Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improved Discrete Approximation of Laplacian of Gaussian

An improved method of computing a discrete approximation of the Laplacian of a Gaussian convolution of an image has been devised. The primary advantage of the method is that without substantially degrading the accuracy of the end result, it reduces the amount of information that must be processed and thus reduces the amount of circuitry needed to perform the Laplacian-of- Gaussian (LOG) operation. Some background information is necessary to place the method in context. The method is intended for application to the LOG part of a process of real-time digital filtering of digitized video data that represent brightnesses in pixels in a square array. The particular filtering process of interest is one that converts pixel brightnesses to binary form, thereby reducing the amount of information that must be performed in subsequent correlation processing (e.g., correlations between images in a stereoscopic pair for determining distances or correlations between successive frames of the same image for detecting motions). The Laplacian is often included in the filtering process because it emphasizes edges and textures, while the Gaussian is often included because it smooths out noise that might not be consistent between left and right images or between successive frames of the same image.

Shuler, Robert L., Jr.↗

Estimation of an Optimal Stimulus Amplitude for Using Vestibular Stochastic Stimulation to Improve Balance Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). The goal of this project was to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection.

Goel, R.↗

Gumstix ISS Camera

With many jobs that are considered to be too meticulous for the astronauts on the International Space Station, our commercial camera aims to eliminate some of those tasks. Debris and other metal are often found falling away from the station, and this could signal a repair to be made. These cameras, programmed with OpenCV motion detection software, would be able to recognize such debris and relay a live feed to operators either on the station or back on Earth.

Pacheco, Natali↗

Moment tensor reconstruction

A seismic monitoring system includes a plurality of seismic monitors and a processing device operatively coupled to the plurality of seismic monitors. The processing device receives recordings of waveforms of motion detected at the plurality of seismic detectors in a geographic area. The processing device applies the respective recordings to corresponding positions of the seismic detectors in a three-dimensional geological model that describes its elastic attributes and tests a plurality of moment tensors at a plurality of locations. Based on the testing, the processing device determines a globally convergent source location and moment tensor in the three-dimensional model based on the testing.

Petrov, Petr↗

First Detection of Orbital Motion for HD 106906 b: A Wide-separation Exoplanet on a Planet Nine–like Orbit

HD 106906 is a 15 Myr old short-period (49 days) spectroscopic binary that hosts a wide-separation (737 au) planetary-mass (∼11 M{sub Jup}) common proper motion companion, HD 106906 b. Additionally, a circumbinary debris disk is resolved at optical and near-infrared wavelengths that exhibits a significant asymmetry at wide separations that may be driven by gravitational perturbations from the planet. In this study we present the first detection of orbital motion of HD 106906 b using Hubble Space Telescope images spanning a 14 yr period. We achieve high astrometric precision by cross-registering the locations of background stars with the Gaia astrometric catalog, providing the subpixel location of HD 106906 that is either saturated or obscured by coronagraphic optical elements. We measure a statistically significant 31.8 ± 7.0 mas eastward motion of the planet between the two most constraining measurements taken in 2004 and 2017. This motion enables a measurement of the inclination between the orbit of the planet and the inner debris disk of either 36{sub −14}{sup +27} deg or 44{sub −14}{sup +27} deg, depending on the true orientation of the orbit of the planet. There is a strong negative correlation between periastron and mutual inclination; orbits with smaller periastra are more misaligned with the disk plane. With a periastron of 510{sub −320}{sup +480} au, HD 106906 b is likely detached from the planetary region within 100 au radius, showing that a Planet Nine–like architecture can be established very early in the evolution of a planetary system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Galaxy Cluster Motions with the Kinematic Sunyaev-Zel'dovich Effect

Using high-resolution microwave sky maps made by the Atacama Cosmology Telescope, we for the first time detect motions of galaxy clusters and groups via microwave background .temperature distortions due to the kinematic Sunyaev.Zel'dovich effect. Galaxy clusters are identified by their constituent luminous galaxies observed by the Baryon Oscillation Spectroscopic Survey, part of the Sloan Digital Sky Survey III. The mean pairwise momentum of clusters is measured. at a statistical. significance of 3.8 sigma, and the signal is consistent with the growth of cosmic structure in the standard model of cosmology

Hand, Nick↗

Contact detection and contact motion for error recovery in the presence of uncertainties

Due to various kinds of uncertainties, a robot motion may fail and result in some unintended contact between the object held by the robot and the environment, which greatly hampers robotics applications on tasks with high-precision requirements, such as assembly tasks. Aiming at automatically recovering a robotic task from such a failure, this paper discusses, in the presence of uncertainties, contact detection based on contact motion for recovery. It presents a framework for on-line recognizing contacts using multiple sensor modalities in the presence of sensing uncertainties and means for ensuring successful compliant motions in the presence of sensing and control uncertainties.

