Search NASA⌕ Search

SEARCH · Search NASA

Results for “network analysis and control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Developing ML/AI Methods for High-Throughput Characterization of Multiple-Sensor Streams of Tokamak Dynamics for High-Speed Control (Final Report)

This project evaluated and developed new mathematical and algorithmic techniques capable of handling (in real-time) the growing amounts of data generated by modern fusion research. While existing numerical linear algebra (NLA) methods provide the backbone to classical data analysis and algorithms, these methods fundamentally do not port to distributed architectures nor do they allow low-latency data reduction for control. Motivated by the needs for modern fusion reactors, this project explored and implemented new numerical methods to characterize plasma dynamics, respond in real-time to discharge evolution, and to process massive-scale data accurately and rapidly more fully. This project links expertise in multiple-sensor diagnostics of tokamak plasma dynamics from Columbia University’s Plasma Physics Laboratory with expertise in massive-scale data reduction and extreme data control algorithms at Columbia University’s Data Science Institute. This interdisciplinary project (i) applied machine learning methods, (ii) implemented a properly-trained neural-network for very fast processing of high-speed plasma videography, and (ii) developed the applied mathematical methods, based on randomized-NLA (rNLA) routines, for data analysis, reduction, and real-time control. The Columbia University High Beta Tokamak-Extended Pulse (HBT-EP) facility provided data to test new algorithms and partnership with Columbia University's Data Sciences Institute evaluated the broader use of new algorithms for many challenging control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-strength 3D printed poly(lactic acid) composites reinforced by shear-aligned polymer-grafted cellulose nanofibrils

This work demonstrates the application of pilot-scale surface functionalization of cellulose nanofibrils (CNFs) by aqueous grafting-through polymerization and subsequent spray drying in 3D printed poly(lactic acid) (PLA) composites. Grafted-CNF composites attain an ultimate tensile strength of 88 ± 3 MPa and a tensile modulus of elasticity of 7.8 ± 1.3 GPa in the printing direction at 20 wt% reinforcement loading. These increases, 42% and 139% over neat PLA, respectively, represent the strongest reported 3D printed CNF/PLA composite to date in the literature. The mechanisms behind these improvements are investigated by comparisons to neat PLA and unmodified spray-dried CNF/PLA controls using melt rheology, dynamic mechanical analysis, and assessment of the reinforcement dispersion. These experiments reveal that improved network formation and shear-induced alignment of the grafted CNFs facilitate the remarkable tensile properties of the printed composites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Tradeoff Analysis of Series / Parallel Three-Phase Converter Topologies for Wireless Extreme Chargers

In this paper, extreme fast charging (XFC) technology is studied considering the charge rates of 300 kW for wireless power transfer (WPT) applications. Tradeoff analysis of series and parallel connection of three-phase WPT system are presented by comparisons of voltage and current stresses on power electronics active / passive components. In addition, star (Y) / delta (Δ) connection configurations for three-phase wireless power transfer coupling coils are analyzed with series and LCC resonant compensation circuits. The system series and parallel connection controllability is also reviewed considering voltage and current balance techniques with output control. In a conclusion of evaluation analysis, it is revealed that each component of 300 kW wireless charging network must be designed for high fast charging system and the overall system operation need to be strategically planned for high power charging and infrastructure deployment.

Asa, Erdem↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

GradientGraph

Under this SBIR Phase II, Reservoir Labs has developed G2 Analytics, a new technology that allows network operators to analyze bottleneck and flow performance with high precision. G2 delivers a new analytical approach and framework to resolve a variety of key problems found in modern communication networks, including: traffic engineering, routing, flow scheduling, network design, capacity planning, resiliency analysis, network slicing, or service level agreement (SLA) management, among others. G2 leverages the bottleneck structure of congestion-controlled communication networks, a recent mathematical discovery by the Reservoir team [RL19b, RL20a, RL20b, RL21a]. Bottleneck structures reveal how perturbations on flows and links propagate through the network, providing an analytical framework to measure (qualitatively and quantitatively) the ripple effects induced as they traverse the network. Leveraging the mathematics of bottleneck structures, Reservoir Labs is developing the G2 technology to provide network operators with a framework to design, optimize and troubleshoot network performance. This delivery includes the G2 software stack.

Yellamraju, Sruthi↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

Deployable sensor system using mesh networking and satellite communication

A sensor system may be configured for continuous operation in a low resource environment and/or in extreme environmental conditions. The sensor system may have sufficient processing capabilities to provide scientific computing for pre-processing, quality control, statistical analysis, event classification, data compression and corrections (e.g., spikes in the data), autonomous decisions and actions, triggering other nodes, and information assurance functions that provide data confidentiality, data integrity, authentication, and non-repudiation. The hardware may have both mesh networking and satellite and cellular communication capability, and may be available for relatively low cost. Such a network provides the flexibility to have potentially any number of nodes be completely independent from one another. Thus, the network may scale across a diverse terrain.

