Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Second Target Station Project: Biological & Environmental Science Workshop

Recent advances in neutron sources and instrumentation have opened up many new opportunities for the application of neutron scattering techniques in the biological and environmental sciences. Neutrons enable studies of the structure and dynamics of biological and environmental samples with a particular sensitivity to light elements, such as hydrogen, which is a key component of biological and environmental samples. Studies using neutrons are complementary to X-rays and have the unique advantage of being non-destructive and highly-penetrating. Oak Ridge National Laboratory’s upcoming Spallation Neutron Source (SNS) Second Target Station (STS) will provide high brightness cold neutron sources that significantly advance the scientific capabilities of neutron scattering instruments. The STS will advance our understanding of biological and environmental processes across spatial and temporal scales. The capabilities will enhance our ability to discover, design, and develop new materials essential for advanced sustainable technologies to address society’s most pressing needs. This report summarizes the discussions and recommendations from a joint workshop held by the STS Project and the Biological and Environmental Systems Science Directorate (BESSD) in June 2022. The purpose of the workshop was to explore science opportunities and capabilities related to biological and environmental systems that could be incorporated into both current and future STS instrument designs, as well as additional instruments at the SNS First Target Station (FTS) and High Flux Isotope Reactor (HFIR). With six breakout sessions, each with two invited plenary speakers from other institutions, the participants discussed a wide range of topics relevant to biological and environmental research. Based on the input from participants, a number of recommendations on instrumentation, sample environments, complementary multi-modal methods, data processing and analysis and sample deuteration are provided in the report. The participants also identified science opportunities that are emerging from the planned instrument capabilities at STS. Selected recommendations and science opportunities are listed in the Executive Summary.

54 ENVIRONMENTAL SCIENCES↗

A Novel Technique of Extracting UCN Decay Lifetime from Storage Chamber Measurements Dominated by Scattering Losses

The neutron’s lifetime is a critical parameter in the standard model. Its measurements, particularly measurements using both beamline and ultracold neutron storage techniques, have revealed significant tension. In this work, we review the status of the tension between various measurements, especially in light of the insights provided by the β-decay correlation measurements. We revisit the lifetime measurement in a material storage chamber, dominated by losses from scattering off the walls of the storage chamber. The neutron energy spectra and associated uncertainties were, for the first time, well-characterized using storage data alone. Such models have applications in the extraction of the mean time between wall bounces, which is a key parameter for neutron storage disappearance experiments in search of neutron oscillation. A comparison between the loss model and the number of neutrons stored in a single chamber allowed us to extract a neutron lifetime of τn*=880(+158/−78)stat.(+230/−114)sys.s (68.3% C.I.). Though the uncertainty of this lifetime is not competitive with currently available measurements, the highlight of this work is that we precisely identified the systematic sources of uncertainty that contribute to the neutron lifetime measurements in material storage bottles, namely from the uncertainty in the energy spectra, as well as from the storage chamber surface parameters of the Fermi potential and loss per bounce. In doing so, we highlight the underestimation of the uncertainties in the previous Monte Carlo simulations of experiments using the technique of ultracold neutron storage in material bottles.

Mohanmurthy, Prajwal (ORCID:0000000275737010)↗

Gallium in chondritic meteorites.

Gallium abundance measured in carbonaceous, enstatite and chondrite meteorites, using neutron activation technique

METEORITIC COMPOSITION↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE

This report summarizes the neutron imaging techniques and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. The experimental results and technique developments reported herein support the US Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in hightemperature microreactor designs is addressed by means of high-spatial-resolution neutron imaging coupled with custom-built and application-specific furnaces. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. Neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metals hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on the first two in-situ heating measurements of YH x performed over the 2020 and 2021 LANSCE operation cycles. In parallel with in-situ heating measurements, neutron computed tomography scans were performed to visualize hydrogen aggregates in post-heated YH x samples. Analysis and results from these neutron imaging measurements are given along with outlooks and plans for improving future hydrogen diffusion measurements at LANSCE.

