Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutrons, SNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Upgrade of the SNS Extraction Kicker Power Supplies for the Proton Power Upgrade

The Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS) aims to enhance the linear accelerator's power output from 1.4 to 2.8 megawatts. A critical focus lies on upgrading the Extraction Kicker Power Supplies to handle the amplified beam power. The existing capacitor charging power supplies lacked the capability to charge the Blumlein-type Pulse Forming Network (PFN) to the required 40 kV at a repetition rate of 60 Hz. To address this limitation, an initial solution involving the use of a resonant charging circuit was proposed. However, a challenge arose with a self-firing issue in the thyristor switch, which proved unsolvable within the given timeframe. Facing a critical decision point in the project, an alternative approach was explored: integrating a supplementary power supply to enhance the overall power capacity. This solution was tested and ultimately chosen as the path forward. To accommodate the additional power supply, the power distribution system had to undergo upgrades. Throughout this endeavor, a comprehensive examination of the system took place, with meticulous identification of key components. This paper delves into the technical challenges encountered during the process and the corresponding solutions that were implemented.

Tan, Yugang [ORNL] (ORCID:0000000155968252)↗

Cavity Qualification and Production Update for SNS-PPU Cryomodules at Jefferson Lab

The Proton Power Upgrade (PPU) project at Oak Ridge National Lab’s Spallation Neutron Source (SNS) currently being constructed will double the proton beam power capability from 1.4 to 2.8 MW by adding seven cryomodules, each containing four six-cell high-beta (β = 0.81) superconducting radio frequency cavities. Research Instruments, located in Germany, built and processed the cavities at the vendor site, including electropolishing as the final active chemistry step. Twenty-eight cavities for seven cryomodules and an additional four cavities for a spare cryomodules were delivered to Jefferson Lab and first qualification tests were completed on all cavities as received from the vendor. The performance largely exceeded the requirements on quality factor and accelerating gradient. Here we present the status of initial cavity qualification tests, rework on unqualified cavities and final cavity qualification with helium vessel prior to installation in cryomodules. In addition, an update on cryomodule production is presented.

Dhakal, P.↗

Spectral Flux Measurements on SNS Direct Geometry Spectrometers at IRP-2 End-of-Life

The Inner Reflector Plug (IRP) of the Spallation Neutron Source (SNS) was replaced during the SNS shutdown period beginning 25 November 2025. This IRP, IRP-2, was first placed in service in May 2018, and was in use for 42.5 GW-hrs of operation, somewhat longer than its original design life of 30 GW-hrs, or even a refined estimate of 33 GW-hrs for the water moderator poison plate and 39 GW-hrs on the decoupled-poisoned hydrogen moderator decoupler (Gallmeier, Lu, and Iverson 2018). The time-integrated power history for IRP-2 is tracked in Figure 1.

43 PARTICLE ACCELERATORS↗

Broadband Wide-Angle VElocity Selector (BWAVES) neutron spectrometer designed for the SNS Second Target Station

A recently proposed wide-angle velocity selector (WAVES) device for choosing the velocity of detected neutrons after they have been scattered by the sample paves the way for inverted geometry neutron spectrometers with continuously adjustable final neutron wavelength. BWAVES broadband inverted geometry spectrometer proposed for the Second Target Station at the Spallation Neutron Source at Oak Ridge National Laboratory is designed using WAVES to simultaneously probe dynamic processes spanning 4.5 decades in time (energy transfer). This makes BWAVES a uniquely flexible instrument which can be viewed as either a quasielasitc neutron scattering (QENS) spectrometer with a practically unlimited (overlapping with the vibrational excitations) range of energy transfers, or a broadband inelastic vibrational neutron spectrometer with QENS capabilities, including a range of accessible momentum transfer (Q) and a sufficiently high energy resolution at the elastic line. The new capabilities offered by BWAVES will expand the application of neutron scattering in ways not possible with existing neutron spectrometers.

36 MATERIALS SCIENCE↗

Analyses of Dose Rates for Second Inner Reflector Plug Replacement at Spallation Neutron Source

The Inner Reflector Plug (IRP) is a central component of the Spallation Neutron Source (SNS) target monolith, which houses the liquid mercury target and four liter-sized neutron moderator units. It is exposed to high-level radiation fields during routine operation and builds up significant activity. The IRP needs to be replaced due to moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The first IRP exchange took place in March 2018 and next one, which is IRP2, is planned to be replaced during the facility maintenance period in the end of December 2025, beginning of January 2026 calendar year. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. For planning the replacement workflow to help to reduce radiation exposure to workers dose rates for each stage of extraction/replacement operation are predicted.

42 ENGINEERING↗

Progress on Machine Learning for the SNS High Voltage Converter Modulators

The High-Voltage Converter Modulators (HVCM) used to power the klystrons in the Spallation Neutron Source (SNS) linac were selected as one area to explore machine learning due to reliability issues in the past and the availability of large sets of archived waveforms. Progress in the past two years has resulted in generating a significant amount of simulated and measured data for training neural network models such as recurrent neural networks, convolutional neural networks, and variational autoencoders. Applications in anomaly detection, fault classification, and prognostics of capacitor degradation were pursued in collaboration with the Jefferson Laboratory, and early promising results were achieved. This paper will discuss the progress to date and present results from these efforts.