Frigo, Janette↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Throughput Measurements and Profile Analysis of Cloud Networks

Cloud networks utilize virtual connections to connect virtual machines distributed across cloud sites. They are increasingly deployed due to flexible provisioning using software and cost-effectiveness in not requiring to build physical network infrastructure. However, their extensive virtualization makes it unclear how well the established practices of conventional networks translate to them. Here, we study throughput measurements over a Google Cloud network using a matching hardware emulated conventional network, which provide production and exploratory conditions, respectively. The measurements span connections representing local, cross-continental and around the Earth distances. We study the effects of parallel flows, congestion control algorithms and retransmissions on the network throughput profile expressed as a function of RTT. We compare the throughput profile of Google Cloud network with those of emulated network under various loss conditions, including those too disruptive or expensive in the former. Our analysis based on the concave-convex shape and utilization-concavity coefficients of throughput profiles indicates an overall agreement of performance between the two networks, thereby justifying the use of conventional network emulations to analyze cloud networks. In terms of practical use, our study establishes that BBR and BBRv2 alpha TCP achieve higher throughput compared to loss-based congestion control algorithms under most network configurations, especially, under losses at large RTT.

Phanekham, Derek [Southern Methodist Univ., Dallas↗

Fracture Characterization Via AI‐Assisted Analysis of Temperature Logs

Abstract Fractures control fluid flow, mass transport, and heat transfer in a geothermal reservoir. This makes accurate characterization of fracture networks a prerequisite for optimal design and control of a reservoir's exploitation. We develop a deep‐learning procedure to identify fracture locations via interpretation of temporally and spatially continuous downhole temperature measurements. A long short‐term memory fully convolutional network (LSTM‐FCN) is used both to capture long‐term dependencies in sequential temperature data and to distill local features around fractures. A wellbore and fractured‐reservoir thermal model is established to generate temperature data for network training. The trained LSTM‐FCN exhibits a unique ability to detect multiple fractures intersecting a borehole. We use the LSTM‐FCN algorithm to evaluate the effectiveness of different‐stage wellbore temperature measurements on fracture detection in a complex fractured system. Our experiments reveal that the use of various‐stage temperature information as an input feature set improves the robustness of fracture detection to noise interference. This study indicates the practical feasibility of obtaining accurate fracture‐network reconstructions from temperature signals, at reasonable computational cost.

Yang, Xiaoyu↗

Altered cortical thickness-based structural covariance networks in type 2 diabetes mellitus

Cognitive impairment is a common complication of type 2 diabetes mellitus (T2DM), and early cognitive dysfunction may be associated with abnormal changes in the cerebral cortex. This retrospective study aimed to investigate the cortical thickness-based structural topological network changes in T2DM patients without mild cognitive impairment (MCI). Fifty-six T2DM patients and 59 healthy controls underwent neuropsychological assessments and sagittal 3-dimensional T1-weighted structural magnetic resonance imaging. Then, we combined cortical thickness-based assessments with graph theoretical analysis to explore the abnormalities in structural covariance networks in T2DM patients. Correlation analyses were performed to investigate the relationship between the altered topological parameters and cognitive/clinical variables. T2DM patients exhibited significantly lower clustering coefficient (C) and local efficiency (Elocal) values and showed nodal property disorders in the occipital cortical, inferior temporal, and inferior frontal regions, the precuneus, and the precentral and insular gyri. Moreover, the structural topological network changes in multiple nodes were correlated with the findings of neuropsychological tests in T2DM patients. Thus, while T2DM patients without MCI showed a relatively normal global network, the local topological organization of the structural network was disordered. Moreover, the impaired ventral visual pathway may be involved in the neural mechanism of visual cognitive impairment in T2DM patients. This study enriched the characteristics of gray matter structure changes in early cognitive dysfunction in T2DM patients.

