At least 73 records · Page 4

Electrospun Nanofiber Electrodes for High and Low Humidity PEMFC Operation

MEAs with nanofiber mat electrodes containing Pt/C catalyst and Nafion binder were fabricated and evaluated. The electrodes were prepared by electrospinning a solution of catalyst powder, salt-form Nafion (with Na + , Li + , or Cs + as the sulfonic acid counterion), and a carrier polymer of either polyethylene oxide or poly(acrylic acid). The carrier polymer was extracted prior to MEA testing by a hot water soaking step. The resulting fibers were 15%–17% porous, with a core–shell-like morphology (a coating of primarily Nafion on the fiber surface). MEAs with anode/cathode catalyst loadings of 0.1 mg Pt cm −2 each and a Nafion 211 membrane produced high power at both high and low relative humidity (RH) conditions in H 2 /air fuel cell tests, e.g., a maximum power density of 919 mW cm −2 at 100% RH and 832 mW cm −2 at 40% RH for a test at 80 °C and 200 kPa abs . The presence of nm-size pores within the fibers trapped water via capillary condensation during low RH feed gas testing, thus maintaining a high proton conductivity of the Nafion binder in the anode and cathode while minimizing/eliminating ionic isolation of catalyst particles in low water content, poorly conductive binder.

25 ENERGY STORAGE↗

Anti-Icing Coatings using Ionomer Film Layer Structuring

This research effort examined the application of Nafion polymers in alcohol solvents as an anti-ice surface coating, as a mixture with hydrophilic polymers and freezing point depressant salt systems. Co-soluble systems of Nafion, polymer and salt were applied using dip coating methods to create smooth films for frost observation over a Peltier plate thermal system in ambient laboratory conditions. Cryo-DSC was applied to examine freezing events of the Nafion-surfactant mixtures, but the sensitivity of the measurement was insufficient to determine frost behavior. Collaborations with the Fog Chamber at Sandia-Albuquerque, and in environmental SAXS measurements with CINT-LANL were requested but were not able to be performed under the research duration. Since experimental characterization of these factors is difficult to achieve directly, computational modeling was used to guide the scientific basis for property improvement. Computational modeling was performed to improve understanding of the dynamic association between ionomer side groups and added molecules and deicing salts. The polyacrylic acid in water system was identified at the start of the project as a relevant system for exploring the effect of varying counterions on the properties of fully deprotonated polyacrylic acid (PAA) in the presence of water. Simulations were modeled with four different counterions, two monovalent counterions (K+ and Na+) and two divalent counterions (Ca2+ and Mg2+). The wt% of PAA in these systems was varied from ~10 to 80 wt% PAA for temperatures from 250K to 400K. In the second set of simulations, the interpenetration of water into a dry PAA film was studied for Na+ or Ca2+ counterions for temperatures between 300K and 400K. The result of this project is a sprayable Nafion film composite which resists ice nucleation at -20 °C for periods of greater than three hours. It is composed of Nafion polymer, hydrophilic polyethylene oxide polymer and CaCl2 anti-ice crosslinker. Durability and field performance properties remain to be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Study on the Synthesis and Proton Transport Behavior of Multilayered ZSM-5 Zeolite Nanosheet Membranes Laminated on Polymer Substrates

Single crystalline ZSM-5 ZNs with thicknesses around 6 nm were obtained by secondary growth of silicalite nanoparticles using diquaternary bis-1,5(tripropyl ammonium) pentamethylene diiodide (dC5) as a structure-directing agent (SDA). The dC5 could be effectively removed from the ZN pores by either high-temperature calcination or UV irradiation in air at room temperature but not by the piranha solution treatment. Ultrathin ZN-laminated membranes (ZNLMs) were fabricated by sandwiching a UV-activated multilayered ZN film between two recast Nafion® layers (ZNLM-Nafion) and by filtration coating from a suspension of thermally activated ZNs on a nonionic porous PVDF (ZNLM-PVDF). The ZNLMs on both supports demonstrated the ability of highly proton-selective ion conduction with low resistances in aqueous electrolyte solutions. The ZNLM-PVDF with PVDF binder was structurally stable, and it achieved a comparably low ASR but much higher proton selectivity compared with a Nafion membrane of same overall thickness. However, detachment between the ZNLM and Nafion layers occurred when the ZNLM-Nafion operated in aqueous electrolyte solutions. Results of this study show the potential for developing ZNLMs as efficient proton-conducting membranes without using expensive ionic polymer matrices. However, the development of polymer-supported ZNLMs is hindered by the current inefficiency in preparing well-dispersed suspensions of open-pore ZNs. Future development of efficient methods for synthesizing open-pore ZNs in dispersed states is key to realizing high-performance ZNLMs on polymers.

