Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Acceleration of Solvation Free Energy Calculation via Thermodynamic Integration Coupled with Gaussian Process Regression and Improved Gelman–Rubin Convergence Diagnostics

The determination of the solvation free energy of ions and molecules holds profound importance across a spectrum of applications spanning chemistry, biology, energy storage, and the environment. Molecular dynamics simulations are powerful tools for computing this critical parameter. Nevertheless, the accurate and efficient calculation of the solvation free energy becomes a formidable endeavor when dealing with complex systems characterized by potent Coulombic interactions and sluggish ion dynamics and, consequently, slow transition across various metastable states. Here, in the present study, we expose limitations stemming from the conventional calculation of the statistical inefficiency g in the thermodynamic integration method, a factor that can hinder the determination of convergence of the solvation free energy and its associated uncertainty. Instead, we propose a robust scheme based on Gelman–Rubin convergence diagnostics. We leverage this improved estimation of uncertainties to introduce an innovative accelerated thermodynamic integration method based on the Gaussian Process regression. This methodology is applied to the calculation of the solvation free energy of trivalent rare-earth elements immersed in ionic liquids, a scenario in which the aforementioned challenges render standard approaches ineffective. The proposed method proves to be effective in computing solvation free energy in situations where traditional thermodynamic integration methods fall short.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗

A centrifugal microfluidic cross-flow filtration platform to separate serum from whole blood for the detection of amphiphilic biomarkers

Abstract The separation of biomarkers from blood is straightforward in most molecular biology laboratories. However, separation in resource-limited settings, allowing for the successful removal of biomarkers for diagnostic applications, is not always possible. The situation is further complicated by the need to separate hydrophobic signatures such as lipids from blood. Herein, we present a microfluidic device capable of centrifugal separation of serum from blood at the point of need with a system that is compatible with biomarkers that are both hydrophilic and hydrophobic. The cross-flow filtration device separates serum from blood as efficiently as traditional methods and retains amphiphilic biomarkers in serum for detection.

59 BASIC BIOLOGICAL SCIENCES↗

Details of the neutral energy distribution and ionization source using spectrally resolved Balmer-alpha measurements on DIII-D

Spectrally resolved passive Balmer- α (D- α, H- α) measurements from the DIII-D 16 channel edge main-ion charge exchange recombination system confirm the presence of higher energy neutrals (“thermal” neutrals) in addition to the cold neutrals that recycle off the walls in the edge region of DIII-D plasmas. Charge exchange between thermal ions and edge neutrals transfers energy and momentum between the populations giving rise to thermal neutrals with energies approximating the ions in the pedestal region. Multiple charge exchange events in succession allow an electron to effectively take a random walk, transferring from ion to ion, providing a pathway of increasing energy and velocity, permitting a neutral to get deeper into the plasma before a final ionization event that contributes to the ion and electron particle fueling. Spectrally resolved measurements provide information about the density and velocity distribution of these neutrals, which has been historically valuable for validating Monte Carlo neutral models, which include the multi stage charge exchange dynamics. Here, in this study, a multi-channel set of such measurements is used to specifically isolate the details of the thermal neutrals that are responsible for fueling inside the pedestal top. Being able to separate the thermal from the cold emission overcomes several challenges associated with optical filter-based neutral density measurements. The neutral dynamics, deeper fueling by the thermal neutrals, and spectral measurement are modeled with the FIDASIM Monte Carlo collisional radiative code, which also produces synthetic spectra with a shape that is in close agreement with the measurements. By scaling the number of neutrals in the simulation to match the intensity of the thermal emission, we show it is possible to obtain local neutral densities and ionization source rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ground state rotational and kinetic temperatures of C 2 molecules in a laser-produced plasma

