At least 73 records · Page 4

Incident beam simulations for the CNCS instrument

This data set contains incident beam simulations for the 100 most frequently used configurations of the cold neutron chopper spectrometer (CNCS) instrument at the Spallation Neutron Source. A mcpl output was placed 0.2 m upstream of the sample position. Each file provides enough events to sufficiently sample the beam profile and intensity incident on the sample for that configuration. They can then be used for sample simulations.

47 OTHER INSTRUMENTATION↗

CNCS raw data for CoGeO3

Dataset collected at Cold Neutron Chopper Spectrometer at the Spallation Neutron Source, a DOE Office of Science User Facility operated by Oak Ridge National Laboratory.

36 MATERIALS SCIENCE↗

Monte–Carlo ray-tracing studies of multiplexed prismatic graphite analyzers for the cold-neutron triple-axis spectrometer at the High Flux Isotope Reactor

A modern cold triple-axis spectrometer to study quantum condensed matter systems is planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the conceptual principles and design of a secondary spectrometer using a multiplexed, prismatic analyzer system relying on graphite crystals and inspired by the successful implementation of the Continuous Angle Multiple Energy Analysis (CAMEA) spectrometers at the Paul Scherrer Institute. This project is currently known as MANTA for Multi-Analyzer Neutron Triple-Axis. Here, we report Monte-Carlo ray-tracing simulations on a simple but realistic sample scattering kernel to further illustrate the prismatic analyzer concept’s workings, calibration, and performance. Then, we introduce a new statistical analysis approach based on the prismatic analyzer concept to improve the number of final energies measured on the spectrometer. We also study possible evolutions in the CAMEA design relevant for MANTA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

γ-ray measurements in fast-neutron-induced reactions on 203 Tl

Fast-neutron-induced reactions can be used to characterize reaction mechanisms, investigate nuclear structure, and impose constraints on nuclear models. Because of the difficulty in predicting such effects, experimental data are important to constrain models. Thallium isotopes located close to the doubly magic Pb 208 nucleus are important for comparison with shell-model calculations. Study the population of excited states in Tl 203 and lighter isotopes in such reactions. Our methods are as follows. γ -ray cross sections were measured. The data were taken by using the Germanium Array for Neutron-Induced Excitations spectrometer. The pulsed neutron source of the Los Alamos Neutron Science Center's Weapons Neutron Research facility provided neutrons in the energy range from 1 to 300 MeV. The time-of-flight technique was used to determine the incident neutron energies. Cross sections for emission of several γ rays in 20 reaction channels were determined. Candidates for the intruder 9 / 2 - state in Tl 203 , from the odd proton in the h 9 / 2 orbital, and the first 5 + states in Tl 202 , 204 , from admixture of configurations, were identified. The excitation energy of the candidate 9 / 2 - , π h 9 / 2 state is in good agreement with the theoretical prediction from a semi-empirical weak-coupling model and its half-life is in the range of tens of nanoseconds. The feeding of a previously known isomer in Tl 202 exhibits similarities with the feeding of other isomers in this mass region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of the neutron irradiation station at the University of Notre Dame

Cross section data for neutron-induced reactions are needed for applications in nuclear astrophysics, stockpile stewardship, and nuclear reactor design but often contain discrepancies and gaps. A neutron source with a high neutron flux, a well-characterized neutron energy distribution, and a wide range of available neutron energies is ideal for studying such reactions in order to improve on existing data and provide new experimental results. For this purpose, the Neutron Irradiation Station (NIS) was developed using the 7 Li(p,n) 7 Be reaction. Neutron energy profiles were obtained using 3 He spectrometers and neutron standards were used to determine the neutron flux using the activation method. The neutron energy profile was found to be quasi-monoenergetic and neutrons were produced at energies from 1 keV to 1 MeV. Finally, the flux at the production target was found to be (1.42 ± 0.20) x 10 8 s −1 cm −2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental validation of an integrated modelling approach to neutron emission studies at JET

An integrated modelling methodology for the calculation of realistic plasma neutron sources for the JET tokamak has been developed. The computational chain comprises TRANSP plasma transport and DRESS neutron spectrum calculations, and their coupling to the MCNP neutron transport code, bridging plasma physics and neutronics. Here, we apply the developed methodology to the analysis of neutron emission properties of deuterium and helium plasmas at JET, and validate individual modelling steps against neutron diagnostic measurements. Two types of JET discharges are modelled—baseline-like and three-ion radio-frequency scenarios—due to their diversity in plasma heating, characteristics of the induced fast ion population, and the imprint of these on neutron emission properties. The neutron emission modelling results are quantitatively compared to the total neutron yield from fission chambers, neutron emissivity profiles from the neutron camera, neutron spectra from the time-of-flight spectrometer, and neutron activation measurements. The agreement between measured and calculated quantities is found to be satisfactory for all four diagnostic systems within the estimated experimental and computational uncertainties. Additionally, the effect of neutrons not originating from the dominating D(D, n) 3 He reactions is studied through modelling of triton burnup DT neutrons, and, in mixed D- 3 He plasmas, neutrons produced in the 9 Be(D, nγ) 10 B reaction on impurities. It is found that these reactions can contribute up to several percent to the total neutron yield and dominate the neutron activation of samples. Finally, the effect of MeV-range fast ions on the neutron activation of 115 In and 27 Al samples is measured and computationally validated.

integrated modelling↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

First full Dalitz plot measurement in neutron 𝛽 decay using the Nab spectrometer and implications for new physics

Precision measurements of observables in neutron 𝛽 decay are used to test the standard model description of the weak interaction and search for evidence of new physics. The Nab experiment at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was constructed to measure correlations in neutron decay by utilizing an asymmetric spectrometer and novel detection system to accurately reconstruct the proton momentum and electron energy for each 𝛽 decay. This work describes the detection of neutron 𝛽-decay products in the Nab spectrometer and presents the first full Dalitz plot representation of the phase space of neutron 𝛽 decay for all electrons >100 keV. In addition, new constraints are placed on a possible excited neutron state, hypothesized to explain the disagreement between the appearance and disappearance neutron lifetime techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low energy inelastic neutron scattering (INS) data of SrCoGe2O6 taken at CNCS chopper spectrometer.