36 MATERIALS SCIENCE↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Pt-Metal Alloy Catalysts with Various Ionomers on Oxygen Reduction Reaction in Fuel Cell Application

Pt-M/C (M = Co, Ni, Mn, etc.) alloy catalysts exhibit superior oxygen reduction reaction (ORR) activity compared to pure Pt/C, leading to a high energy efficiency in hydrogen fuel cells. However, many Pt-M/C alloy catalysts were synthesized and evaluated at the lab scale in model test-bed systems like rotating disc electrodes, which don't always correlate to performance within a fuel cell system; there is a clear need to evaluate catalysts in electrodes that can be prepared at industrially relevant scales to evaluate how factors like ink formulation can greatly affect device-level of fuel cell performance. Herein, three commercial Pt-M/C alloy catalysts (two Pt-Co/C and one Pt-Ni/C) were comprehensively characterized by various techniques. The results show that the average particle sizes of the three catalysts are close to 5 nm; the atomic ratio of Pt/M is around 4; and the M was successfully embedded into Pt lattice, resulting in the positive shift of Pt 4f in XPS spectra and XRD patterns. These catalytic materials were incorporated into 9 different cathode catalyst layers (CCLs) with three kinds of ionomers (Nafion D2020, high oxygen permeability ionomer (HOPI), and Aquivion D79-25BS), and their performance in proton exchange membrane fuel cells (PEMFCs) were investigated. The results demonstrate that the Pt-Co/C catalysts possess a higher mass activity (MA) than Pt-Ni/C; the cathodes with Nafion ionomer provide the highest MA while electrodes with Aquivion ionomer showed the lowest activity, attributed to poor H+ conductivity resulting from suboptimal ionomer incorporation. Finally, these alloys were shown to exceed DOE targets for MA and H2/Air performance reported in the recent publications at beginning of life and after 90k cycle catalyst AST protocol. This study provides valuable performance benchmarks for these materials guiding future Pt-M/C catalyst design and material integration for heavy duty PEMFC applications.

08 HYDROGEN↗

Solvent absorption rate of perfluorosulphonic acid membranes towards understanding direct coating processes

Here we present a method for measurement of the rate of solvent absorption by perfluorosulfonic acid (PFSA) membranes using a force tensiometer. The method presented here can be used as a tool to understand solvent absorption and should provide a rationale for designing catalyst inks for direct coating processes since it is necessary to understand how the absorption rate – on a time scale of seconds to minutes – compares to the time scales of the coating process in order to minimize membrane swelling. This method allows for rapid screening of the absorption and swelling behavior of different solvents and mixtures. Using this method, the absorption of water/1-propanol mixtures were measured for three thicknesses of Nafion PFSA membrane – Nafion 1135, Nafion 115, and Nafion 117. We find that the absorption rate is dependent on the ratio of the solvents as well as the thickness of the membrane. The analysis indicates that the highest absorption rate occurs when the mass percentage of 1-propanol in the mixture is 50%, whereas the lowest rates are for pure water and 1-propanol. In addition, membrane distortion also occurs most quickly for the 50% 1-propanol mixture. Our results suggest that catalyst inks that are highly rich (=90%) in water or 1-propanol are likely best for direct coating as such formulations will minimize absorption and swelling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How the Hydrophobic Interface between a Perfluorosulfonic Acid Polymer and Water Vapor Controls Membrane Hydration

Stable hydration in perfluorinated polyelectrolyte membranes such as Nafion is essential to maintain good ion conductivity and manage permeation, especially in vapor-fed devices where water content depends on relative humidity in a gas stream. Extensive studies in the literature have shown that Nafion hydration in water vapor is controlled by its interfacial transport resistance. Nafion forms a fluorine-rich layer at the polymer-gas interface, and it has been proposed that this layer blocks water transport due to its hydrophobicity. To develop a molecular-level description of the physics underlying transport resistance in this system, we have performed a computational reaction-diffusion kinetics study of water evaporation from Nafion. Two distinct models are examined, one mimicking the blocking function proposed in the literature and the other assuming that there is no blocking, treating instead water evaporation as a dynamic balance between uptake from the gas and desorption from the polymer surface. Simulation results are compared to time-dependent infrared data over a range of 100-0% relative humidity from the literature. Only the dynamic model successfully reproduces experimental observations. This indicates that the physical nature of interfacial transport resistance is not slow diffusion across an interfacial layer; rather, it is due to the competition between dehydration and rehydration. The simulation data provide details on the accompanying water distributions throughout the membrane and on interfacial kinetics, showing that they are characterized by strong fluctuations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Room Temperature, Dip Coating Organic Passivation for c-Si Surfaces