Huang, Yang↗

Degrees of rate control and AutoDiff-driven direct sensitivity analysis in heterogeneous catalysis

Despite the wide application and benefits of the degree of rate control (DRC) analysis, several details remain argued, particularly about the conservation of DRCs at transient (TR) and steady-state (SS) conditions, especially for complex reaction networks. This work argues that previous proofs about the conservation properties of DRCs have been incomplete, and we provide new mathematical proofs at TR and SS conditions. In addition, we use both analytical (automatic differentiation) and numerical (finite difference) approaches to compute DRCs for the case study of ethane hydrogenolysis (EH) over Pt(111). This work confirms that at both TR and SS conditions, the sum of all DRCs, i.e., sum of the degrees of kinetic (DKRC) and thermodynamic rate control (DTRC), is conserved at zero. At SS conditions, the sum of DKRC is conserved at 1 while the sum of DTRC is conserved at −1. In corroboration of previous works, we show that the DTRC for any adsorbate at SS is equal to the product of the species coverage and a constant. In contrast, at TR conditions, the individual sums of both DTRC and DKRC are not conserved and can be any real number, with potential implications for the novel field of dynamic catalysis. Finally, we show that the conventional finite difference (FD) approach, only useful at SS, is prone to inaccuracy and very sensitive to the value of the differential change applied. The optimal differential value also varies significantly with system and rate definition. Consequently, we describe and illustrate in this work the application of the automatic differentiation (AD) approach for the more accurate determination of DRCs at both TR and SS conditions.

Automatic differentiation↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gross primary production (GPP) and red solar induced fluorescence (SIF) respond differently to light and seasonal environmental conditions in a subalpine conifer forest

The phenology of montane conifer forests is likely to shift in response to climate change and altered seasonal dynamics of light, temperature, and moisture. Solar-induced fluorescence (SIF) is expected to provide substantial improvement for mapping temporal changes in evergreen gross primary production (GPP) over greenness-based remote sensing indices. The utility of SIF to monitor seasonal changes in the phenology of conifer photosynthesis depends on the degree to which GPP and SIF respond in synchrony to key environmental drivers. However, to what extent SIF and GPP become decoupled by responding differently to the combined effects of light and other environmental conditions remains unknown. The goal of this study was to characterize the responses of GPP and SIFred to a suite of environmental drivers at the half-hour time scale and determine how these relationships change across seasons. We analyzed one year of tower-based SIFred and eddy covariance-derived GPP data from a conifer forest at Niwot Ridge, Colorado. We compared the light responses of GPP and SIFred across the year, finding that SIFred increased in response to light earlier in the year than did GPP. The light response of GPP had a positive temperature dependence in spring, and this dependency reversed in summer due to increased evaporative demand, while the light response of SIFred was less temperature dependent. Using artificial neural network ensemble analysis, we found that from spring to summer, SIFred did not exhibit a parallel response to the seasonally dynamic temperature and moisture controls on GPP. In summer SIFred was not correlated with canopy conductance, suggesting that SIF is less sensitive to stomatal control than GPP. Furthermore, our results suggest that, in conifers, photosystems begin to activate in spring prior to when water becomes available for photosynthesis, presenting a challenge for the use of SIF as a phenological indicator in conifer forests.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Transition of a network of nonlinear interactions into a regime of strong nonlinear fluctuations: A paradigm for the edge localized mode onset

We study how a network of nonlinear oscillators transits into a regime of strong nonlinear fluctuations when perturbed by a triad. In this regime, most of the potential energy contained in the waves is made available to the system through strong nonlinear fluctuations. This analysis is motivated by recent experimental observations [Dominski and Diallo, Plasma Phys. Control. Fusion 62, 095011 (2020)] where it was found that magnetic fluctuations trigger the onset of edge localized modes by suddenly exciting a network of nonlinear interactions. In our study, we consider the simplest system of many harmonic oscillators that are organized in a network of nonlinear triads. We model and simulate the sudden transition of this network of triads into a regime of strong nonlinear fluctuations—reminiscent of the onset of edge localized modes in tokamaks. This transition is triggered by the activation of a nonlinear perturbation. An abrupt rise of the system's disorder (an entropy-like quantity) is measured during the transition. This transition from weak to strong nonlinear fluctuations is even more abrupt when these fluctuations are chaotic, i.e., when the timescale of the nonlinear interaction is comparable to the timescale of the wave oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constructing Neural Network Based Models for Simulating Dynamical Systems

Dynamical systems see widespread use in natural sciences like physics, biology, and chemistry, as well as engineering disciplines such as circuit analysis, computational fluid dynamics, and control. For simple systems, the differential equations governing the dynamics can be derived by applying fundamental physical laws. However, for more complex systems, this approach becomes exceedingly difficult. Data-driven modeling is an alternative paradigm that seeks to learn an approximation of the dynamics of a system using observations of the true system. In recent years, there has been an increased interest in applying data-driven modeling techniques to solve a wide range of problems in physics and engineering. Here this article provides a survey of the different ways to construct models of dynamical systems using neural networks. In addition to the basic overview, we review the related literature and outline the most significant challenges from numerical simulations that this modeling paradigm must overcome. Based on the reviewed literature and identified challenges, we provide a discussion on promising research areas.

97 MATHEMATICS AND COMPUTING↗