Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Precise Colloidal Plasmonic Photocatalysts Constructed by Multistep Photodepositions

Natural photosynthesis relies on a sophisticated charge transfer pathway among multiple components with precise spatial, energetic, and temporal organizations in the aqueous environment. It continues to inspire and challenge the design and fabrication of artificial multicomponent colloidal nanostructures for solar-to-fuel conversion. Herein, we introduce a plasmonic photocatalyst synthesized with colloidal methods with five integrated components including cocatalysts installed in orthogonal locations. The precise deposition of individual inorganic components on an Au/TiO 2 nanodumbell nanostructure is enabled by photoreduction and photo-oxidation, which selectively occurs at the TiO 2 tip sites and Au lateral sites, respectively. Under visible-light irradiation, the photocatalyst exhibited activity of oxygen evolution from water without scavengers. Here, we demonstrate that each component is essential for improving the photocatalytic performance. In addition, mechanistic studies suggest that the photocatalytic reaction requires combining the hot charge carriers derived from exciting both the d-sp interband transition and the localized surface plasmon resonance of Au.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers

Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever’s spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. With this data set, users can trivially calibrate cantilevers of the same type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QCD Theory Meets Information Theory

We present a novel technique to incorporate precision calculations from quantum chromodynamics into fully differential particle-level Monte Carlo simulations. By minimizing an information-theoretic quantity subject to constraints, our reweighted Monte Carlo incorporates systematic uncertainties absent in individual Monte Carlo predictions, achieving consistency with the theory input in precision and its estimated systematic uncertainties. Our method can be applied to arbitrary observables known from precision calculations, including multiple observables simultaneously. It generates strictly positive weights, thus offering a clear path to statistically powerful and theoretically precise computations for current and future collider experiments. As a proof of concept, we apply our technique to event-shape observables at electron-positron colliders, leveraging existing precision calculations of thrust. Our analysis highlights the importance of logarithmic moments of event shapes, which have not been previously studied in the collider physics literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated Precision Landing Performance and Technology Assessments of a Human- Scale Mars Lander Using a Generalized Simulation Framework

Human-scale missions to Mars will likely require multiple landers delivered precisely to designated locations. The current NASA human Mars reference architecture assumes delivery of three 25 t payloads from a 1- or 5-Sol orbit to the surface with a landing precision of 50 m to ensure logistics are located near the habitat. While initial navigation estimates improve with on-orbit ground tracking, errors increase during post-deorbit coast. Likewise, Mars atmospheric variability and forecasting uncertainty means that the entry vehicle guidance, navigation, and control systems must be robust to accommodate landing during any time of day or Mars year, including during dust storms. Precision landing technologies are currently being assessed to determine if onboard navigation sensors are sufficient to enable the landing accuracy required or if additional navigation aids such as surface or orbiting beacons will be needed. This study evaluates the system performance requirements to meet the desired landing accuracy for the reference vehicle design and entry, descent, and landing concept of operations. A detailed six degree-of-freedom integrated performance simulation framework is used to perform the assessment and demonstrate that under current assumptions, onboard navigation sensors are sufficient to support precision landing.

Chen, Po-Ting↗

Integrated Precision Landing Performance and Technology Assessments of a Human-Scale Mars Lander Using a Generalized Simulation Framework

Human-scale missions to Mars will likely require multiple landers delivered precisely to designated locations. The current NASA human Mars reference architecture assumes delivery of three 25 t payloads from a 1- or 5-Sol orbit to the surface with a landing precision of 50 m to ensure logistics are located near the habitat. While initial navigation estimates improve with on-orbit ground tracking, errors increase during post-deorbit coast. Likewise, Mars atmospheric variability and forecasting uncertainty means that the entry vehicle guidance, navigation, and control systems must be robust to accommodate landing during any time of day or Mars year, including during dust storms. Precision landing technologies are currently being assessed to determine if onboard navigation sensors are sufficient to enable the landing accuracy required or if additional navigation aids such as surface or orbiting beacons will be needed. This study evaluates the system performance requirements to meet the desired landing accuracy for the reference vehicle design and entry, descent, and landing concept of operations. A detailed six degree-of-freedom integrated performance simulation framework is used to perform the assessment and demonstrate that under current assumptions, onboard navigation sensors are sufficient to support precision landing.

