At least 73 records · Page 4

Impedances of nickel electrodes cycled in various KOH concentrations

Recent tests at Hughes have shown that Ni/H2 cells cycled in 26 percent KOH have much longer lives than those cycled in other concentrations. As part of an ongoing program to try to correlate the impedances of nickel electrodes with their life and performance, impedances were measured of a number of electrodes from these tests that had been cycled in concentrations from 21 to 36 percent KOH. These had ranged from about 1000 to 40,000 cycles. After cycling ten times to reduce possible changes due to storage, impedances were measured at five voltages corresponding to low states of charge. The results were analyzed using a standard circuit model including Warburg impedance term. Lower kinetic resistances and Warburg slopes were found for several electrodes which had been cycled in 26 percent KOH even though they had been cycled for a much longer time than the others. Interpretation of the data is complicated by the fact that the cycle lives, storage times, and failure mechanisms varied. Several other circuit models have also been examined, but the best correlations with life were found with parameters obtained from the simple model.

Margaret A Reid↗

Raman structural studies of the nickel electrode

The objectives of this investigation have been to define the structures of charged active mass, discharged active mass, and related precursor materials (alpha-phases), with the purpose of better understanding the chemical and electrochemical reactions, including failure mechanisms and cobalt incorporation, so that the nickel electrode may be improved. Although our primary tool has been Raman spectroscopy, the structural conclusions drawn from the Raman data have been supported and augmented by three other analysis methods: infrared spectroscopy, powder X-ray Diffraction (XRD), and x-ray absorption spectroscopy (in particular EXAFS, Extended X-ray Absorption Fine Structure spectroscopy).

Cornilsen, Bahne C.↗

Electrochemical generation of hexacyanoferrate and hexacyanoruthanate electroactive films at nickel electrode surfaces: A promising synthetic approach for new electrode materials in metal ion batteries and supercapacitors

Prussian blue analogues (PBAs) have been recently investigated as promising electrode materials for battery and supercapacitor applications. While most explorations have focused on PBA nanoparticles, very little attention has been focused on PBA films deposited on a metallic support. In this work, we have examined electrogenerating hexacyanoferrate (HCF) and hexacyanoruthenate (HCR) films on nickel surfaces via cyclic voltammetry. We found that the total material deposited was influenced by the metal cation present in the electrolyte solution and that, on average, the rate of deposition of the surface adsorbed/immobilized species was dependent on the species in solution. In particular, films electrogenerated in the presence of Na + and K + had the highest deposition rates. The cyclic voltammetric profiles exhibited dramatic differences depending on the cation present in the electrolyte solution. In addition, we found that all films were electrochemically irreversible in the presence of Li + and Mg 2+ containing electrolyte solutions. Further, and as a proof of concept, we modified high surface area nickel electrodes with HCF in sodium-based electrolytes, finding that these electrodes could operate reversibly at equivalent C-rates as high as 1667C.

25 ENERGY STORAGE↗

Zinc treatment to enhance nickel electrode performance for liquid alkaline water electrolyzers

Raney Ni treatment is introduced to the surface of Ni mesh anode electrodes, enhancing liquid alkaline water electrolyzer performance. The surface of the Ni mesh is alloyed with Zn, deposited by either an aqueous infiltration of Zn salt or direct reaction with Zn foil. The extent of alloying is controlled by a heat treatment step. For both processes, fine porosity and enhanced surface area are obtained after leaching the Zn out of the surface alloy layer. The observed electrode surface structure and performance is quite sensitive to the thermal treatment temperature. The enhanced surface area improves full cell performance by 90 mV for infiltrated Zn treated at 600 °C and by 185 mV for Zn foil reacted at 425 °C (at 2 A cm −2 and 80 °C). In conclusion, the Zn treatment methods produce stable operating performance, exhibiting no decay after 150 h for the infiltrated Zn treated at 600 °C, and a decay rate of 4.6 μV h −1 over 100 h for the Zn foil reacted at 425 °C (at 1 A cm −2 and 80 °C).

LAWE↗

Migration of Co in nickel oxide/hydroxide of a nickel electrode in a Ni/H2 cell

Cobalt redistribution in nickel active material has been reported. This redistribution was suspected to be related to capacity fading. The objective of this work is to establish a relationship between cobalt redistribution and capacity fading. Microscopic cobalt distribution in nickel active material was studied using three EDX techniques: line scan, point-by-point analysis, and dot maps. Results from this study are presented.