INS measurements were performed using the Cold Neutron Chopper Spectrometer CNCS at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a standard orange cryostat was used to cover the temperature region from 1.7 K to 100 K. Data were collected using fixed incident neutron energy of 5.0 meV.

MATERIALS SCIENCE↗

pathSQE : an automated workflow for single-crystal inelastic neutron scattering data processing and analysis

Inelastic neutron scattering (INS) experiments utilizing modern time-of-flight spectrometers enable the comprehensive mapping of the energy (E)- and momentum (Q)-resolved dynamical structure factor of single crystals, probing both the lattice and magnetic excitations. Yet, the large size and complexity of four-dimensional INS data are challenging current analysis workflows, often resulting in an underutilization of the measured information. To help address this issue, this paper introduces new software interfaced with the Mantid framework, pathSQE, designed to streamline the processing, analysis and interpretation of 4D single-crystal INS data. By automating key tasks such as 1D/2D slicing, symmetrization, Brillouin zone folding, data visualization, prioritization and filtering, and comparisons with simulations, pathSQE facilitates and accelerates INS data analysis workflows. Here, this paper outlines the features and implementation and provides several illustrations of the use of pathSQE on data collected on single crystals using direct-geometry time-of-flight spectrometers at the Spallation Neutron Source, including Ge, FeSi, MnO and SnS single-crystal measurements on the ARCS, HYSPEC and CNCS neutron spectrometers. Beyond streamlining post-experiment data processing, pathSQE establishes an automated and modular processing pipeline that could support future real-time experiment steering.

36 MATERIALS SCIENCE↗

Improved determination of the 𝛽−‾‾𝜈𝑒 angular correlation coefficient 𝑎 in free neutron decay with the 𝑎⁢SPECT spectrometer

We report on a precise measurement of the electron-antineutrino angular correlation (𝑎 coefficient) in free neutron beta decay from the 𝑎⁢SPECT experiment. The 𝑎 coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4⁢𝜋 by the 𝑎⁢SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100-day run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain 𝑎=−0.10430⁢(84) which is the most precise measurement of the neutron 𝑎 coefficient to date. From this, the ratio of axial vector to vector coupling constants is derived giving |𝜆|=1.2677⁢(28).

Beck, Marcus↗

High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.

INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.

MATERIALS SCIENCE↗

C 12 ( n , n 1 ′ γ ) partial γ -ray cross section measured using the GENESIS array

Improved neutron inelastic scattering cross sections have repeatedly been identified as a top priority nuclear data need, important for basic science and a range of applications in nuclear energy, stockpile stewardship, and proliferation detection. For the C 12 ( n , n ′ γ ) reaction in particular, recent measurements have unveiled some structural discrepancies, demonstrating incongruities among themselves and in relation to the ENDF/B-VIII.0 nuclear data evaluation. To help resolve these disagreements, a measurement was performed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory using a broad-spectrum neutron beam and a 99.8% pure natural carbon target. The Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was employed to measure energy-differential γ -ray emission spectra as a function of incident neutron energy in the energy range of 5.5 to 16.7 MeV. The C 12 partial γ -ray cross sections were extracted at 63 ∘ , 122 . 5 ∘ , and 150 ∘ with respect to the incoming neutron beam and integrated using angular distribution data available in the literature. The data show agreement with a recent literature measurement and evaluation from 11 to 15 MeV, but indicate a larger cross section for incident neutron energies between 5.5 and 8.5 MeV. The measured relative angular distributions are also reported and were found to agree with evaluation. Published by the American Physical Society 2025

Gordon, J. M. (ORCID:0009000789886897)↗

Forward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering

The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via 𝜒 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98%-enriched 56 Fe target, GENESIS was used to perform a simultaneous measurement of 56 Fe 𝛾-ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential 𝛾-ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete 𝛾-ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved (𝑛, 2⁢𝑛) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced 𝛾-ray production data while directly probing reaction model physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dataset for First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics

The Nab apparatus at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was designed to measure key observations in neutron beta decay, test the Standard Model's description of the weak interaction, and search for new physics. This data was collected using the Nab apparatus and are presented in the article "First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics." This data publication includes CSV (comma-separated values) files which are used to generate Figures 3 - 11 in the linked journal article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inelastic Neutron Scattering Data for Ba₃Zn(Ru₀.₁Sb₁.₉)O₉

This dataset contains inelastic neutron scattering measurements on the magnetically dilute compound Ba₃Zn(Ru₀.₁Sb₁.₉)O₉, collected at the Spallation Neutron Source using the Cold Neutron Chopper Spectrometer (CNCS) and the SEQUOIA Fine-Resolution Fermi Chopper Spectrometer. The sample consists of nominally 5% magnetic Ru⁵⁺ ions (S = 3/2) randomly substituted into a diamagnetic Sb⁵⁺ matrix. Measurements were performed at base temperature (2–5 K) and 300 K using multiple incident energies (1.00, 3.32, 12.0, and 100 meV) to resolve magnetic excitations from isolated monomers and small Ru clusters (dimers, trimers, etc.). The dataset includes raw event-mode files, momentum- and energy-resolved spectra, and supporting metadata for instrument configuration, sample environment, and reduction parameters.

36 MATERIALS SCIENCE↗