This study presents an experimental comparison between rotational and kinetic temperatures of molecular species in a laser-produced plasma, utilizing tunable laser absorption spectroscopy. We analyzed high-resolution and time-resolved absorption spectra of 31 rotational transitions within the Phillips A 1 II u –X 1 Σ g 3-0 band of the C 2 molecule, measured from a laser-produced graphite plasma in ~2 Torr argon, within the 771–781 nm spectral range. Spectral fitting provided quantitative state column densities of C 2 rotational energy levels in the ground electronic and vibrational states. Boltzmann analysis revealed thermalized rotational distributions showing rotational temperatures decreasing from 3000 to 600 K within 5–500 μs following the onset of the laser plasma. The measured kinetic and rotational temperatures of C 2 molecules are comparable, suggesting that collisional processes in the laser-produced plasma are sufficient to maintain thermal equilibrium between the C 2 molecules and the Ar background gas.

Absorption spectroscopy↗

A Step-by-Step Protocol from METASPACE to Biological Interpretation

Mass spectrometry imaging (MSI) represents an exceptional tool for exploring complex biological systems spatially at the molecular level. However, due to its multidimensional nature and large-scale data output, it presents considerable challenges when it comes to extracting meaningful biological insights. Recent advancements, such as the METASPACE platform, have enabled researchers to efficiently process, annotate, and interpret MSI datasets by leveraging machine learning and cloud-based infrastructure. In this tutorial, we present a detailed and user-friendly R-pipeline designed to help METASPACE users navigate untargeted metabolomic annotations and transform them into practical insights about their biological systems. By combining METASPACE annotations with rapid R-based screening, this workflow not only streamlined the analytical process but also enhanced the understanding of spatial molecular distribution, especially for complex systems. Here, this easy-to-follow approach has the potential for applications in diagnostics, drug discovery, environmental and ecological processes, and more. We envision this pipeline to be particularly useful for newcomers to the field of MSI and

Moreno Pedraza, Abigail↗

Human Monoclonal IgE Antibodies—a Major Milestone in Allergy

This review provides an overview of this major milestone in allergy, the first atomic resolution structure of an authentic human IgE epitope. The molecular insights that IgE epitopes provide will allow for structure-based design approaches to the development of novel diagnostics, antibody therapeutics, and immunotherapies.

59 BASIC BIOLOGICAL SCIENCES↗

Structural insights into the unique recognition module between α-synuclein peptide and nanobody

Nanobodies are single-domain fragments of antibodies with comparable specificity and affinity to antibodies. They are emerging as versatile tools in biology due to their relatively small size. Here, we report the crystal structure of a specific nanobody Nbα-syn01, bound to a 14 amino acid long peptide of α-synuclein (αSyn), a 140-residue protein whose aggregation is associated with Parkinson's disease. The complex structure exhibits a unique binding pattern where the αSyn peptide replaces the N-terminal region of nanobody. Recognition is mediated principally by extended main chain interaction of the αSyn peptide and specificity of the interaction lies in the central 48–52 region of αSyn peptide. Structure-guided truncation of Nbα-syn01 shows tighter binding to αSyn peptide and improved inhibition of α-synuclein aggregation. The structure of the truncated complex was subsequently determined and was indistinguishable to full length complex as the full-length form had no visible electron density for the N-terminal end. These findings reveal the molecular basis for a previously unobserved binding mode for nanobody recognition of α-synuclein, providing an explanation for the enhanced binding, and potential for an alternate framework for structure-based protein engineering of nanobodies to develop better diagnostic and therapeutic tools.

59 BASIC BIOLOGICAL SCIENCES↗

Tantalum oxide and nitride spectral features from a laser-produced plasma

Here, we report measurements of time-resolved Ta, TaO and TaN emission spectroscopic signatures from a laser-produced plasma. Plasmas were generated using 1064 nm, 6 ns pulses from an Nd:YAG laser focused onto a pure Ta metal target in a gaseous environment with varying percentages of O 2 /N 2 for controlling gas-phase oxidation/plasma chemistry. Time-resolved analysis showed that Ta oxide emission is prominent at later times in plasma evolution, whereas strong atomic emission is present at early times in air. Emission spectral features as a function of O 2 partial pressure showed that TaO emission intensity increases, while the peak intensity of TaO appears earlier with increasing O 2 availability. We also report emission spectra of TaN, and show that plasma chemistry favors TaO formation instead of TaN when O 2 is present in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DOE Plasma Science Center - Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems (Final Report DE-SC0001939)