Lim, Hong S.↗

Rare Earth Nickelate Electrodes Containing Heavily Doped Ceria for Reversible Solid Oxide Fuel Cells

The electrochemical performance of composite rare-earth nickelate-rare-earth doped ceria oxygen electrodes, with a high level of rare-earth doping in ceria are reported. Additionally, the chemical stability of these compositions is reported at both the sintering (1240 ?C) and operating temperature (800 ?C). Specifically, a lanthanum nickelate La2NiO4+d (LNO) ?? 50 mol% lanthanum doped ceria (LDC50) oxygen electrode and a neodymium nickelate Nd2NiO4+d (NNO) ?? 50 mol% neodymium doped ceria (NDC50) oxygen electrode are tested in solid oxide fuel cell (SOFC) and solid oxide electrolysis cell (SOEC) modes and compared to a composite (La0.75Sr0.25)0.95MnO3±d (LSM)-8 mol% yttria stabilized zirconia (YSZ) electrode. The LNO–LDC50 oxygen electrode reaches a current density which is approximately three times that of the LSM-YSZ electrode in SOFC mode at 0.7 V and approximately two times the LSM-YSZ electrode at 1.2 V in SOEC mode. Similarly the NNONDC50 oxygen electrode reaches a current density which is approximately two times and approximately one and a half times that of LSM-YSZ at 0.7 V and 1.2 V respectively. Oxygen surface exchange results for LNO and NNO are also reported which show different oxygen exchange kinetics during oxidation versus reduction steps.

solid oxide electrolysis, solid oxide fuel cell (S↗

Simple processing via thermal treatment and catalyst infiltration to enhance nickel electrode performance for liquid alkaline water electrolyzers

Two simple processes for enhancing liquid alkaline water electrolyzer performance are demonstrated. Both enhance 3D Ni electrodes by introducing a micron-scale rough structure throughout the bulk of the electrode. Oxidation/reduction relies on a simple thermal treatment cycle to create surface roughening through the volumetric expansion during NiO formation and volume contraction during reduction back to Ni metal. Catalyst infiltration introduces a washcoat of additional metal particles throughout the electrode, by flooding the electrode with catalyst precursor and converting it to micron-scale particles via a reducing thermal treatment. Further, the largest improvement in performance (211mV at 1.8Acm -2 ) is observed for infiltrated NiFe-3x catalyst. For Fe-free Ni-only electrodes, oxidation/reduction provides a larger improvement (157 mV at 1.8Acm -2 ) than infiltrated Ni-3X (106mV at 1.8Acm -2 ). For both processes, the observed electrode surface structure and performance is quite sensitive to the thermal treatment temperature.

08 HYDROGEN↗

Real time charge efficiency monitoring for nickel electrodes in NICD and NIH2 cells

The charge efficiency of nickel-cadmium and nickel-hydrogen battery cells is critical in spacecraft applications for determining the amount of time required for a battery to reach a full state of charge. As the nickel-cadmium or nickel-hydrogen batteries approach about 90 percent state of charge, the charge efficiency begins to drop towards zero, making estimation of the total amount of stored charge uncertain. Charge efficiency estimates are typically based on prior history of available capacity following standardized conditions for charge and discharge. These methods work well as long as performance does not change significantly. A relatively simple method for determining charge efficiencies during real time operation for these battery cells would be a tremendous advantage. Such a method was explored and appears to be quite well suited for application to nickel-cadmium and nickel-hydrogen battery cells. The charge efficiency is monitored in real time, using only voltage measurements as inputs. With further evaluation such a method may provide a means to better manage charge control of batteries, particularly in systems where a high degree of autonomy or system intelligence is required.

