Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measurement and analysis of workload effects on fault latency in real-time systems

The authors demonstrate the need to address fault latency in highly reliable real-time control computer systems. It is noted that the effectiveness of all known recovery mechanisms is greatly reduced in the presence of multiple latent faults. The presence of multiple latent faults increases the possibility of multiple errors, which could result in coverage failure. The authors present experimental evidence indicating that the duration of fault latency is dependent on workload. A synthetic workload generator is used to vary the workload, and a hardware fault injector is applied to inject transient faults of varying durations. This method makes it possible to derive the distribution of fault latency duration. Experimental results obtained from the fault-tolerant multiprocessor at the NASA Airlab are presented and discussed.

Woodbury, Michael H.↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Multiple Embedded Processors for Fault-Tolerant Computing

A fault-tolerant computer architecture has been conceived in an effort to reduce vulnerability to single-event upsets (spurious bit flips caused by impingement of energetic ionizing particles or photons). As in some prior fault-tolerant architectures, the redundancy needed for fault tolerance is obtained by use of multiple processors in one computer. Unlike prior architectures, the multiple processors are embedded in a single field-programmable gate array (FPGA). What makes this new approach practical is the recent commercial availability of FPGAs that are capable of having multiple embedded processors. A working prototype (see figure) consists of two embedded IBM PowerPC 405 processor cores and a comparator built on a Xilinx Virtex-II Pro FPGA. This relatively simple instantiation of the architecture implements an error-detection scheme. A planned future version, incorporating four processors and two comparators, would correct some errors in addition to detecting them.

Bolotin, Gary↗

Investigation of display issues relevant to the presentation of aircraft fault information

This research, performed as a part of NASA Langley's Faultfinder project, investigated display implementation issues related to the introduction of real time fault diagnostic systems into next generation commercial aircraft. Three major issues were investigated: visual display styles for presenting fault related information to the crew, the form the output from the expert system should take, and methods for filtering fault related information for presentation to the crew. Twenty-four flight familiar male volunteers participated as subjects. Five subjects were NASA test pilots, six were Commercial Airline Pilots, seven were Air Force Lear Jet pilots, and six were NASA personnel familiar with flight (non-pilots). Subjects were presented with aircraft subsystem information on a CRT screen. They were required to identify the subsystems presented in a display and to remember the state (normal or abnormal) of subsystem parameter information contained in the display. The results of the study indicated that in the simpler experimental test cases (i.e., those involving single subsystem failures and composite hypothesis displays) subjects' performance did not differ across the different display formats. However, for the more complex cases (i.e., those involving multiple subsystem faults and multiple hypotheses displays), subjects' performance was superior in the text- and picture-based display formats compared to the symbol-based format. In addition, the findings suggest that a layered approached to information display is appropriate.

Allen, Donald M.↗

Study on fault-tolerant processors for advanced launch system

Issues related to the reliability of a redundant system with large main memory are addressed. The Fault-Tolerant Processor (FTP) for the Advanced Launch System (ALS) is used as a basis for the presentation. When the system is free of latent faults, the probability of system crash due to multiple channel faults is shown to be insignificant even when voting on the outputs of computing channels is infrequent. Using channel error maskers (CEMs) is shown to improve reliability more effectively than increasing redundancy or the number of channels for applications with long mission times. Even without using a voter, most memory errors can be immediately corrected by those CEMs implemented with conventional coding techniques. In addition to their ability to enhance system reliability, CEMs (with a very low hardware overhead) can be used to dramatically reduce not only the need of memory realignment, but also the time required to realign channel memories in case, albeit rare, such a need arises. Using CEMs, two different schemes were developed to solve the memory realignment problem. In both schemes, most errors are corrected by CEMs, and the remaining errors are masked by a voter.