47 OTHER INSTRUMENTATION↗

On the Feynman-alpha method for reflected fissile assemblies

The Feynman-alpha method is a neutron noise technique that is used to estimate the prompt neutron period of fissile assemblies. The method and quantity are of widespread interest including in applications such as nuclear criticality safety, safeguards and nonproliferation, and stockpile stewardship; the prompt neutron period may also be used to infer the k eff multiplication factor. The Feynman-alpha method is predicated on time-correlated neutron detections that deviate from a Poisson random variable due to multiplication. Traditionally, such measurements are diagnosed with one-region point kinetics, but two-region models are required when the fissile assembly is reflected. This paper presents a derivation of the two-region point kinetics Feynman-alpha equations based on a double integration of the Rossi-alpha equations, develops novel propagation of measurement uncertainty, and validates the theory. Validation is achieved with organic scintillator measurements of weapons-grade plutonium reflected by various amounts of copper to achieve k eff values of 0.83–0.94 and prompt periods of 5–75 ns. The results demonstrate that Feynman-alpha measurements should use the two-region model instead of the one-region model. The simplified one-region model deviates from the validated two-region models by as much as 10% in the estimate of the prompt neutron period, and the two-region model reduces to the one-region model for small amounts of reflector. The Feynman-alpha estimates of the prompt neutron period are compared to those of the Rossi-alpha approach. The comparative results demonstrate that the Feynman-alpha method is more precise than the Rossi-alpha method and more accurate for k eff < 0.92, whereas the Rossi-alpha method is generally more accurate for higher multiplications. Here, the uncertainty propagation developed in this work should be used for all Feynman-alpha measurements and will therein improve fitting accuracy and appropriate precision estimates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Towards understanding the magnetic properties of the breathing pyrochlore compound Ba3Yb2Zn5O11through single-crystal studies

Abstract Ba 3 Yb 2 Zn 5 O 11 is exceptional among breathing pyrochlore compounds for being in the nearly-decoupled limit where inter-tetrahedron interactions are weak, hosting isolated clusters or molecular magnet-like tetrahedra of magnetic ytterbium (Yb 3+ ) ions. In this work, we present the study carried out on single-crystal samples of the breathing pyrochlore Ba 3 Yb 2 Zn 5 O 11 , using a variety of magnetometry and neutron scattering techniques along with theoretical modeling. We employ inelastic neutron scattering to investigate the magnetic dynamics as a function of applied field (with respect to both magnitude and direction) down to a temperature of 70 mK, where inelastic scattering reveals dispersionless bands of excitations as found in earlier powder sample studies, in good agreement with a single-tetrahedron model. However, diffuse neutron scattering at zero field and dc-susceptibility at finite field exhibit features suggesting the presence of excitations at low-energy that are not captured by the single tetrahedron model. Analysis of the local structure down to 2 K via pair distribution function analysis finds no evidence of structural disorder. We conclude that effects beyond the single tetrahedron model are important in describing the low-energy, low-temperature physics of Ba 3 Yb 2 Zn 5 O 11 , but their nature remains undetermined.

36 MATERIALS SCIENCE↗

Principles of Neutron Scattering from Condensed Matter. By Andrew T. Boothroyd. Oxford University Press, 2020. Pp. 512. Price GBP 55.00. ISBN 9780198862314.

Neutron scattering user facilities are increasingly used by ‘non-expert’ users, opening neutron scattering to new science fields and greatly increasing the scientific impact of these facilities. This book aims to bring the needed introduction to the expanding area of neutron scattering techniques to this wider audience of scientists using neutron scattering as part of their experimental portfolio. In my opinion, it completely succeeds in that goal and provides the right balance of introduction and in-depth discussion. I also like the layout of the book, with some figures and notes in the margin making it easy to read and navigate. As a ‘long-time’ neutron scatterer, I am excited to add this book to my book shelf.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Practical new method of measuring thermal-neutron fluence

Thermoluminescence dosimeter technique measures thermal-neutron fluence by encapsulating lithium flouride phosphor powder and exposing it to a neutron environment. The capsule is heated in a dosimeter reader, which results in light emission proportional to the neutron fluence.