spacecraft navigation↗

Precise Orbit Determination for LEO Spacecraft Using GNSS Tracking Data from Multiple Antennas

To support various applications, certain Earth-orbiting spacecrafts (e.g., SRTM, COSMIC) use multiple GNSS antennas to provide tracking data for precise orbit determination (POD). POD using GNSS tracking data from multiple antennas poses some special technical issues compared to the typical single-antenna approach. In this paper, we investigate some of these issues using both real and simulated data. Recommendations are provided for POD with multiple GNSS antennas and for antenna configuration design. The observability of satellite position with multiple antennas data is compared against single antenna case. The impact of differential clock (line biases) and line-of-sight (up, along-track, and cross-track) on kinematic and reduced-dynamic POD is evaluated. The accuracy of monitoring the stability of the spacecraft structure by simultaneously performing POD of the spacecraft and relative positioning of the multiple antennas is also investigated.

Kuang, Da↗

Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for {<=}1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multiple ion counter total evaporation (MICTE) method for precise analysis of plutonium by thermal ionization mass spectrometry

This study presents a total evaporation method for the analysis of sub-picogram quantities of Pu, utilizing an array of multiple ion counters. Data from three standards are presented to assess the utility of the technique. An external precision of 1.5% RSD (2σ) was achieved on aliquots approaching 100 fg for the minor 240 Pu isotope. Accurate analysis of <1 femtogram of 240 Pu, is achievable, with an external reproducibility of better than 10% RSD (2σ). Finally, this new technique represents a significant advance in the total evaporation method and will allow routine measurement of femtogram sized Pu samples by thermal ionization mass spectrometry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Photogrammetry of a 5m Inflatable Space Antenna With Consumer Digital Cameras

This paper discusses photogrammetric measurements of a 5m-diameter inflatable space antenna using four Kodak DC290 (2.1 megapixel) digital cameras. The study had two objectives: 1) Determine the photogrammetric measurement precision obtained using multiple consumer-grade digital cameras and 2) Gain experience with new commercial photogrammetry software packages, specifically PhotoModeler Pro from Eos Systems, Inc. The paper covers the eight steps required using this hardware/software combination. The baseline data set contained four images of the structure taken from various viewing directions. Each image came from a separate camera. This approach simulated the situation of using multiple time-synchronized cameras, which will be required in future tests of vibrating or deploying ultra-lightweight space structures. With four images, the average measurement precision for more than 500 points on the antenna surface was less than 0.020 inches in-plane and approximately 0.050 inches out-of-plane.

Pappa, Richard S.↗

Autonomous Magnetic Microrobots by Navigating Gates for Multiple Biomolecules Delivery

The precise delivery of biofunctionalized matters is of great interest from the fundamental and applied viewpoints. In spite of significant progress achieved during the last decade, a parallel and automated isolation and manipulation of rare analyte, and their simultaneous on-chip separation and trapping, still remain challenging. In this work, a universal micromagnet junction for self-navigating gates of microrobotic particles to deliver the biomolecules to specific sites using a remote magnetic field is described. In the proposed concept, the nonmagnetic gap between the lithographically defined donor and acceptor micromagnets creates a crucial energy barrier to restrict particle gating. It is shown that by carefully designing the geometry of the junctions, it becomes possible to deliver multiple protein-functionalized carriers in high resolution, as well as MCF-7 and THP-1 cells from the mixture, with high fidelity and trap them in individual apartments. Integration of such junctions with magnetophoretic circuitry elements could lead to novel platforms without retrieving for the synchronous digital manipulation of particles/biomolecules in microfluidic multiplex arrays for next-generation biochips.

36 MATERIALS SCIENCE↗

Precision bone and muscle loss measurements by advanced, multiple projection DEXA (AMPDXA) techniques for spaceflight applications

An advanced, multiple projection, dual energy x-ray absorptiometry (AMPDXA) scanner system is under development. The AMPDXA is designed to make precision bone and muscle loss measurements necessary to determine the deleterious effects of microgravity on astronauts as well as develop countermeasures to stem their bone and muscle loss. To date, a full size test system has been developed to verify principles and the results of computer simulations. Results indicate that accurate predictions of bone mechanical properties can be determined from as few as three projections, while more projections are needed for a complete, three-dimensional reconstruction. c 2001. Elsevier Science Ltd. All rights reserved.