Surface passivation of crystalline Si (c-Si) to reduce recombination rate is crucial to obtain high-efficiency c-Si solar cells. A fast passivation technique that can be performed at room temperature is needed when studying the degradation behaviors using various characterization methods to not destroy the degraded states. In this contribution, we explore Nafion via dip coating on n-type Cz wafers. We show that both the Nafion concentration and the conditions of surface and edge affect the passivation quality, and we achieve excellent passivation quality of iVoc of 716 mV, with a saturation current density (J0) of 7 fA/cm2. Additionally, electron paramagnetic resonance (EPR) shows Nafion can be used under cryogenic temperature and reveals the reduction of Si dangling bond after Nafion treatment.

dielectric solar cell↗

Selective concentration of multivalent cations via electrodialysis through tandem membranes

Selective electrodialysis is attractive for recovering and recycling valuable ions. However, most studies in this field focus on membranes that are selective for monovalent ions. Multivalent cations preferentially partition into cation-exchange membranes, but low mobilities and concentration polarization limit electrodialysis selectivities for these cations. This work employs electrodialysis through an “in-series” combination of a Nafion membrane and a multilayer polyelectrolyte film (MPF)-coated Nafion membrane to concentrate and isolate La 3+ or Mg 2+ from monovalent ions. The bare Nafion membrane gives a La 3+ /Na + selectivity up to 4 (depending on conditions), which enables concentration of La 3+ with a high current efficiency. The MPF-coated membrane allows selective passage of Na + while rejecting La 3+ to increase the purity of the concentrated multivalent cation. For example, the concentration of La 3+ in the accumulation solution can reach 9 times its original concentration in the feed solution with a purity of 93 mol% (99 wt%) when starting with equimolar mixtures of NaNO 3 and La(NO 3 ) 3 . This study examines how the separation varies with the type of polyelectrolyte, the applied voltage, and the composition of feed, accumulation, and cathode solutions. Here, a high nitric acid concentration (0.5 M) in the cathode compartment allows monovalent anions to pass through the MPF-coated Nafion membrane to maintain the electroneutrality of the accumulation solution. With a low acid concentration (0.04 M) in the cathode chamber, water splitting occurs at the MPF-coated membrane and La(OH) 3 precipitates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental observation of nonlinear relation between pressure and water flux is consistent with the solution-diffusion model

In several recent studies, it has been proposed that the fundamental understanding of penetrant transport in dense polymer membranes occurring via the solution-diffusion model, which has been the generally accepted theoretical framework for describing penetrant transport in such materials for the past several decades, is flawed. An alternate mechanistic framework based on the idea of two-phase flow in a porous medium (i.e., pore-flow) has been broadly advanced instead, with proponents of this approach claiming that the pore-flow theoretical framework provides the necessary mechanistic insight to design novel polymeric membrane materials for emerging applications. In this study, we show experimental results for hydraulic permeation of water that are entirely consistent with the solution-diffusion theory, without modification, for three dense polymeric membranes: crosslinked poly(ethylene glycol diacrylate) (XLPEGDA), Nafion 117 ionomer in the sodium counterion form (Nafion 117-Na), and cellulose acetate (CA). By measuring water flux at transmembrane pressures up to 240 bar, we observe a nonlinear relationship between the transmembrane pressure (TMP) and water flux, J w , for XLPEGDA and Nafion 117-Na, while this relationship is linear for CA. We demonstrate that the behavior of these three materials is described via the solution-diffusion model. According to the solution-diffusion model, flux is, to a good approximation, proportional to the transmembrane concentration difference induced by the pressure difference across the membrane, rather than to TMP itself. Water sorption isotherms are reported for all three materials. They further justify the nonlinear relationship between TMP and J w observed in XLPEGDA and Nafion 117-Na, emphasizing that the nonlinearity in the flux/TMP relationship stems from nonlinearities in the sorption isotherm with pressure. Additionally, the relationship between water flux and TMP can be predicted, a priori, with no adjustable parameters when a predictive model for the diffusion coefficient of water is employed in conjunction with the experimental water sorption isotherms in the solution-diffusion model. Furthermore, our results demonstrate the validity of the solution-diffusion model to describe transport of penetrants in dense polymer membranes, while highlighting the sensitivity of the solution-diffusion model to the many physical and mathematical simplifications commonly applied to the theory in literature.

materials↗

Origin of Unusual Acidity and Li+ Diffusivity in a Series of Water-in-Salt Electrolytes.

