At least 73 records · Page 4

Near field testing of LARC multiple beam antenna

Near field antenna measurements as an alternative to far field measurements are discussed. Most of the serious shortcomings of far field measurements can be alleviated using near field techniques. The near field data can be used as a direct diagnostic of antenna performance before the integration by the aperture which can make it difficult to isolate the cause of far field pattern anomalies.

Lang, G. J.↗

Economic comparison of FDMA and TDMA options for communications by Ka-band multiple beam satellites

An assessment is made of the feasibility of providing low data rate service to small earth stations by satellite at Ka-band. Technological as well as economic factors are considered. The results of NASA-sponsored contractual studies are compared and results of internal NASA studies are presented. Several FDMA and TDMA scenarios are critically examined with the objective of establishing the relative utility of such systems to end users. It is shown that FDMA has no advantage over TDMA in a multibeam scenario for 56 Kbs of data by voice, video, or the equivalent. For the same assumptions, significant weight and power advantages are realized in the space segment using TDMA.

Stevens, G. H.↗

Advanced 30/20 GHz multiple beam antenna for future communications satellites

The technologies which will be implemented in advanced satellite communications systems being studied by NASA and the intended coverage scenarios are described. The systems will function at 30/20 GHz with 2.5 GHz bandwidth for the uplink and downlink. Subfrequencies will have 500 MHz bandwidth and operations will include TDMA modes. Sample scan patterns are presented for the centerminous U.S. The signals will be broadcast from a multibeam offset Cassegrain reflector antenna to obtain a low sidelobe, wide angle scan. Three contiguous low sidelobe beams will be generated with a diplex feed cluster and a 19 element scanning beam-forming network. The same technology will be used to double the capacity of current 14/12 GHz satellites.

Chen, C. C.↗

Near field to far field transformations and multiple beam forming and steering

The feasibility of acoustic verification of microwave near field to far field transformation algorithms using the Phased Array Sonic Simulation System was studied. Existing electromagnetic near field measurement techniques and transformation algorithms (equations) were investigated. It was analytically determined that acoustic verification is valid. Acoustic simulation of electromagnetic near field to far field transformations is emphasized. The acoustic simulation of electromagnetic near field to far field transformation is verified for the modal expansion method. In the modal expansion method, data from antenna near field measurements are converted to a summation or spectrum of modes corresponding to wave numbers in the measurement coordinate system. Fourier transformation of those measurements preserves the far field information in a spectral form that is then readily extractable.

Source record↗

An airborne multiple-beam 1.4 GHz pushbroom microwave radiometer

A method is described for providing soil moisture measurements from satellites by performing simultaneous measurements across track (the pushbroom approach). The method has the advantage of obtaining the required swath width without sacrificing sensitivity. A prototype Pushbroom Microwave Radiometer developed at NASA's Langley Research Center is described. It is a multibeam L-Band (1413 MHz) radiometer system providing simultaneous cross track measurements. Results of flight tests onboard a P-3 aircraft are discussed.

Harrington, R. F.↗

Switched steerable multiple beam antenna system

A steerable multibeam five element cross-feed cluster antenna system is described. The feed power is divided into five branches. Each branch includes a switching network comprised of a plurality of time delay elements each individually controlled by a respective electromagnetic latching switch. Frequency independent individual two-dimensional beam steering at intermediate (IF) scanning frequencies is thereby provided wherein discrete incremental time delays are introduced by the switching networks into each branch and the signals recombined thereafter to form each beam. The electromagnetic latched switching reduces power consumption and permits higher power switching and reciprocal coincident tranmsit and receive operation. Frequency independence due to incremental time delay switching permits coincident reciprocal operation and steering for transmit-receive signal paths carrying different transmit-receive frequencies. Diagonal quarter wave plates in the waveguides alter polarization from the circular to orthogonal linear to provide transmitter-receiver isolation.

Richard S Iwasaki↗

Electron gun for a multiple beam klystron with magnetic compression of the electron beams

A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.

47 OTHER INSTRUMENTATION↗

Multiple Beams

Explore the source record for details and available documents.

Mozley, R.↗

Fully 3D Multiple Beam Dynamics Processes Simulation for the Fermilab Tevatron

The Fermilab Tevatron has been, until 2010, the premier high-energy physics collider in the world. The data collected over the last decade by high-energy physics experiments running at the Tevatron have been analyzed to make important measurements in fundamental areas such as B meson masses and flavor oscillation, searches for the Higgs boson, and supersymmetry. Collecting these data at the limits of detectability has required the Tevatron to operate reliably at high beam intensities to maximize the number of collisions to analyze. This impressive achievement has been assisted by the use of HPC resources and software provided through the SciDAC program. This paper describes the enhancements to the BeamBeam3d code to realistically simulate the Tevatron, the validation of these simulations, and the improvement in equipment reliability and personal safety achieved with the aid of simulations.

43 PARTICLE ACCELERATORS↗

External-Beam Accelerated Partial Breast Irradiation Using Multiple Proton Beam Configurations

Purpose: To explore multiple proton beam configurations for optimizing dosimetry and minimizing uncertainties for accelerated partial breast irradiation (APBI) and to compare the dosimetry of proton with that of photon radiotherapy for treatment of the same clinical volumes. Methods and Materials: Proton treatment plans were created for 11 sequential patients treated with three-dimensional radiotherapy (3DCRT) photon APBI using passive scattering proton beams (PSPB) and were compared with clinically treated 3DCRT photon plans. Monte Carlo calculations were used to verify the accuracy of the proton dose calculation from the treatment planning system. The impact of range, motion, and setup uncertainty was evaluated with tangential vs. en face beams. Results: Compared with 3DCRT photons, the absolute reduction of the mean of V100 (the volume receiving 100% of prescription dose), V90, V75, V50, and V20 for normal breast using protons are 3.4%, 8.6%, 11.8%, 17.9%, and 23.6%, respectively. For breast skin, with the similar V90 as 3DCRT photons, the proton plan significantly reduced V75, V50, V30, and V10. The proton plan also significantly reduced the dose to the lung and heart. Dose distributions from Monte Carlo simulations demonstrated minimal deviation from the treatment planning system. The tangential beam configuration showed significantly less dose fluctuation in the chest wall region but was more vulnerable to respiratory motion than that for the en face beams. Worst-case analysis demonstrated the robustness of designed proton beams with range and patient setup uncertainties. Conclusions: APBI using multiple proton beams spares significantly more normal tissue, including nontarget breast and breast skin, than 3DCRT using photons. It is robust, considering the range and patient setup uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory

Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.

43 PARTICLE ACCELERATORS↗

Feed System Design Considerations for Large Space Antenna Systems. Part 1: Multiple Apertures with Non-overlapping Feeds

A feed system design for large space antenna systems was considered. A multiple aperture system with nonoverlapping feeds is examined. Circular and quadrant aperture reflector radiation patterns are compared and the effect of adjacent aperture on radiation patterns of multiple aperture reflector antennas is illustrated. The following systems are examined: (1) feed design optimization for a multiple aperture reflector antenna; (2) radiation pattern for two quadrant reflector with optimized feed design; (3) multiple beam concept utliizing apertures and nonoverlapping feeds; (4) beam contours for two quadrant of multiple beam multiple aperture concept; (5) superposition of beams from two quadrants of multiple beam multiple aperture concent; (6)compensation for mislalignment of interleaved beams from two quadrants; and (7) beam quality improvement due to reorienting feed for offset reflector.

Bailey, M. C.↗