Zimmerman, A. H.↗

Structural comparison of nickel electrodes and precursor phases

A summary of previous Raman spectroscopic results and a discussion of important structural differences in the various phases of active mass and active mass precurors are presented. Raman spectra provide unique signatures for these phases, and allow one to distinguish each phase, even when the compound is amorphous to X-rays (i.e., does not scatter X-rays because of a lack of order and/or small particle size). The structural changes incurred during formation, charge and discharge, cobalt addition, and aging will be discussed and related to electrode properties. Important structural differences include NiO2 layer stacking, nonstoichiometry (especially cation-deficit nonstoichiometry), disorder, dopant content, and water content. The results indicate that optimal nickel active mass is non-close packed and nonstoichiometric. The formation process transforms precursor phases into this structure. Therefore, the precursor disorder, or lack thereof, influences this final active mass structure and the rate of formation. Aging processes induce structural change which is believed to be detrimental. The role of cobalt addition can be appreciated in terms of structures favored or stabilized by the dopant. In recent work, the in situ Raman technique to characterize the critical structural parameters was developed. An in situ method relates structure, electrochemistry, and preparation. In situ Raman spectra of cells during charge and discharge, either during cyclic voltammetry or under constant current conditions were collected. With the structure-preparation knowledge and the in situ Raman tool, it will be possible to define the structure-property-preparation relations in more detail. This instrumentation has application to a variety of electrode systems.

Cornilsen, Bahne C.↗

Method of Making a Nickel Fiber Electrode for a Nickel Based Battery System

The general purpose of the invention is to develop a high specific energy nickel electrode for a nickel based battery system. The invention discloses a method of producing a lightweight nickel electrode which can be cycled to deep depths of discharge (i.e., 40% or greater of electrode capacity). These deep depths of discharge can be accomplished by depositing the required amount of nickel hydroxide active material into a lightweight nickel fiber substrate.

Doris L Britton↗

Expansion of the nickel electrode

To observe a reasonable amount of expansion, months or years in acutal batteries are required. Therefore, the technique of electrode bending was developed. Active material is taken off a sample electrode on one side, and left only on the other side with a cadmium counter electrode. With this configuration, if the active material expands, the electrode will bend convex - concave towards this direction. This very small bending may be easily detected with light deflection. A laser beam was used to project it on the screen through a mirror attached on the electrode, thus making a very sensitive measurement of a very small expansion.

Lim, H. S.↗

The CMG Nickel Electrode

The development and design of the Controlled Microgeometry electrode are described. Advantages of the electrode over others in existance include a higher number of ampere hours per kilogram and the ability to make them over a wide range of thicknesses. The parameters that control the performance of the electrode can be individually controlled over a wide range. Therefore, the electrode may be designed to give the optimum performance for a given duty cycle.

Depaul, R. A.↗

The definition of the process of electrochemical impregnation of nickel electrodes

Electrochemical impregnation was studied during a series of experiments designed to define the optimal conditions for the fabrication of dimensionally stable cell anodes of Ni-H2 and Ni-Cd systems. The influence of various parameters, such as current and duration of electrolysis, temperature and acidity of the chemical bath, the concentrations of Ni and Co as well as the use of ethanol was determined. Results show that the electrochemical impregnation process as defined is industrially feasible and it is suggested that Ni-H2 and Ni-Cd type electrodes be produced in sufficient quantity to further evaluate their performance characteristics.

Antoine, P.↗

The effect of different alkali metal hydroxides on nickel electrode life

An accelerated cycle-life test (100-percent depth of discharge) of a sintered-type Ni electrode has been carried out in a flooded cell containing different alkali metal hydroxide electrolytes such as LiOH, NaOH, KOH, RbOH, and CsOH. Decrease in Ni electrode capacity with cycling was reduced as the radius of the alkali metal ions, with possible exception of CsOH.

Lim, H. S.↗

Structural comparison of nickel electrodes and precursor phases

Researchers summarize previous Raman spectroscopic results and discuss important structural differences in the various phases of active mass and active mass precursors. Raman spectra provide unique signatures for these phases, and allow one to distinguish each phase, even when the compound is amorphous to x rays (i.e., does not scatter x rays because of a lack of order and/or small particle size). The structural changes incurred during formation, charge and discharge, cobalt addition, and aging are discussed. The oxidation states and dopant contents are explained in terms of the nonstoichiometric structures.

Cornilsen, Bahne C.↗

Structural comparison of nickel electrodes and precursor phases

In this paper the previous Raman spectroscopic results are summarized and important structural differences in the various phases of active mass and active mass precursors are discussed. Raman spectra provide unique signatures for these phases, and allow one to distinguish each phase, even when the compound is amorphous to X-rays (i.e., does not scatter X-rays because of a lack of order and/or small particle size). The structural changes incurred during formation, charge and discharge, cobalt addition, and aging wil be discussed. The oxidation states and dopant contents are explained in terms of the nonstoichiometric structures.

Cornilsen, Bahne C.↗

Impedances of electrochemically impregnated nickel electrodes as functions of potential, KOH concentration, and impregnation method

Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.

Reid, Margaret A.↗