Low temperature plasmas (LTPs) are the plasmas of electron-volt (eV) physics and eV technologies. LTPs have characteristic electron temperatures of a few eV and fractional ionizations that are typically small. Since LTPs have electron temperatures commensurate with the threshold energies of excited states in neutral atoms and molecules, power transfer from electrons to these atoms and molecules efficiently produces activated species (e.g., radicals, excited states, photons). Acceleration of ions in the sheaths of LTPs to energies of tens to hundreds of eV enable activation of surface modifying processes – sputtering, etching, deposition. With such properties, LTPs are often and beneficially used in technological devices, ranging from etching and deposition in microelectronics and solar cell fabrication, to hardening of surgical instruments. LTPs harbor fundamental science issues that are intellectually challenging and rewarding. At the same time, there are enormous societal benefits that are enabled by LTPs. The entire present-day and future information technology infrastructure owes its very existence to LTPs. Renewable energy sources, such as solar cell arrays, could not be economically produced in the absence of deposition and etching by LTPs. In acknowledgment of the importance of LTPs, the DOE Office of Fusion Energy Sciences supported the Plasma Science Center for Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems from August 2009 to July 2021, consisting of an initial 5-year grant, 3 funded extensions and 2 no-cost extensions. This is the final report of the Center in which the productivity of the Center is discussed in terms of publications, impact and personnel. High-lights of the research performed in the Center are provided.

36 MATERIALS SCIENCE↗

Optical Biosensor Platforms Display Varying Sensitivity for the Direct Detection of Influenza RNA

Detection methods that do not require nucleic acid amplification are advantageous for viral diagnostics due to their rapid results. These platforms could provide information for both accurate diagnoses and pandemic surveillance. Influenza virus is prone to pandemic-inducing genetic mutations, so there is a need to apply these detection platforms to influenza diagnostics. Here, we analyzed the Fast Evaluation of Viral Emerging Risks (FEVER) pipeline on ultrasensitive detection platforms, including a waveguide-based optical biosensor and a flow cytometry bead-based assay. The pipeline was also evaluated in silico for sequence coverage in comparison to the U.S. Centers for Disease Control and Prevention’s (CDC) influenza A and B diagnostic assays. The influenza FEVER probe design had a higher tolerance for mismatched bases than the CDC’s probes, and the FEVER probes altogether had a higher detection rate for influenza isolate sequences from GenBank. When formatted for use as molecular beacons, the FEVER probes detected influenza RNA as low as 50 nM on the waveguide-based optical biosensor and 1 nM on the flow cytometer. In addition to molecular beacons, which have an inherently high background signal we also developed an exonuclease selection method that could detect 500 pM of RNA. The combination of high-coverage probes developed using the FEVER pipeline coupled with ultrasensitive optical biosensors is a promising approach for future influenza diagnostic and biosurveillance applications.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Full radiator-perturber interaction in computer simulations of hydrogenic spectral line broadening by plasmas

Spectral line broadening by plasmas can be computed by solving the equation of motion for the dipole of the radiating system perturbed by a fluctuating potential obtained from computer simulations. Such calculations have relied on the multipole expansion of the radiator-plasma interaction often keeping only the dipole term. With increasing density, however, higher multipoles as well as plasma perturbers overlapping the bound electron wave functions are expected to become important. For hydrogenic systems, the atomic matrix elements of the full Coulomb and screened Coulomb interactions are given by analytical formulas. Using these results, a computer simulation approach that accounts for the full radiator-plasma interaction is developed. One benefit is the removal of inherent strong collision divergences in the multipole expansion approximation. Furthermore, it yields the plasma polarization shift produced by perturbers penetrating the wave function of the radiator bound electrons. Here, the model was applied to hydrogenic argon Ly-α , Ly- β , and Ly-$\gamma$ spectral lines in a dense argon plasma at free electron densities of 10 24 or 10 25 cm ⁻3 and temperature of $800$ $eV$ relevant to plasma diagnostic techniques for inertial confinement fusion implosions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theoretical level energies, radiative lifetimes and transitions in W IX