Shin, Kang G.↗

Test vectors development and optimization for a microprocessor

This paper describes a method for generating and optimizing test vectors for a microprocessor, with the aid of a fault simulator implemented entirely by hardware. The development and optimization of test vectors has been done on a tester, with the fault simulator plugged directly into the test head. The fault simulator is capable of automatically injecting over a thousand single or multiple stuck faults in the sequential and combinatorial parts of the microprocessor. The test vectors developed by a programmer working interactively with the tester were applied through the tester to the fault simulator, and the percent of faults detected was measured. The vectors were developed and optimized for the 1802 microprocessor, with the objective of detecting 100% of the single stuck faults with a minimum set of vectors. Experimental results show that 99.7% of the single stuck faults are being detected with approximately 14,000 vectors.

Timoc, C. C.↗

Potential damage to DC superconducting magnets due to the high frequency electromagnetic waves

Experimental data are presented in support of the hypothesis that a dc superconducting magnet coil does not behave strictly as an inductor, but as a complicated electrodynamic device capable of supporting electromagnetic waves. Travel times of nanosecond pulses and evidence of sinusoidal standing waves were observed on a prototype four-layer solenoidal coil at room temperature. Ringing observed during switching transients appears as a sequence of multiple reflected square pulses whose durations are related to the layer lengths. With sinusoidal excitation of the coil, the voltage amplitude between a pair of points on the coil exhibits maxima at those frequencies such that the distance between these points is an odd multiple of half wavelength in free space. Evidence indicates that any disturbance, such as that resulting from switching or sudden fault, initiates multiple reflections between layers, thus raising the possibility for sufficiently high voltages to cause breakdown.

Gabriel, G. J.↗

Health Monitoring System for the SSME-fault detection algorithms

A Health Monitoring System (HMS) Framework for the Space Shuttle Main Engine (SSME) has been developed by United Technologies Corporation (UTC) for the NASA Lewis Research Center. As part of this effort, fault detection algorithms have been developed to detect the SSME faults with sufficient time to shutdown the engine. These algorithms have been designed to provide monitoring coverage during the startup, mainstage and shutdown phases of the SSME operation. The algorithms have the capability to detect multiple SSME faults, and are based on time series, regression and clustering techniques. This paper presents a discussion of candidate algorithms suitable for fault detection followed by a description of the algorithms selected for implementation in the HMS and the results of testing these algorithms with the SSME test stand data.

Tulpule, S.↗

Guest Editorial: Planning and operation of resilient distribution system for integrated multi-energy

Resilience is the ability of power systems to prepare for and adapt to low-probability, high-impact incidents and withstand and recover rapidly from disruptions. With the ageing of electricity distribution infrastructure and increasing threats of weather-related incidents and natural disasters, the need to effectively enhance the resilience of the electricity distribution system has become urgent and has attracted worldwide attention. Although there are an increasing number of publications related to enhancing resilience strategies, resilience is an emerging concept in power systems. Existing practices are mostly focused on deploying distributed energy resources (DERs) and microgrids, hardening the existing infrastructures and building redundant capacities. However, from a broader perspective, resilience enhancement of power distribution system is a systematic engineering, involving long-term system planning and upgrading (e.g., deployment of smart grid technologies and intelligent switches), short-term proactive scheduling, real-time robust and resilient control of DERs, and post-event restoration and recovery strategies. Based on this point, this Special Issue in IET Energy System Integration focuses on soliciting the most recent and original technologies, scheduling and control strategies for improving the resilience of power distribution system. Eight papers are presented in this Special Issue, covering various aspects related to resilience enhancement of power distribution system, including fault-tolerant frequency measurement, robust scheduling of integrated electricity and district heating systems, robust control of DERs, efficient methods for safety verification as well as novel graph theory-based approach to restore the distribution systems after multiple simultaneous faults. A brief introduction of these 8 papers is provided below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor cost-effectiveness analysis for data-driven fault detection and diagnostics in commercial buildings