Superconcentrated aqueous electrolytes ("water-in-salt" electrolytes, or WiSEs) enable various aqueous battery chemistries beyond the voltage limits imposed by the Pourbaix diagram of water. However, their detailed structural and transport properties remain unexplored and could be better understood through added studies. Here, we report on our observations of strong acidity (pH 2.4) induced by lithium bis(trifluoromethane sulfonyl)imide (LiTFSI) at superconcentration (at 20 mol/kg). Multiple nuclear magnetic resonance (NMR) and pulsed-field gradient (PFG) diffusion NMR experiments, density functional theory (DFT) calculations, and molecular dynamics (MD) simulations reveal that such acidity originates from the formation of nanometric ion-rich structures. The experimental and simulation results indicate the separation of water-rich and ion-rich domains at salt concentrations >= 5 m and the acidity arising therefrom is due to deprotonation of water molecules in the ion-rich domains. As such, the ion-rich domain is composed of hydrophobic -CF3 (of TFSI-) and hydrophilic hydroxyl (OH-) groups. At 20 m concentration, the tortuosity and radius of water diffusion channels are estimated to be similar to 10 and similar to 1 nm, respectively, which are close to values obtained from hydrated Nafion membranes that also have hydrophobic polytetrafluoroethylene (PTFE) backbones and hydrophilic channels consisting of SO3- ion cluster networks providing for the transport of ions and water. Thus, we have discovered the structural similarity between WiSE and hydrated Nafion membranes on the nanometer scale.

Han, Kee Sung↗

Revealing Mesoscale Ionomer Membrane Structure by Tender Resonant X-ray Scattering

Nafion, a perfluorosulfonic acid ionomer, has been well-studied for decades due to its key role as an ion-conductive membrane in electrochemical energy conversion and storage applications. When hydrated, this membrane phase separates into a complex hierarchical nanostructure with hydrophilic domains that facilitate ion transport. Hard X-ray scattering has been a powerful technique in understanding Nafion due to its capabilities in capturing the ionomer’s nanophase separated structure, which gives rise to contrast between polymer and water domains. More recently, resonant X-ray scattering, which tunes to elemental absorption edges to provide specificity on constituent elements, has been explored to highlight key interactions related to the sulfonic acid groups within its structure. Here, in this work, we study the Nafion nanostructure by combining hard X-ray scattering and tender resonant X-ray scattering (TReXS) at the sulfur K-edge to reveal a mesoscopic feature corresponding to a correlation length of approximately 40 nm that has been challenging to resolve with hard X-ray studies. Additionally, we study the effect of the dispersion solvent composition that plays a key role in the formation of this mesoscale feature. Notably, TReXS can attain high contrast to decipher this mesoscale morphology even for dry polymer membranes under a vacuum, which typically have reduced contrast for hard X-rays. We find that the correlation length of this mesoscale feature decreases with increasing water fraction in the dispersion, which is the opposite trend exhibited by the smaller intercrystalline feature in the same membranes. This study showcases the utility of TReXS to uncover multiscale morphological details in functional polymers that are not always revealed by other methods like hard X-ray scattering. We illustrate this with Nafion, which is a relevant ion-conducting polymer for electrochemical technologies.

36 MATERIALS SCIENCE↗

Development of Machine-Learned Interatomic Potentials to Predict Structure, Transport, and Reactivity in Platinum-Based Fuel Cells

Machine-learned interatomic potentials (MLIPs) have rapidly progressed in accuracy, speed, and data efficiency in recent years. However, training robust MLIPs in multicomponent systems remains a challenge. In this work, we train an MLIP to describe hydrated Nafion ionomers and platinum catalysts, which are important components of fuel cells, by constructing a diverse training set to describe the bulk polymer and interfacial catalyst–polymer interactions well. We use our trained MLIP to study the properties of the platinum–Nafion system, including polymer structure, proton mobility in a bulk Nafion polymer and near a platinum-Nafion interface, and reactions near and far from the interface, finding excellent results for structure and reactions contained within our training set. Transport seems to be well described, with both vehicular transport and Grotthuss hopping captured, although converged calculations of diffusivities were not computed because they require calculations of tens of nanoseconds that are challenging with current state-of-the-art MLIPs. The combined insights that this model provides can be leveraged to optimize fuel cell performance, and the approach can be applied to other chemical processes and devices where structure, transport, and reactivity all contribute to the overall observed performance.

