Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform

Complex samples benefit from multidimensional measurements where higher resolution enables more complete characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometer (IMS-Orbitrap MS) platform. To circumvent the time scale disparity between the fast IMS separation and the much slower Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequences to multiplexed injection of ions and allowing operation in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to optimize the signal-to-noise ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data. A new algorithm was developed for the DM analyses involving a two-step process that first recovers the SM data and then decodes the SM data. The algorithm also performs multiple refining procedures in order to minimize demultiplexing artifacts. The new IMS-Orbitrap MS platform was demonstrated by the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Throughput Large-Scale Targeted Proteomics Assays for Quantifying Pathway Proteins in Pseudomonas putida KT2440

Targeted proteomics is a mass spectrometry-based protein quantification technique with high sensitivity, accuracy, and reproducibility. As a key component in the multi-omics toolbox of systems biology, targeted liquid chromatography-selected reaction monitoring (LC-SRM) measurements are critical for enzyme and pathway identification and design in metabolic engineering. To fulfill the increasing need for analyzing large sample sets with faster turnaround time in systems biology, high-throughput LC-SRM is greatly needed. Even though nanoflow LC-SRM has better sensitivity, it lacks the speed offered by microflow LC-SRM. Recent advancements in mass spectrometry instrumentation significantly enhance the scan speed and sensitivity of LC-SRM, thereby creating opportunities for applying the high speed of microflow LC-SRM without losing peptide multiplexing power or sacrificing sensitivity. Here, we studied the performance of microflow LC-SRM relative to nanoflow LC-SRM by monitoring 339 peptides representing 132 enzymes in Pseudomonas putida KT2440 grown on various carbon sources. The results from the two LC-SRM platforms are highly correlated. In addition, the response curve study of 248 peptides demonstrates that microflow LC-SRM has comparable sensitivity for the majority of detected peptides and better mass spectrometry signal and chromatography stability than nanoflow LC-SRM.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a new ion mobility time-of-flight mass spectrometer

Complex samples require multidimensional measurements with high resolution for full characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometry (IMS-Orbitrap MS) platform. To circumvent the timing difference between the fast IMS separation and the slow Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequence to multiplex ions into the drift tube and Orbitrap. The instrument was designed to operate in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to fully optimize the signal-to-ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data, while a new algorithm was developed for the DM analyses. The new algorithm is a two-step process that first recovers the SM data from the encoded DM data and then decoded the SM data. The algorithm also performs multiple refining procedures in order to minimize the demultiplexing artifacts traditionally observed in such scheme. The new IMS-Orbitrap MS platform was demonstrated for the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

47 OTHER INSTRUMENTATION↗

PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

An Integral Activity-Based Protein Profiling Method for Higher Throughput Determination of Protein Target Sensitivity to Small Molecules

Activity-based protein profiling (ABPP) is a chemoproteomic technique that uses small molecule probes to label active enzymes selectively and covalently in complex proteomes. Competitive ABPP, which involves treatment of the active proteome with an analyte of interest, is especially powerful for profiling how small molecules impact specific protein activities. Advances in higher throughput workflows have made it possible to generate extensive competitive ABPP data across diverse biological samples, making this approach highly appealing for characterizing shared and unique proteins affected by perturbations such as drug or chemical exposures. To use the competitive ABPP approach effectively to understand potential adverse effects of chemicals of concern (CoC), a wide range of concentrations may be needed, particularly for chemicals that lack potency or toxicity data. In this work, we present an integral competitive ABPP method that enables target sensitivity determination for different organophosphate (OP) pesticides as model toxicants. Using previously developed OP-ABPs, we optimized conditions for tandem mass tag (TMT) multiplexing of ABPP samples and compared conventional competitive ABPP involving samples at discrete paraoxon concentrations to pooled samples across that same concentration range. We then expanded our approach to compare protein target sensitivities toward two additional OP pesticides, chlorpyrifos oxon and malaoxon. The results showed that differences in integral intensities for the pooled competition sample can be used to evaluate the relative sensitivity of specific proteins without increasing the overall number of samples. For 8 CoC concentrations of interest, this strategy reduced the number of TMT plexes and the corresponding number of LC–MS/MS analyses 3-fold. In conclusion, we envision the integral ABPP (IABPP) method will provide a means to screen diverse chemicals more rapidly to identify both high and low sensitivity protein targets.

activity-based probes↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