}. It is shown that the use of thin ferroelectric films for rapid capacitance variation versus temperature and microelectromechanical systems for fast temperature modulations may be a relevant solution for creation of small power scale generators for portable electronics.