The atomic states of the W IX (W{sup 8+}) tungsten ion lying below the W{sup 9+} ionisation threshold have been studied theoretically, employing the multiconfiguration Dirac–Hartree–Fock method with configuration interaction. The level electronic structures and their energies are presented. The electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) radiative transitions have been computed in order to calculate the radiative lifetimes of given states. Transition wavelengths, energies, and decay rates are also presented for selected high-intensity E1 transitions. The configuration interaction method was applied to estimate electron correlation effects. The aim of the present research was to fill a lack of atomic data for low-charged tungsten ions, which may be useful in low-temperature plasma diagnostics and may form the base for collisional–radiative modelling of spectra for low-charged tungsten ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular Origins of Near-Infrared Luminescence in Molybdenum and Tungsten Oxyhalide Perovskites

Materials with near-infrared (near-IR) luminescence are desirable for applications in communications and sensing, as well as biomedical diagnostics and imaging. The most used inorganic near-IR emitters rely on precise doping of host crystal structures with select rare-earth or transition metal ions. Recently, another class of materials with intrinsic near-IR emission has been reported. The compositions of these materials were initially described as vacancy-ordered halide double perovskites Cs 2 MoCl 6 and Cs 2 WCl 6 , but further investigation by some of us on the compound reported as Cs2WCl6 revealed an oxyhalide instead, with a composition Cs 2 WO x Cl 6–x , where 1 < x < 2. Here we demonstrate that the Mo compounds similarly possess the composition Cs 2 MoO x Cl 6–x or Cs 2 MoO x Br 6–x where 1 < x < 2. Preparing the pure halide appears harder for Mo than for W, and we have not succeeded in doing so. The distinctly different composition requires the coordination environment and oxidation state for the Mo and W centers to be reconsidered from what was assumed for the pure halides. In this work, we examine the mechanism for near-IR emission in these materials given their true structures and compositions. We demonstrate that the luminescence is due to the specific d-orbital splitting caused by the presence of oxygen in the distorted [MOX 5 ] 2– octahedra (X is Cl or Br). The fine structure in the emission spectra at low temperatures has been resolved and is attributed to vibronic coupling to the Mo–O and W–O bond stretches. Understanding the true structure and composition of these interesting materials, besides explaining the near-IR luminescence, suggests how this desirable emission can be realized and manipulated.

36 MATERIALS SCIENCE↗

MicroRNAs as diagnostic and prognostic biomarkers of age-related macular degeneration: advances and limitations

A main cause of vision loss in the elderly is age-related macular degeneration (AMD). Among the cellular, biochemical, and molecular changes linked to this disease, inflammation and angiogenesis appear as being crucial in AMD pathogenesis and progression. There are two forms of the disease: dry AMD, accounting for 80–90% of cases, and wet AMD. The disease usually begins as dry AMD associated with retinal pigment epithelium and photoreceptor degeneration, whereas wet AMD is associated with choroidal neovascularization resulting in severe vision impairment. The new vessels are largely malformed, leading to blood and fluid leakage within the disrupted tissue, which provokes inflammation and scar formation and results in retinal damage and detachment. MicroRNAs are dysregulated in AMD and may facilitate the early detection of the disease and monitoring disease progression. Two recent reviews of microRNAs in AMD had indicated weaknesses or limitations in four earlier investigations. Studies in the last three years have shown considerable progress in overcoming some of these concerns and identifying specific microRNAs as biomarkers for AMD. Further large-scale studies are warranted using appropriate statistical methods to take into account gender and age disparity in the study populations and confounding factors such as smoking status.

60 APPLIED LIFE SCIENCES↗