33 ADVANCED PROPULSION SYSTEMS↗

Molecular-Level Control over Ionic Conduction and Ionic Current Direction by Designing Macrocycle-Based Ionomers

Poor ionic conductivity of the catalyst-binding, submicrometer- thick ionomer layers in energy conversion and storage devices is a huge challenge. However, ionomers are rarely designed keeping in mind the specific issues associated with nanoconfinement. Here, we designed nature-inspired ionomers (calix-2) having hollow, macrocyclic, calix[4]arene-based repeat units with precise, sub-nanometer diameter. In ≤100 nm-thick films, the in-plane proton conductivity of calix-2 was up to 8 times higher than the current benchmark ionomer Nafion at 85% relative humidity (RH), while it was 1-2 orders of magnitude higher than Nafion at 20-25% RH. Confocal laser scanning microscopy and other synthetic techniques allowed us to demonstrate the role of macrocyclic cavities in boosting the proton conductivity. The systematic self-assembly of calix-2 chains into ellipsoids in thin films was evidenced from atomic force microscopy and grazing incidence small-angle X-ray scattering measurements. Moreover, the likelihood of alignment and stacking of macrocyclic units, the presence of one-dimensional water wires across this macrocycle stacks, and thus the formation of long-range proton conduction pathways were suggested by atomistic simulations. We not only did see an unprecedented improvement in thin-film proton conductivity but also saw an improvement in proton conductivity of bulk membranes when calix-2 was added to the Nafion matrices. Nafion-calix-2 composite membranes also took advantage of the asymmetric charge distribution across calix[4]arene repeat units collectively and exhibited voltage-gating behavior. The inclusion of molecular macrocyclic cavities into the ionomer chemical structure can thus emerge as a promising design concept for highly efficient ion-conducting and ion-permselective materials for sustainable energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polysulfide-Permanganate Flow Battery Using Abundant Active Materials

A new flow battery is presented using the abundant and inexpensive active material pairs permanganate/manganate and disulfide/tetrasulfide. A wetted material set is identified for compatibility with the strongly oxidizing manganese couple at ambient and elevated temperatures. Both solutions allow high active material solubility, with cells tested at theoretical energy densities up to 43 Wh l −1 for the ∼1.2 V cell. Full cells built with nickel foam electrodes and sodium-exchanged Nafion 115 membranes deliver a baseline area-specific resistance of 2.7 Ω-cm 2 . Incorporation of high-surface-area cobalt-coated carbon paper and high-surface-area stainless steel mesh electrodes, and an expanded Nafion 115 membrane delivers cells with 44% lower resistance at 1.6 Ω-cm 2 . All cells show performance decay over the course of cycling. The Co-decorated carbon paper electrodes provide significant kinetic improvements, shifting electrode performance from non-linear with Ni-foam to linear with a volume-normalized exchange current density value of 3.2 A cm −3 . The expanded membrane provides increased conductivity over the 13 mS cm −1 conductivity observed in as-received, sodium-exchanged Nafion 115. Although boiled membranes provide improved conductivity, it is at the cost of decreased Coulombic efficiency and poorer manufacturability. Full cell models suggest that similar cell resistances (1.7 Ω-cm 2 ) should be feasible with as-received Nafion 115 and advanced electrodes.