Data-driven building fault detection and diagnostics (FDD) is heavily dependent on sensors. However, common sensors from Building Automation Systems are not optimized to maximize accuracy in FDD. Installing additional sensors that provide more detailed building system information is key to maximizing the performance of FDD solutions. Here in this paper, we present a sensor cost analysis workflow to quantify the economic implications of installing new sensors for FDD using the concept of sensor threshold marginal cost (STMC). STMC does not represent actual sensor cost. Rather, it represents a target cost based on the economic benefit that would be realized through improved FDD performance and one or more specified economic criteria. We calculate STMCs for multiple possible fault types and use fault prevalence information to aggregate STMCs into a single dollar value to determine the cost-effectiveness of a potential sensor investment. We conducted a case study using Oak Ridge National Laboratory's Flexible Research Platform (FRP) test facility as a reference. The case study demonstrates the feasibility of the analysis and highlights the key cost considerations in sensor selection for FDD. The results also indicate that identifying and installing the few key sensor(s) is critical to cost-effectively improve FDD performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review: Induced Seismicity During Geoenergy Development—A Hydromechanical Perspective

The basic triggering mechanism underlying induced seismicity traces back to the mid-1960s that relied on the process of pore-fluid pressure diffusion. The last decade has experienced a renaissance of induced seismicity research and data proliferation. An unprecedent opportunity is presented to us to synthesize the robust growth in knowledge. The objective of this article is to provide a concise review of the triggering mechanisms of induced earthquakes with a focus on hydro-mechanical processes. Four mechanisms are reviewed: pore-fluid pressure diffusion, poroelastic stress, Coulomb static stress transfer, and aseismic slip. For each, an introduction of the concept is presented, followed by case studies. Diving into these mechanisms sheds light on several outstanding questions. For example, why did some earthquakes occur far from fluid injection or after injection stopped? Our review converges on the following conclusions: (a) Pore-fluid pressure diffusion remains a basic mechanism for initiating inducing seismicity in the near-field. (b) Poroelastic stresses and aseismic slip play an important role in inducing seismicity in regions beyond the influence of pore-fluid pressure diffusion. (c) Coulomb static stress transfer from earlier seismicity is shown to be a viable mechanism for increasing stresses on mainshock faults. (d) Multiple mechanisms have operated concurrently or consecutively at most induced seismicity sites. (e) Carbon dioxide injection is succeeding without inducing earthquakes and much can be learned from its success. Future research opportunities exist in deepening the understanding of physical and chemical processes in the nexus of geoenergy development and fluid motion in the Earth’s crust.

58 GEOSCIENCES↗

Initial Implementation Of Machine Learning System for SRF Cavity Fault Classification at CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is high power CW electron accelerator. It uses a mixture of two types of SRF modules, older, lower energy C20/C50 modules and newer higher energy C100 modules, arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from EPICS and saved for review. Analysis of these waveforms is time intensive and requires subject matter expertise (SME). SMEs examine the data from each event and label it according to one of several known cavity fault types. Multiple machine learning models have been developed on this labeled dataset with sufficient performance to warrant the creation of a limited machine learning software system for use by accelerator operations staff. This paper discusses the transition from model development to implementation of a prototype system.

Carpenter, A.↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Empirically based analysis of failures in software systems

An empirical analysis of software-system failures is used to study several specific issues in software testing, reliability analysis, and reuse. Failure data from a large software manufacturer and a NASA production environment were collected and analyzed. The systems ranged in size from 30,000 to over 100,000 lines. The results show that (1) the first 15 percent of the test cases detected 67 percent of the high-severity failures and 50 percent of all failures; (2) multiple fault-detection and testing phases may result in a significant increase in reliability or none at all; (3) composite measures of system reliability did not adequately reflect reliability at the function or component level; (4) developers were biased toward portions of systems that would be heavily tested; (5) fault-proneness of reused or modified components was 74 percent less than that of newly developed components; and (6) systems with more reused software had lower component development effort, but not lower component fault-proneness.

Selby, Richard W.↗