Pappas, Chris↗

SEEMS: A Single Event Effects and Muon Spectroscopy facility at the Spallation Neutron Source

This study outlines a concept that would leverage the existing proton accelerator at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory to enable transformative science via one world-class facility serving two missions: Single Event Effects (SEE) and Muon Spectroscopy (μSR). The μSR portion would deliver the world’s highest flux and highest resolution pulsed muon beams for material characterization purposes, with precision and capabilities well beyond comparable facilities. The SEE capabilities deliver neutron, proton, and muon beams for aerospace industries that are facing an impending challenge to certify equipment for safe and reliable behavior under bombardment from atmospheric radiation originating from cosmic and solar rays. With negligible impact on the primary neutron scattering mission of the SNS, the proposed facility will have enormous benefits for both science and industry. Herein, we have designated this facility “SEEMS.”

47 OTHER INSTRUMENTATION↗

Performance Improvements on SNS and HFIR Instrument Data Reduction Workflows Using Mantid

Performance of data reduction workflows at the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is mainly determined by the time spent loading raw measurement events stored in large and sparse datasets. This paper describes: (1) our long-term view to leverage SNS and HFIR data management needs with our experience at ORNL’s world-class high performance computing (HPC) facilities, and (2) our short-term efforts to speed up current workflows using Mantid, a data analysis and reduction community framework used across several neutron scattering facilities. We show that minimally invasive short-term improvements in metadata management have a moderate impact in speeding up current production workflows. We propose a more disruptive domain-specific solution: the No Cost Input Output (NCIO) framework, we provide an overview, the risks and challenges in NCIO’s adoption by HFIR and SNS stakeholders.

Godoy, William↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗

Thermal scattering law for ice based on neutron time-of-flight experiments carried out at the SEQUOIA spectrometer at the Oak Ridge National Laboratory

Precise estimation of neutron thermalization in moderators relies on high-fidelity thermal scattering cross-section data governed by the thermal scattering law (TSL). The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) has been working on the development of improved TSL for light water ice. Many polymorphic phases of light water ice exist depending on the thermodynamic conditions. The most common type of ice at standard pressure and temperature below water freezing point (273.15 K) is ice-Ih. It is essential to have high-resolution experimental double differential data for developing and/or validating TSL for moderator materials.Existing experimental double-differential scattering data for ice-Ih are extremely sparse and of limited quality. New high-quality double-differential measurements for ice-Ih over multiple temperatures and incident neutron energies would directly support the validation and improvement of ice-Ih TSL models for criticality safety applications.Series of time-of-flight (TOF) inelastic neutron scattering experiments on ice-Ih at temperatures starting at 271 K and down to 6 K, have been carried out at the SEQUOIA spectrometer at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), United States. The experiments have been performed for incident neutron energies, Ei= 11, 55, 160, 250, and 600 meV, to explore different excitation energies in the vibrational phonon spectrum. This paper presents the thermodynamic conditions and the details of the TOF measurements on ice-Ih and the derived phonon spectrum from the experimentally measured double differential data. A study of the variation of the phonon spectrum of ice-Ih as a function of temperature is highlighted, and a preliminary TSL evaluation is developed based on the experimental phonon spectrum.

Jaiswal, V↗

Low-energy H- beam injectors for particle accelerators: upgrade requirements, challenges and future plans [Slides]

High brightness, negative hydrogen ion sources are used extensively in large, accelerator-based, user facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Much larger beams of H- ions are also utilized for neutral beams injection into fusion machines and will be discussed in a separate companion presentation. Some of the accelerator facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), the CERN LHC injector, the Chinese Spallation Neutron Source (CSNS) as well as numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly with cyclotrons. Many facilities are currently working on various improvement / upgrade projects, both in the near and long term, which are driving further development of their ion source and LEBT (Low Energy Beam Transport) and, in some cases, their overall front end injector system. This report will first provide a simple description of each facilities existing ion source and LEBT and summarize the operational parameters which are currently being routinely injected into their accelerators. Next, the parametric goals of each of the facilities upgrade projects are specified as well as development efforts currently underway to meet these requirement and improvement goals. It is hoped that that this work will not only capture the current state-of-the-art of worldwide H- beam injectors and clarify the research goals and efforts of the community in general but will also encourage further inter laboratory collaborations.