Siebold, J. R.↗

Dual-energy fast neutron imaging using tunable short-pulse laser-driven sources

Here a novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Transmission Neutron Optical Devices Utilizing Micro-Machined Structures

Neutrons are a powerful probe in material science with unique penetrating abilities. A major challenge stems from the fact that neutron optical devices are limited to refractive indices on the order of n≈1±10−5. By exploiting advances in precision manufacturing, we designed and constructed micro-meter period triangular grating with a high-aspect ratio of 14.3. The manufacturing quality is demonstrated with white-light interferometric data and microscope imaging. Neutron-scattering experiment results are presented, showing agreement with refraction modelling. The capabilities of neutron Fresnel prisms and lenses based on this design are contrasted with existing neutron focusing techniques, and the path separation of a prism-based neutron interferometer is estimated.

Kapahi, Connor (ORCID:0000000160516859)↗

Measurement of capsule heat transfer gaps using neutron radiography

A technique is described for measuring heat transfer gaps from neutron radiographs. The method involves scanning the radiograph negative with a recording microdensitometer to obtain a trace of the optical density variation across the diameter of the capsule. The optical density change representing the gap is measured from the microdensitometer trace and related to the physical measurement. Heat transfer gaps from 0.061 to 0.178 cm have been determined by this technique and agree with preassembly physical measurements to plus or minus 0.005 cm.

Thaler, L. A.↗

Origin of magnetic ordering in half-Heusler RuMnGa

The half-Heusler alloy RuMnGa having valence electron count (VEC) 18 has recently been theoretically proposed to exhibit compensated ferrimagnetic (CFiM) character instead of the expected nonmagnetic ground state. On the other hand, a preliminary experimental study proposed ferromagnetic (FM) ordering. As no half-Heusler system with VEC 18 is known to exhibit magnetic ordering, we have investigated the details of crystal structure and magnetic properties of RuMnGa using a combination of experimental tools, viz., x-ray and neutron diffraction techniques, dc and ac susceptibility, isothermal magnetization, heat capacity, resistivity and neutron depolarisation measurements. Rietveld refinements of x-ray and neutron diffraction data suggest single phase nature of the compound with elemental composition RuMn 0.86 Ga 1.14 . We have shown that the system exhibits FM-type ordering owing to the inherent presence of this minor off-stoichiometry, showing very low magnetic moment. Further, the system also exhibits reentrant canonical spin-glass behavior, which is rarely observed in half-Heusler alloys. The temperature coefficient of resistivity changes its sign from negative to positive and further to negative as the temperature decreases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extended flexibility of neutron Larmor diffraction for increased diffraction range in mosaicity measurements

Larmor diffraction (LD) is a neutron scattering technique that offers enhanced resolution by harnessing the Larmor precession of neutron spins in a magnetic field. By encoding subtle changes in neutron momentum transfer into significant alterations in the Larmor phase of neutron spins, LD can be employed to measure lattice expansion, lattice distortion, and mosaicity with exceptional resolution. As originally proposed by Rekveldt et al., LD necessitates the magnetic field boundaries to be tilted to be parallel to the crystal plane of interest. Here, this report explores the fundamental principles shared between LD and spin-echo small-angle neutron scattering (SESANS). Drawing inspiration from the flexibility of SESANS to adjust magnetic field boundaries to optimize the resolution in the measurement of the neutron momentum transfers q, we will demonstrate that the strict requirement of parallel alignment between the magnetic field boundaries and the crystal plane can be relaxed for the measurements of mosaicity. Such relaxation will expand the accessible diffraction angles for these situations that are highly constrained.

Larmor diffraction↗