NASA Discipline Life Sciences Technologies↗

Systematics of pre- and near-scission {alpha}-particle multiplicities in heavy-ion-induced fusion-fission reactions

The {alpha}-particle energy spectra have been measured in coincidence with fission fragments over a wide range of relative angles with respect to fragment emission direction in the {sup 11}B (62 MeV) + {sup 232}Th reaction. The {alpha}-particle multiplicity spectra have been fitted with moving source model to extract the precision ({alpha}{sub pre}) and near-scission ({alpha}{sub nse}) components. The present results, along with available data from the literature over a wide range of Z{sup 2}/A and the excitation energy of a compound system, have been analyzed to develop certain global features of the pre- and near-scission emission characteristics. It is seen that {alpha}{sub pre} values when normalized to E{sub CN}{sup 2.3} (E{sub CN} is the compound nucleus excitation energy) show a systematic linearly increasing trend with the {alpha}-particle emission Q value (Q{sub {alpha}}). The fraction of near-scission multiplicity is observed to be nearly the same at around 10% of the total precision multiplicity for all the systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shot-noise-limited control-loop noise in an interferometer with multiple degrees of freedom

Precise measurements, such as those made with interferometric gravitational-wave detectors, require the measurement device to be properly controlled so that the sensitivity can be as high as possible. Mirrors in the interferometer are to be located at specific operation points to isolate laser noise and to accumulate the signal in resonant cavities. On the other hand, rigid control of an auxiliary degree of freedom may result in imposing sensing noise of the control on the target object as excess force noise. Evaluation of this so-called loop noise is important in order to design a decent control scheme of the measurement device. In this paper, we show the method to calculate the level of loop noise, which has been recently implemented in simulation tools that are broadly used for designing gravitational-wave detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 3% SOLUTION: DETERMINATION OF THE HUBBLE CONSTANT WITH THE HUBBLE SPACE TELESCOPE AND WIDE FIELD CAMERA 3

We use the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST) to determine the Hubble constant from optical and infrared observations of over 600 Cepheid variables in the host galaxies of eight recent Type Ia supernovae (SNe Ia), providing the calibration for a magnitude-redshift relation based on 253 SNe Ia. Increased precision over past measurements of the Hubble constant comes from five improvements: (1) more than doubling the number of infrared observations of Cepheids in the nearby SN hosts; (2) increasing the sample size of ideal SN Ia calibrators from six to eight; (3) increasing by 20% the number of Cepheids with infrared observations in the megamaser host NGC 4258; (4) reducing the difference in the mean metallicity of the Cepheid comparison samples between NGC 4258 and the SN hosts from {Delta}log [O/H] = 0.08 to 0.05; and (5) calibrating all optical Cepheid colors with a single camera, WFC3, to remove cross-instrument zero-point errors. The result is a reduction in the uncertainty in H{sub 0} due to steps beyond the first rung of the distance ladder from 3.5% to 2.3%. The measurement of H{sub 0} via the geometric distance to NGC 4258 is 74.8 {+-} 3.1 km s{sup -1} Mpc{sup -1}, a 4.1% measurement including systematic uncertainties. Better precision independent of the distance to NGC 4258 comes from the use of two alternative Cepheid absolute calibrations: (1) 13 Milky Way Cepheids with trigonometric parallaxes measured with HST/fine guidance sensor and Hipparcos and (2) 92 Cepheids in the Large Magellanic Cloud for which multiple accurate and precise eclipsing binary distances are available, yielding 74.4 {+-} 2.5 km s{sup -1} Mpc{sup -1}, a 3.4% uncertainty including systematics. Our best estimate uses all three calibrations but a larger uncertainty afforded from any two: H{sub 0} = 73.8 {+-} 2.4 km s{sup -1} Mpc{sup -1} including systematic errors, corresponding to a 3.3% uncertainty. The improved measurement of H{sub 0}, when combined with the Wilkinson Microwave Anisotropy Probe (WMAP) 7 year data, results in a tighter constraint on the equation-of-state parameter of dark energy of w = -1.08 {+-} 0.10. It also rules out the best-fitting gigaparsec-scale void models, posited as an alternative to dark energy. The combined H{sub 0} + WMAP results yield N{sub eff} = 4.2 {+-} 0.7 for the number of relativistic particle species in the early universe, a low-significance excess for the value expected from the three known neutrino flavors.

79 ASTRONOMY AND ASTROPHYSICS↗