43 PARTICLE ACCELERATORS↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Laser-assisted high-energy proton pulse extraction for feasibility study of co-located muon source at the SNS

Here, we have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (μSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H - ) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam based on laser neutralization causes only 0.2% reduction of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neutron facilities, and thus the proposed method will result in negligible impact on the SNS operation. This paper describes the development of a fiber/solid-state hybrid laser system that has high flexibility of pulse structure and output power, initial experiments on laser neutralization of beam and separation of H 0 beam from the existing SNS accelerator beam line, conversion of H 0 to proton at the SNS linac dump, and measurement results of 30 ns/50 kHz proton pulses. This system conclusively demonstrates the feasibility of laser-based proton beam extraction to power a world-leading μSR facility at the SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-Cutting Software Solutions in Support of Experimental Analysis Challenges at National Scattering Facilities

Rapid improvements in instrumentation at neutron and light source combined with new capabilities in computing, data analytics, and machine learning offer unprecedented scientific capabilities to address fundamental and applied science questions in a wide area of subjects from quantum materials to biological systems. In order to make these capabilities accessible to the broader scientific community, significant developments are needed related to workflow spanning from experimental control to advanced materials simulations as well as the underpinning scientific software. In this chapter, we explore these needs and recent developments at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A central part of the workflow at the SNS is the data reduction framework Mantid which is developed as a partnership between European and US neutron-scattering facilities.

Proffen, Thomas↗

Ramp Generator for Electron Scanner in SNS Beam Profile Measurements System

A new fast high voltage Ramp Generator to deflect an electron beam in the Electron Scanner is required at the Spallation Neutron Source (SNS) in the Oak Ridge National Laboratory. The Electron Scanner is used for non-destructively measuring the transverse profiles of the proton beam in the accumulator ring of the SNS [1]. The existing deflector is obsolete and needs to be replaced. A new Ramp Generator is proposed based on fast high voltage MOSFET power switches. Two configurations have been considered. One is bipolar, with two opposite polarity power supplies and one switch module or two single switches, and the other is unipolar, with one power supply and two switch modules. Schematics and performance of both options are described, and results of the prototype testing are presented in the paper.

Peplov, Vladimir↗

Radioisotope production at the Spallation Neutron Source: Design concept of experimental target station

Completion of the Proton Power Upgrade Project for the Spallation Neutron Source (SNS) accelerator at Oak Ridge National Laboratory opens an opportunity to utilize reserve beam power of more than 100 kW for applications beyond neutron production. One of these applications is the production of critical radionuclides. To demonstrate the feasibility of using the reserve beam power to produce radioisotope at SNS, a design concept of a small-scale experimental target station in the Linac Dump area has been developed. This experimental facility will provide isotope yield benchmarking data using protons in the GeV range. It will also enable additional research and development in isotope handling and radiochemical separation. The target station consists of a target module enclosed in a vessel and concrete shielding. Particle transport calculations and thermo-mechanical simulations are used to determine beam parameters, decay time, isotope yield, shielding dimensions, and target design parameters. Calculations verified that the irradiated capsule can be handled manually using hands-off tools and transported to a hot cell in a shielded container for post-irradiation characterizations.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

Neutron Characterization for Additive Manufacturing

Oak Ridge National Laboratory (ORNL) is leveraging decades of experience in neutron characterization of advanced materials together with resources such as the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) shown in Fig. 1 to solve challenging problems in additive manufacturing (AM). Additive manufacturing, or three-dimensional (3-D) printing, is a rapidly maturing technology wherein components are built by selectively adding feedstock material at locations specified by a computer model. The majority of these technologies use thermally driven phase change mechanisms to convert the feedstock into functioning material. As the molten material cools and solidifies, the component is subjected to significant thermal gradients, generating significant internal stresses throughout the part (Fig. 2). As layers are added, inherent residual stresses cause warping and distortions that lead to geometrical differences between the final part and the original computer generated design. This effect also limits geometries that can be fabricated using AM, such as thin-walled, high-aspect- ratio, and overhanging structures. Distortion may be minimized by intelligent toolpath planning or strategic placement of support structures, but these approaches are not well understood and often "Edisonian" in nature. Residual stresses can also impact component performance during operation. For example, in a thermally cycled environment such as a high-pressure turbine engine, residual stresses can cause components to distort unpredictably. Different thermal treatments on as-fabricated AM components have been used to minimize residual stress, but components still retain a nonhomogeneous stress state and/or demonstrate a relaxation-derived geometric distortion. Industry, federal laboratory, and university collaboration is needed to address these challenges and enable the U.S. to compete in the global market. Work is currently being conducted on AM technologies at the ORNL Manufacturing Demonstration Facility (MDF) sponsored by the DOE's Advanced Manufacturing Office. The MDF is focusing on R&D of both metal and polymer AM pertaining to in-situ process monitoring and closed-loop controls; implementation of advanced materials in AM technologies; and demonstration, characterization, and optimization of next-generation technologies. ORNL is working directly with industry partners to leverage world-leading facilities in fields such as high performance computing, advanced materials characterization, and neutron sciences to solve fundamental challenges in advanced manufacturing. Specifically, MDF is leveraging two of the world's most advanced neutron facilities, the HFIR and SNS, to characterize additive manufactured components.

Watkins, Thomas↗