Xiao, Jing↗

Model-based fault detection and isolation for intermittently active faults with application to motion-based thruster fault detection and isolation for spacecraft

The present invention is a method for detecting and isolating fault modes in a system having a model describing its behavior and regularly sampled measurements. The models are used to calculate past and present deviations from measurements that would result with no faults present, as well as with one or more potential fault modes present. Algorithms that calculate and store these deviations, along with memory of when said faults, if present, would have an effect on the said actual measurements, are used to detect when a fault is present. Related algorithms are used to exonerate false fault modes and finally to isolate the true fault mode. This invention is presented with application to detection and isolation of thruster faults for a thruster-controlled spacecraft. As a supporting aspect of the invention, a novel, effective, and efficient filtering method for estimating the derivative of a noisy signal is presented.

Wilson, Edward↗

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A model describing vestibular detection of body sway motion.

An experimental technique was developed which facilitated the formulation of a quantitative model describing vestibular detection of body sway motion in a postural response mode. All cues, except vestibular ones, which gave a subject an indication that he was beginning to sway, were eliminated using a specially designed two-degree-of-freedom platform; body sway was then induced and resulting compensatory responses at the ankle joints measured. Hybrid simulation compared the experimental results with models of the semicircular canals and utricular otolith receptors. Dynamic characteristics of the resulting canal model compared closely with characteristics of models which describe eye movement and subjective responses to body rotational motions. The average threshold level, in the postural response mode, however, was considerably lower. Analysis indicated that the otoliths probably play no role in the initial detection of body sway motion.

Nashner, L. M.↗

Visual acceleration detection - Effect of sign and motion orientation

Thresholds for the detection of constant acceleration and deceleration of a discrete object moving along horizontal and vertical axes were studied. A staircase methodology was used to determine thresholds for three average velocities (0.7, 1.2, and 1.7 deg/sec). Thresholds, expressed as the proportion of velocity change, did not differ significantly among the average velocities; thus, a consistent Weber-like fraction is suggested by the data. Furthermore, there was an interaction between the axis of motion (horizontal or vertical) and the sign of the velocity change (acceleration or deceleration): accelerations were easier to detect along the vertical axis, decelerations along the horizontal axis.

Calderone, Jack B.↗

Motion Estimation Utilizing Range Detection-Enhanced Visual Odometry

A motion determination system is disclosed. The system may receive a first and a second camera image from a camera, the first camera image received earlier than the second camera image. The system may identify corresponding features in the first and second camera images. The system may receive range data comprising at least one of a first and a second range data from a range detection unit, corresponding to the first and second camera images, respectively. The system may determine first positions and the second positions of the corresponding features using the first camera image and the second camera image. The first positions or the second positions may be determined by also using the range data. The system may determine a change in position of the machine based on differences between the first and second positions, and a VO-based velocity of the machine based on the determined change in position.

Friend, Paul Russell↗

Method and apparatus for telemetry adaptive bandwidth compression

Methods and apparatus are provided for automatic and/or manual adaptive bandwidth compression of telemetry. An adaptive sampler samples a video signal from a scanning sensor and generates a sequence of sampled fields. Each field and range rate information from the sensor are hence sequentially transmitted to and stored in a multiple and adaptive field storage means. The field storage means then, in response to an automatic or manual control signal, transfers the stored sampled field signals to a video monitor in a form for sequential or simultaneous display of a desired number of stored signal fields. The sampling ratio of the adaptive sample, the relative proportion of available communication bandwidth allocated respectively to transmitted data and video information, and the number of fields simultaneously displayed are manually or automatically selectively adjustable in functional relationship to each other and detected range rate. In one embodiment, when relatively little or no scene motion is detected, the control signal maximizes sampling ratio and causes simultaneous display of all stored fields, thus maximizing resolution and bandwidth available for data transmission. When increased scene motion is detected, the control signal is adjusted accordingly to cause display of fewer fields. If greater resolution is desired, the control signal is adjusted to increase the sampling ratio.

Graham, Olin L.↗

CalWave - TEAMER UMaine 2021 Tank Testing

This is the data submission to the teamer report for RFTS1 during which tank testing at UMaine W2 tank occurred. This submission includes the relevant information and recorded data of CalWave's UMaine wave tank testing conducted under TEAMER Request for Support Round 1. During the testing CalWave assessed an autonomous control approach for changing PTO gain parameters based on "on board" sea state detection. The data submitted includes an overview of normalized PTO gains based on sea state values and for a set of 8 relevant sea states the WEC motion. All data was collected on CalWave's SCADA system and UMaine's motion tracking system. The data submitted suffices the creation of figures as shown in the PDF report submitted alongside the data and the submission includes excel sheets (parameter gains), MATLAB structures (absorber motion), and the mentioned PDF report.

16 TIDAL AND WAVE POWER↗