25 ENERGY STORAGE↗

Meso-Structured Polymer Electrolyte Fuel Cell Electrode

Increasing the utilization of Pt and Pt alloy catalysts in polymer electrolyte fuel cell cathodes is critical to improving the high power density operation, particularly at low Pt loadings. State of the art electrodes are fabricated in an ink deposition process that leads to uncontrolled electrode architecture with random aggregates of functional domains (catalyst, ionomer, and pore volume) (1). The randomness in the domains induces high tortuosity transport pathways for ions and fluids, which cause severe transport resistance during high current density operation. Thin ionomer films cause additional transport resistance and poisoning of the Pt catalyst, which becomes more significant at low Pt loadings. Reducing the amount of ionomer in the catalyst domain without affecting the ionic transport resistance is key to improving the utilization of the Pt and reducing the transport resistance at low Pt loading. Rational design of the electrode structure with controlled low tortuous ionic transport pathways could improve performance. The introduction of the ionomer pathways could also enable reduction of the ionomer volume in the catalyst domain, reducing the transport resistance. Middelmen et al. proposed electrode structures consisting of aligned components in a low tortuosity configuration to improve performance (2). In this work, we present an alternative electrode structure based on a vertically aligned array of Nafion pillars in the cathode catalyst layer, as shown in Figure 1a. Figure 1b shows the SEM image of the Nafion pillars. Furthermore, Pt supported on carbon catalyst was deposited on the Nafion pillars to fabricate a meso-structured electrode. Nafion pillars provide high conductive and low tortuous pathways for protons, reducing the effective transport distance, and enabling reduction of the ionomer binder in the catalyst domain.

25 ENERGY STORAGE↗

High Temperature Polymers for use in Fuel Cells

NASA Glenn Research Center (GRC) is currently working on polymers for fuel cell and lithium battery applications. The desire for more efficient, higher power density, and a lower environmental impact power sources has led to interest in proton exchanges membrane fuels cells (PEMFC) and lithium batteries. A PEMFC has many advantages as a power source. The fuel cell uses oxygen and hydrogen as reactants. The resulting products are electricity, heat, and water. The PEMFC consists of electrodes with a catalyst, and an electrolyte. The electrolyte is an ion-conducting polymer that transports protons from the anode to the cathode. Typically, a PEMFC is operated at a temperature of about 80 C. There is intense interest in developing a fuel cell membrane that can operate at higher temperatures in the range of 80 C- 120 C. Operating the he1 cell at higher temperatures increases the kinetics of the fuel cell reaction as well as decreasing the susceptibility of the catalyst to be poisoned by impurities. Currently, Nafion made by Dupont is the most widely used polymer membrane in PEMFC. Nafion does not function well above 80 C due to a significant decrease in the conductivity of the membrane from a loss of hydration. In addition to the loss of conductivity at high temperatures, the long term stability and relatively high cost of Nafion have stimulated many researches to find a substitute for Nafion. Lithium ion batteries are popular for use in portable electronic devices, such as laptop computers and mobile phones. The high power density of lithium batteries makes them ideal for the high power demand of today s advanced electronics. NASA is developing a solid polymer electrolyte that can be used for lithium batteries. Solid polymer electrolytes have many advantages over the current gel or liquid based systems that are used currently. Among these advantages are the potential for increased power density and design flexibility. Automobiles, computers, and cell phones require highly efficient power density for lowering emissions and meeting increasing consumer demands. Many of the solutions can be provided by proton exchange membrane fuel cells and lithium batteries. NASA Glenn Research Center has recognized this need, and is presently engaged in a solution. The goals for the summer include mastering synthesis techniques, understanding the reactions occurring during the synthesis, and characterizing the resulting polymer membranes using NMR, DSC, and TGA for the PEMFC and lithium batteries.

Peplowski, Katherine M.↗

Nonhumidified High-Temperature Membranes Developed for Proton Exchange Membrane Fuel Cells

Fuel cells are being considered for a wide variety of aerospace applications. One of the most versatile types of fuel cells is the proton-exchange-membrane (PEM) fuel cell. PEM fuel cells can be easily scaled to meet the power and space requirements of a specific application. For example, small 100-W PEM fuel cells are being considered for personal power for extravehicular activity suit applications, whereas larger PEM fuel cells are being designed for primary power in airplanes and in uninhabited air vehicles. Typically, PEM fuel cells operate at temperatures up to 80 C. To increase the efficiency and power density of the fuel cell system, researchers are pursuing methods to extend the operating temperature of the PEM fuel cell to 180 C. The most widely used membranes in PEM fuel cells are Nafion 112 and Nafion 117--sulfonated perfluorinated polyethers that were developed by DuPont. In addition to their relatively high cost, the properties of these membranes limit their use in a PEM fuel cell to around 80 C. The proton conductivity of Nafion membranes significantly decreases above 80 C because the membrane dehydrates. The useful operating range of Nafion-based PEM fuel cells can be extended to over 100 C if ancillary equipment, such as compressors and humidifiers, is added to maintain moisture levels within the membrane. However, the addition of these components reduces the power density and increases the complexity of the fuel cell system.

Kinder, James D.↗